• Title/Summary/Keyword: RS232c

Search Result 213, Processing Time 0.024 seconds

Implementation of RS232C Serial Communication by CSMA protocol (충돌검지 다중접속(CSMA) 프로토콜에 의한 RS232C 직렬통신의 구현)

  • Kwak, Hee-Soo;Han, Kyong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1998.07g
    • /
    • pp.2473-2475
    • /
    • 1998
  • In this paper, we implemented RS232C serial communication by the 2 wires(Data,GND), and multiple access, by the applying Collision Sensing Multiple Access(CSMA) Protocol. Multiple access is implemented by assigning a unique ID to each controller. The multiple access control operation starts by sending a command packet from a host to another host and the command packet is composed of ID bytes of source and target host computer, data bytes and the check sum, byte. In host computer, after sending command packet, the collision from loop back data. If collision is detected, it means a command packet was collided with another command packet for another host. The packet communication of the controller enables the multiple acces of the controller through the common serial data link. The application of this serial communication through CSMA protocol and the usage of two wires, have an effect on saving the wires and convenient of layout work.

  • PDF

Implementation of 16Kpbs ADPCM by DSK50 (DSK50을 이용한 16kbps ADPCM 구현)

  • Cho, Yun-Seok;Han, Kyong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.1295-1297
    • /
    • 1996
  • CCITT G.721, G.723 standard ADPCM algorithm is implemented by using TI's fixed point DSP start kit (DSK). ADPCM can be implemented on a various rates, such as 16K, 24K, 32K and 40K. The ADPCM is sample based compression technique and its complexity is not so high as the other speech compression techniques such as CELP, VSELP and GSM, etc. ADPCM is widely applicable to most of the low cost speech compression application and they are tapeless answering machine, simultaneous voice and fax modem, digital phone, etc. TMS320C50 DSP is a low cost fixed point DSP chip and C50 DSK system has an AIC (analog interface chip) which operates as a single chip A/D and D/A converter with 14 bit resolution, C50 DSP chip with on-chip memory of 10K and RS232C interface module. ADPCM C code is compiled by TI C50 C-compiler and implemented on the DSK on-chip memory. Speech signal input is converted into 14 bit linear PCM data and encoded into ADPCM data and the data is sent to PC through RS232C. The ADPCM data on PC is received by the DSK through RS232C and then decoded to generate the 14 bit linear PCM data and converted into the speech signal. The DSK system has audio in/out jack and we can input and out the speech signal.

  • PDF

Multiple Access Control of RS232C Serial Communications Interface

  • Kyongho Han;Park, Cheon-Won
    • Proceedings of the IEEK Conference
    • /
    • 2002.07a
    • /
    • pp.639-641
    • /
    • 2002
  • In this paper, we proposed the multiple access control of RS232C Serial Communications protocol using collision sense method. The communications wires of data transmission and reception are tied together through the buffer each to connect to the multiple communication channels. The hardware interface and control program are designed to build the prototype system and the experimental multiple access communications network is built by multiple PC systems and the transfer completion rate results are shown.

  • PDF

The Implementation research of CAN linked safety sensor hardware (CAN 연계형 안전진단센서 하드웨어 설계에 관한 연구)

  • Jeong, Soon-Ho;Kim, Seoung-Kwon;Cha, Jae-Sang
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.10 no.5
    • /
    • pp.209-213
    • /
    • 2010
  • This paper is a study of Car safety network system using sensed data from varied sensors. This hardware will work with various sensors and communication protocols. There are many sensors. Then, I selected 3 sensors for test, which were sonic sensor for distance checking, tilt sensor for rollover and impact sensor for car accident and theft. Also, there are many interfaces for sensor. Therefore I designed hardware to support various sensor interfaces. For instance ADC(Analog to Digital converter), I2C, RS232, RS485, CAN. In this case, sonic sensor have I2C interface, tilt sensor have RS485 interface and Impact sensor have analog interface. In this research, I can gather sensing data from 3 sensors (mentioned above), and sending control signal to other processor with RS232, RS485, CAN communication. So, we can use easily this hardware for many cases of systems, which need sensors.

Implementation of Remote Monitoring System Using Gateway for TCP/IP and RS-232 (TCP/IP와 RS-232의 게이트웨이를 이용한 원격 모니터링 시스템 구현)

  • Oh, Tae-Geun;Kim, Hyung-Bae;Nam, Boo-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.2231-2233
    • /
    • 2001
  • 현대사회에서 네트윅이 차지하는 비중은 점점 커져가고 있다. 따라서 네트윅을 활용할 수 있는 많은 노력들이 이루어지고 있다. 네트웍 프로토콜의 하나인 TCP/IP프로토콜을 이용한 LAN은 다른 정보를 처리하는 장치들을 연결하고, 자원을 공유하며, 고속의 통신을 가능하게하는 시스템이다. 본 논문은 TCP/IP 프로토콜과 장비와 장비 사이의 직렬 통신 방법인 RS232를 연계하는 게이트웨이를 통한 시스템 제어와 모니터링을 목적으로 하고자 한다. 제어 대상 시스템은 여러 가지의 적용이 가능하지만 본 논문을 위해 80C19SKC CPU로 제어되는 스텝 모터를 사용하였다.

  • PDF

Performance of Serial Communication Protocols through Conducting Threads (전도성사를 매체로 한 직렬 통신 프로토콜 성능)

  • Kim, Na-Young;Kim, Hwan;Kim, Juk-Young;Kwon, Young-Mi
    • Journal of Internet Computing and Services
    • /
    • v.12 no.5
    • /
    • pp.21-28
    • /
    • 2011
  • Recently medical and entertainment applications using conducting textile are suggested, but the data of conducting threads are not characterized, classified and verified. Only the data sheet published by manufacturing companies is available. Thus we need to verify the performances of the threading threads in communication. And we need a guideline if the existing communication protocols can be used for the conducting threads communication or the new specific communication protocols have to be developed for the communication. This paper classifies the characteristics of conducting threads made by domestic and overseas companies. Based on the criteria we classified conducting threads into three classes: class A, class B and class C. Further we carried out experiments to verify the adaptability of existing simple serial communication protocols such as RS232. Six different conducting threads are used in experiments and the length of each thread was 0.5m, 1m, 2m and 3m. The data transmission rate and error rate are collected and analyzed. RS485 is very prone to error due to static electricity from human and environment. So it may not be appropriate as long-distance communication protocol up to 12km which is possible in theory. RS232 shows stable and error-less data transmission ability even though every conducting thread didn’t show transmission capability over RS232. USB protocol shows high data rate transmission but the distance cannot be exceeded over 2m. Additionally, USB requires stable power supply. But if the power is supplied through conducting thread, its function is not.

The Ubiquitous-Dormitory Management System Based on RFID System (RFID 시스템을 이용한 U-기숙사 관리 시스템)

  • Oh, Jeong-Hoon;Eom, Ki-Hwan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.11
    • /
    • pp.2111-2118
    • /
    • 2008
  • This parer propose a U-dormitory management system based on 13.56MHz RFID system. The proposed U-dormitory management system consists of three parts, the RFID hardware system, the middleware, and the application. RFID hardware system uses 13.56MHz frequency which is suitable for a close range. The middleware is implemented to accept the RFID hardware system values using RS-232c communication method and forward the values to the application. The application is designed to make the DB using the forwarded Haloes, and works based on the DB. The efficacy of the Proposed U-dormitory management system is verified by means of experiments. In the experiments, we set up the system to the dormitory of Daeduk College to show the improvement results of proposed system.

Design and Implementation of an Intranet-based Message and File Transfer System using the INMARSAT-C (INMARSAT-C를 통한 인트라넷 기반의 메시지 및 파일 전송시스템 설계 및 구현)

  • 강병훈;임재홍;윤희철;배정철
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 1999.05a
    • /
    • pp.290-294
    • /
    • 1999
  • This paper describes the design and implementation of an intranet-based message and file transfer system using the INMARSAT-C for easy transmission and user-friendly interface. For these, onboard LAN including telex, printer and database with centralized one server is designed and constructed. Also, onboard computing environment which provides the INMARSAT-C terminal and RS-232C link interface built in with effective intranet-based web mail system between the ship and land.

  • PDF

Multi Channel Optical Source Controller Design Using $I^2$ C Bus Interface ($I^2$ C Bus interface를 이용한 다채널 광원 제어시스템 설계/구현)

  • 염진수;류광열;허창우
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2002.11a
    • /
    • pp.539-542
    • /
    • 2002
  • 본 논문에서 는 64채널 DWDM(Dense Wavelength Division Multiplexing)용 광원(Optical Source)을 구현하고, 이를 효율적으로 제어하기 위하여 I$^2$C Bus interface를 이용한 제어기를 설계하였다. 채널은 독립적으로 동작될 수 있도록 각각 Laser Diode 구동 회로와 마이크로프로세서, A/D 및 D/A 컨버터로 구성하였으며, 또한 각 채널들은 하나의 I$^2$C Bus를 통해 주 제어기와 연결된다 주 제어기는 RS-232 및 LAN을 통해 틀어오는 사용자의 명령을 I$^2$C Bus를 이용하여 각 채널에 전달하고, 채널로부터 들어오는 정보를 사용자에게 제공한다. RS-232C 및 LAN을 통한 PC와의 전송속도는 57600BPS로 구현하였다.

  • PDF

The Implementation of Communication Emulate Based on Component For Automation System (자동화시스템을 위한 컴포넌트 기반의 통신 Emulate 구현)

  • Jeong Hwa-Young
    • Journal of Digital Contents Society
    • /
    • v.3 no.2
    • /
    • pp.245-254
    • /
    • 2002
  • Currently, communication field for automation system can be divided by simple serial communication for communication between each internal devices and network base remote control system that is based on TCP/IP. In spite of great development of network, communication part for internal control is using simple RS232 base until present. Also, development techniques of system developed by object oriented program in modular programming techniques of each function unit. Currently, it developed by component base development technique that is parts unit of software. This is presented by the new alternative of software development techniques as techniques to composition independent operation unit including business logic and is connected to development of new system. Therefore, this research implemented internal communication Emulate in RS232C based on GUI that apply development techniques of component base. that is, I maked component to commnication control part between receiving and sending and, as composite it, Control part did to handling between send and receive data.

  • PDF