• Title/Summary/Keyword: Radial Switch

Search Result 32, Processing Time 0.029 seconds

Loop Current Calculation based on Voltage Angle Difference at Tie Switch for Switching Plan Validation in Distribution System Operation (상시개방점 양단전압 측정값을 이용한 배전선로 루프운전 가능 여부 판단 방법)

  • Son, Juhwan;Lim, Seongil
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.7
    • /
    • pp.14-21
    • /
    • 2015
  • Distribution systems are operated in radial structure, but temporal loop structure could be founded the live load transfer. Main purposes of reconfiguration of distribution network are load balancing, loss minimization and voltage drop maintaining. In the loop structure, huge loop current can be flowed between two substations in case of large voltage angle difference. Protection devices of distribution line can be triped by this huge loop current. So, precise calculation of loop current is very important for secure switching. This paper proposes a novel calculation method of loop current using the voltage angle differences measured at the tie switches. Feasibility of the propose method has been verified by various case studies based on Matlab simulation.

Application of Genetic Algorithm for Loss Minimization in Distribution Systems (배전계통에서 손실 최소화를 위한 유전자 알고리즘의 적용)

  • Jeon, Young-Jae;Kim, Hoon;Lee, Seung-Youn;Son, Hag-Sig;Park, Soung-Ok;Kim, Jae-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.156-158
    • /
    • 2000
  • This paper presents a efficient algorithm for loss reduction of distribution system by automatic sectionalizing switch operation in distribution systems of radial type. To apply genetic algorithm to reconfiguration of distribution system, in this paper we propose the string type and efficient reconfiguration procedure. We also discuss the more elaborate search techniques of solution space as well as the simple genetic algorithm. The experimental results show that the proposed genetic algorithm have the ability to search a good solution.

  • PDF

Reconfiguration of Distribution System Using Tabu Search (타부탐색을 이용한 배전계통 재구성)

  • Jeon, Young-Jae;Choi, Seung-Kyoo;Kim, Hoon;Park, Koung-Jong;Kim, Jae-Chul
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1422-1424
    • /
    • 1999
  • This Paper Presents a efficient algorithm for loss reduction of distribution system by automatic sectionalizing switch operation in distribution systems of radial type. To apply tabu search to reconfiguration of distribution system, in this Paper we Propose the several move methods and efficient reconfiguration procedure. We also discuss the tabu search techniques of diversifying the search of solution space as well as the simple tabu search. The experimental results show that the proposed tabu search techniques have the ability to search a good solution.

  • PDF

Substation Bus Voltage Angle Calculation Method Using Voltage Angle Difference Measured at the Tie Switch in the Distribution Line (배전선로 상시연계점 측정 전압 위상차를 이용한 변전소 모선 위상각 추정 방법)

  • Son, Ju-Hwan;Lim, Seong-Il
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.1
    • /
    • pp.9-15
    • /
    • 2016
  • Distribution networks are operated in radial fashion during the normal state. Loop configuration is also required temporally in case of live load transfer among the adjacent feeders. Voltage angles of each substation buses are very important data in order to calculate power flow of the loop structured distribution feeders. This paper proposes substation bus voltage angle calculation method using voltage angle difference measured at the normally open tie switches. Simulation case studies using Matlab simulink have been performed to establish feasibility of proposed method.

The study of Arc-voltage characteristics in Radial & Axial Manetic Field Type Vacuum Switch (횡.종자계형 진공 스위치의 아크 전압 특성)

  • Lee, Tae-Ho;Seo, Kil-Soo;Lee, Hong-Sik;Rim, Geun-Hee;Huh, Chang-Su
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1769-1771
    • /
    • 2002
  • 정전형 펄스파워시스템에서 핵심은 투입 스위치라고 해도 과언이 아니다. 이러한 투입 스위치 중 진공 아크를 이용하는 스위치로는 로렌츠력을 이용 아크를 회전시켜 전극의 손상을 억제한 횡자계형과 전극의 축방향으로 자계를 발생시켜 아크가 확산되도록 함으로써 z-pinch에 의한 전극 손상을 감소시키는 종자계형으로 대별 할 수 있다. 본 논문에서는 고전압/대전류용 횡자계형과 종자계형 진공스위치의 동작특성을 파악하기위해 아크전압-전류 특성에 대해서 기술하였다. 횡자계형 전극과 종자계형 전극을 동크롬(75:25 [wt%])으로 제작하여 진공 챔버 내에서 실험을 통해 아크 전압과 전류를 측정하였으며, 이를 통해 아크 저항과 손실 전력을 구하였다.

  • PDF

Implementation of Simulated Annealing for Distribution System Loss Minimum Reconfiguration (배전 계토의 손실 최소 재구성을 위한 시뮬레이티드 어닐링의 구현)

  • Jeon, Young-Jae;Choi, Seung-Kyo;Kim, Jae-Chul
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.4
    • /
    • pp.371-378
    • /
    • 1999
  • This paper presents an efficient algorithm for loss reduction of distribution system by automatic sectionalizing switch operation in large scale distribution systems of radial type. Simulated Annealing algorithm among optimization techniques can avoid escape from local minima by accepting improvements in cost, but the use of this algorithm is also responsible for an excessive computation time requirement. To overcome this major limitation of Simulated Annealing algorithm, we may use advanced Simulated Annealing algorithm. All constaints are divided into two constraint group by using perturbation mechanism and penalty factor, so all trail solutions are feasible. The polynomial-time cooling schedule is used which is based on the statistics calculation during the search. This approaches results in saving CPU time. Numerical examples demonstrate the validity and effectiveness of the proposed methodology.

  • PDF

Application of Simulated Annealing for Loss Reduction in Distribution System (배전 계통에서 손실 감소를 위한 시뮬레이티드 어닐링의 적용)

  • Jeon, Young-Jae;Choi, Seung-Kyoo;Kim, Hun;Lee, Seung-Youn;Kim, Jae-Chul
    • Proceedings of the KIEE Conference
    • /
    • 1998.11a
    • /
    • pp.335-337
    • /
    • 1998
  • This paper presents a efficient algorithm for loss reduction of distribution system by automatic sectionalizing switch operation in distribution systems of radial type. Simulated Annealing can avoid escape from local minima by accepting improvements in cost, but the use of this algorithm is also responsible for an excessive computation time requirement. To overcome this major limitation of Simulated Annealing Algorithm, we may use advanced Simulated Annealing Algorithm. Numerical examples demonstrate the validity and effectiveness of the proposed methodology.

  • PDF

Study on Wear of Journal Bearings during Start-up and Coast-down Cycles of a Motoring Engine - II. Analysis Results (모터링 엔진의 시동 사이클 및 시동 정지 사이클에서 저어널베어링의 마모 연구 - II. 해석 결과)

  • Chun, Sang Myung
    • Tribology and Lubricants
    • /
    • v.31 no.3
    • /
    • pp.125-140
    • /
    • 2015
  • In this paper, we present the results of the wear analysis of journal bearings on a stripped-down single-cylinder engine during start-up and coast-down by motoring. We calculate journal bearing wear by using a modified specific wear rate considering the fractional film defect coefficient and load-sharing ratio for the asperity portion of a mixed elastohydrodynamic lubrication (EHL) regime coupled with previously presented graphical data of experimental lifetime linear wear in radial journal bearings. Based on the calculated wear depth, we obtain a new oil film thickness for every crank angle. By examination of the oil film thickness, we determine whether the oil film thickness at the wear scar region is in a mixed lubrication regime by comparing dimensionless oil film thickness, h/σ, to 3.0 at every crank angle. We present the lift-off speed and the crank angles involved with the wear calculation for bearings #1 and #2. The dimensionless oil film thickness, h/σ, illustrates whether the lubrication region between the two surfaces is still within the bounds of the mixed lubrication regime after scarring of the surface by wear. In addition, we present in tables the asperity contact pressure, the real minimum film thickness at the wear scar region, the modified specific wear rate, and the wear angle, α, for bearings #1 & #2. To show the real shape of the oil film at wear scar region, we depict the actual oil film thickness in graphs. We also tabulated the ranges of bearing angles related with wear scar. We present the wear volume for bearings #1 and #2 after one turn-on and turn-off of the engine ignition switch for five kinds of equivalent surface roughness. We show that the accumulated wear volume after a single turn-on and turn-off of an ignition switch normally increases with increasing surface roughness, with a few exceptions.

Analysis of Vibrating and Electromagnetic Performance According to Switching Angle in SRM (스위칭 각의 변화에 따른 SRM 전자기적 특성 및 진동 특성 분석)

  • Lee, Ji-Yeong;Ha, Gyeong-Ho;Lee, Geun-Ho;Jo, Jae-Ok;Hong, Jeong-Pyo;Gang, Do-Hyeon
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.8
    • /
    • pp.434-440
    • /
    • 2002
  • Switched Reluctance Motor (SRM) has been not commonly used because of the severe noise and vibration, although it has many advantages as solidity and economical efficiency. The origin of the acoustic noise and vibration in SRM's can be broadly classified into two types, mechanical and magnetic. Therefore this paper verifies the origin of vibration induced by radial magnetic forces from various experiments, and then studies the relationship between the output and vibration characteristics of SRM according to switch-on and off angles. Acceleration, torque and efficiency is measured by changing switching angles. From the comparison and analysis of the experimental results, a proper switching angle is presented for both satisfying electric performance and reducing vibration.

Comparison of the Operational Speed of Hard-wired and IEC 61850 Standard-based Implementations of a Reverse Blocking Protection Scheme

  • Mnguni, Mkhululi Elvis Siyanda;Tzoneva, Raynitchka
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.740-754
    • /
    • 2015
  • This paper focuses on the reverse blocking busbar protection scheme with aim to improve the speed of its operation and at the same time to increase operational reliability, flexibility and stability of the protection during external and internal faults by implementation of the extended functionality provided by the IEC61850 standard-based protective Intelligent Electronic Devices (IEDs). The practical implementation of the scheme by the use of IEC 61850 standard communication protocol is investigated. The proposed scheme is designed for a radial type of a distribution network and is modeled and simulated in the DigSILENT software environment for various faults on the busbar and its outgoing feeders. A laboratory test bench is built using three ABB IEDs 670 series that are compliant with the IEC 61850 standard, CMC 356 Omicron test injection device, PC, MOXA switch, and a DC power supplier. Two types of the reverse blocking signals between the IEDs in the test bench are considered: hard wired and Ethernet communication by using IEC 61850 standard GOOSE messages. Comparative experimental study of the operational trip response speeds of the two implementations for various traffic conditions of the communication network shows that the performance of the protection scheme for the case of Ethernet IEC 61850 standard-based communication is better.