• 제목/요약/키워드: RT Simulation

검색결과 154건 처리시간 0.034초

가압열충격을 받는 원자로의 확률론적 파괴해석 (Probabilistic Fracture Analysis of Nuclear Reactor Vessel under Pressurized Thermal Shock)

  • 김지호;김종욱;김종인;박근배
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2004년도 봄 학술발표회 논문집
    • /
    • pp.309-316
    • /
    • 2004
  • A probabilistic structural integrity assessment is performed for a reactor pressure vessel under PTS(Pressurized Thermal Shock). A semi-elliptical finite axial crack is assumed to he in the beltline region(either base metal or weld meta)1 of the reactor vessel inside surface. The selected random variables are initial crack depth, neutron fluence on the vessel inside surface, copper, nickel, and phosphorus content of the vessel material, and RT/sub NDT/. The probabilities of crack initiation or vessel failure where the crack is propagated through vessel wall are calculated. The probabilities obtained with random crack size are compared to these obtained with deterministic us. Since the failure function cannot to explicitly by selected by selected random variables, Monte Carlo Simulation is applied to perform probabilistic analysis The influence of the amount of neutron fluence is also examined to assess the structural reliability for vessel life time.

  • PDF

옥외용 증강현실 시스템의 실사획득장치 개발 (The Development of Real Scences Acquisition System for Outdoor Augmented Reality System)

  • 최태종;김주완허웅
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1998년도 추계종합학술대회 논문집
    • /
    • pp.743-746
    • /
    • 1998
  • In this paper, we developed an outdoor augmented reality system which has remote real scences acquisition ability. The real scenes acquisition system consists of image acquisition system, tracking system, wireless data transceiver and power supply. Tracking system that consists of Tans Vector and RT-20 measures a position and attitude of the CCD camera that attached at the remote control helicopter. Wireless data transceiver system is utilized for data transmission of remote system that of attitude, position information, andreal scenes data that acquired by the CCD camera. Maximum propelling power of remote control helicopter is 15Kg, so we used 7.2V li-ion cell as a power supply for system minimize. As the results of experiment, the developing system presented application possibility of remote information acquisition system such as construction simulation & estimation, broadcasting, tour guide.

  • PDF

Al-Zn-Mg 계 합금의 Creep 거동에 관한 연구 (A Study on the Creep Behaviour of Al-Zn-Mg Alloy)

  • 박종건;최재하
    • 열처리공학회지
    • /
    • 제6권2호
    • /
    • pp.79-88
    • /
    • 1993
  • The static creep mechanism and behaviour of Al-Zn-Mg alloy have been investigated under condition of constant stress tension creep test in the temperature and stress range of $170-260^{\circ}C$ and 5-12.5 $kg/mm^2$ respectively. The experimental result are follows : The stress exponent value for creep was observed to about 7.3-6.43 and the activation energy for creep deformation was 44-41 kcal/mol. Larson-Miller parameter P for the crept specimens under the creep condition was obtained as P = (T + 460) (log $t_r$ + 8.6). Emperical equation for the creep rate was obtained by the computer simulation as follows. $${\varepsilon}\;=\;\exp[(-5.519{\times}10^{-4}{\sigma}+2.33{\times}10^{-2})T-6.98{\sigma}+18.295]{\times}{\sigma}^{-0.0142+10.18}\exp[\frac{(-6{\sigma}+47.8)1000}{RT}]$$ Fracture was dominated by intergranular mechanism over the experimental range.

  • PDF

세종문화회관 소극장 리모델링을 위한 음향설계 (Acoustical design for remodeling of the Little theatre in Sejong Performing Arts Center)

  • 전진용;이평직;서춘기
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.991-996
    • /
    • 2007
  • The Little theater in Sejong Performing Arts Center is a proscenium theater with 447 seats, which was built in 1978. The remodeling of the theater was decided in 2005 and acoustical design was conducted. Design guidelines were suggested based on the feasibility studies and acoustical measurement results. Target reverberation time was set at 1.2-1.6s with respect to the main performances. For the acoustical design, side balconies were added to increase the level of lateral reflections. Acoustic diffusers were designed and scattering coefficients were measured in a 1:10 reverberation chamber. From the results of computer simulation and a 1:10 scale model measurement, it was indicated that the new space will have RT of 1.2-1.6 s in middle frequencies when fully occupied.

  • PDF

공랭형 병렬방식 2중효용 흡수식 냉방시스템의 사이클 해석 (Cycle Analysis of Air-Cooled Double-Effect Absorption Cooling System with Parallel Flow Type)

  • 오명도;김선창;김영인;이홍원
    • 대한기계학회논문집
    • /
    • 제17권8호
    • /
    • pp.2099-2109
    • /
    • 1993
  • A gas-fired 4RT absorption heat pump was designed as an air-conditioner for domestic use during the summer. The absorption heat pump is air-cooled. double-effect, $LiBr-H_{2}O$ system with parallel flow type. The performance of the absorption heat pump in the cooling mode of operation was investigated through cycle modeling and simulation to obtain the system characteristics with parameter changes. System parameters considered in this analysis were the inlet temperature of cooling air to the absorber, the working solution concentrations, the ratio of the amount of the weak solution from the absorber, and the LTD's of each heat exchange component. The optimum designs and operating conditions were determined based on the operating constraints and the coefficient of performance.

현장성능시험에 의한 터보냉동기의 정상상태모델 개발 (Steady-state Modelling of Centrigugal Chiller through On-Site Test)

  • 장영수;신영기;백영진;김영일
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.83-88
    • /
    • 2001
  • This paper presents modelling and analyzing method of centrifugal chiller which has a rated capacity of 200 RT(703 kW) through on-site performance test. Field data of chiller installed in the clean-room building of KIST have been collected, Simple models were developed for predicting the heat exchangers and system performances by regression of chiller operation data during 5 days in August. The models proposed here account for the effect of variations of cooling capacity, temperatures and flow rates of secondary fluids. The models are consistent with real performance data from June to September within ${\pm}5%$ error. The COP of centrifugal chiller are estimated under the standard rating conditions and reduced mass flow rate of chilled and cooling water.

  • PDF

최적화 툴을 이용한 동특성 해석 모델 검증 (Validation of vehicle dynamic no del by using the optimization tool)

  • 박길배;성재호;우관제
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.1557-1565
    • /
    • 2009
  • According to the GM/RT2141, to assess the safety of vehicle, the validated the vehicle dynamic model should be applied. The validation of the vehicle model is against the static test, some kind of vehicle type test results have been used to determine the suspension characteristics and the vehicle dynamic characteristics. To validate the vehicle model and the test results, first the test results has been analysed as to specified the suspension characteristics and than the parameters to related with the test result has to be adjusted to show the same results of the test. In this process the parameters of vehicle model have been determined to show the coherence of the two results of the simulation and the test by trial & error. In this report, the optimization tool has been introduced in this model validation process and shows the efficient and well validated model.

  • PDF

소규모 주택에 대한 수평형 지열 히트펌프 형태 결정에 관한 연구 (A Study on the description of Horizontal Geothermal Heat pump Type on Small Residential House)

  • 윤장렬;조성우;최정민
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 추계학술발표대회 논문집
    • /
    • pp.328-332
    • /
    • 2011
  • The conclusion is derived from the arranged results and using a simulation by determining the shape of an optimum heat pump which is appropriate for small scale houses. It is concluded as 3 meters long for the laying depth of underground piping of the horizontal type geothermal heat pump system in regard to the 5 RT capacity standard that is suitable for a small scale house. The shape of the horizontal type geothermal heat pump system for a small scale house is theThree pipe shape whose trench length is short and pipe length laid in a trench is short. It is 9 for the number of laying pipes that is most appropriate to system.

  • PDF

U다목적 문화예술회관의 리모델링시 개선전후의 시뮬레이션 및 음향측정분석에 관한 연구 (A Study on the Properties of Acoustic in Multi-purpose Auditorium Using Remodeling and Computer Simulation)

  • 손장열;김정중;김용국
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.808-815
    • /
    • 2003
  • 최근에 이르기까지 문화예술회관들이 대중들의 문화적인 욕구에 의하여 많이 건립되었으나 대중들과 음악가와 연주자들을 도외시한 채 건축음향 기획 없이 건립되어진 많은 문화예술회관들이 지방자치시대를 맞이하여 지방재정에 적잖은 부담으로 작용하고 있으며 또한 민영화로 독자적으로 운영을 하지 않으면 안되게 되었다. 이와 같은 경쟁체제에서 많은 문화예술회관들이 음향문제로 많은 어려움을 겪고 있으나 대책은 미미한 실정이다. 본 연구는 U문화예술회관의 대공연장을 중심으로 대공연장의 음향특성을 측정분석하고 최근 6년간의 공연장의 장르별 이용률을 기초 자료로 활용하여 측정 결과를 중심으로 대공연장의 개선방향을 설정하고 음향 시뮬레이션를 통한 음향인자를 (잔향시간 (RT60, EDT), 명료도(C80, D50), LF, 음압레벨) 비교분석 평가하였다. 그리고 설계에 반영 벽체에 음향 보강 반사판을 시설하고 분석하여 리모델링 공사 후 음향특성이 개선됨을 확인할 수 있었으며 벽체에 시공된 반사판의 효능을 입증할 수 있었다.

  • PDF

HILS 적용을 위한 해상풍력 계통 연계 MMC 모델 개발 (Development of simulation model for offshore wind power generation with MMC for HILS application)

  • 신동철;윤진우;이동명
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 전력전자학술대회
    • /
    • pp.372-373
    • /
    • 2018
  • HVDC(High Voltage Direct Current)전력망은 발전소에서 생산한 교류를 직류로 변환한 이후 송전하여 부하에 가까운 전력변환기를 이용하여 교류로 변환한 후에 사용하는 방식이며, 전압형 HVDC에 MMC(Modular Multilevel Converter)가 널리 사용되고 있다. 본 논문에서는 MMC가 적용된 HVDC를 이용한 해상 풍력 계통 제어 성능을 테스트하기 위해 실시간 시뮬레이션 툴인 RT-Lab에 적용한 모델에 대해 설명하고자 한다.

  • PDF