• 제목/요약/키워드: RTDS(real-time digital simulator)

검색결과 90건 처리시간 0.033초

PSCAD/EMTDC를 이용한 거리계전기 동특성 시험에 관한 컴포넌트 모델 개발 (Development of User-defined Components for Dynamic Test of Distance Relay Models Using PSCAD/EMTDC)

  • 이홍학;이태영;김호표;노장현;강근수;장성훈;이재욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.242-244
    • /
    • 2003
  • The functional test of protection relays is divided into two kind of test types; the steady-state test and dynamic test. Because the steady-state test is comparatively easy, this test is used to test the characteristics of the relaying elements, operating values, resetting values and etc. using equipment such as Doble. But the dynamic test has to be performed on the test environment with RTDS(real time digital simulator) because of the dynamic characteristics of real protection relays. Therefore, it is not usually easy to perform dynamic test of relays using power system simulation tool based on PC(personal computer) such as PSCAD/EMTDC. This paper discusses how to develop and implement a test model and user-defined components that can be performed dynamic test using PSCAD/EMTDC.

  • PDF

ITER AC/DC Converter Control 검증을 위한 Hardware-in-the-Loop Simulation(HILS) System 구축 및 실험 (Implementation and Experiment Result of Hardware-in-the-Loop Simulation(HILS) System for The Verification of ITER AC/DC Converter Control)

  • 서재학;오종석;최정완;신현국;차한주;박인권
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2015년도 추계학술대회 논문집
    • /
    • pp.221-222
    • /
    • 2015
  • ITER AC/DC Converter의 부하는 초전도 코일이며 이에 필요한 컨버터는 총 6종류(2상한:TF, 4상한:PF, CS, VS, CCU/L, CCS)가 있다. 이중 VS 컨버터(${\pm}1050V$, ${\pm}22.5kA$)는 6대가 직렬로 접속되어 운전되고 CS 컨버터(${\pm}1050V$, ${\pm}4.5kA$)는 4대가 직렬로 접속되어 운전한다. 이들 컨버터용 제어기의 개발 단계에서 실 부하상태를 준비하는 것은 어렵기 때문에 $RTDS^{TM}$ (Real Time Digital Simulator)를 이용하여 제어 대상인 High Power 부분과 초전도 코일의 동적 시스템 모델을 HILS(Hardware-in-the-Loop Simulation)로 구축하였다. 본 논문에서는 HILS 구축에 대한 상세한 내용과 이를 활용하여 Control 시스템을 검증한 결과를 서술하였다.

  • PDF

HVDC의 축소형 모델 개발에 관한 연구 (A Study on Development of Scaled-down HVDC Model)

  • 안종보;윤재영;김국헌;이종무;김종문;이기도
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.219-221
    • /
    • 1999
  • HVDC(High Voltage Direct Current) transmission system was constructed between Cheju island and mainland Haenam and has been operating commercially since 1998. But research activities in this area are not so much. That is caused by the facts that HVDC is large scale system and it is not so easy to implement and to test. Though such simulation tools as RTDS(Real Time Digital Simulator) and EMTDC can be useful, these have limitations for actual control and protective system design. Therefore scaled-down HVDC model was developed for the purpose of researches at operating technique, control and protection methods. The design of this model was based on real Cheju-Haenam HVDC system. And additionally faults simulator such as ground fault, short-circuit and change of impedance in transmission line is equipped for analysis of these faults. Control system of the model was implemented fully digitally. So it is very easy for the researchers to develope control and protection algorithm and to test the performance.

  • PDF

초전도 전력케이블의 전력계통 적용을 위한 고장전류 특성에 관한 연구 (A Study on the Fault Current Characteristics for the Utility Application of HTS Power cable)

  • 김재호;박민원;심기덕;조전욱;유인근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.75-76
    • /
    • 2007
  • Several kinds of High Temperature Superconducting(HTS) power cables have already been developed and evaluated for use in the utility power network. HTS power cable is expected to be used as a very powerful energy delivery system supplying electric power for densely populated cities in the near future, because HTS power cable is capable of the high current density delivery with low AC loss and the size effect comparing with the conventional cable whose capacity is same. Before applying the HTS power cable to real utility network system analysis should be carried out by some simulation tools. Hereby the electrical power system analysis is very important for the practical use of HTS power devices. In this paper, authors propose a real-time simulation method which incorporates a real HTS tapes into the simulated 22.9kV utility power network system using Real Time Digital Simulator(RTDS). For the simulation analysis, a test sample of HTS tapes was actually manufactured, and the transient phenomenon of HTS power cable system was analyzed in the simulated utility power network.

  • PDF

RTDS를 이용한 신재생에너지 기반 마이크로그리드 시뮬레이션 해석 (Simulation Analysis of a Renewable Energy Based Microgrid using RTDS)

  • 허세림;김경훈;이효근;황철상;박민원;유인근;박정도;이동영;이상진
    • 전기학회논문지
    • /
    • 제60권12호
    • /
    • pp.2190-2195
    • /
    • 2011
  • Due to enhanced demands on quality, security and reliability of the electric power energy system, a microgrid has become a subject of special interest. In this paper, output characteristics of energy storage system (ESS) with an electric double layer capacitor (EDLC) and battery energy storage system (BESS) of a renewable energy based microgrid were analyzed under grid-connected and islanded operation modes. The microgrid which consists of photovoltaic and wind power turbine generators, diesel generator, ESS with an EDLC, BESS and loads was modeled using real time digital simulator. The results present the effective control patterns of the microgrid system.

주파수 유연화 운영에 따른 발전기 축 비틀림에 관한 연구 (A Study on the Subsynchronous Resonance by Flexible Frequency Operation)

  • 조윤성
    • 조명전기설비학회논문지
    • /
    • 제29권4호
    • /
    • pp.62-68
    • /
    • 2015
  • Subsynchronous Resonance is a condition where the electrical power systems composed of generator and transmission line exchange energy with mechanical turbine-generator system at the frequency of the combined below the subsynchronous frequency. Therefore, the frequency of power systems should be associated with the subsynchronous resonance. This paper describes subsynchronous resonance by flexible frequency operation. It focuses on the characteristics and behavior of subsynchronous resonance. The subsynchronous resonance is being conducted by real-time digital simulator and the IEEE benchmark model for subsynchronous resonance have been utilized for the test systems.

보호 계전기 동특성 테스트를 위한 임피던스 궤적 모델 개발 (Development of Impedance Locus Model for Protective Relay Dynamic Test)

  • 김수남;이재규;이명수;유석구
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권9호
    • /
    • pp.451-459
    • /
    • 2002
  • This paper presents a method for modelling of the impedance locus in order to test the protective relay with dynamic. This paper has the two parts, the first part is the configuration of impedance locus with voltage magnitude, total impedance magnitude and angle. And the second part is the control of the locus speed with deviation of two frequencies. The proposed method is applied to two machine equivalent system with PSCAD/EMTDC to show its effectiveness.

감도행렬기반의 전압제어시스템에 관한 연구 (A Study on the Intelligent Voltage Control System using the Sensitivity Matrix)

  • 이흥재;유원근;임찬호;이경섭;이은재;김태균;신정훈;남수철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.50-51
    • /
    • 2008
  • 최근 구미 선진국에서 빈발하고 있는 전압붕괴로 인한 대형 정전사고의 확률이 점증하고 있어 전압관리가 전력계통의 주요관심사로 대두되고 있으며, 이러한 문제들에 대한 대비가 시급한 실정이다. 전압 및 무효전력의 계층적 전압제어는 이러한 문제점들을 경감시킬 수 있는 방법의 일환으로 이미 유럽의 선진국에서는 2차적 전압제어, 3차적 전압제어 시스템을 개발하여 운영하고 있는 실정이다. 이에 따라 본 연구에서는 지능형 전압제어시스템을 개발하였으며, RTDS(Real Time Digital Simulator)를 통하여 성능을 검증하는 단계에 와 있다. 본 논문에서는 정적 모의를 통해 지능형 전압제어시스템의 효과를 검증하였고, 제주계통을 대상으로 개발된 지능형 전압제어시스템의 동적 특성을 검증 할 예정이다.

  • PDF

실시간 시뮬레이터를 이용한 제주 풍력발전단지 모델구성 (Wind Farm using Real Time Digital Simulator in Jeju Island)

  • 김기석;김현욱;박정수;장길수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.282-283
    • /
    • 2015
  • 세계 각국은 에너지 환경, 안보 및 경제에 능동적으로 대처하기 위해 신재생에너지 개발에 국가적 역량을 집중하고 있으며, 그 중 기술의 완성도 및 경제성이 가장 앞서있는 풍력발전 분야의 참여 비중을 점점 확대하고 있는 추세이다. 그러나 풍력에너지 활용의 효율성, 전력의 품질면에서 1~2기 정도의 풍력발전기의 계통연계는 효과적이지 못하기 때문에, 수기에서 수십기의 대용량 풍력발전기로 구성된 대단위 풍력발전단지를 통해 전력을 생산, 공급하는 것이 바람직하다. 따라서, 본 논문에서는 RTDS 시뮬레이터를 이용하여 제주도 한경풍력발전단지의 실시간 시뮬레이션 환경을 구축할 수 있는 3MW급 DFIG 풍력발전기를 모델링하여, 3MW, 5기로 구성된 풍력발전단지를 RTDS를 이용하여 구현하였다.

  • PDF

초전도 전력기기 적용에 따른 계통보호문제 고찰 (Basic study on the protection of Korean power system applying superconducting devices)

  • 이승렬;윤재영;이병준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.625-626
    • /
    • 2007
  • This study is on the protection system of Korean power system applying superconducting power devices. We investigates firstly protection systems of Korean power system and then do a basic study on the impact of relay systems in the power system with superconducting devices. For the more reliable result, we will carry out relay operation tests in the power system applying superconducting facilities using RTDS(Real Time Digital Simulator) in the future.

  • PDF