• Title/Summary/Keyword: ROIs

Search Result 168, Processing Time 0.025 seconds

Evaluation of Focal Bone Mineral Density Using Three-dimensional Measurement of Hounsfield Units in the Proximal Humerus

  • Moon, Young Lae;Jung, Sung;Park, Sang Ha;Choi, Gwi Youn
    • Clinics in Shoulder and Elbow
    • /
    • v.18 no.2
    • /
    • pp.86-90
    • /
    • 2015
  • Background: Although there are several methods for evaluating bone quality, Hounsfield units (HU), a standardized computed tomography (CT) attenuation coefficient, provide a useful tool for estimating focal bone mineral density (BMD). The aim of this study is to investigate the HU for evaluating the degree of osteoporosis in greater tuberosity with regard to anchor positioning. Methods: Forty patients diagnosed as normal on shoulder CT were included and categorized according to age and gender. Axially sectioned CT images were processed to 3-dimensional models containing information about bone quality using Mimics (14.11 platform v14.1.1.1 Materialise). Three-dimensional anchors were simulated and positioned according to 6 regions of interest (ROI) in the greater tuberosity classified using Tingart's system. Mean HU of intra-anchor volumes in the 6 regions was measured. Results: A significant decrease in HU was observed with increasing age (p=0.0001) and menopause (p<0.001). A significant difference in HU was found between male and female groups with males showing the higher values (p=0.0001). HU of proximal areas of ROI was higher than those of distal areas (p<0.005). However, although mean HU of distal posterior ROI showed the lowest values, no statistically significant difference was found between anterior, middle, and posterior regions (p=0.087). Conclusions: Mean HU of ROIs provides a tool for preoperative assessment of focal BMD, which is a factor of suture anchor stability and can be used to aid decision-making regarding secure anchor positioning for rotator cuff repair. Our data support that the most secure point is the proximal regions of ROI.

A Comparison of Iopamidol with Iopromide and Iohexol Contrast Media in Hepatic CT Angiography in Beagle Dogs (비글견의 간 CT 혈관조영상에서의 Iopamidol과 Iopromide, Iohexol 조명제의 비교실험)

  • Jeong Yu-Cheol;Lim Chang-Yun;Kim Gyeong-Min;Lee Sung-Ok;Jung Joo-Hyun;Chang Jin-Hwa;Oh Sun-Kyoung;Song Kyoung-Jin;Yoon Jung-Hee;Choi Min-Cheol
    • Journal of Veterinary Clinics
    • /
    • v.23 no.2
    • /
    • pp.129-132
    • /
    • 2006
  • The purpose of this paper was to compare the clinical efficacy of iopamidol and iopromide, iohexol nonionic contrast media in terms of their image quality in Beagle dogs with hepatic CT angiography and their application in veterinary clinics. With 9 Beagle dogs, contrast media of iopamidol (pamiray-$300^(R)$) and iopromide (ultravist-$300^(R)$, iohexol (omnipaque-$300^(R)$) were induced intravenously (600 mg I/kg, BW) and CT angiography was done under general anesthesia. CT scan included scout, pre-contrast and cine examinations. During CT angiography, peak HU (Hounsfield unit) and peak time were examined on each site (ROI; region of interest) of the aorta, caudal vena cava, potral vein and liver parenchyma. Any side effects were also examined. After experiments, it was found that there were no significant changes of HU and maximal enhancing time of each ROIs of aorta, caudal vena cava, portal vein and liver parenchyma between these contrast media. And any side effects were not noted. So it is concluded that iopamidol has similiar contrast enhancement like as iopromide and iohexol in hepatic angiography and and it is thought to be useful for evaluation of the abdominal organs by CT scan in veterinary clinics.

Effects of Zusanli (ST36) Acupuncture on Abdominal Thermography of Health Subject (족삼리(足三里) (ST36) 자침(刺鍼)이 복부(腹部) 한열변화(寒熱變化)에 미치는 영향(影響))

  • Sim Won-Bo;Kim Jae-Hyo;Kim Jong-Sung;Song Jae-Soo;Kim Kyung-Sik;Sohn In-Cheul
    • Korean Journal of Acupuncture
    • /
    • v.20 no.1
    • /
    • pp.1-20
    • /
    • 2003
  • This study was examined for effects of acupuncture of Zusanli (ST36) on the abdominal thermography of health subject. The volunteers who participating in this study had taken rest for 20-30 mins in room temperature (23-$25^{\circ}C$) before the examination and informed them what to prohibit smoking, drinking and administration of drug for the previous day. The thermography of abdomen including a below part of the chest was taken using Infra-Red Imaging System (IR 2000, MEDI-CORE Co, Korea) by time interval of 15 minutes at 15 min before, just before and 15 min after, 30 min after and 45 min after acupuncture stimulation. Acupuncture was applied to the left ST36 acupoint for 30 mins. The results showed that acupuncture of ST36 significantly had more potencies of changes on all the of abdominal thermography than those of control group. Also, it was observed that the quantities of thermal changes following acupuncture of ST36 been increased significantly comparing that of control group at all the ROIs (region of interest). Observed the thermography classified by ROI, however, it was failed that acupuncture of ST36 could modulate the specific areas concerning to the abdominal pathway of Stomach Meridian. These results suggest that acupuncture of ST36 may modulate thermal distributions and changes of abdominal areas including the below of chest.

  • PDF

Usefulness of fractal analysis for the diagnosis of periodontitis (치주질환 진단시 프랙탈 분석의 유용성에 관한 연구)

  • Cha Sang-Yun;Han Won-Jeong;Kim Eun-Kyung
    • Imaging Science in Dentistry
    • /
    • v.31 no.1
    • /
    • pp.35-42
    • /
    • 2001
  • Purpose: To evaluate the usefulness of fractal analysis for diagnosis of periodontitis. Materials and Methods : Each 30 cases of periapical films of male mandibular molar were selected in normal group and patient group which had complete furcation involvement. They were digitized at 300 dpi, 256 gray levels and saved with gif format. Rectangular ROIs (10×20 pixel) were selected at furcation, interdental crest, and interdental middle 1/3 area. Fractal dimensions were calculated three times at each area by mass radius method and were determined using a mean of three measurements. We compared fractal dimensions at furcation and interdental crest area of normal group with those of patient group. And then we compared ratio of fractal dimensions at furcation area, interdental crest area to interdental middle 1/3 area. Results: Fractal dimension at interdental crest area of normal group was 1.979±0.018 and that of patient group 1.971±0.012 (p>0.05). Fractal dimension at furcation area of normal group was 1.986±0.024 and that of patient group 1.974±0.015 (p<0.05). The ratio of fractal dimension at interdental crest area to interdental middle 1/3 of normal group was 1.003±0.015 and that of patient group 0.993±0.018 (p<0.05). The ratio of fractal dimension at furcation area to interdental middle 1/3 of normal group was 1.006±0.018 and that of patient group 0.994±0.018 (p<0.05). Conclusion : The ratio of fractal dimension at interdental crest and furcation area to interdental middle 1/3 area showed a statistically significant difference between normal and patient group. In conclusion, it is thought that fractal analysis might be useful for the diagnosis of periodontitis.

  • PDF

Design of a Real-time Algorithm Using Block-DCT for the Recognition of Speed Limit Signs (Block-DCT를 이용한 속도 제한 표지판 실시간 인식 알고리듬의 설계)

  • Han, Seung-Wha;Cho, Han-Min;Kim, Kwang-Soo;Hwang, Sun-Young
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.12B
    • /
    • pp.1574-1585
    • /
    • 2011
  • This paper proposes a real-time algorithm for speed limit sign recognition for advanced safety vehicle system. The proposed algorithm uses Block-DCT in extracting features from a given ROI(Region Of Interest) instead of using entire pixel values as in previous works. The proposed algorithm chooses parts of the DCT coefficients according to the proposed discriminant factor, uses correlation coefficients and variances among ROIs from training samples to reduce amount of arithmetic operations without performance degradation in classification process. The algorithm recognizes the speed limit signs using the information obtained during training process by calculating LDA and Mahalanobis Distance. To increase the hit rate of recognition, it uses accumulated classification results computed for a sequence of frames. Experimental results show that the hit rate of recognition for sequential frames reaches up to 100 %. When compared with previous works, numbers of multiply and add operations are reduced by 69.3 % and 67.9 %, respectively. Start after striking space key 2 times.

Optimization of PET Scan Time Using Phantom Studies (팬텀 영상을 이용한 PET 스캔시간의 최적화 연구)

  • 정하규;김동현;정해조;손혜경;홍순일;윤미진;이종두;김희중
    • Progress in Medical Physics
    • /
    • v.13 no.3
    • /
    • pp.139-148
    • /
    • 2002
  • The measured attenuation correction with transmission (Tx) scans produced quantitatively accurate images. However, it was not clear for optimal emission (Ex) and Tx scan time in PET imaging. This study was to evaluate acceptable Ex and Tx scan time by simulating clinical situations using various phantoms. Cylindrical and NEMA phantom were used for $^{18}$ F-PET scan using 2D protocol in GE Advance PETTM scanner. Cylindrical phantom was filled with 136 MBq 18F, and five regions of interests (ROI) were drawn on 23 slices. NEMA phantom had three inserts containing water, air and polytetrafluoro-ethylene (PTFE). Outside of these inserts were filled with 309 MBq of $^{18}$ F, and total 12 ROIs were drawn on 23 slices. Scans were carried out according to five Ex scan times: 2, 5, 10, 15, and 30 min, and nine Tx scan times: 2, 3, 4, 5, 7, 10, 15, 20, and 30 min. Images were reconstructed using measured attenuation correction, and ROI analyses were performed for all images, and mean, standard deviation (SD), coefficient of variation and percent errors were calculated. For cylindrical phantom study, ROI mean and SD were decreased as Ex and Tx time increased. Coefficients of variation were kept constant, when Tx was greater than 10 min. The amount of error decreased for the increment of Ex time from 10 min to 15 min was almost the same to that from 15 min to 30 min. In NEMA phantom Tx 15 min showed the lowest er개r level when the percent errors for three inserts were summed for all of the Ex times. This study suggested that Ex 15 min and Tx 15 min were acceptable as optimal scan time for the scanning protocol and the dose of radiopharmaceuticals used in these phantom study.

  • PDF

Strain elastography of tongue carcinoma using intraoral ultrasonography: A preliminary study to characterize normal tissues and lesions

  • Ogura, Ichiro;Sasaki, Yoshihiko;Sue, Mikiko;Oda, Takaaki
    • Imaging Science in Dentistry
    • /
    • v.48 no.1
    • /
    • pp.45-49
    • /
    • 2018
  • Purpose: The aim of this study was to evaluate the quantitative strain elastography of tongue carcinoma using intraoral ultrasonography. Materials and Methods: Two patients with squamous cell carcinoma (SCC) who underwent quantitative strain elastography for the diagnosis of tongue lesions using intraoral ultrasonography were included in this prospective study. Strain elastography was performed using a linear 14 MHz transducer (Aplio 300; Canon Medical Systems, Otawara, Japan). Manual light compression and decompression of the tongue by the transducer was performed to achieve optimal and consistent color coding. The variation in tissue strain over time caused by the compression exerted using the probe was displayed as a strain graph. The integrated strain elastography software allowed the operator to place circular regions of interest (ROIs) of various diameters within the elastography window, and automatically displayed quantitative strain (%) for each ROI. Quantitative indices of the strain (%) were measured for normal tissues and lesions in the tongue. Results: The average strain of normal tissue and tongue SCC in a 50-year-old man was 1.468% and 0.000%, respectively. The average strain of normal tissue and tongue SCC in a 59-year-old man was 1.007% and 0.000%, respectively. Conclusion: We investigated the quantitative strain elastography of tongue carcinoma using intraoral ultrasonography. Strain elastography using intraoral ultrasonography is a promising technique for characterizing and differentiating normal tissues and SCC in the tongue.

3D Visualization of Brain MR Images by Applying Image Interpolation Using Proportional Relationship of MBRs (MBR의 비례 관계를 이용한 영상 보간이 적용된 뇌 MR 영상의 3차원 가시화)

  • Song, Mi-Young;Cho, Hyung-Je
    • The KIPS Transactions:PartB
    • /
    • v.10B no.3
    • /
    • pp.339-346
    • /
    • 2003
  • In this paper, we propose a new method in which interpolation images are created by using a small number of axiai T2-weighted images instead of using many sectional images for 3D visualization of brain MR images. For image Interpolation, an important part of this process, we first segment a region of interest (ROI) that we wish to apply 3D reconstruction and extract the boundaries of segmented ROIs and MBR information. After the image size of interpolation layer is determined according to the changing rate of MBR size between top slice and bottom slice of segmented ROI, we find the corresponding pixels in segmented ROI images. Then we calculate a pixel's intensity of interpolation image by assigning to each pixel intensity weights detected by cube interpolation method. Finally, 3D reconstruction is accomplished by exploiting feature points and 3D voxels in the created interpolation images.

Secured Telemedicine Using Whole Image as Watermark with Tamper Localization and Recovery Capabilities

  • Badshah, Gran;Liew, Siau-Chuin;Zain, Jasni Mohamad;Ali, Mushtaq
    • Journal of Information Processing Systems
    • /
    • v.11 no.4
    • /
    • pp.601-615
    • /
    • 2015
  • Region of interest (ROI) is the most informative part of a medical image and mostly has been used as a major part of watermark. Various shapes ROIs selection have been reported in region-based watermarking techniques. In region-based watermarking schemes an image region of non-interest (RONI) is the second important part of the image and is used mostly for watermark encapsulation. In online healthcare systems the ROI wrong selection by missing some important portions of the image to be part of ROI can create problem at the destination. This paper discusses the complete medical image availability in original at destination using the whole image as a watermark for authentication, tamper localization and lossless recovery (WITALLOR). The WITALLOR watermarking scheme ensures the complete image security without of ROI selection at the source point as compared to the other region-based watermarking techniques. The complete image is compressed using the Lempel-Ziv-Welch (LZW) lossless compression technique to get the watermark in reduced number of bits. Bits reduction occurs to a number that can be completely encapsulated into image. The watermark is randomly encapsulated at the least significant bits (LSBs) of the image without caring of the ROI and RONI to keep the image perceptual degradation negligible. After communication, the watermark is retrieved, decompressed and used for authentication of the whole image, tamper detection, localization and lossless recovery. WITALLOR scheme is capable of any number of tampers detection and recovery at any part of the image. The complete authentic image gives the opportunity to conduct an image based analysis of medical problem without restriction to a fixed ROI.

CT Densitometry of Normal Tissue and Mass of Lung according to Reconstruction Algorithm (재구성 연산 방식에 따른 흉부의 정상 조직과 종괴의 CT 밀도 측정)

  • Yoon, Han-Sik
    • Journal of radiological science and technology
    • /
    • v.25 no.2
    • /
    • pp.39-45
    • /
    • 2002
  • Fifty patients with lung mass were studied to evaluate the effect of reconstruction algorithm on the CT number of lung mass and normal thoracic tissues. In each examination, the CT image of the lung mass was reconstructed using soft, standard, detail and bone algorithm. The results were shown as follows 1. the average maximum difference of lung mass density on the ROIs using 4 different algorithms was less than 1HU. 2. The maximum difference in the degree of lung mass enhancement was respectively $0.1{\sim}3.2HU$ (ROI $0.5\;cm^2$), $0.1{\sim}2.8HU$(ROI $3\;cm^2$) and $0.0{\sim}2.1$(ROI $6\;cm^2$). 3. The mean density of the normal thoracic tissues was highest in the bone algorithm, though there was no significant between 4 different reconstruction algorithms(p = 1.00).

  • PDF