• Title/Summary/Keyword: RMS index

Search Result 77, Processing Time 0.026 seconds

Evaluation of Ride Comfort in Time Domain by Using z-Transform (z변환을 이용한 시간영역에서의 승차감 평가)

  • Kim, Young-Guk;Kim, Seog-Won;Park, Chan-Kyoung;Kim, Sang-Soo;Kim, Ki-Hwan
    • Journal of the Korean Society for Railway
    • /
    • v.14 no.6
    • /
    • pp.495-500
    • /
    • 2011
  • In evaluating the ride comfort of railway vehicles, relationship between passenger's feeling and vibration characteristics is very important because human feeling is dependent on frequency spectrum of vibration. Therefore, the weighing curves in frequency domain are used to evaluate the ride comfort of railway vehicles. These curves have been defined in the Laplace transfer functions. It is necessary to convert the Laplace weighing function to the z weighing function in order to obtain the rms value in the time domain. In the present paper, we have applied Tustin's approximation to transform the Laplace weighing function to the z weighing and validated this method by reviewing the various cases.

Analysis of Properties and Fabrication of $1000{\AA}$ silicon nitride MIM capacitor with High Breakdown Electric Field for InGaP/GaAs HBT Application (InGaP/GaAs HBT 적용을 위한 높은 절연강토의$1000{\AA}$ 실리콘 질화막 MIM capacitor제작과 특성 분석)

  • So, Soon-Jin;Oh, Doo-Suk;Sung, Ho-Kun;Song, Min-Jong;Park, Choon-Bae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.693-696
    • /
    • 2004
  • For InGaP/GaAs HBT applications, we have developed characterized MIM capacitors with thin $1000{\AA}$ PECVD silicon nitride which were deposited with $SiH_4/NH_3$ gas mixing rate, working pressure, and RF power of PECVD at $300^{\circ}C$ and had the capacitance density of 600 pF/$mm^2$ with the breakdown electric fields of 3073 MV/cm. Three PECVD process parameters were designed to lower the refractive index and then lower the deposition rate of silicon nitride films for the high breakdown electric field. At the PECVD process condition of gas mixing rate (0.92), working pressure (1.3 Torr), RF power (53 W), the AFM Rms value of about $1000{\AA}$ silicon nitride on the bottom metal was the lowest of 0.662 nmand breakdown electric fields were the highest of about 73 MV/cm.

  • PDF

Different Responses to Acupuncture in Electroencephalogram according to Stress Level: A Randomized, Placebo-Controlled, Cross-Over Trial (스트레스 정도에 따라 침 치료가 뇌파(EEG)에 미치는 영향: 무작위배정 플라시보 대조군 교차연구)

  • Kim, Song-Yi;Kim, Sang-Woo;Park, Hi-Joon
    • Korean Journal of Acupuncture
    • /
    • v.31 no.3
    • /
    • pp.136-145
    • /
    • 2014
  • Objectives : The purpose of this randomized, placebo-controlled, cross-over trial was to examine how acupuncture treatment at Shinmun(HT7) affects the brain activity and the autonomic nervous system(ANS), using electroencephalograms(EEG) and heart rate variability(HRV). Methods : Eighteen healthy volunteers participated in two separate experiments: in each experiment, either real acupuncture(RA) or non-penetrating sham acupuncture(SA) was applied at HT7 in random sequences to each person. The EEG and HRV measurements were conducted simultaneously before and during the acupuncture stimulation for 5 minutes, respectively. Resulting EEG and HRV parameters were compared between RA and SA groups. To assess differences according to the stress levels for participants, subgroup analysis was performed based on the results of the stress response index questionnaire. Results : In the results, acupuncture stimulation at HT7 increased ${\alpha}$ band in EEG. In the HRV analysis, heart rate was decreased significantly but HF and RMS-SD were increased in the RA group, compared with those of the SA group. In the subgroup analysis by stress level, participants in the RA group with high stress exhibited an increased in ${\alpha}$ band in their EEG while the low stress participants showed decrease or little increase in the band. For the SA group, ${\alpha}$ band reported relatively moderate changes in all channels. Conclusions : Our results showed that acupuncture induces changes in brain activation and the ANS. Acupuncture was related to the activation of the parasympathetic nervous system. The brain activities of the participants were different depending on the stress level.

Extrusion-cooking Using Twin-screw Extruder on Cordyceps Pruinosa (이축 압출 성형기를 이용한 붉은자루 동충하초의 압출 성형)

  • Kim D. E.;Sung J. M.;Kang W. S.
    • Journal of Biosystems Engineering
    • /
    • v.30 no.1 s.108
    • /
    • pp.8-16
    • /
    • 2005
  • The extrusion-cooking condition on Cordyceps pruinosa was designed using twin-screw extruder. Response surface methodology (RSM) was used to investigate extrusion-cooking using a central composition design with varying die temperature $(114-146^{\circ}C)$, feed moisture $(22-38\%)$, feed rate (4-14 ka/h) and screw speed (120-280 rpm). System parameters (die pressure and specific mechanical energy (SME)) and extrudate parameters (density and water solubility index (WSI)) were statically analyzed using RSH. Die pressure was significantly affected by temperature, moisture contents and feed rate. SM was affected by screw speed and feed rate. When die temperature is $130^{\circ}C$ and moisture content $25\%$, the optimum pressure is shown. SME is about 20 Wh/kg, when feed rate is $10\~12kg/min$ and screw speed $200\~250rpm$. WSI was affected by temperature and moisture contents. Density was not affected by any factor. WSI increases by $7\%$ from about $23\%$ to about $30\%$, as temperature is raised from $120^{\circ}C\;to\;140^{\circ}C$. The WSI of Cordyceps pruinosa pulverized after extruding (PE) is about $26.97\%$ higher than that of raw material and $10\%$ higher than that of pulverized after drying (PD). The content of unsaturated fatty acid were not significantly different in PD and PE. Anti-oxidative activity of PE was 1.67-2.2 times higher than that of PD in Cordyceps pruinosa using 1- dipheny1-2-picrylhydrazyl method (DPPH).

Clinical Usefulness of M-test on Patients with Chronic Neck Pain: A Single Arm Pre-post Comparison Study (M-test에 근거한 만성 경항통 환자의 진단 및 치료: 전후비교 임상연구)

  • Cho, Woo-Young;Chung, Seok-Hee
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.26 no.4
    • /
    • pp.67-75
    • /
    • 2016
  • Objectives The purpose of this study was to investigate the clinical usefulness of M-test (Meridian test) as an adjunctive evaluation and treatment in patients with chronic neck pain. Methods This study was a single arm pre-post comparison study. Thirty-six eligible subjects with chronic neck pain were recruited from August to September, 2015. M-test was used for evaluating the condition of meridian, which can induce the limitation of ROM and body discomfort. Subjects were offered intradermal acupuncture treatment on one-acupoint for 48 hours. Cervical numeric rating scale (NRS), cervical range of motion (ROM), neck disability index (NDI) and surface electromyography (SEMG) were measured before and after the treatment. Total NRS and the number of movement limitation of M-test were also measured before and after the treatment. Results Among the 36 participating subjects, 4 subjects were lost to follow-up or excluded in accordance with the criteria. Significant differences on Cervical NRS and NDI were found after the treatment (p<0.001). There was a significant difference in the range of left cervical rotation (p<0.05). Root mean square (RMS) of SEMG significantly decreased on the right sternocleidomastoid muscle (p<0.05), but significantly increased on the right trapezius muscle (p<0.05). Median frequency (MdF) of SEMG significantly increased on both sternocleidomastoid muscles. There appears to be significant differences after the treatment in total NRS and the number of movement limitation of M-test (p<0.05). Conclusions These results suggest that the evaluation and treatment of M-test based on the meridian and collateral theory were effective on cervical NRS and NDI, and also improved the movability of human body.

Performance evaluation method of homogeneous stereo camera system for full-field structural deformation estimation

  • Yun, Jong-Min;Kim, Ho-Young;Han, Jae-Hung;Kim, Hong-Il;Kwon, Hyuk-Jun
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.16 no.3
    • /
    • pp.380-393
    • /
    • 2015
  • This study presents how we can evaluate stereo camera systems for the structural deformation monitoring. A stereo camera system, consisting of a set of stereo cameras and reflective markers attached on the structure, is introduced for the measurement and the stereo pattern recognition (SPR) method is utilized for the full-field structural deformation estimation. Performance of this measurement system depends on many parameters including types and specifications of the cameras, locations and orientations of them, and sizes and positions of markers; it is difficult to experimentally identify the effects of each parameter on the measurement performance. In this study, a simulation framework for evaluating performance of the stereo camera systems with various parameters has been developed. The maximum normalized root-mean-square (RMS) error is defined as a representative index of stereo camera system performance. A plate structure is chosen for an introductory example. Its several modal harmonic vibrations are generated and estimated in the simulation framework. Two cases of simulations are conducted to see the effects of camera locations and the resolutions of the cameras. An experimental validation is carried out for a few selected cases from the simulations. Using the simultaneous laser displacement sensor (LDS) measurements as the reference, the measurement errors are obtained and compared with the simulations.

Fluorescence-labelling for analysis of protein in starch using asymmetrical flow field-flow fractionation (AF4)

  • Yoo, Yeongsuk;Choi, Jaeyeong;Zielke, Claudia;Nilsson, Lars;Lee, Seungho
    • Analytical Science and Technology
    • /
    • v.30 no.1
    • /
    • pp.1-9
    • /
    • 2017
  • Starch is a mixture of amylose (AMY) and amylopectin (AMP) which are different in physical properties such as molar mass (M), rms radius ($R_g$) and hydrodynamic diameter ($d_H$). The rheological and functional properties of starch are influenced by various factors including the molecular size, molar mass distribution (MD) and the concentration ratio of AMY and AMP. It is also important to analyze proteinaceous material in starch as they affect the flavor and texture of food to which starch is added. In this study, asymmetrical flow field-flow fractionation (AF4) was employed for separation and quantitation of AMY and AMP in starches (Amaranth, potato, taros and quinoa). AF4 was coupled with a multi-angle light scattering (MALS) and a refractive index (RI) detector for determination of the absolute M, MD and molecular structure. It was found that AMP has the M and $R_g$ ranging $3.7{\times}10^7{\sim}6.5{\times}10^8g/mol$ and 84 ~ 250 nm, respectively. Also the existence of branch was confirmed in higher M. In addition, proteinaceous material in starch was analyzed by AF4 coupled with a fluorescence detector (FS) after fluorescence-labeling. AF4-FS with fluorescence-labelling showed a potential for investigation on existence of proteinaceous material and the interaction between proteinaceous material and polysaccharide in starch.

Characterization of Alpha-Ga2O3 Template Grown by Halide Vapor Phase Epitaxy (HVPE 방법으로 성장한 Alpha-Ga2O3의 특성 분석)

  • Son, Hoki;Ra, Yong-Ho;Lee, Young-Jin;Lee, Mi-Jai;Kim, Jin-Ho;Hwang, Jonghee;Kim, Sun Woog;Lim, Tae-Young;Jeon, Dae-Woo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.31 no.6
    • /
    • pp.357-361
    • /
    • 2018
  • We demonstrated a crack-free ${\alpha}-Ga_2O_3$ on sapphire substrate by horizontal halide vapor phase epitaxy (HVPE). Oxygen-and gallium chloride-synthesized Ga metal and HCl were used as the precursors, and $N_2$ was used as the carrier gas. The HCl flow and growth temperature were controlled in the ranges of 10~30 sccm and $450{\sim}490^{\circ}C$, respectively. The surface of ${\alpha}-Ga_2O_3$ template grown at $470^{\circ}C$ was flat and the root-mean-square (RMS) roughness was ~2 nm. The full width at half maximum (FWHM) values for the symmetric-plane diffractions, were as small as 50 arcsec and those for the asymmetric-plane diffractions were as high as 1,800 arcsec. The crystal quality of ${\alpha}-Ga_2O_3$ on sapphire can be controlled by varying the HCl flow rate and growth temperature.

Improvement of Classification Accuracy of Different Finger Movements Using Surface Electromyography Based on Long Short-Term Memory (LSTM을 이용한 표면 근전도 분석을 통한 서로 다른 손가락 움직임 분류 정확도 향상)

  • Shin, Jaeyoung;Kim, Seong-Uk;Lee, Yun-Sung;Lee, Hyung-Tak;Hwang, Han-Jeong
    • Journal of Biomedical Engineering Research
    • /
    • v.40 no.6
    • /
    • pp.242-249
    • /
    • 2019
  • Forearm electromyography (EMG) generated by wrist movements has been widely used to develop an electrical prosthetic hand, but EMG generated by finger movements has been rarely used even though 20% of amputees lose fingers. The goal of this study is to improve the classification performance of different finger movements using a deep learning algorithm, and thereby contributing to the development of a high-performance finger-based prosthetic hand. Ten participants took part in this study, and they performed seven different finger movements forty times each (thumb, index, middle, ring, little, fist and rest) during which EMG was measured from the back of the right hand using four bipolar electrodes. We extracted mean absolute value (MAV), root mean square (RMS), and mean (MEAN) from the measured EMGs for each trial as features, and a 5x5-fold cross-validation was performed to estimate the classification performance of seven different finger movements. A long short-term memory (LSTM) model was used as a classifier, and linear discriminant analysis (LDA) that is a widely used classifier in previous studies was also used for comparison. The best performance of the LSTM model (sensitivity: 91.46 ± 6.72%; specificity: 91.27 ± 4.18%; accuracy: 91.26 ± 4.09%) significantly outperformed that of LDA (sensitivity: 84.55 ± 9.61%; specificity: 84.02 ± 6.00%; accuracy: 84.00 ± 5.87%). Our result demonstrates the feasibility of a deep learning algorithm (LSTM) to improve the performance of classifying different finger movements using EMG.

Estimation on the Depth of Anesthesia using Linear and Nonlinear Analysis of HRV (HRV 신호의 선형 및 비선형 분석을 이용한 마취심도 평가)

  • Ye, Soo-Young;Baik, Seong-Wan;Kim, Hye-Jin;Kim, Tae-Kyun;Jeon, Gye-Rok
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.1
    • /
    • pp.76-85
    • /
    • 2010
  • In general, anesthetic depth is evaluated by experience of anesthesiologist based on the changes of blood pressure and pulse rate. So it is difficult to guarantee the accuracy in evaluation of anesthetic depth. The efforts to develop the objective index for evaluation of anesthetic depth were continued but there was few progression in this area. Heart rate variability provides much information of autonomic activity of cardiovascular system and almost all anesthetics depress the autonomic activity. Novel monitoring system which can simply and exactly analyze the autonomic activity of cardiovascular system will provide important information for evaluation of anesthetic depth. We investigated the anesthetic depth as following 7 stages. These are pre-anesthesia, induction, skin incision, before extubation, after extubation, Post-anesthesia. In this study, temporal, frequency and chaos analysis method were used to analyze the HRV time series from electrocardiogram signal. There were NN10-NN50, mean, SDNN and RMS parameter in the temporal method. In the frequency method, there are LF and HF and LF/HF ratio, 1/f noise, alphal and alpha2 of DFA analysis parameter. In the chaos analysis, there are CD, entropy and LPE. Chaos analysis method was valuable to estimate the anesthetic depth compared with temporal and frequency method. Because human body was involved the choastic character.