• 제목/요약/키워드: Rad7

검색결과 168건 처리시간 0.028초

Power Generating Performance of Photovoltaic Power System for Greenhouse Equipment Operation (온실설비 작동용 태양광발전시스템의 발전 성능 분석)

  • Yoon, Yong-Cheol;Bae, Yong-Han;Ryou, Young-Sun;Lee, Sung-Hyoun;Suh, Won-Myung
    • Journal of Bio-Environment Control
    • /
    • 제18권3호
    • /
    • pp.177-184
    • /
    • 2009
  • For the purpose of reducing the cost for greenhouse operation by acquiring the electric power necessary for it, this study installed a solar photovoltaic system on the roof of the building adjacent to green-houses and experimentally examined the quantity of power generation based on weather conditions. The results of the study are as per the below: The maximum, average and minimum temperature while the experiment was conducted was $0.4{\sim}34.1,\;-6.1{\sim}22.2$, and $-14.1{\sim}16.7^{\circ}C$ respectively, and the solar radiation was $28.8MJ{\cdot}m^{-2}$ (maximum), $14.9MJ{\cdot}m^{-2}$ (average), and $0.6MJ{\cdot}m^{-2}$ (minimum). The quantity of electric power didn't increase in proportion to the quantity of solar radiation and instead, it was almost consistent around 750W. Daily maximum, average and minimum consumption of electric power was 5.2kWh, 2.5kWh and 0kWh respectively. Based on the average electric power consumption of the system used for this experiment, it was sufficient in case the capacity and the working time of a hot blast heater are small, but it was short in case they are big. In case the capacity of the hot blast heater is big, the average electric power quantity will be sufficient for array area $21m^2$, about three times of the present area. In summer when the temperature of the array becomes high, the generation of electric power didn't increase in proportion to the quantity of solar radiation, but this experiment result shows a high correlation between two factors (coefficient of correlation 0.84).

Evaluation of IH-1000 for Automated ABO-Rh Typing and Irregular Antibody Screening (ABO 및 RhD 혈액형 검사와 비예기항체 선별검사를 위한 자동화장비 IH-1000의 평가)

  • Park, Youngchun;Lim, Jinsook;Ko, Younghuyn;Kwon, Kyechul;Koo, Sunhoe;Kim, Jimyung
    • The Korean Journal of Blood Transfusion
    • /
    • 제23권2호
    • /
    • pp.127-135
    • /
    • 2012
  • Background: Despite modern advances in laboratory automated medicine, work-process in the blood bank is still handled manually. Several automated immunohematological instruments have been developed and are available in the market. The IH-1000 (Bio-Rad Laboratories, Hercules, CA, USA), a fully automated instrument for immunohematology, was recently introduced. In this study, we evaluated the performance of the IH-1000 for ABO/Rh typing and irregular antibody screening. Methods: In October 2011, a total of 373 blood samples for ABO/Rh typing and 303 cases for unexpected antibody screening were collected. The IH-1000 was compared to the manual tube and slide methods for ABO/Rh typing and to the microcolumn agglutination method (DiaMed-ID system) for antibody screening. Results: For ABO/Rh typing, concordance rate was 100%. For unexpected antibody screening, positive results for both column agglutination and IH-1000 were observed in 10 cases (four cases of anti-E and c, three of anti-E, one of anti-D, one of anti-M, and one of anti-Xg) and negative results for both were observed in 289 cases. The concordance rate between IH-1000 and column agglutination was 98.7%. Sensitivity and specificity were 90.9% and 99.3%, respectively. Conclusion: The automated IH-1000 showed good correlation with the manual tube and slide methods and the microcolumn agglutination method for ABO-RhD typing and irregular antibody screening. The IH-1000 can be used for routine pre-transfusion testing in the blood bank.

Evaluation of the Automated Immunohematology Analyzer DAYMATE M (혈액은행 자동화 검사장비 DAYMATE M의 수행능 평가)

  • Yoo, Jaeeun;Yu, Hain;Choi, Hyunyu;Lee, Gyoo Whung;Song, Young-Sun;Lee, Seungok;Jekarl, Dong Wook;Kim, Yonggoo
    • Laboratory Medicine Online
    • /
    • 제7권4호
    • /
    • pp.163-169
    • /
    • 2017
  • Background: An automated immunohematology analyzer, DAYMATE M (DAY Medical, Switzerland), has been recently developed. The potential of this analyzer to improve test results has been evaluated. Methods: A total of 300 blood samples from Seoul St. Mary's hospital and Incheon St. Mary's hospital were tested for ABO and RhD typing. In addition, 336 antibody screening test (AST) samples and 82 patients treated with hematopoietic stem cell transplantation (HSCT) were included. AST results by DAYMATE M were compared with those obtained by a manual method using DS-Screening II (Bio-Rad Laboratories, Switzerland) and red blood cells from Selectogen (Ortho-Clinical diagnostics Inc., USA). Results: Of the 300 patients enrolled, 87, 73, 79, and 61 had type A, B, O, and AB blood, respectively. The concordance rate was 99.9% for cell typing and 97.0% for serum typing. One discordant case was classified as type B instead of AB, and six discordant serum-typing cases were type A, but classified as type AB. Among the 336 AST samples, the concordance rate was 93.2%. From 136 positive cases, six were discordant. Within the 82 HSCT-treated patients, the concordance rate for ABO blood typing was 92.2%. Among the six discordant cases, DAYMATE M typed four cases as donor type where the standard method typed them as the recipient blood type. Conclusions: The DAYMATE M automated immunohematology analyzer performs reliably for ABO and RhD typing, as well as for ASTs and on samples from patients treated with HSCT.

Structural Behavior Evaluation of NRC Beam-Column Connections (NRC 보-기둥 접합부의 구조적 거동 평가)

  • Jeon, Ji-Hwan;Lee, Sang-Yun;Kim, Seung-Hun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • 제26권1호
    • /
    • pp.73-80
    • /
    • 2022
  • In this study, details of NRC beam-column connections were developed in which beam and columns pre-assembled in factories using steel angles were bolted on site. The developed joint details are NRC-J type and NRC-JD type. NRC-J type is a method of tensile joining with TS bolts to the side and lower surfaces of the side plate of the NRC column and the end plate of the NRC beam. NRC-JD type has a rigid joint with high-strength bolts between the NRC beam and the side of the NRC column for shear, and with lap splices of reinforcing bar penetrating the joint and the beam main reinforcement for bending. For the seismic performance evaluation of the joint, three specimens were tested: an NRC-J specimen and NRC-JD specimen with NRC beam-column joint details, and an RC-J specimen with RC beam-column joint detail. As a result of the repeated lateral load test, the final failure mode of all specimens was the bending fracture of the beam at the beam-column interface. Compared to the RC-J specimen, the maximum strength of the specimen by the positive force was 10.1% and 29.6% higher in the NRC-J specimen and the NRC-JD specimen, respectively. Both NRC joint details were evaluated to secure ductility of 0.03 rad or more, the minimum total inter-story displacement angle required for the composite intermediate moment frame according to the KDS standard (KDS 41 31 00). At the slope by relative storey displacemet of 5.7%, the NRC-J specimen and the NRC-JD specimen had about 34.8% and 61.1% greater cumulative energy dissipation capacity than the RC specimen. The experimental strength of the NRC beam-column connection was evaluated to be 30% to 53% greater than the theoretical strength according to the KDS standard formula, and the standard formula evaluated the joint performance as a safety side.

Development and Assessment Individual Maximum Permissible Dose Method of I-131 Therapy in High Risk Patients with Differentiated Papillary Thyroid Cancer (물리학 선량법을 이용한 갑상선암의 개인별 최대안전용량 I-131 치료법 개발과 유용성 평가)

  • Kim, Jeong-Chul;Yoon, Jung-Han;Bom, Hee-Seung;JaeGal, Young-Jong;Song, Ho-Chun;Min, Jung-Joon;Jeong, Heong;Kim, Seong-Min;Heo, Young-Jun;Li, Ming-Hao;Park, Young-Kyu;Chung, June-Key
    • The Korean Journal of Nuclear Medicine
    • /
    • 제37권2호
    • /
    • pp.110-119
    • /
    • 2003
  • Purpose: Radioiodine (I-131) therapy is an effective modality to reduce both recurrence and mortality rates in differentiated thyroid cancer. Whether higher doses shows higher therapeutic responses was still debatable. The purpose of this study was to validate curve-fitting (CF) method measuring maximum permissible dose (MPD) by a biological dosimetry using metaphase analysis of peripheral blood lymphocytes. Materials and Methods: Therapeutic effects of MPD was evaluated in 58 patients (49 females and 9 males, mean age $50{\pm}11$ years) of papillary thyroid cancer. Among them 43 patients were treated with ${\Leq}7.4GBq$, while 15 patients with ${\geq}9.25GBq$. The former was defined as low-dose group, and the latter high-dose group. Therapeutic response was defined as complete response when complete disappearance of lesions on follow-up I-131 scan and undetectable serum thyroglobulin levels were found. Statistical comparison between groups were done using chi-square test. P value less than 0.05 was regarded as statistically significant. Results: MPD measured by CF method using tracer and therapeutic doses were $13.3{\pm}1.9\;and\;13.8{\pm}2.1GBq$, respectively (p=0.20). They showed a significant correlation (r=0.8, p<0.0001). Exposed doses to blood measured by CF and biological methods were $1.54{\pm}0.03\;and\;1.78{\pm}0.03Gy$ (p=0.01). They also showed a significant correlation (r=0.86, p=0.01). High-dose group showed a significantly higher rate of complete response (12/15, 80%) as compared to the low-dose group (22/43, 51.2%) (p=0.05). While occurrence of side effects was not different between two groups (40% vs. 30.2%, p=0.46). Conclusion: Measurement of MPD using CF method is reliable, and the high-dose I-131 therapy using MPD gains significantly higher therapeutic effects as compared with low-dose therapy.

Two-dimensional gel Electrophoresis of Helicobacter pylori for Proteomic Analysis

  • Jung, Tae-Sung;Kang, Seung-Chul;Choi, Yeo-Jeong;Jeon, Beong-Sam;Park, Jeong-Won;Jung, Sun-Ae;Song, Jae-Young;Choi, Sang-Haeng;Park, Seong-Gyu;Choe, Mi-Young;Lee, Byung-Sang;Byun, Eun-Young;Baik, Seung-Chul
    • The Journal of the Korean Society for Microbiology
    • /
    • 제35권2호
    • /
    • pp.97-108
    • /
    • 2000
  • Two-dimensional gel electrophoresis (2-DE) is an essential tool of proteomics to analyse the entire set of proteins of an organism and its variation between organisms. Helicobacter pylori was tried to identify differences between strains. As the first step, whole H. pylori was lysed using high concentration urea contained lysis buffer [9.5 M Urea, 4% CHAPS, 35 mM Tris, 65 mM DTT, 0.01% SDS and 0.5% Ampholite (Bio-Rad, pH 3-10)]. The extract ($10\;{\mu}g$) was rehydrated to commercially available immobilised pH gradient (IPG) strips, then the proteins were separated according to their charges as the first dimensional separation. The IPG strips were placed on Sodium Dodecyl Sulfate-Polyacrylamide Gel Electrophoresis (SDS-PAGE) to separate according to molecular mass of the proteins as the second dimension. The separated protein spots were visualised by silver staining in order to compare different expression of proteins between strains. Approximately 120 spots were identified in each mini-protein electrophoresised gel, furthermore about 65 to 75 spots were regarded as identical proteins in terms of pI value and molecular weight between strains used. In addition, distinct differences were found between strains, such as 219-1, Y7 and Y14, CH150. Two representative strains were examined using strips which had pH range from 4 to 7. This strips showed a number of isoforms which were considered large spots on pH range 3-10. Furthermore, the rest of spots on pH 4-7 IPG strips appeared very distinctive compared to broad range IPG strips. 2-DE seems to be an excellent tool for analysing and identifying variations between H. pylori strains.

  • PDF

Radioprotective Effect of Methylene Blue: 2. Electron Microscopy of the Effect of Methylene Blue on the Liver and Heart of Rats following Gamma-Irradiation (Methylene Blue의 방사선방어결과 2. Methylene Blue가 $\gamma$선에 조사한 흰줘의 간 및 심장조직에 미치는 전자현미경적 연구)

  • Sang Yul Nam;Seung Han Chang
    • The Korean Journal of Zoology
    • /
    • 제12권4호
    • /
    • pp.114-122
    • /
    • 1969
  • Electron microscopic examination of the liver and heart tissues of methylene blue-treated rats before gamma-irradiation was observed in this study. 1. It was observed severe alteration and degeneration of organelles: accumulation of glycogen particles, severe swollen mitochondria, and broken endoplasmic reticulum in liver tissue of saline-treated rat(control) opposed by emthylene blue-treated rat at 64 and 212 hours following gamma-irradiation. 2. Heart muscles of both methylene blue-treated and saline-treated rats showed no significant alterations, but it was observed that slightly elongated mitochondria with broken cristae and some of vacuoles as well as increased glycogen particles in sarcoplasmic reticulum at 212 hours following gamma-irradiation. 3. It may be considered that methylene blue greatly reduces the sensitivities of rats to gamma-irradiation.

  • PDF

THE CHANGE OF THE INITIAL DYNAMIC VISCO-ELASTIC MODULUS OF COMPOSITE RESINS DURING LIGHT POLYMERIZATION (광중합 복합레진의 중합초기 동적 점탄성의 변화)

  • Kim, Min-Ho;Lee, In-Bog
    • Restorative Dentistry and Endodontics
    • /
    • 제34권5호
    • /
    • pp.450-459
    • /
    • 2009
  • The aim of this study was to measure the initial dynamic modulus changes of light cured composites using a custom made rheometer. The custom made rheometer consisted of 3 parts: (1) a measurement unit of parallel plates made of glass rods, (2) an oscillating shear strain generator with a DC motor and a crank mechanism, (3) a stress measurement device using an electromagnetic torque sensor. This instrument could measure a maximum torque of 2Ncm, and the switch of the light-curing unit was synchronized with the rheometer. Six commercial composite resins [Z-100 (Z1), Z-250 (Z2), Z-350 (Z3), DenFil (DF), Tetric Ceram (TC), and Clearfil AP-X (CF)] were investigated. A dynamic oscillating shear test was undertaken with the rheometer. A certain volume ($14.2\;mm^3$) of composite was loaded between the parallel plates, which were made of glass rods (3 mm in diameter). An oscillating shear strain with a frequency of 6 Hz and amplitude of 0.00579 rad was applied to the specimen and the resultant stress was measured. Data acquisition started simultaneously with light curing, and the changes in visco-elasticity of composites were recorded for 10 seconds. The measurements were repeated 5 times for each composite at $25{\pm}0.5^{\circ}C$. Complex shear modulus G*, storage shear modulus G', loss shear modulus G" were calculated from the measured strain-stress curves. Time to reach the complex modulus G* of 10 MPa was determined. The G* and time to reach the G* of 10 MPa of composites were analyzed with One-way ANOVA and Tukey's test ($\alpha$ = 0.05). The results were as follows. 1. The custom made rheometer in this study reliably measured the initial visco-elastic modulus changes of composites during 10 seconds of light curing. 2. In all composites, the development of complex shear modulus G* had a latent period for $1{\sim}2$ seconds immediately after the start of light curing, and then increased rapidly during 10 seconds. 3. In all composites, the storage shear modulus G" increased steeper than the loss shear modulus G" during 10 seconds of light curing. 4. The complex shear modulus of Z1 was the highest, followed by CF, Z2, Z3, TC and DF the lowest. 5. Z1 was the fastest and DF was the slowest in the time to reach the complex shear modulus of 10 MPa.

Rheological and Pasting Properties of Potato Flour Dispersions (감자가루 분산액의 유변학적 및 페이스팅 특성 분석)

  • Heo, Hyemi;Won, Chuin;Jin, Yong-Ik;Chang, Dong-Chil;Kim, Misook;Lee, Youngseung;Chang, Yoon Hyuk
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • 제44권9호
    • /
    • pp.1407-1413
    • /
    • 2015
  • The objective of this study was to investigate the rheological and pasting properties of potato flour dispersions at different concentrations (3, 4, 5, 6, and 7%, w/w). A potato cultivar 'Goun', used in this study, was developed by Highland Agriculture Research Center, RDA. Potato flour dispersions showed shear-thinning behaviors (n=0.44~0.51) at $25^{\circ}C$. Apparent viscosity (${\eta}_{a,100}$), consistency index (K), and yield stress (${\sigma}_{oc}$) significantly increased with an increase in potato flour concentration. Storage modulus (G') and loss modulus (G") significantly increased, whereas complex viscosity (${\eta}^*$) was significantly reduced with increasing frequency (${\omega}$) from 0.63 to 63.8 rad/s. Magnitudes of G' and G" were significantly increased with elevation of potato flour concentration. G' values were considerably greater than G" over the entire range of frequency (${\omega}$) with a high dependence on ${\omega}$. Cox-Merz rule was not applicable to potato flour dispersions. Rapid Visco Analyzer data showed that peak viscosity, trough viscosity, breakdown viscosity, final viscosity, and set back viscosity of samples significantly increased with an increase in potato flour concentration.

Design and Implementation of a Distribute Multimedia System (분산 멀티미디어 스트리밍 시스템 설계 및 구현)

  • Kim, Sang-Kuk;Shin, Hwa-Jong;Kim, Se-Young;Shin, Dong-Kyoo;Shin, Dong-Il
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 한국정보처리학회 2000년도 추계학술발표논문집 (상)
    • /
    • pp.677-680
    • /
    • 2000
  • 웹이 등장하면서 지금까지 인터넷 상에서 텍스트와 이미지를 이용하여 정보를 표현하고 전달하는 방법이 가장 많이 사용되어왔다. 그러나 웹 관련 기술의 비약적인 발달과 네트워크 속도의 증가 및 인터넷의 급속한 보급으로 단순한 텍스트와 이미지 중심의 HTML 문서를 이용한 정보의 전달이 아닌 멀티미디어 데이터를 이용한 정보의 표현과 전달이 점차 증대되고 있다. 이에 따라 멀티미디어 데이터를 전송하기 위한 스트리밍 프로토콜도 등장하였다. 최근에는 컴퓨터의 성능 증가 및 네트워크 속도의 증가(초고속 통신 서비스의 보급)에 의해 멀티미디어 데이터의 전송이 가능하게됨으로써 기존의 공중파나 CATV 방송국의 형태 지니고 인터넷 상에서 실시간 생방송 서비스와 VOD(Video On Demand) 서비스를 제공하는 인터넷 방송국이 급속하게 생겨나고 있다.[11] 인터넷 방송은 동영상과 오디오의 실시간 전달을 가능하게 하는 멀티미디어 스트리밍 기술과 멀티미디어를 실시간으로 전송할 수 있는 실시간 전송 프로토콜을 기반으로 발전하고 있다. 인터넷 상에서 멀티미디어 스트리밍 서비스를 하는 대부분의 인터넷 방송은 스트리밍 서버로서 RealNetworks사의 RealSystem과 Microsoft사의 WMT(Windows Media Technologies)를 사용하고 있다. 본 논문은 Real Server와 WMT의 비교 분석을 통해 실시간 전송 프로토콜을 지원하고, 멀티미디어 스트리밍 기술을 지원하는 자바를 기반으로 한 분산 서버 구조의 스트리밍 서버, 서버간의 부하를 제어하는 미들웨어, 멀티미디어 스트림을 재생할 수 있는 클라이언트를 설계하고 구현한다. 방법에 대해서 자세히 살펴보고 실제 SQL Server 7.0 환경에서 구축된 공간 엔진 및 OLE DB 제공자 컴포넌트의 구현 예에 대하여 살펴볼 것이다. 혈액내방사선 조사량이 안전용량 범위(200rad)에 속하며 48시간 후 체내잔류량은 서양인과 큰 차이가 없었다.비출현의 소견을 보이는 악성종양 환자의 골 신티그람 53개중 44개 (83.0%)에서 척추 및 늑골에 미만성, 또는 다발성 침습이 관찰되었다. 또 골전이 부위를 두개골, 척추, 견대부, 늑골, 골반, 사지의 근위부 장골의 6개 부위로 나누어 분석할 경우 49개(92.5%)에서 3부위 이상에 전이가 발견되었고, 35개(66.0%)에서 4부위 이상에 전이가 발견되었으며, 5부위 이상, 6개 부위에 모두 전이가 발견된 것은 각각 20개 (37 7%), 11개(20.8%)이었다. 이상의 성적으로 보아 악성종양 환자의 골 신피그라피에서 신장 영상의 비출현은 종양의 광범위한 골전이를 간접적으로 시사하는 소견으로 생각된다. 여러 악성종양중 전립선암에서 신장 영상 비출현의 빈도가 가장 높았으며, 특히 위암에서 골전이 및 신장 영상 비출현의 빈도가 높음은 주목할 만한 것이라 하겠다.출한 결과 인,규소 증가와 자가영양성 미소플랑크톤(ANP)증가에 미치는 요인이 해안과 외해에서 동일하게 가장 큰 설명력을 보였다. N:P 비도 해안에서 36.4, 외해에서 32.6을 보이고 있어 인이 상당히 부족한 것으로 나타났다. 따라서 조사해역은 인이 식물플랑크톤 성장에 중요한 제한요인으로 작용하고 있다고 판단된다.의 회전. 전위력의 강도, 적용시점, 그리고 키, 체중등의 신체적 요인 등이 있으나 능숙한 기계사

  • PDF