• Title/Summary/Keyword: RS-232c communication

Search Result 104, Processing Time 0.032 seconds

A Smart Sensor System with a Programmable Temperature Compensation Technique (프로그래머블한 온도 보상 기법의 스마트 센서 시스템)

  • Kim, Ju-Hwan;Kang, Yu-Ri;Lee, Woo-Kwan;Kim, Soo-Won
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.11
    • /
    • pp.63-70
    • /
    • 2008
  • In this paper, a smart sensor system for the MEMS pressure sensor was developed. A compensation algorithm and programmable calibration circuits were presented to eliminate errors caused by temperature drift of piezoresistive pressure sensors in itself. This system consisted of signal conditioning, calibration, temperature detection, microprocessor, and communication parts and these were integrated into a SOC. A RS-232 interface was employed for monitoring and control of a smart sensor system. The area of fabricated IC is $4.38{\times}3.78\;mm^2$ and a $0.35{\mu}m$ high voltage CMOS process was used. Compensation error for temperature drift of 50 KPa pressure sensors was measured into ${\pm}0.48%$ in the range of $-40^{\circ}C{\sim}150^{\circ}C$. Total power consumption was 30.5 mW.

Asan Medical Center Laboratory Information System (R) Information Communication System for Routine Hematology Using a Down-Sized Computer - (서울중앙병원 임상병리과 정보관리시스템(III))

  • 민원기;최윤미
    • Journal of Biomedical Engineering Research
    • /
    • v.15 no.3
    • /
    • pp.333-340
    • /
    • 1994
  • Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16 MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with two complete blood count analyzers (Sysmex WE-8000 and Coulter STKS) for unidirectional data transmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology.

  • PDF

Design and Implementation of Mobile Phone Interface Module for DGPS Correction Message Transmission (DGPS 보정신호 전송을 위한 휴대전화 인터페이스 모듈의 설계 및 구현)

  • Yi, Jae-hoon;Kim, Chang-Soo;Jeong, Seong-Hoon;Lee, Tae-Oh;Yun, Hee-Chul;Yim, Jae-Hong
    • Journal of Navigation and Port Research
    • /
    • v.26 no.4
    • /
    • pp.419-426
    • /
    • 2002
  • The conventional RTK-GPS technique has many problems which are permission using RF wireless modem, influence of geographic obstacle using radio wave, frequency interference, finiteness of frequency resources. To solve these problems, in this paper, we designed the DGPS correction message transmission system as a method to substitute the RF wireless modem of RTK-DGPS receiver. Then the interface module was designed and implemented for linkage of GPS receiver and mobile phone. As a result worked differential surveying using receiving correction message using RS-232C and communication control, users of mobile station were worked differential surveying correction between mobile phones. Interface module system was received the same result of precision which was compared RF wireless modem system.

Development of Underground Displacement and Convergence Auto-Measuring Program for the Tunnel Using the Fiber Optic Sensor (광섬유 센서를 이용한 터널 지중 및 내공변위 자동계측 프로그램 개발)

  • Choi, Myong-Ho;Yoon, Ji-Son;Kwon, Oh-Duk;Kwon, Oh-Jun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.1361-1368
    • /
    • 2005
  • In this paper, the theoretical method of measuring the tunnel convergence and underground displacement, the objective indices of assessing safety for tunnel construction, using the fiber optic sensor is studied by developing the program to automatically measure them. The model test of Con'c beam is conducted to evaluate reliability of the fiber optic sensor. Furthermore, using the RS232 communication protocol as well as Visual C# and Visual C++, the programming tools, the program was developed to detect automatically the measured value of the fiber optic sensor, calculate the tunnel convergence and underground displacement, predict the deformed shape of the tunnel, and evaluate loosening zone due to the tunnel excavation.

  • PDF

Remote Measurement of ECU Self-Diagnostic Signal based on the Windows CE

  • Lee, Seong-Cheol;Yun, Yeo-Hung;Se, Ji-Won;Kwon, Tae-Kyu;Lee, Young-Chun;Jang, Bong-Choon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.68.2-68
    • /
    • 2002
  • The purpose of this paper is to monitor ECU's self-diagnostic signal without wire. In order to measure the ECU's self-diagnostic signal, the interfaced circuit is developed to communicate ECU with a designed display terminal according to the ISO, SAE regulation of communication protocol standard. An 80C196KC processor is used for communicating ECU's self-diagnostic signal and communication data are sent to PDA monitoring system that is based on the Windows CE. Software on PDA is developed to monitor the ECU's self-diagnostic signal in which RS232 port is programmed by half duplex method. The algorithms for measuring the ECU's self-diagnostic signals are verified to mo...

  • PDF

Development of Sorting Machine for Photo Diode and Improvement of Sorting Precision by using Machine Vision (광 다이오드 분류장치 및 비젼을 이용한 정밀도 향상)

  • Ryuh B.S.;Park S.M.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.153-154
    • /
    • 2006
  • Development of sorting machine for photo diode and its control system is addressed. The sorting machine for optical communication device requires high positional precision because the alignment is one of the most important point in the sorting process. This sorting method describes how to detect the target chip's angle and position from the wafer. The machine vision system is used for the feedback control. This sorting machine is implemented by motion controller, machine vision and various solenoid valve and is interfaced with RS-232c, GPIB and PCI communication. This system gets the position accuracy within $1{\mu}m$ with our experiments.

  • PDF

A Study of Central Data Acquiring by Using Computer Serial Port and Parallel Port (직.병렬 PORT를 이용한 중앙직접 신호취득방식에 관한 연구)

  • Park, Ho-Cheul;Yoon, Woo-Yung;Chun, Young-Sik
    • Proceedings of the KIEE Conference
    • /
    • 1998.07b
    • /
    • pp.663-665
    • /
    • 1998
  • The measuring data acquisition methods from local sensor are many kinds of techniques. But, if sampling time is not important and we need data of many sensors it is more resonable to be applied economical system. In this paper, the data acquisition technique is used two RS232C communication signals simultaneously. The one come from computer serial port, and another is signal changed from parallel port. In this case the circuits would be simplification and that communication cable is connected by Parallel instead of Branch connection.

  • PDF

Development of Digital Heat Pump App to Monitor Temperature and Humidity using Smartphone (스마트폰을 이용하여 온습도를 모니터링하는 디지털 열펌기 앱 개발)

  • Son, Nam-Rye;Jo, Won-Hee;Moon, Gun-Mo;Lee, Esther
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2018.05a
    • /
    • pp.573-574
    • /
    • 2018
  • 현재 시중에서 판매되고 있는 디지털 열펌기를 IT시대에 맞게 스마트 열펌기로 진화시키고자 스마트폰으로 온습도를 모니터링하고자 제안한다. 스마트폰으로 온습도를 모니터링할 때 디지털 열펌기와 스마트폰 간 RS-232C 통신을 하여 데이터를 전송한다. 미용사는 디지털 열펌기에 가까이에 있지 않아도 고객의 파마 상황을 실시간으로 모니터링이 가능하여 고객 및 미용사입장에서 편의성이 확대될 수 있다.

  • PDF

Shop-Floor Information Management for u-Manufacturing (u-Manufacturing 생산현장 정보취합 및 관리 방안)

  • Kim D.H.;Song J.Y.;Lee S.W.;Cha S.K.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.942-945
    • /
    • 2005
  • This paper tried to analyze the collection and management method of shop-floor information for development of digital framework in u-manufacturing. In detail, the shop-floor information collection method through the direct communication with manufacturing devices using network Including RS-232C/422, field bus and ethernet is analyzed and proposed. In case the direct communication is impossible, the information collection method through additional sensors or data acquisition units is analyzed and proposed. Moreover, the collection method through bar code reader or touch screen of operators is analyzed and proposed to act up to machine to man/mobile/machine.

  • PDF

DNP3.0 Traffic Monitoring System (DNP3.0 트래픽 모니터링 시스템)

  • Song, Byung-Kwon;Kim, Sei-Byuck;Jeong, Tae-Eui;Kim, Kun-Woong
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2008.05a
    • /
    • pp.845-848
    • /
    • 2008
  • DNP3.0(Distributed Network Protocol 3.0) 프로토콜은 자동화 처리 시스템 사이에서 Master와 Slave의 개념을 적용한 프로토콜로써 현재 한전 SCADA 시스템의 표준 프로토콜로 선정되어 원방 감시 제어용으로 사용되고 있다. 이 DNP3.0 데이터를 RS-232C를 이용해서 전송 할 때, 각각의 DNP3.0 Layer인 DataLink Layer, Transport Layer 그리고 Application Layer의 분석 모듈을 설계하고 구현하였다.