• Title/Summary/Keyword: Rad7

Search Result 168, Processing Time 0.029 seconds

Seismic Performance Evaluation of Beam-Column Connection for Panel Zone Strength (패널존의 강도비에 따른 기둥-보 접합부의 내진성능 평가)

  • Kim, Sung-Young;Shin, Chang-Hoon
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.7 no.1 s.24
    • /
    • pp.11-20
    • /
    • 2007
  • The study proposes the method to cancel the scallop to avoid fracture of the circumstance of the scallop at H shape column-to-beam connection and reinforce at beam flange two faces with the cover plates and rib. A total of four specimens were tested to enhance seismic performance of building structure by reducing the frequency of stress concentration and preventing the brittle fracture of scallop. For this purpose, four full-scale test specimens were made and loaded with quasi-static reversed cyclic loading. The main analytical parameters are panel-zone-strength ratio, yield strengths, initial stiffness, total plastic rotation, contribution of each element to total plastic rotation and energy dissipation capability. For the specimens tested under repeated loading, the experimental result was satisfied with seismic performance requirement as the Special Moment Frames (SMF). The analysis results show that all of the test specimens were found to have good performance to 4% story drift and satisfied the criteria for the plastic roation capacity of SMFs that is 0.03 rad. according to the 1997 AISC seismic provision.

How Effective Are Radiation Reducing Gloves in C-arm Fluoroscopy-guided Pain Interventions?

  • Kim, Ah Na;Chang, Young Jae;Cheon, Bo Kyung;Kim, Jae Hun
    • The Korean Journal of Pain
    • /
    • v.27 no.2
    • /
    • pp.145-151
    • /
    • 2014
  • Background: The physician's hands are close to the X-ray field in C-arm fluoroscopy-guided pain interventions. We prospectively investigated the radiation attenuation of Proguard RR-2 gloves. Methods: In 100 cases, the effective doses (EDs) of two dosimeters without a radiation-reducing glove were collected. EDs from the two dosimeters-one dosimeter wrapped with a glove and the other dosimeter without a glove-were also measured at the side of the table (Group 1, 140 cases) and at a location 20 cm away from the side of the table (Group 2, 120 cases). Mean differences such as age, height, weight, radiation absorbed dose (RAD), exposure time, ED, and ratio of EDs were analyzed. Results: In the EDs of two dosimeters without gloves, there were no significant differences ($39.0{\pm}36.3{\mu}Sv$ vs. $38.8{\pm}36.4{\mu}Sv$) (P = 0.578). The RAD ($192.0{\pm}182.0radcm^2$) in Group 2 was higher than that ($132.3{\pm}103.5radcm^2$) in Group 1 (P = 0.002). The ED ($33.3{\pm}30.9{\mu}Sv$) of the dosimeter without a glove in Group 1 was higher than that ($12.3{\pm}8.8{\mu}Sv$) in Group 2 (P < 0.001). The ED ($24.4{\pm}22.4{\mu}Sv$) of the dosimeter wrapped with a glove in Group 1 was higher than that ($9.2{\pm}6.8{\mu}Sv$) in Group 2 (P < 0.001). No significant differences were noted in the ratio of EDs ($73.5{\pm}6.7%$ vs. $74.2{\pm}9.3%$, P = 0.469) between Group 1 and Group 2. Conclusions: Proguard RR-2 gloves have a radiation attenuation effect of 25.8-26.5%. The radiation attenuation is not significantly different by intensity of scatter radiation or the different RADs of C-arm fluoroscopy.

Are Head Impacts Safe during Youth Soccer Game Practice? (유소년 축구 경기에서 발생하는 머리 충격은 안전할까?)

  • O'Sullivan, David;Kwak, Myung-Hoo;Kim, Yun-Sik;Jeong, Hee Seong
    • Korean Journal of Applied Biomechanics
    • /
    • v.30 no.2
    • /
    • pp.155-163
    • /
    • 2020
  • Objective: This study to identify the mechanism of head impact that occurs during youth soccer game with regard to head injuries in sports. Method: Ten male subjects (age: 10.0±2.0 yrs.) were participated during 10 soccer practices spread out over a time period of 10 weeks. During each soccer game, the participants agreed and wore the X-Patch (wireless accelerometer, gyroscopes). The X-Patch records the head impact mechanics, such as peak linear acceleration (PLA), peak rotational acceleration (PRA), peak rotational velocity (PRV), Head Injury Criterion (HIC), and the location of impact. Results: A total of 501 impacts to the head were measured over the 10 soccer games, PLA 17.8±10.4 g, PRA 3168±2442 rad/s2; PRV 16.1±10.6 rad/s; HIC 11.7±34.2. The severity of impact was classified into 3 ranges; low 10~39 g (482 impacts); medium 40~69 g (17 impacts); and high >69 g (2 impacts). There are no significant differences in PLA and HIC (p=0.08, p=0.15), however PRA and PRV show the differences (p<.05) between each of the participants. For the analysis comparing between the soccer games, there are no significant differences in PLA, PRA, PRV and HIC (p=0.11, p=0.13, p=0.14, p=0.05). Conclusion: Our results indicated that there were significant differences between athletes, especially in terms of rotational acceleration, whereas there were significant differences in linear and rotational based variable between each of the soccer games. Although the vast majority of impacts were below 39 g there were 2 potentially dangerous impacts above 69 g. It is important that future research continuous to measure head impact mechanics during soccer to help understand head injury mechanisms to ensure the safety of athletes.

THYMOMA -A Review of Fourteen Patients- (흉선종 - 14명에 대한 치료 효과 -)

  • Kim S. K.;Lee H. S.;Cho K. H.;Suh C. O.;Kim G. E.
    • Radiation Oncology Journal
    • /
    • v.3 no.1
    • /
    • pp.29-33
    • /
    • 1985
  • 흉선종은 비교적 드문 종양으로 알려져 있다. 예후를 알 수 있는 가장 중요한 인자는 수술시 육안적인 종양의 침윤정도이며, 치료는 수술에 의한 종양의 제거가 무엇보다 중요하고, 방사선 치료 역시 수출 후 국소적 계발의 방지를 위해 쓰이고 있다. 근치적 목적의 방사선 치료도 수술이 어려운 경우에 시행되고 있는 형편이다. 저자들은 1977년 1월부터 1984년 12월까지 세브란스병원 연세암센타 치료방사선과에서 흉선종 진단받고 치료한 14명의 환자를 후향성 분석에 의해 다음과 같은 결과를 얻었다. 1. 6명의 환자$(14\%)$가 근무력증을 나타냈다. 2. 주변조직의 침윤이 $86\%(12/14)$에서 관찰되었다. 3. $43\%$에서 육안적 완전 절제를 시행하였고 $14\%$에서 부분결제, 그리고 $43\%$에서는 생검만 시행 하였다. 4. 수술 후 혹은 근치적 목적의 방사선치료는 8명의 환자에서 시행하였으며 그중 현재 5명은 생존(4년, 2.8년, 1.6년, 1.4년, 1.3년), 3명은 사망(1년, 0.6년, 0.6년)하였다. 5. 방사선 치료선량은 대체료 $4,000\~4,500rad(1950\~7,000rad)$를 전후 흉곽 부위에 외부 조사하였다.

  • PDF

Evaluation for Effectiveness of Radon Mitigation on Dwellings and Public Buildings in Korea (건축물 유형에 따른 라돈 저감 효과 평가)

  • Lee, DongHyun;Ryu, Seung-Hun;Jo, JungHeum;Seo, SungChul
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.4
    • /
    • pp.518-527
    • /
    • 2014
  • Objectives: The adverse health effects attributed to exposure to radon have been well known over the world. However, the efforts for prevention and mitigation of radon have not been taken in Korea so far. The purpose of this study was to evaluate the effectiveness of mitigation methods applied for various types of houses and public buildings with high level of radon. Methods: Based on the results of "National Radon Survey" performed by the National Institute of Environmental Research(NIER) in 2010-2012, we selected 30 candidate buildings consisting of 20 houses and 10 public buildings with greater than $148Bq/m^3$ of radon level. We measured the concentration of radon in 30 buildings, using E-PERMs and RAD-7 during January to March of 2013. More than five E-PERMs and one RAD-7 per house were installed for seven days. Ten houses and five public buildings were finally chosen to be mitigated after mainly considering the level of radon and the location of buildings nationwide. Three mitigation methods such as Sealing, two types of Active Ventilation(window-shaped and wall-typed ventilations), and Active Soil Depressurization(ASD) were applied, and the concentrations of radon were measured before and after mitigation, respectively. To evaluate the effectiveness of mitigation methods, reduction rates of radon were calculated and Wilcoxon's signed-rank test was performed. Results: The mean concentration of 15 buildings just before radon mitigation was $297.8Bq/m^3$, and most of the buildings were located in Gangwon, Chungbuk, Chungnam, and Daegu areas(73.3%), and built in 1959-1998. The level of radon decreased from 48% to 90% and kept the below recommendation limit of $148Bq/m^3$ after installation of radon mitigation. Among mitigation methods applied, the reduction rate(58.7-90.4%) of radon attributed to ASD was the greatest than that of other methods, followed by Active Ventilation(48.4-78.4%) and Sealing(<22%). The effectiveness of radon reduction by window-shaped Active Ventilation(63.2-75.2%) was relatively better than that of wall-typed Active Ventilation(48.4-54.3%). Conclusions: The results of this study indicate that ASD could be more effective for radon mitigation. Moreover, our findings would be background information in future for making the strategy for radon mitigation nationwide, as well as for developing Korean-version of mitigation techniques according to types of dwellings in Korea.

Standard Measurement Procedure for Soil Radon Exhalation Rate and Its Uncertainty

  • Seo, Jihye;Nirwono, Muttaqin Margo;Park, Seong Jin;Lee, Sang Hoon
    • Journal of Radiation Protection and Research
    • /
    • v.43 no.1
    • /
    • pp.29-38
    • /
    • 2018
  • Background: Radon contributing about 42% of annual average dose, mainly comes from soil. In this paper, standard measurement procedures for soil radon exhalation rate are suggested and their measurement uncertainties are analyzed. Materials and Methods: We used accumulation method for estimating surface exhalation rate. The closed-loop measurement system was made up with a RAD7 detector and a surface chamber. Radon activity concentrations in the system were observed as a function of time, with data collection of 5 and 15-minute and the measurement time of 4 hours. Linear and exponential fittings were used to obtain radon exhalation rates from observed data. Standard deviations of measurement uncertainties for two approaches were estimated using usual propagation rules. Results and Discussion: The exhalation rates (E) from linear approach, with 30 minutes measurement time were $44.8-48.6mBq{\cdot}m^{-2} {\cdot}s^{-1}$ or $2.14-2.32atom{\cdot}cm^{-2}{\cdot}s^{-1}$ with relative measurement uncertainty of about 10%. The contributions of fitting parameter A, volume (V) and surface (S) to the estimated measurement uncertainty of E were 59.8%, 30.1% and 10.1%, in average respectively. In exponential fitting, at 3-hour measurement we had E ranged of $51.6-69.2mBq{\cdot}m^{-2} {\cdot}s^{-1}$ or $2.46-3.30atom{\cdot}cm^{-2}{\cdot}s^{-1}$ with about 15% relative uncertainty. Fitting with 4-hour measurement resulted E about $51.3-68.2mBq{\cdot}m^{-2} {\cdot}s^{-1}$ or $2.45-3.25atom{\cdot}cm^{-2}{\cdot}s^{-1}$ with 10% relative uncertainty. The uncertainty contributions in exponential approach were 75.1%, 13.4%, 8.7%, and 2.9% for total decay constant k, fitting parameter B, V, and S, respectively. Conclusion: In obtaining exhalation rates, the linear approach is easy to apply, but by saturation feature of radon concentrations, the slope tends to decrease away from the expected slope for extended measurement time. For linear approach, measurement time of 1-hour or less was suggested. For exponential approach, the obtained exhalation rates showed similar values for any measurement time, but measurement time of 3-hour or more was suggested for about 10% relative uncertainty.

Radon Hazard Review of Spilled Groundwater and Tap Water in Incheon Metropolitan City Subway Station (인천광역시 지하철 역사 내 지하수 및 수돗물의 라돈 위해성 검토)

  • Lee, Yoo-Sang;Lee, Sang-Bok;Kang, Min-Seok;Jeong, Dong-Ha;Kim, Jin-Hong;Oh, Yoon-Sik;Choi, Se-Rin;Park, Jeong-Soo;Kim, Sungchul
    • Journal of radiological science and technology
    • /
    • v.44 no.6
    • /
    • pp.671-677
    • /
    • 2021
  • Interest in the everyday hazards of radon has recently increased as such, this study attempted to examine the dangers of radon in spilled groundwater by comparing the radon concentrations of the drained groundwater and tap water used in recirculating systems in Incheon Subway restrooms. At five stations of Incheon Subway Line 1 and three stations of Line 2, drained groundwater is recirculated and used in restrooms for toilet flushing. Stations restroom tap water for hand washing that used as a control and the measured values of each were compared. With the cooperation of Incheon Transportation Corporation, samples of spilled groundwater and tap water were collected sealed to prevent contact with the air, and a DURRIDGE RAD7 was used as the experimental equipment. The collected samples were subjected to radial equilibration for approximately 3.5 h, at which the radon concentration reached its maximum, and then calculated as 10 measurements using the RAD7 underwater radon measurement mode. In all eight stations, the radon concentration in tap water was lower than the recommended amount. However, in an average of 7 out of the eight stations, the radon concentration in the effluent groundwater was 100 times higher than that in tap water. Since high radon concentrations in groundwater runoff can be harmful to humans, and there is no accurate standard for radon concentrations in domestic water, it is necessary to continuously monitor radon in water and prepare a guidance of recommended values.

Clinical analysis of ostium secundum atrial septal defect (이차공형 심방중격결손증의 임상적 고찰)

  • 이종태
    • Journal of Chest Surgery
    • /
    • v.17 no.4
    • /
    • pp.607-613
    • /
    • 1984
  • Thirty seven patients with ostium secundum atrial septal defect, operated from January, 1976 to September, 1984 at the Department of Thoracic and Cardiovascular Surgery, Kyungpook National University Hospital, were given clinical assessment. The following results were obtained. 1.Ostium secundum atrial septal defect was comprised of 18% of congenital heart disease. Their mean age was 15.7\ulcorner.42. Sex ratio [male:female] was 1:1.1. 2.Most frequent clinical symptom was dyspnea on exertion occurred in 26 patients [76.5%]. Only one patient had no symptom [2.9%]. 3.Pre-operative EKG findings revealed RVH in 61.8%, ICRBBB in 29.4%, and RAD in 41.2%. 4.Mean value of systolic pulmonary arterial pressure in patients over 20 years old was 37.8\ulcorner4.4mmHg and it was 28.1\ulcorner10.2mmHg in patients under 20 years old, but the difference between two groups was not statistically significant. 5. In large defect group [>3cm in diameter], Qp/Qs was significantly increased than small defect group [<3cm in diameter], but systolic pulmonary arterial pressure and Rp/Rs were not different between two groups. 6. Overall operative mortality was 5.4%.

  • PDF

Design of phase tracking feedback compensator for stabilization of single mode fiber-optic Mach-Zehnder interferometer (단일모드 광섬유 Mach-Zehnder간섭계의 안정화를 위한 추적궤환 보상기의 설계)

  • 이기완;오문수;홍봉식
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1989.10a
    • /
    • pp.547-552
    • /
    • 1989
  • Single mode optical fiber interferometeric sensors using phase tracking homodyne detection are typically susceptible to environmentally induced temperature fluctuations and other types of disturbances. In this paper compensator is described, which is a simple and effective phase tracking feedback electronic circuit must be output signal stabilized to achieve maximln sensitivity and linearity of Mach-Zehnder fiber-optic interferomter in the presence of differential phase drift. The phase tracking range of the piezoelectric cylinder in the reference arm is .+-.3.7.pi.rad, and the probe mass about 1 gram in the sensing ann was used for measurements of the gravity acceleration.

  • PDF

An Inner-spherical Continuously Variable Transmission for Electric Bicycles

  • Park, Moon-Woo;Lee, Hyoung-Woo;Park, No-Gill
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.9 no.1
    • /
    • pp.7-11
    • /
    • 2008
  • A new continuously variable transmission (CVT) for electric bicycles was developed using a traction drive mechanism with inner and outer spherical rotors. This electric bicycle CVT permits three propulsion modes: human-power only, motor-power only, or a combination of motor power and human power. In addition, the electric bicycle CVT has high power efficiency, large torque capacity, improved drivability, and good packageability. A prototype was manufactured based on a conceptual design, a performance analysis, and a detailed design. This prototype has a rated power of 250 W and input motor speed of 20 rad/s for an overall speed ratio in the range 0.3-1.2. A bench test was conducted to measure the power transmission performance of the prototype.