맥진기 결과에 대한 판독자간의 판독 일치율 비교 연구 (Comparative Studies on the Concordance Rate of Pulse Condition Interpretation between Interpreters and Pulse Analyser)

  • 강세영;장인수;김락형
    • Korean Journal of Acupuncture
    • /
    • 제28권4호
    • /
    • pp.91-99
    • /
    • 2011
  • Objectives : The purpose of our investigation is to determine degrees of concordance rate among interpreters. Furthermore, we have examined how much concordance rate to come out when beginners have been compared with the pulse analyzer. Methods : Thirty-nine volunteers were enrolled for this study. These subjects took a 5-minute rest in a sitting position as instructed by the protocol. As they were not allowed to move or speak, radial artery pulse conditions were measured on the lower arm of each subject by means of the pulse analyzer under investigation. Two Korean medical doctors, who did not know the status of default pulse conditions, were also instructed to intuitively choose the most corresponding one in comparison with 13 default pulse conditions. Subsequently, we investigated results between interpreters as well as results between interpreter and pulse analyzer. Results : The total concordance rate, with similar concordance rates being included, between interpreters, between interpreter A and pulse analyzer, and between interpreter B and pulse analyzer was 56.4%, 79.5%, and 71.8% respectively. In faint fine weak pulse(微細弱脈) case, interpreter A and B selected 6 and 7 cases respectively, matched the concordance rate 5, and corresponded separately with the pulse analyzer interpreting 8 cases. Conclusions : In case of skipping pulse 2(促2脈), short pulse(短脈), faint fine weak pulse(微細弱脈), the concordance between interpreters also matches with results drawn from the pulse analyzer. The concordance rate goes higher in proportion with such smaller pulse conditions as faint fine weak pulse(微細弱脈) and short pulse(短脈).

Piezo Film Sensor를 이용한 생체 정보 검출 (Detection the Biomedical Information using the Piezo Film Sensor)

  • 이한욱;서환;정원근;장두봉;이건기
    • 한국정보전자통신기술학회논문지
    • /
    • 제3권3호
    • /
    • pp.14-21
    • /
    • 2010
  • 유비쿼터스 헬스케어 환경을 위해서는 생체 정보를 실시간으로 정확하게 측정하는 것이 중요할 뿐만 아니라, 이러한 생체 정보 측정 장치는 저전력으로 설계되어져야 한다. 본 논문에서는 지금까지 사용되어 오던 손가락 프로브의 불편함을 없애기 위해 피에죠 필름 센서를 이용하여 손목의 요골 동맥으로부터 심장의 동기 신호인 맥파를 측정하였다. 본 논문에서는 두장의 피에죠 필름 센서를 이용하여 맥파신호와 동잡음 참조 신호를 추출하여 적응 잡음 제거기에 적용함으로써, 동잡음 제거된 맥파 신호를 얻을 수 있었다. 동잡음 제거된 맥파 신호를 이용하여 생체 정보를 얻을 수 있었다.

  • PDF

유한 요소법을 이용한 맥진 파형의 자기장 변화 분석 (Analysis of Magnetic Field Variation for Pulse Wave by Using Finite Element Method)

  • 박태영;이상석
    • 한국자기학회지
    • /
    • 제24권3호
    • /
    • pp.90-96
    • /
    • 2014
  • 요골동맥의 움직임에 따라 손목의 "관" 위치에 놓인 영구자석이 요동함으로 자기장의 변화를 생성하였다. 맥동에 의존하는 자기장을 감지하는 홀소자가 구비된 집게형맥진기의 출력신호인 맥진파형 특성을 분석하였다. 유한요소법으로 전산모사한 자기장 파형과 실제 맥진 파형의 시간 특징점들은 거의 일치하였다. 한 개의 원통 소형 영구자석의 자기장 분포의 변화를 감지하는 홀소자 집게형맥진기 시뮬레이터를 제작하여 재현성과 유효성 있는 한방진단기기로 활용하는 기틀을 마련하였다.

토노메트리 측정 관점에서의 부침맥 고찰 (Review on Floating Pulse and Sinking Pulse in the View Point of Tonometric Measurement)

  • 이전;이유정;유현희;이혜정;김종열
    • 한국한의학연구원논문집
    • /
    • 제14권2호
    • /
    • pp.113-119
    • /
    • 2008
  • In pulse diagnosis, floating pulse and sinking pulse are frequently used for diagnosis about where disease is located and how much severe they are. However, in what mechanism floating pulse and sinking pulse arise is not known well. There are two point of views on substantial of floating pulse and sinking pulse. The first one is the floating and sinking degrees is the expression on the depth of pulsation. And, the second one is floating and sinking pulse is based on the response of pulsation to the indent pressure on radial artery. In this paper, we discussed these two opinions in the view point of tonometric measurement. The process for diagnosis on floating pulse and sinking pulse is similar to the tonometric measurement for non invasive blood pressure or intraocular pressure. We modelled the degrees of depth of pulsation with different indent pressures for initial pulsation feeling and different slopes of indent pressure lines. From this modelling, we can confirm the effect of pulsation depth on P-H curve, that is, in the model where lower pulsation is assumed, the shift of optimal indent pressure to the right was observed. The response of pulse pressure to the indent pressure was tried to be modelled with the degrees of mean blood pressure. Consequently, we tried to model the phenomenon of floating and sinking pulse for the first. And, from this modelling, we can get abundant understanding on how floating and sinking pulse can be caused. In the further study, we want to prove the suitability of this tonometric measurement based modelling with various studies including ultrasound measurement for the depth of pulsation in different EMI subjects.

  • PDF

손목 피부 온도에 의한 맥센서 어레이(array)의 신호 변동 및 보정 (Signal Change and Compensation of Pulse Pressure Sensor Array Due to Wrist Surface Temperature)

  • 전민호;전영주;김영민
    • 센서학회지
    • /
    • 제26권2호
    • /
    • pp.141-147
    • /
    • 2017
  • A pressure sensor in pulse measurement system is a core component for precisely measuring the pulse waveform of radial artery. A pulse sensor signal that measures the pulse wave in contact with the skin is affected by the temperature difference between the ambient temperature and skin surface. In this study, we found experimentally that the signal changes of the pressure sensors and a temperature sensor were caused by the temperature of the wrist surface while the pressure sensor was contacted on the skin surface for measuring pulse wave. To observe the signal change of the pulse sensor caused by temperature increase on sensor surface, Peltier device that can be kept at a set temperature was used. As the temperature of Peltier device was kept at $35^{\circ}C$ (the maximum wrist temperature), the device was put on the pulse sensor surface. The temperature and pressure signals were obtained simultaneously from a temperature sensor and six pressure sensors embedded in the pulse sensor. As a result of signal analysis, the sensor pressure was decreased during temperature increase of pulse sensor surface. In addition, the signal difference ratio of pressure and temperature sensors with respect to thickness of cover layer in pulse sensor was increased exponentially. Therefore, the signal of pressure sensor was modified by the compensation equation derived by the temperature sensor signal. We suggested that the thickness of cover layer in pulse sensor should be designed considering the skin surface temperature.

동맥맥파의 특징점 검출 알고리즘 개선에 관한 연구 (Improvement of a characteristic point detection algorithm of arterial pulse)

  • 전영주;이전;김종열;이낙범;임재중
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1916-1917
    • /
    • 2007
  • Aortic AIx(augmentation index) has been used to measure aortic stiffness and evaluate ventricular load quantitatively. Algorithm for the detection of augmentation point gradually increases the differential order to detect inflection point rather than detects the distinctive point that appears after a specific time. Developed algorithm for AIx is proved to provide more accurate results than the ones developed by previous studies with the deviation from $-11.5{\pm}14.34$ points to $-3.75{\pm}1.26$ points. Results could provide the basis for the measurement of aortic stiffness using easily-measurable radial artery pulse waves, and could be extended to develop a system for early diagnosis of various vascular diseases.

  • PDF

한국인 성인 남성의 체질별 맥상 특성에 관한 연구 (A Study on the Sasang Constitutional Differences in the Pulse Wave of Korean Healthy Adult Men)

  • 김호석;유현희;이시우
    • 한국한의학연구원논문집
    • /
    • 제13권2호통권20호
    • /
    • pp.71-74
    • /
    • 2007
  • Background : Sasang Constitutional Medicine (SCM) is the field of traditional Korean medicine that emphasize four constitutional types for diagnosis and treatment. Appearance, personalities and pathological characteristics are main factors of Sasang constitutional classification. Previous studies carried out by the pulse analyzer showed that the pulse wave can discriminate these types. In addition, It was reported that the pulse wave are affected by age and sexuality. In this study, we investigated the pulse wave characteristics related Sasang constitution types in control group regarding their age and sexuality. Subjects and Method : Two hudred and eighteen volunteers participated in this study: healthy men in $20{\sim}49$ years old. Participants were interviewed and examined to evaluate their health condition and Sasang constitution type. Then they were tested with pulse analyzer when they ere stabilized. The pulse at the radial artery just beside styloid process was measured, because this area is landmark for pulse diagnosis in oriental medicine. 3-D Mac pulse analyzer (Daeyo Medi Co. Ansan. Korea) was used in this study. We analyzed main features of pulse waves with the Sasang condtitution types by the SPSS for Windows (ver 12.0). Results : There was significant difference between Taeum and other types in contact pressure as weil as in coefficient of floating and sinking pulse. Conclusion : By analyzing pulse waves of healthy adult men. we found significant differences exist between Taeum and other types. These pulse differences may characterize Taeum type, and it will be helpful for the evaluation of Taeum type.

  • PDF

토노메트리 방식 맥파 측정의 가압 각도에 따른 변동성 평가 (Variation Factor Assessment of Radial Artery Pulse by the Tonometry Angle of the Pulse Pressure Sensor)

  • 정창진;조정희;전민호;전영주;김영민
    • 센서학회지
    • /
    • 제25권2호
    • /
    • pp.138-142
    • /
    • 2016
  • A pulse measurement by tonometry provides useful information for diagnosis, including not only blood pressure and heart rate but also parameters for estimating a condition of the cardiovascular system. Currently, various pulse measurement devices based on the tonometry have been developed. A reliability of these devices is determined by a positioning technic between the sensor and the blood vessel and a controlling technique of the pressurization level. An angle of the sensor for the pulse measurement seems to be highly related with a measured signal, however, the objective studies for this issue have been not published. In this paper, the variation of the pulse signals by tonometry direction was experimentally assessed according to the angle of the sensor. In order for guaranteeing the repeatability of the experiment, we used a pulse generator device, which can generate human pulse signal by using silicon tube and fluid pump, and developed a structure for precise adjustment of the angle and the pressurization level of the sensor. The angle of the sensor was acquired by an inclinometer, which was attached at the opposite side of the sensor. As results, a coefficient of variation (CV) of a maximum amplitude (MA) of the pulse wave was largely increased over the angle range of $-9{\sim}9^{\circ}$. Furthermore, the changes of the pulse shape showed different aspects according to the sign of the angle tilted along the blood vessel. It is expected that the results of this study can be helpful for developing more precise pulse measurement devices based on the tonometry and applying in clinic.

광센서와 압력센서를 이용한 맥박측정시스템 개발 (Development of Blood Pressure Measuring System using piezoelectric and photo sensor)

  • 최영숙;김경재;홍우헌;류정탁
    • 한국산업정보학회논문지
    • /
    • 제14권5호
    • /
    • pp.149-154
    • /
    • 2009
  • 사람들의 평균 수명이 늘어남으로써 건강에 대한 관심도가 매우 높아지고 있다. 그에 따라 사람들은 자신의 몸 상태를 체크하며 주기적으로 자신의 건강상태를 확인하기 위해 정기검진을 받는다. 그러나 평소 자신의 맥박이나 혈압의 체크를 통하여 건강관리 및 질병예방이 가능하다. 따라서 본 논문에서는 간편하게 얻을 수 있으면서도 기본적이고 유용한 정보를 많이 가지고 있는 맥박신호를 혈액량에 따라 투과율의 변화를 측정할 수 있는 광센서를 이용한 방법과 압전 센서를 사용하여 손목의 요골동맥의 압력을 측정하여 맥박을 측정할 수 있는 휴대용 맥박측정 시스템을 구현하였으며 두 방법으로 제작된 시스템을 비교연구 하였다.