• Title/Summary/Keyword: RMS signal

Search Result 304, Processing Time 0.025 seconds

Effect of Applied Pressure Differences to Abdomen on Lumbar and Abdominal Muscle Activation During Upper Limb Exercise (상지운동 동안 복부에 적용된 압력 차이가 요부와 복부 근육 활성도에 미치는 영향)

  • Ko, Eun-Hye;Yoon, Hye-Sun;Cynn, Heon-Seock;Lee, Kang-Sung
    • Journal of Korean Physical Therapy Science
    • /
    • v.10 no.2
    • /
    • pp.96-103
    • /
    • 2003
  • The purpose of this study was to assess the effect of applied pressure to abdomen on lumbar and abdominal muscle activation during upper limb exercise. The experimental group consisted of twenty-seven healthy male subjects (mean age=$22.40{\pm}2.19years$, mean height=$175.30{\pm}2.19cm$, mean weight= $67.67{\pm}7.44kg$, RM=$8.43{\pm}2.76kg$). In each different pressure condition (OmmHg, 30mmHg, 70mmHg, 100mmHg), upper limb exercise was performed in total of 10 trials with 10 RM dumb-bell exercise. Lumbar and abdominal muscle activity was measured using surface bipolar electrode electromyography(EMG). EMG activity was measured from upper rectus abdominis, external oblique abdominis, internal oblique abdominis, and elector spinae. The raw EMG signal was processed into the root mean square(RMS). All RMS EMG data were normalized and express as a percentage of the EMG(%EMG). Collected data were statistically analyzed by SPSS/PC Ver 10.0 using two-way analysis of variance for repeated measures($4{\pm}3$) and Bonferroni post hoc, test. Lumbar and abdominal muscle activation was significantly increased when 100 mmHg was applied(p<.05). Upper rectus abdominis activation was significantly increased compared as other muscles activation(p<.05). However, there were no interaction between pressure and muscles(p>.05). The findings of this study can be used as a fundamental data when lumbar orthosis is applied and external pressure can be used as a therapeutic tool.

  • PDF

Changes of Upper Trapezius Muscle Activity and EMG Gap After Transcutaneous Electrical Nerve Stimulation in Subjects With Myofascial Pain Syndrome (경피신경전기자극 후 상부 승모근 활성도와 EMG gap의 변화)

  • Koh, Eun-Kyung;Kwon, Oh-Yun;Yi, Chung-Hwi
    • Physical Therapy Korea
    • /
    • v.10 no.1
    • /
    • pp.37-50
    • /
    • 2003
  • The purpose of this study was to compare visual analogue scale (VAS), pain threshold (PT), $%RMS_{RVC}$, and EMG gaps before and after applying transcutaneous electrical nerve stimulation (TENS) on the upper trapezius muscle at the patients with myofascial pain syndrome (MPS). The subjects were 4 men and 10 women composed of both the inpatients and outpatients who were diagnosed as MPS at Wonju Medical Center. VAS and PT measurements were performed to assess the subjective pain level. The reference voluntary contraction (RVC) test was performed for 15 seconds for normalization on the bilateral trapezius muscle using surface electromyography (sEMG). After 3-minute resting time, the EMG signal was recorded while performing a typing activity for 2 minutes and then TENS was applicated with a comfortable intensity for 10 minutes. The EMG activity of the upper trapezius muscle was recorded during typing for 2 minutes. The results of study were as follows: 1) VAS score was significantly decreased on the more painful side after treatment, however, it was not significantly different on the less painful side. 2) PT was increased after treatment on both sides, however, it was not significantly different between before and after the TENS application. 3) The EMG activity during typing was significantly decreased after treatment, and 4) The EMG gaps were significantly increased after TENS treatment compared to before it. Consequently, the study showed that TENS was effective in decreasing VAS, $%RMS_{RVC}$, and in increasing EMG gaps. The EMG gap analysis could be a useful method to measure pain in patients with MPS in the upper trapezius.

  • PDF

Characteristics of Welds of Pure Titanium Plate Using Ultrasonic Attenuation (초음파 감쇠를 이용한 순 티타늄 판재의 용접부 특성)

  • Seon, Sang-Won;Yi, Won;Park, Hee-Dong;Hwang, Yeong-Tak
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.2
    • /
    • pp.205-211
    • /
    • 2013
  • This paper studies on mechanical properties, fractures, and ultrasonic characteristics of Pure Titanium welds using ultrasonic attenuation. Ti specimen was made by using AR purge gas. When the titanium weld specimen is fractured, Tensile tests were conducted in order to observe the ultrasonic signal changes. A scanning electron microscope(SEM) was used to observe changes in failure surface and an ultrasonic normal probe with the central frequency of 4 MHz was used to obtain ultrasonic signals. As a result, the value of the mechanical properties in the weld zone was lower than that in the base zone and heat affected zone(HAZ) from Ti. Also the grain size in the weld zone was bigger than that in the weld zone and HAZ from Ti. Ultrasonic signals using a RMS method presents correlation between envelope area and the tensile strength. Consequently, the ultrasonic method could be potential tool for integrity evaluation of the Ti weld zone.

Discrimination of Parkinson's Disease from Essential Tremor using Acceleration based Tremor Analysis (가속도계를 이용한 진전현상의 분석을 통한 파킨슨병과 본태성 진전의 판별)

  • Lee, Hongji;Lee, Woongwoo;Jeon, Hyoseon;Kim, Sangkyong;Kim, Hanbyul;Jeon, Beom S.;Park, Kwangsuk
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.4
    • /
    • pp.103-108
    • /
    • 2015
  • Discrimination of Parkinson's disease (PD) from Essential tremor (ET) is often misdiagnosed in clinical practice. Since tremor is time-varying signal, and dominant and harmonic frequencies are shown in tremor only with moderate or severe symptom, there are some limitations to use frequency related features. Moreover, patients with PD or ET can suffer from both resting tremor and postural tremor. In this study, 28 patients with PD and 17 patients with ET were enrolled. Tremor was measured with accelerations on the more affected hand during resting and postural conditions. The ratio of root mean square (RMS) of resting tremor to RMS of postural tremor, the mean coefficients of autocorrelation function (ACF), and the mean of differences of two adjacent coefficients of ACF at resting and postural were calculated and compared between PD and ET. The performance showed 98% accuracy with support vector machine and leave-one-out cross validation. In addition, the method accurately differentiated the patients with tremor-dominant PD from patients with ET, with 100% accuracy. Therefore, the developed algorithm can assist clinicians in diagnosing and categorizing patients with tremor, especially, patients with mild symptom or the early stage of a disease, for proper treatment.

Structuyal and physical properties of thin copper films deposited on porous silicon (다공성 실리콘위에 증착된 Cu 박막의 구조적 물리적 특성)

  • 홍광표;권덕렬;박현아;이종무
    • Journal of the Korean Vacuum Society
    • /
    • v.12 no.2
    • /
    • pp.123-129
    • /
    • 2003
  • Thin transparent Cu films in the thickness range of 10 ~ 40 nm are deposited by rf-magnetron sputtering on porous silicon (PS) anodized on p-type silicon in dark. Microstructural features of the Cu films are investigated using SEM, AFM and XRD techniques. The RMS roughness of the Cu films is found to be around 1.47 nm and the grain growth is columnar with a (111) preferred orientation and follows the Volmer-Weber mode. The photoluminescence studies showed that a broad luminiscence peak of PS near the blue-green region gets blue shifted (~0.05 eV) with a small reduction in intensity and therefore, Cu-related PL quenching is absent. The FTIR absorption spectra on the PS/Cu structure revealed no major change of the native PS peaks but only a reduction in the relative intensity. The I-V characteristic curves further establish the Schottky nature of the diode with an ideality factor of 2.77 and a barrier height of 0.678 eV. An electroluminiscence (EL) signal of small intensity could be detected for the above diode.

Atmospheric Correction of Arc-Rail Type GB-SAR Using Refractive Index of Air (대기 굴절률을 이용한 원형레일 기반 지상 SAR 자료의 대기보정)

  • Lee, Jae-Hee;Kim, Kwang-Eun;Cho, Seong-Jun;Sung, Nak-Hoon;Lee, Hoon-Yol
    • Korean Journal of Remote Sensing
    • /
    • v.28 no.2
    • /
    • pp.237-243
    • /
    • 2012
  • In this paper, an atmospheric effect of repetitive measurements of X-band (9.65 GHz) arc-rail type GB-SAR (ArcSAR) system was quantitatively analyzed. Four artificial triangular trihedral corner reflectors as stationary targets for getting stable back scattered signal during 43 hours continually. The results of the analysis showed that the phase of those stationary targets had changed maximum of 5 radian (12.4 mm) and total RMS error had was 1.62 radian (4 mm) during 65 repeated measuring time. The refractive index of air which was calculated using the temperature;humidity and pressure of atmosphere showed very close relationship with the phase difference. We could check the atmospheric correction was fulfilled by the correction of an atmospheric effect using refractive index during the selected 16 hours period showed that RMS error was dropped from 1.74 radian (4.3 mm) to 0.10 radian (0.24 mm).

Analysis of Angular Velocity during Toe Tapping for the Quantification of the Lower Limb Bradykinesia in Patients with Idiopathic Parkinson's Disease (특발성 파킨슨병 환자의 하지 완서증 정량화를 위한 발 두드리기 동작의 각속도 분석)

  • Kim, Ji-Won;Kwon, Yu-Ri;Eom, Gwang-Moon;Kim, Hyung-Sik;Yi, Jeong-Han;Kwon, Do-Young;Koh, Seong-Beom;Park, Byung Kyu;Kwon, Tae-Kyu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.11
    • /
    • pp.2114-2118
    • /
    • 2010
  • The purpose of this study was to analyze bradykinesia of toe tapping movement in patients with Parkinson's disease (PD) as compared to those of normal subjects. 39 PD patients (age: $65.5{\pm}11.2$ yrs, H&Y stage:$2.3{\pm}0.5$), 14 eldelry subjects with comparable mean age ($65.0{\pm}3.9$ yrs) and 17 healthy young subjects ($24.1{\pm}2.1$ yrs) participated in this study. Angular velocity during repetitive toe tapping movement was measured in both feet using a gyro sensor system. Suggested quantitative measures of bradykinesia were root-mean-squared (RMS) angular velocity, RMS angle, peak power and total power which were derived from the angular velocity signal. ANOVA showed that all measures were significantly different among three groups (p<0.001). Subsequent post-hoc test revealed that all measures in PD patients were significantly smaller than in healthy elderly and healthy young subjects (p<0.02). All measures were significantly correlated with UPDRS scores(r=-0.689~-0.825). These results suggest that the developed system can be used as quantitative measures of the lower limb bradykinesia in PD patients.

An Integrated Emergency Call System based on Public Switched Telephone Network for Elevators

  • Lee, Guisun;Ryu, Hyunmi;Park, Sunggon;Cho, Sungguk;Jeon, Byungkook
    • International journal of advanced smart convergence
    • /
    • v.8 no.3
    • /
    • pp.69-77
    • /
    • 2019
  • Today, most of elevators have an emergency call facility for emergency situations. However, if the network installed in the elevator is also out of power, it cannot be used for the elevator remote monitoring and management. So, we develop an integrated and unified emergency call system, which can transmit not only telephone call but also data signals using PSTN(Public Switched Telephone Network) in order to remote monitoring and management of elevators, even though a power outage occurs. The proposed integrated emergency call system to process multiple data such as voice and operational information is a multi-channel board system which is composed of an emergency phone signal processing module and an operational information processing module in the control box of elevator. In addition, the RMS(remote management server) systems based on the Web consist of a dial-up server and a remote monitoring server where manages the elevator's operating information, status records, and operational faults received via the proposed integrated and unified emergency call system in real time. So even if there's a catastrophic emergency, the proposed RMS systems shall ensure and maintain the safety of passengers inside the elevator. Also, remote control of the elevator by this system should be more efficient and secure. In near future, all elevator emergency call system need to support multifunctional capabilities to transmit operational data as well as phone calls for the safety of passengers. In addition, for safer elevators, it is necessary to improve them more efficiently by combining them with high-tech technologies such as the Internet of Things and artificial intelligence.

Developing GPS Code Multipath Grid Map (CMGM) of Domestic Reference Station (국내 기준국의 GPS 코드 다중경로오차 격자지도 생성)

  • Gyu Min Kim;Gimin Kim;Chandeok Park
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.13 no.1
    • /
    • pp.85-92
    • /
    • 2024
  • This study develops a Global Positioning System (GPS) Code Multipath Grid Map (CMGM) of each individual domestic reference station from the extracted code multipath of measurement data. Multipath corresponds to signal reflection/refraction caused by obstacles around the receiver antenna, and it is a major source of error that cannot be eliminated by differencing. From the receiver-independent exchange format (RINEX) data for two days, the associated code multipath of a satellite tracking arc is extracted. These code multipath data go through bias correction and interpolation to yield the CMGM with respect to the azimuth and elevation angles. The effect of the CMGM on multipath mitigation is then quantitatively analyzed to improve the Root Mean Square (RMS) of averaged pseudo multipath. Furthermore, the single point positioning (SPP) accuracy is analyzed in terms of the RMS of the horizontal and vertical errors. During two weeks in February 2023, the RMSs of the averaged pseudo multipath for five reference stations decreased by about 40% on average after CMGM application. Also, the SPP accuracies increased by about 7% for horizontal errors and about 10% for vertical errors on average after CMGM application. The overall quantitative analysis indicates that the proposed approach will reduce the convergence time of Differential Global Navigation Satellite System (DGNSS), Real-Time Kinematic (RTK), and Precise Point Positioning (PPP)-RTK correction information in real-time to use measurement data whose code multipath is corrected and mitigated by the CMGM.

Development of a Low-Noise Amplifier System for Nerve Cuff Electrodes (커프 신경전극을 위한 저잡음 증폭기 시스템 개발)

  • Song, Kang-Il;Chu, Jun-Uk;Suh, Jun-Kyo Francis;Choi, Kui-Won;Yoo, Sun-K.;Youn, In-Chan
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.1
    • /
    • pp.45-54
    • /
    • 2011
  • Cuff electrodes have a benefit for chronic electroneurogram(ENG) recording while minimizing nerve damage. However, the ENG signals are usually contaminated by electromyogram(EMG) activity from the surrounding muscle, the thermal noise generated within the source resistance, and the electric noise generated primarily at the first stage of the amplifier. This paper proposes a new cuff electrode to reduce the interference of EMG signals. An additional middle electrode was placed at the center of cuff electrode. As a result, the proposed cuff electrode achieved a higher signal-to-interference ratio compared to the conventional tripolar cuff. The cuff electrode was then assembled together with closure, headstage, and hermetic case including electronic circuits. This paper also presents a lownoise amplifier system to improve signal-to-noise ratio. The circuit was designed based on the noise analysis to minimize the electronic noise. The result shows that the total noise of the amplifier was below $1{\mu}V_{rms}$ for a cuff impedance of $1\;k{\Omega}$ and the common-mode rejection ratio was 115 dB at 1 kHz. In the current study, the performance of nerve cuff electrode system was evaluated by monitoring afferent nerve signals under mechanical stimuli in a rat animal model.