• Title/Summary/Keyword: RRA

Search Result 46, Processing Time 0.027 seconds

Data Reusable Search Scan Methods for Low Power motion Estimation (저전력 움직임 추정을 위한 데이터 재사용 스캔 방법)

  • Kim, Tae Sun;SunWoo, Myung Hoon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.9
    • /
    • pp.85-91
    • /
    • 2013
  • This paper proposes the data reusable search scan methods for full search and fast search to implement low power Motion Estimation (ME). The proposed Optimized Sub-region Partitioning (OSP) method which divide search region into several sub-region can reduce the number of the required Reconfigurable Register Array (RRA) by half compared to the existing smart snake scan method for the same data reusability. In addition, the proposed Center Biased Search Scan method (CBSS) for various fast search algorithms can improve the data reusability. The performance comparisons show that the proposed search scan methods can reduce the average redundant data loading about 26.9% and 16.1% compared with the existing rater scan and snake scan methods, respectively. Due to the reduction of memory accesses, the proposed search scan methods are quite suitable for low power and high performance ME implementation.

Analysis on the Induction Effects by Separation Distance between the Power Feeding Station and the Telecommunication Cables (3점 전위강하법과 2극 측정법에 대한 접지저항 측정 결과 분석)

  • Choi, Mun-hwan;Lee, Snag-mu;Cho, Pyung-dong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.10a
    • /
    • pp.577-580
    • /
    • 2012
  • RRA Notification No.2010-36 suggests the 3-point method(fall-of-Potential) using 2 auxiliary poles only as a test method of earth resistance. However this method needs to much space to install auxiliary poles so it is very difficult to measure the earth resistance in spots such as a mountain district, rocky district. So, we have analyzed the methods of 2-point method and loop resistance method in IEEE std. 81 and ITU-handbook(Earthing and Bonding) and applied these methods in test bed with 3-point method. In this paper we have compared and analyzed the earth resistance value using these 3 methods.

  • PDF

Effects of Skater and Sprinter Combined Pattern in PNF on Muscle Contraction Onset Time and Muscle Activation of Trunk Muscle (고유수용성신경근촉진법의 스케이터와 스프린터 통합패턴이 몸통근육의 근활성도와 근수축 개시에 미치는 영향)

  • Kim, Yoonhwan;Lee, Hyoungsoo
    • Archives of Orthopedic and Sports Physical Therapy
    • /
    • v.14 no.2
    • /
    • pp.55-64
    • /
    • 2018
  • Purpose : The purpose of this study was to investigate the effect of the sprinter and skater combined patterns on muscle contraction onset time and muscle activation of body stabilizing muscles. Method : Our study included young and healthy men in their 20s. The participants used the sprinter and skater combined patterns of the proprioceptive neuromuscular facilitation (PNF) methods to measure muscle activation and muscle contraction onset time of the trunk muscles. To measure muscle contraction onset time and muscle activation, electrodes were attached to the rectus abdominis (RA), external oblique (EO), internal oblique (IO), and erector spinalis (ES) regions. Significant differences were identified using a paired t-test and a one-way analysis of variance (ANOVA) analysis. Result : In the sprinter combined pattern, the muscle with the fastest onset time of contraction was the RES, and that with the slowest was the RRA (p<.001). In the skater combined pattern, the muscle with the fastest onset time of contraction was the LES, and that with the slowest was the LRA (p<.001). In the sprinter combined pattern, the REO and LIO presented medium muscle contraction onset times (p<.001). In the skater combined pattern, the LEO and RIO presented medium muscle contraction onset times (p<.001). Conclusions: Based on these results, these patterns could be used as exercise methods for the elderly with delayed proactive response speeds of the body stabilization methods due to imbalances in body stabilizing muscles or limbs movement.

High-velocity ballistics of twisted bilayer graphene under stochastic disorder

  • Gupta, K.K.;Mukhopadhyay, T.;Roy, L.;Dey, S.
    • Advances in nano research
    • /
    • v.12 no.5
    • /
    • pp.529-547
    • /
    • 2022
  • Graphene is one of the strongest, stiffest, and lightest nanoscale materials known to date, making it a potentially viable and attractive candidate for developing lightweight structural composites to prevent high-velocity ballistic impact, as commonly encountered in defense and space sectors. In-plane twist in bilayer graphene has recently revealed unprecedented electronic properties like superconductivity, which has now started attracting the attention for other multi-physical properties of such twisted structures. For example, the latest studies show that twisting can enhance the strength and stiffness of graphene by many folds, which in turn creates a strong rationale for their prospective exploitation in high-velocity impact. The present article investigates the ballistic performance of twisted bilayer graphene (tBLG) nanostructures. We have employed molecular dynamics (MD) simulations, augmented further by coupling gaussian process-based machine learning, for the nanoscale characterization of various tBLG structures with varying relative rotation angle (RRA). Spherical diamond impactors (with a diameter of 25Å) are enforced with high initial velocity (Vi) in the range of 1 km/s to 6.5 km/s to observe the ballistic performance of tBLG nanostructures. The specific penetration energy (Ep*) of the impacted nanostructures and residual velocity (Vr) of the impactor are considered as the quantities of interest, wherein the effect of stochastic system parameters is computationally captured based on an efficient Gaussian process regression (GPR) based Monte Carlo simulation approach. A data-driven sensitivity analysis is carried out to quantify the relative importance of different critical system parameters. As an integral part of this study, we have deterministically investigated the resonant behaviour of graphene nanostructures, wherein the high-velocity impact is used as the initial actuation mechanism. The comprehensive dynamic investigation of bilayer graphene under the ballistic impact, as presented in this paper including the effect of twisting and random disorder for their prospective exploitation, would lead to the development of improved impact-resistant lightweight materials.

Ultrasensitive serum thyroglobulin the usefulness of evaluation (Ultrasensitive serum thyroglobulin의 유용성 평가)

  • Lee, Sun Ho;Cho, Eun Bit;Shin, Young Kyun;Lee, Young Ji;Yoo, Seun Hee;Kim, Nyun Ok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.102-107
    • /
    • 2015
  • Purpose Serum Thyroglobulin measurement is a major tool for the follow-up of differentiated thyroid cancer (DTC) patients. Thyroglobulin is Normal thyroid tissue, or thyroid cancer tissue produced only. Thyroid hormone to a halt without Tg differentiation of thyroid cancer recurrence just by measuring how to decide whether there was increasing expectations if I can do it instead. Therefore, in excellent sensitivity Tg new inspection of the functional sensitivity by measuring the looked to evaluate the usefulness of reagents. Thyroidectomy is measuring the numbers Tg (total thyroidectomy) remaining thyroid ablation and radioactive iodine (radioactive iodine remnant ablation, RRA) DTC in patients being diagnosed with or help predict the remaining early detection of thyroid cancer recurrence. Materials and Methods Agent that I'm currently using Tg of the measurements of low clinical specimen for a second drainage of the three (0.08 0.17, 0.98, ng/mL) within the scope of the dilute magnification (2, 4, 8, 16, 32 times) by dilute Intraassy (n=10) and Interassay (n=10) out in no time. Concentration value according to the coefficient of variation and the mean and standard deviation of each measurement (Coefficient of variation, CV) the absolute value of the measured values that corresponds to 20 percent target a coefficient of variation of CV Find the value of the concentration of the functional sensitivity measurement did. Also, analytical sensitivity with recovery rates, Dilution test inspections, and interrelationship, compared. Results Sensitivity is an excellent analytical sensitivity within the prosecutor kit Tg 0.006 ng/mL, and core analytical sensitivity, conducted by the 0.006 ng/mL to same conclusion. Be rather high to 142 percent recovery rate was 60 to measurement and functional sensitivity, 0.01766 ng/mL(Intraassay n=10) was measured at. CBC is relatively good correlation as ($R^2=0.949$) the correlation. Conclusion Recently ultrasensitive thyroglobulin this clinically important indicators of the previous kit and demands are lower than sensitivity to the measurement results. Therefore, ultrasensitive thyroglobulin test is correlated that there would be useful in value in nuclear medicine the thyroid gland.

  • PDF

Clinical Usefulness of Thyrotropin Binding Inhibitor Immunoglobulin (TBII) Assay by the Comparative Method (측정법에 따른 갑상선자극호르몬 결합억제면역글로블린(TBII)의 임상적 유용성 검토)

  • Park, Hee-Won;Shin, Hee-Jung;Kim, Tae-Hoon;Noh, Gyeong-Woon;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.175-180
    • /
    • 2009
  • Purpose: Detection of TSH-binding inhibitor immunoglobulin (TBII) in patients with hyperthyroidism is an important result of Graves' disease (GD) and hyperthyroidism treatment. This has been made out an inspection by commercial radio-receptor assays. To increase the sensitivity and the specificity of the assay, many results of the assay were reported. In this study we evaluated the clinical usetulness of TBII assays by the Comparative method. Material and Methods: We were measured by using healthy control group (n=30, male=20, female=10) of Seoul National University Hospital Healthcare System Gangnam Center from January to March in 2009. Similarly, We were measured by using hyperthyroid (TSH<$0.05\;{\mu}IU/mL$, FT4>1.80 ng/dL) experimental group (n=58, male=14, female=44) of division of endocrinology and metabolism department of internal medicine Seoul National University Hospital from January to March in 2009. We made a comparative study of each two assays from the first generation to the third generation. We were used of TSAb assay as a measurement of GD diagnostic technique. Results: The specificity of healthy control group was 100% according to the generation. (Specificity=100%, n=30) The sensitivity of hyperthyroid experimental group were the first generation RSR<%> (79.3%, n=58), RSR (51.7%, n=58), the second generation RSR-CT (93.1%, n=58), BRAHMSCT (98.3%, n=58), the third generation ELISA (94.6%, n=56), ECLIA (97.7%, n=58) and TS-Ab<%> (93.5%, n=46). Conclusion: We were used of TSAb assay as a measurement of GD diagnostic technique, The result of data showed a high correlation between the third generation TBII assay and the second generation TBII assay ($R^2$=0.923). Instead of the first generation assay, the second generation assay can be more useful in clincal diagnosis.

  • PDF