Analysis of Control Error Factors of a Thermal Output Experiment for Radiant Heating Panels (복사난방패널 방열량실험의 제어오차요인 분석)

  • Shin, Dae-Uk
    • Land and Housing Review
    • /
    • v.9 no.4
    • /
    • pp.33-42
    • /
    • 2018
  • As a radiant heating panel gets more popularity, the need to study on evaluation method of thermal output of the panel also becomes increasing. Generally, the chamber using method is applied to evaluate the thermal output through an experiment. However, the chamber using method cannot be used due to the limitations on space and cost. EN1264 addresses the test equipment to evaluate the thermal output by using simpler experimental setup, and introduces application method in detail. However, there is not enough description of control methods to meet the experiment condition, and it is difficult to meet this when practical experiment. Therefore, this paper analysed the control error factors of when the thermal output experiment is performed. When EN1264 method is applied to evaluate the thermal output of the radiant floor heating panel, the error factor which is caused by the characteristic of test equipment cannot be removed by the control methods of chamber using method. In addition, the error factor can be occurred at the element which is located out of the control system. These possible error factors are defined as the characteristic error factors.

Evaluation of Heating and Cooling Thermal Output Characteristics of Prefabricated Steel Wall Panel System for Radiant Heating and Cooling (강판 마감형 조립식 벽패널 복사냉난방시스템의 냉난방 방열 특성 평가)

  • Lim, Jae-Han;Koo, Bo-Kyoung;Kim, Sung-Im;Song, Seung-Yeong
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.2
    • /
    • pp.70-77
    • /
    • 2013
  • Recently the radiant panel heating and cooling system has been regarded as an alternative of low temperature heating and high temperature cooling by applying the renewable energy sources to the heating and cooling of buildings. Especially this system can be used as HVAC system alternatives in super high-rise buildings for energy saving and thermal comfort. Also it can be possible to reduce the plenum space because the minimum ventilation air will be supplied into the space. This study focused on the evaluation the basic characteristics of thermal output in prefabricated steel wall panel system for radiant heating and cooling. In order to evaluate the thermal output according to both various supply water temperatures and supply water flow rates, three-dimensional dynamic heat transfer analysis was performed. As results, for the heating mode, thermal output increased by 26% with the supply temperature increasing by $5^{\circ}C$. The surface temperature of panels range within $1{\sim}3^{\circ}C$. For the cooling mode, thermal output decreased by 18.2% with the supply temperature increasing by $2^{\circ}C$. The surface temperature of panels range within $0.5{\sim}1^{\circ}C$ and it was shown the even temperature distribution.

Assessment of the radiant emittance of damaged/contaminated dental light-curing tips by spectrophotometric methods

  • Abdulrahman A. Balhaddad;Isadora Garcia;Fabricio Collares;Cristopher M. Felix;Nisha Ganesh;Qoot Alkabashi;Ward Massei;Howard Strassler;Mary Anne Melo
    • Restorative Dentistry and Endodontics
    • /
    • v.45 no.4
    • /
    • pp.55.1-55.12
    • /
    • 2020
  • Objectives: This study investigated the effects of physically damaged and resin-contaminated tips on radiant emittance, comparing them with new undamaged, non-contaminated tips using 3 pieces of spectrophotometric laboratory equipment. Materials and Methods: Nine tips with damage and/or resin contaminants from actual clinical situations were compared with a new tip without damage or contamination (control group). The radiant emittance was recorded using 3 spectrophotometric methods: a laboratory-grade thermopile, a laboratory-grade integrating sphere, and a portable light collector (checkMARC). Results: A significant difference between the laboratory-grade thermopile and the laboratory-grade integrating sphere was found when the radiant emittance values of the control or damaged/contaminated tips were investigated (p < 0.05), but both methods were comparable to checkMARC (p > 0.05). Regardless of the method used to quantify the light output, the mean radiant emittance values of the damaged/contaminated tips were significantly lower than those of the control (p < 0.05). The beam profile of the damaged/contaminated tips was less homogeneous than that of the control. Conclusions: Damaged/contaminated tips can reduce the radiant emittance output and the homogeneity of the beam, which may affect the energy delivered to composite restorations. The checkMARC spectrophotometer device can be used in dental offices, as it provided values close to those produced by a laboratory-grade integrated sphere spectrophotometer. Dentists should assess the radiant emittance of their light-curing units to ensure optimal curing in photoactivated, resin-based materials.

Clinical considerations in the use of dental light curing unit (광중합의 시작, 어떤 광조사기를 어떻게 사용해야할까?)

  • Lee, Chang-Ha
    • The Journal of the Korean dental association
    • /
    • v.57 no.3
    • /
    • pp.175-184
    • /
    • 2019
  • Increasing the aesthetic needs of patients and decreasing the use of amalgam had led to increased demand for dental resin composite. Thereby, light curing unit (LCU) has become an essential equipment in dental clinic. To ensure long-term prognosis of photopolymerized materials, LCU should have a uniform and consistent radiant output and an emission spectrum that includes the active wavelength range of photoinitiators. In addition, when the correct use and thorough maintenance and repair of LCU are performed, the higher success rate of restoration using photopolymerization materials will be achieved.

  • PDF

Analysis of Output Voltage Properties of Non-dispersive Infrared Gas Sensors According to Ambient Temperatures (주변 온도 영향에 따른 비분산 적외선 가스센서의 출력 특성 해석)

  • Park, Han-Gil;Yi, Seung-Hwan
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.5
    • /
    • pp.294-299
    • /
    • 2018
  • This article describes the output properties of non-dispersive infrared carbon dioxide($CO_2$) sensors resulting from the changes in ambient temperatures. After the developed sensor module was installed inside the gas chamber, the temperature was set to 267 K, 277 K, 300 K, and 314 K, and the concentrations of $CO_2$ gas were increased from 0 to 5,000 ppm. Then, the output voltage at each concentration was obtained. Through these experimental results, two observations were made. First, both the $CO_2$ sensor and the reference sensor showed an increase in the output voltages as the temperature rose from 0 ppm, Second, the full scale outputs of the $CO_2$ sensor grew as the temperature increased. The output characteristics were analyzed based on two factors: change in the radiant energy of the infrared light source and change in the absorptivity of $CO_2$ gas according to the ambient temperature. Additionally, temperature compensation methods were discussed.

Evaluation of the Outdoor Radiant Thermal Environment by Building Scale and Block Type of Office Building in Summer (사무소건물의 규모 및 배치유형에 따른 하기 옥외 복사열환경 평가)

  • Park, Su-Jin;Jung, Sun-Young;Yoon, Seong-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.6
    • /
    • pp.81-87
    • /
    • 2009
  • The purpose of this study is to evaluate of the outdoor thermal environment by building scale and block type as variable factors. In this study, 18 cases of office in central business district that have different condition are compared about their surface temperature, HIP(Heat Island Potential), and MRT(Mean Radiant Temperature). They are simulated with 3-dimension numerical simulation software named Hoyano-model. The output results contain visualized distribution chart and numerical data. The results of evaluation are as follows. (1)The surface temperature of the building becomes higher as building coverage ratio is higher but floor area ratio is lower. In same conditions, unified block type is maximum $3.2^{\circ}C$ higher than divided block type. (2)HIP shows different daily pattern as block type. During daytime, divided block type is much higher than unified block type but after sunset, it is changed. (3)MRT shows different distribution pattern as sunlight moves expecially at noon. (4)As the results of this study, cases that have high floor area ratio condition show lower surface temperature by tendency to stay low indoor temperature in office building and big rate of windows on building surface.

A Study on the Optimal Control Strategy of Air-Conditioning System with Slab Thermal Storage - The Difference by the Presence of Radiant Heat as a Criterion Factor - (슬래브축열의 최적제어방책에 관한 연구 -평가요소로 복사열의 고려 유무에 의한 차이-)

  • Jung Jae-Hoon;Shin Young-Gy
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.4
    • /
    • pp.287-296
    • /
    • 2006
  • In this paper, optimal control strategy of the air-conditioning system with slab thermal storage was investigated based on the optimal control theory. An optimal heat output to the plenum chamber and the air-conditioned room was determined based on two kinds of criterion functions. The first one requires small deviation in room air temperature from a set-point value and low energy consumption. It is shown that the optimized control is to store heat through the whole storage time and to increase storage rate gradually with time. As the second case, a criterion that both a deviation of operative temperature from a set-point temperature and the energy consumption should be minimized was adopted. The room air temperature was a little high and the cooling load during storage time was reduced, compared with the results when a criterion function considering only the room air temperature is used.

Experimental Analysis of Radiative Heat Interchange on Furnace Exit Plane of a Steam Boiler

  • Ahn, Kook-Young;Antonovsky, Vjacheslav-Ivanovich
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.239-247
    • /
    • 2001
  • Measured radiative heat fluxes on the furnace exit plane of a heavy duty power boiler of steam output 1650 T/h are discussed. A high-ash pulverized bituminous coal was used. Such measurements are necessary to improve heat fluxes inside a steam boiler furnace was manufactured. An extra small heat radiation sensor was placed in the water cooled head of the probe. The sensor had no direct contact with furnace gases and measured only the radiant energy. There was no exposure to convective heat transfer. With the radiometric probe, one can obtain a spherical indicatrix of radiation intensity as well as hemispherical radiative heat flux incident on any surface passing through a measuring point inside the furnace. Thus, the quantity of radiation energy, passing through the furnace exit plane, to the convective heating surfaces and the quantity of radiation energy going in the opposite direction were measured. A formula for relative radiative heat flux on the furnace exit plane has been proposed.

  • PDF

A Calculation Method on Heat Flux from Ondol Floor Surface (온돌면(溫突面)의 방열량(放熱量) 산정방법(算定方法)에 관한 연구(硏究))

  • Sohn, Jang Yeul;Ahn, Byung Wook;Pang, Seung Ki
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.1 no.2
    • /
    • pp.173-181
    • /
    • 1989
  • Until recently there was a lack of reliable performance data for the design and operation of Ondol heating systems. This paper presents a calculation method on heat flux from Ondol floor surface. Total heat flux from floor consists of radiation and convection component. In order to analyse the characteristics of both radiation and convection heat flux, each surface temperature is measured and several temperatures near each wall are measured vertically and horizontally in a practical Ondol heating space. Radiation heat flux is calculated and analysed by Gebhart's Absorption Factor Method with the consideration of instantaneous radiant exchanges. Convection heat output is derived from the vertical temperature profiles near floor. The vertical temperature profiles could be expressed by nonlinear regression equation models and convection coefficients could be estimated by the equations. As a result, radiation, convection and total heat flux are suggested by the expression of difference between floor surface and room air temperature.

  • PDF

Improving Electromagnetic Compatibility of the Infrared Flame Detector (적외선식 불꽃감지기의 전자파 적합성 개선)

  • Song, Hyun-Seon;Lee, Yeu-Yong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.1
    • /
    • pp.88-95
    • /
    • 2014
  • The infrared, flame detector uses to detect fire situation from the characteristics of fire sources radiant energy. But it is able to malfunction on account of susceptible to interference of various surrounding waves. This paper is designed 6 independent PCB-boards to minimize the closed loops of siginal circuit. Also considering the interaction of electric and magnetic fields, this paper is designed protecting circuit of current and voltage output to reduced electromagnetic interference. And this paper is improving electromagnetic susceptibility by ferrite bid, capacitor filter and grounding circuits.