• 제목/요약/키워드: Rabbit tibia

검색결과 47건 처리시간 0.025초

티타늄금속과 골조직의 계면에 관한 연구 -골과 임플란트 계면에서의 Ti-ion의 거동에 대하여(1)- (ON THE INTERFACE BETWEEN TITANIUM METAL AND BONE TISSUE -Ti-ion leakage from bone and implant interface(1)-)

  • 조성암;조광헌;서조영
    • 대한치과보철학회지
    • /
    • 제33권2호
    • /
    • pp.354-357
    • /
    • 1995
  • The secondary ion of titanium from commercially pur titanium implant which installed at Rabbit tibia. Was analyzed by Secondary lon Mass Spectroscopy. And we detected about 3476 ppm ion from $10-50{\mu}m$ distance from interface.

  • PDF

Bone Response to Anodized Titanium Implants in Rabbits

  • Lee, Jae-Hyun;Lee, Cheol-Won;Kim, Chang-Hyen;Pyo, Sung-Woon
    • Journal of Korean Dental Science
    • /
    • 제4권1호
    • /
    • pp.26-32
    • /
    • 2011
  • Purpose: The quality of implant surface is one of the factors that influence wound healing of implant site and subsequently affect osseointegration. The objective of modification of the surface properties of an implant is to affect the biological consequence. The purpose of this study is to evaluate the biologic response of osseous tissue to anodized implants. Materials and Methods: Two machined titanium implants for control group were installed in a tibia of each rabbit and two anodized implants for test group were installed in the other tibia of each rabbit. At the moment the implants were installed, resonance frequency analysis (RFA) values were measured. After healing periods of 1, 2, 3, and 7 weeks, the implants were uncovered and RFA values were measured again. Removal torque was measured for one implant in the test group and one implant in the control group. Histological evaluation was executed in the other implants. Results: Both of test group and control group have the tendency of greater RFA change rate and removal torque value as healing periods became longer, but were statistically insignificant (P>0.05). However, in the case of the same healing period, the test group tended to have greater RFA change rate and removal torque than the control group (P<0.05). More active new bone formation from endosteal surface was noted on the anodized surface than machined surface in specimen after 1 week. There were no significant differences between the test group and control group in histological evaluations. Conclusion: In summary, the anodized surface showed slightly favorable results and it is postulated that it may facilitate improved stability in bone.

EVALUATION OF BONE RESPONSE BY RESONANCE FREQUENCY ANALYSIS OF ANODIZED IMPLANTS

  • Roh Hyun-Ki;Heo Seong-Joo;Rhyu In-Chul
    • 대한치과보철학회지
    • /
    • 제43권6호
    • /
    • pp.745-750
    • /
    • 2005
  • Statement of problem. Resonance frequency analysis has been increasingly served as a non-invasive and objective method for clinical monitoring of implant stability. Many clinical studies must be required for standardized data using RFA. Purpose. This study was performed to evaluate RFA value changes in two anodized implant groups. Material and method. Among a total of 24 implants, twelve screw shaped implants as a test group (H2-R8.5) were manufactured, which had a pitch-height of 0.4 mm, an outer diameter of 4.3 mm, a length of 8.5 mm, and external hexa-headed, were turned from 5 mm rods of commercially pure titanium (ASTM Grade IV, Warantec Co., Seoul, Korea), and another twelve implants as a control group were $Br{\aa}nemark$ Ti-Unite MK4 (diameter 4.0 mm, length 8.5 mm). Each group was installed in tibia of rabbit. Two implants were placed in each tibia (four implants per rabbit). Test two implants were inserted in right side and control two in left side. ISQ values were measured using $Osstell^{TM}$ (Integration Diagnostics Ltd. Sweden) during fixture installation, and 12 weeks later and evaluated the RFA changes. Results. Mean and SD of baseline ISQ values of test group were $75.0{\pm}3.4$ and $68.7{\pm}8.1$ for control group. Mean and SO of ISQ values 12 weeks after implant insertion were $73.2{\pm}4.7$ for test group and $72.6{\pm}3.9$ for control group. There were no statistically significant differences between groups in ISQ values after 3 months (P>0.05). From the data, RFA gains after 3 months were calculated, and there was statistically significant difference between groups (P<0.05). Conclusion. Although there were RFA changes between groups, implant stability after experimental period shows alike tendency and good bone responses.

REMOVAL TORQUE OF BICORTICALLY STABILIZED RBM(RESORBABLE BLAST MEDIA) PIN IMPLANTS IN RABBIT TIBIA

  • Kim, Kwon-Sik;Suh, Kyu-Won;Lee, Richard Sung-Bok;Ryu, Jae-Jun
    • 대한치과보철학회지
    • /
    • 제44권6호
    • /
    • pp.722-733
    • /
    • 2006
  • Statement of problem. The use of small diameter implants having less than 3 mm in diameter were restricted because of lack of bonding strength to bone. Purpose. The purpose of this study was to observe how much resorbable blast media pin implants increase the binding force to the bone compared to machined transitional pin implants by measuring removal torque, and whether they can be used as final implants for replacement of small diameter teeth. Material and method. Fifteen rabbits were used in this study. Two kinds of implants (resorbable blast media pin implants and machined transitional pin implants) were inserted in each tibia bicortically. After healing time of 2, 4 and 8 weeks, the removal torque values were recorded and the rabbits were sacrificed for histological analysis. Linear finite element method analyses were conducted to compare bicortical fixation with monocortical fixation. Result and conclusion. Within the limitation of this in vivo study, the following conclusions were drawn: 1) The removal torque value of RBM pin implants showed statistically significant increase compared to machined pin implants at 2, 4, and 8 weeks respectively (p<0.05). 2) The removal torque value of RBM pin implants at 2, 4, and 8 weeks was increased statistically significantly with time (p<0.05). 3) Bicortical fixation showed better stress distribution compared with monocortical fixation in a linear finite element method analysis. 4) RBM pin implants are not recommended as transitional implants because they showed a lot of bone fracture in histologic specimens.

COMPARISON BETWEEN $TIUNITE^{TM}$ AND ANOTHER OXIDIZED IMPLANT USING THE RABBIT TIBIA MODEL

  • Yeo, In-Sung;Lee, Jai-Bong;Han, Jung-Suk;Kim, Sung-Hun;Yang, Jae-Ho
    • 대한치과보철학회지
    • /
    • 제45권3호
    • /
    • pp.339-344
    • /
    • 2007
  • Statement of problem. Various anodic oxidation techniques can be applied to dental implant surfaces. But the condition for optimal anodized surfaces has not been described yet. Purpose. The purpose of this investigation was to compare an implant that was oxidized by another method with $TiUnite^{TM}$ through resonance frequency analysis and histomorphometry. Material and methods. Turned (control), $TiUnite^{TM}$ and another oxidized fixtures, which used $Ca^{2+}$ solution for anodic oxidation, were placed in the tibiae of 5 New Zealand White rabbits. The bone responses were evaluated and compared by consecutive resonance frequency analysis once a week for 6 weeks and histomorphometry after a healing period of 6 weeks. Results. At the first week, both oxidized implants showed significantly higher implant stability quotient (ISQ) values than the control. No significant differences in resonance frequency analysis were found between the two oxidized groups for 6 weeks. The means and standard deviations of bone-to-implant contact (BIC) ratios were $71.0{\pm}4.2$ for $TiUnite^{TM}$, $67.5{\pm}10.3$ for the $Ca^{2+}$-based oxidation fixture, $22.8{\pm}6.5$ for the control. Both oxidized implants were significantly superior in osseointegration to the turned one. There was, however, no statistically significant difference between the two oxidized implants. Conclusion. $TiUnite^{TM}$ and the $Ca^{2+}$-based oxidation fixture showed superior early bone response than the control with respect to resonance frequency analysis and histomorphometry. No significant differences between the oxidized groups, however, were found in this investigation using the rabbit tibia model.

내부냉각(內部冷却) 골천공시(骨穿孔時) 냉각수(冷却水)의 온도(溫度)에 따른 골조직(骨組織)의 병리조직학적(病理組織學的) 변화(變化) (HISTOPATHOLOGIG CHANGES OF THE BONE ON DRILLING WITH DIFFERENT TEMPERATURE SALINE USING INTERNAL IRRIGATION)

  • 박상준;김태규
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제12권3호
    • /
    • pp.8-22
    • /
    • 1990
  • This study was performed to evaluate the histopathologic changes of the rabbit tibial compact bone using internal irrigation with both cold and room - temperature saline on drilling. The medial surface of the rabbit tibia was drilled with specially designed pilot drill (2.0mm in diameter) at 300 rpm. When drilling, two different temperature salines were injected (experimental group I : $4^{\circ}C$ saline, experimental goup Ⅱ : room - temperature saline). And the control group was drilled without cooling agent. The three rabbits in each two experimental and control groups were sacrificed 1, 2, 4, and 8 weeks after. The bone tissues including the bony defects were fixed with 10% neurtal buffered formalin, decalcified with formic acid, embedded in paraplast, and sterile sectioned at 5-6${\mu}m$. And then tissue specimens were stained with H - E and observed under light microscope. The results were as follow : The experimental groups showed early bone repair than the control group at all intervals. They underwent the same course of bone repair until 4 weeks. But the experimental group I showed slightly better bone maturation than the experimental group Ⅱ at 8 weeks.

  • PDF

Sandblasted large grit, acid etched 표면처리에 따른 교정용 미니 임플랜트의 제거회전력에 관한 연구 (Removal torque of sandblasted large grit, acid etched treated mini-implant)

  • 오남희;김성훈;국윤아;이근혜;강윤구;모성서
    • 대한치과교정학회지
    • /
    • 제36권5호
    • /
    • pp.324-330
    • /
    • 2006
  • Sandblasted large grit, acid etched(SLA)표면처리 된 교정용 미니 임플랜트와 평활면을 가진 교정용 미니 임플랜트 사이에 제거회전력과 조직학적 소견을 통해 표면처리된 교정용 임플랜트의 임상적 가능성에 대하여 알아보고자 하였다. 실험재료로는 길이가 9.5 mm, 외경이 1.8 mm인 custom made, screw shaped, titanium implants가 사용되었다. 미니 임플랜트는 두개의 군으로 분류되었는데 SLA군은 20개의 SLA 표면처리된 미니 임플랜트이었고, 평활면군은 크기와 형태가 같지만 SLA처리공정이 생략되어 제작된 20개의 미니 임플랜트로 구성되었다. 이들은 10마리 가토의 경골에 식립되었다. 각각의 가토의 우측 경골에는 SLA군의 미니 임플랜트 2개가 식립되었고, 좌측 경골에는 평활면군의 미니 임플랜트 2개가 식립되었다. 각 군에는 식립 직후 Ni-Ti coil spring에 의해 약 150 g의 지속적인 견인력이 주어졌다. 식립 6주 후에 10마리의 가토를 희생하였고, 안정된 상태에서 Ni-Ti coil spring을 제거하였으며 digital torque gauge를 이용하여 제거 회전력을 측정하였다. 식립 6주 후에 SLA군의 경우 (8.29 Ncm) 평활면군 (3.34 Ncm)에 비해 더 높은 평균 제거회전력을 나타내었고 조직학적 소견에서도 screw 하방에서의 신생골 형성이 관찰되었다. SLA 표면처리된 미니 임플랜트는 평활면 미니 임플랜트에 비해 좀 더 강한 교정력에 저항할 수 있을 것으로 예상되었다.

저칼슘식이 투여와 방사선조사가 임프란트의 골유착에 미치는 영향에 관한 실험적 연구 (Osseointegration of Implants in Rabbit Bone with a Low Calcium Diet and Irradition)

  • 김소정;황의환;이상래
    • Imaging Science in Dentistry
    • /
    • 제30권1호
    • /
    • pp.33-48
    • /
    • 2000
  • Purpose : To investigate osseointergration of titanium implants into the tibia of rabbits, which were fed a low calcium diet and irradiated. Materials and Methods : To prepare the experimental model, control group was fed a normal diet and experimental group was fed a low calcium diet for 4 weeks. And then, titanium implants were inserted into the tibia of each rabbit. Experimental group was subdivided into two groups; low calcium diet/non-irradiation group and low calcium diet/irradiation group. The low calcium diet/irradiation group was irradiated with a single absorbed dose of 15 Gy at the 5th postoperative day. At 12, 19, 33, 47, and 61 days after implantation (1, 2, 4, 6, and 8 weeks after irradiation), the bone formation in the bone-implant interface area was examined by light microscopy and fluorescent microscopy. Results and Conclusions: 1. In the control group, there began to form woven bone in the bone-implant interface area at 12 days after implantation. As the experimental time was going on, the amount of bone which was in contact with the implant was increased. 2. In the low calcium diet/non-irradiation group, there began to form woven bone in the bone-implant interface area at 19 days after implantation. Although the amount of bone which was in contact with the implant was increased as the experimental time was going on, the extent of increased bone was weak as compared with control group. 3. In the low calcium diet/irradiation group, there began to form woven bone incompletely in the bone-implant interface area at 19 days after implantation, but there were vascular connective tissues in the bone-implant interface area over the entire experimental period. 4. In the control group and low calcium diet/non-irradiation group, bone labeling bands were observed at 33 days after implantation, which suggests that the bone formation and remodeling was in process, but interstitial bone remodeling was not observed in the low calcium diet/irradiation group.

  • PDF

토끼 경골에서 치과용 임프란트의 RBM 및 SLA 표면처리에 따른 조직계측학적 연구 (HISTOMORPHOMETRIC STUDY OF DENTAL IMPLANTS WITH RBM AND SLA SURFACE IN THE RABBIT TIBIA)

  • 송국현;김일규;장금수;김규남;최진웅
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제32권6호
    • /
    • pp.514-523
    • /
    • 2006
  • The purpose of the present study was to evaluate the effects of several implant surface treatments to the bone formation, by placing Machined implants, 75${\mu}m$ Calcium phosphate-blasted implants and $Al_2O_3$-blasted and acid-etched implants in rabbit tibia through histomorphometric study. Two animals of each group were sacrificed at 2, 4, 8 weeks. The specimens containing the implants were dehydrated and embedded into hard methylmethacrylate plastic. Thereafter, the sections were ground to 50${\mu}m$. The specimens were stained with Villanueva bone stain for a light microscopic study. The results were as follows; 1. When the surface roughness of three different implants was measured by Surfcorder, the Ra of the Machined group, the RBM group and the SLA group was 0.16${\mu}m$, 0.44${\mu}m$, and 1.08${\mu}m$. 2. When examining the surfaces of the implants in the scanning microscope, Machined implant has the smooth surface with a few scratches, RBM implant has the rough surface with curled ridges and valleys, and SLA implant has the rough surface structures such as sharp protruding parts and micropits measuring 1-2${\mu}m$ in diameter. 3. After 2 weeks of implantation, the percentage of bone-to-implant contact of the Machined group, the RBM group and the SLA group was 26.86%, 35.40% and 45.99%. However, its differences between each group decreased during the healing periods. 4. After 2 weeks of implantation, the percentage of bone area inside the threads of the Machined group, the RBM group and the SLA group were 21.55%, 30.43% and 41.18%. However, its difference of bone area between machined group and surface treatment groups was maintained but the difference within the surface treatment groups decreased during the healing periods. In summary, the amount of bone formation in RBM and SLA group was greater than Machined group in early healing stage. These results suggest that RBM and SLA implants can reduce the healing period for osseointegration and may be suitable for early function.

A histomorphometric study of dental implants with different surface characteristics

  • Pak, Hyun-Soon;Yeo, In-Sung;Yang, Jae-Ho
    • The Journal of Advanced Prosthodontics
    • /
    • 제2권4호
    • /
    • pp.142-147
    • /
    • 2010
  • PURPOSE. One of the major keys to achieve successful osseointegration of the implant is its surface properties. The aim of this study was to investigate the bone response to dental implants with different surface characteristics using the rabbit tibia model. Tricalcium phosphate (TCP) coated, anodic oxidized and turned (control) surfaces were compared. MATERIALS AND METHODS. Seventy two implants were placed in the tibia of eighteen rabbits. Nine rabbits were sacrificed at 3 weeks of healing and the remaining nine were sacrificed at 6 weeks of healing. The bone-to-implant contact (BIC) and the bone volume density (BVD) were assessed by light microscope after 3 and 6 weeks of healing. RESULTS. Statistical analysis showed that no significant differences in the BIC and BVD were observed between the different implant surfaces and the control group at 3 weeks and 6 weeks of healing. Data also suggested that the BVD of all the surfaces showed significant difference at 3 and 6 weeks. CONCLUSION. The present study has showed that osseointegration occurred in all investigated types of surface-treated implants. In the current study all of the threads of the implants were observed to calculate BIC and BVD values (instead of choosing some of the threads from the bone cortex for example), which didn't make BIC or BVD percentage values better than in the control group, therefore the clinical relevance of these results remains to be shown.