• 제목/요약/키워드: RMS current

검색결과 343건 처리시간 0.028초

Comparison of PWM Strategies for Three-Phase Current-fed DC/DC Converters

  • Cha, Han-Ju;Choi, Soon-Ho;Han, Byung-Moon
    • Journal of Power Electronics
    • /
    • 제8권4호
    • /
    • pp.363-370
    • /
    • 2008
  • In this paper, three kinds of PWM strategies for a three-phase current-fed dc/dc converter are proposed and compared in terms of losses and voltage transfer ratio. Each PWM strategy is described graphically and their switching losses are analyzed. With the proposed PWM C strategy, one turn-off switching of each bridge switch is eliminated to reduce switching losses under the same switching frequency. In addition, RMS current through the bridge switches is lowered by using parallel connection between two bridge switches and thus, conduction losses of the switches are reduced. Further, copper losses of the transformer are decreased due to the reduced RMS current of each transformer's winding. Therefore, total losses are minimized and the efficiency of the converter is improved by using the proposed PWM C strategy. Digital signal processor (DSP: TI320LF2407) and a field-programmable gate array (FPGA: EPM7128) board are used to generate PWM patterns for three-phase bridge and clamp MOSFETs. A 500W prototype converter is built and its experimental results verify the validity of the proposed PWM strategies.

Analysis and Design of a Single-Phase Tapped-Coupled-Inductor Boost DC-DC Converter

  • Gitau, Michael Njoroge;Mwaniki, Fredrick Mukundi;Hofsajer, Ivan W.
    • Journal of Power Electronics
    • /
    • 제13권4호
    • /
    • pp.636-646
    • /
    • 2013
  • A single-phase tapped-inductor boost converter has been proposed previously. However, detailed characterization and performance analysis were not conducted. This paper presents a detailed characterization, performance analysis, and design expressions of a single-phase tapped-coupled-inductor boost converter. Expressions are derived for average and RMS input current as well as for RMS input and output capacitor current ripple. A systematic approach for sizing the tapped-coupled inductor, active switch, and output diode is presented; such approach has not been reported in related literature. This study reveals that sizing of the inductor has to be based on current ripple requirement, turns ratio, and load. Conditions that produce discontinuous inductor current are also discussed. Analysis of a non-ideal converter operating in continuous conduction mode is also conducted. The expression for the voltage ratio considering the coupling coefficient is derived. The suitability of the converter for high-voltage step-up applications is evaluated. Factors that affect the voltage boost ratio are also identified. The effects of duty ratio and load variation on the performance of the converter are also investigated. The theoretically derived characteristics are validated through simulations. Experimental results obtained at a low power level are included to validate the analytical and simulation results. A good agreement is observed among the analytical, simulation, and experimental results.

상반신의 근육뼈대계 통증이 치과위생사의 스케일링 작업에 미치는 특성에 대한 표면 근전도 분석 (Analysis Characteristic the Using Surface EMG of Scaling Working of the Dental Hygienist with Upper Body Musculoskeletal Pain)

  • 남건우;하미숙
    • 대한물리치료과학회지
    • /
    • 제19권4호
    • /
    • pp.1-6
    • /
    • 2012
  • Purpose : The current research examines the muscle activity that happens during scaling practice subject to 20 dental hygienic students with musculoskeletal pain and then propose a basic data according to the working attitude of the Dental Hygienist. Method : The Nordic-style questionnaire is used to define experimental group with musculoskeletal pain and control group. During the scaling the surface EMG device is used to measure the muscle activity of experimental and control group. Study design : The surface EMG is measure RMS(root mean square) of suboccipital muscle, biceps brachii, upper trapezius, and brachioradialis muscle activity. Results : In the experimental group, the RMS of upper trapezius and brachioradialis is increased during scaling practice(p<0.05), but the control group's RMS is not changed(p>0.05). Conclusion : Musculoskeletal pain may contribute to increase muscle activity of neck & arm during scaling practice. In the future we think there is a need to raise the office efficiency by subjecting to dental hyginiest that are in the clinics and performing experiments.

  • PDF

X-Band 6-Bit Phase Shifter with Low RMS Phase and Amplitude Errors in 0.13-㎛ CMOS Technology

  • Han, Jang-Hoon;Kim, Jeong-Geun;Baek, Donghyun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제16권4호
    • /
    • pp.511-519
    • /
    • 2016
  • This paper proposes a CMOS 6-bit phase shifter with low RMS phase and amplitude errors for an X-band phased array antenna. The phase shifter combines a switched-path topology for coarse phase states and a switch-filter topology for fine phase states. The coarse phase shifter is composed of phase shifting elements, single-pole double-throw (SPDT), and double-pole double-throw (DPDT) switches. The fine phase shifter uses a switched LC filter. The phase coverage is $354.35^{\circ}$ with an LSB of $5.625^{\circ}$. The RMS phase error is < $6^{\circ}$ and the RMS amplitude error is < 0.45 dB at 8-12 GHz. The measured insertion loss is < 15 dB, and the return losses for input and output are > 13 dB at 8-12 GHz. The input P1dB of the phase shifter achieves > 11 dBm at 8-12 GHz. The current consumption is zero with a 1.2-V supply voltage. The chip size is $1.46{\times}0.83mm^2$, including pads.

비대칭과도 전류와 과전류계전기의 동작시간 특성에 관한 연구 (Study on the Asymmetrical Fault Currents and the Operating Time Characteristics of OCR)

  • 김남호;김일남;박종근
    • 대한전기학회논문지
    • /
    • 제41권9호
    • /
    • pp.953-959
    • /
    • 1992
  • As the TC(time-current) curve corresponding to symmetrical time invariant RMS value has been traditionally chosen and used for setting the relay, it has caused the misoperation errors on relay coordination because of CT secondary current being actually an asymmetrical time varying RMS value. In this paper, an algorithm for calculating the relay operating time is developed to study the asymmetrical effect using the step-by-step method. We represent the relay operating time errors between with and without DC offset versus PSM(plug setting multiplier), TMS(time multiplier setting) and X/R ratio. And also we present the correction factor. Finally we confirm the validity of this technique through the case study.

패턴인식기법을 이용한 공구마멸상태의 분류 (The Classification of Tool Wear States Using Pattern Recognition Technique)

  • 이종항;이상조
    • 대한기계학회논문집
    • /
    • 제17권7호
    • /
    • pp.1783-1793
    • /
    • 1993
  • Pattern recognition technique using fuzzy c-means algorithm and multilayer perceptron was applied to classify tool wear states in turning. The tool wear states were categorized into the three regions 'Initial', 'Normal', 'Severe' wear. The root mean square(RMS) value of acoustic emission(AE) and current signal was used for the classification of tool wear states. The simulation results showed that a fuzzy c-means algorithm was better than the conventional pattern recognition techniques for classifying ambiguous informations. And normalized RMS signal can provide good results for classifying tool wear. In addition, a fuzzy c-means algorithm(success rate for tool wear classification : 87%) is more efficient than the multilayer perceptron(success rate for tool wear classification : 70%).

교류 발전기 고정자 사고 검출을 위한 최적 마더 웨이브릿의 선정 (A Selection of an Optimal Mother Wavelet for Stator Fault Detection of AC Generator)

  • 박철원
    • 전기학회논문지P
    • /
    • 제57권4호
    • /
    • pp.377-382
    • /
    • 2008
  • For stator winding protection of AC generator, KCL(Kirchhoff's Current Law) is widely applied. Actually a CRDR(Current Ratio Differential Relay) based on DFT(Discrete Fourier Transform) has been used for protecting generator. It has been pointed out that defects can occur during the process of transforming a time domain signal into a frequency domain one which can lead to loss of time domain information. Wavelets techniques are proposed for the analysis of power system transients. This paper introduces an algorithm to choose a suitable Mother Wave1et for generator stator fault detection. For optimal selection, we analyzed db(Daubechies), sym(Symlets), and coif(Coiflects) of Mother Wavelet. And we compared with performance of the choice algorithm using detail coefficients energy and RMS(root mean square) error. It can be improved the reliability of the conventional DFT based CRDR. The feasibility and effectiveness of the proposed scheme is proved with simulation using collected data obtained from ATP (Alternative Transient Program) package.

공진 회로를 이용한 Capacitor 전류 시험기 (Capacitor Withstand Current Tester using Resonant Circuit)

  • 이창현;강윤수;박도일;노정욱
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2020년도 전력전자학술대회
    • /
    • pp.85-87
    • /
    • 2020
  • 고전압 커패시터는 회로 전체 안전성의 이유로 신뢰도를 유지하는 것이 매우 중요하다. 따라서 커패시터는 다양한 특성에 대해 시험이 필요하며 이때 장비가 필요하게 된다. 커패시터 시험용 특성으론 용량, 내전압, 전압 변화량, Irms, Ipeak가 있는데, 이 중 전류(Irms, Ipeak) 시험기의 경우 시중에 거의 없고, 매우 고가에 거래가 되고 있다. 이는 기존 전류 시험기가 CCCV(constant current constant voltage) 충/방전 회로를 사용하여 높은 전력을 공급하는 Power Supply가 요구되기 때문이다. 본 논문은 상기 기존 기술의 문제점을 해결하고자 공진회로를 이용하여 새로운 커패시터 전류 시험기를 설계하였고, Simulation을 통해 제안 전류 시험기의 가능성을 검토하였다.

  • PDF

구리 안정화재가 있는 YBCO 박막형 초전도 선재의 과전류 통전 특성 (Over-current characteristics of YBCO coated conductors having Cu stabilizer)

  • 임성우;두호익;김혜림;현옥배;손송호;임지현;황시돌;오성용;한병성
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제10권1호
    • /
    • pp.10-14
    • /
    • 2008
  • Differently from BSCCO tapes which are fabricated by powder-in-tube method, the coated conductors are made by the evaporation of YBCO on metal substrate. Due to this structural merit, although the coated conductors are generally used for large current transportation, they are expected to be favorable to the purpose of the fault current limitation as well. In this study, using YBCO coated conductor having copper stabilizer formed by plating technique(produced by Superpower Co.), we investigated the over-current characteristics of the coated conductor. The coated conductors had 85 A $I_c$ and 90 K $T_c$. The resistance of the conductor was 0.93 $m{\Omega}/cm$ at 300 K and 0.17 $m{\Omega}/cm$ at the temperature right above $T_c$. To the coated conductors, we applied the voltages of the range from 150 $V_{rms}$ to 230 $V_{rms}$ and measured the V-I curves using four probe method. From the results, we could analyze the electric behavior of the coated conductor in flux flow state. As the current exceed $I_c$, the currents were distributed into the superconductor and metal stabilizer. The amounts of the currents shared through both current paths were calculated under the assumption that the ,Joule heating was perfectly eliminated by $LN_2$ surrounding the conductor. Finally, the condition for the stable current flowing state which does not affect the conductor was established from the analysis on the over-current characteristics.

개선된 Clamp Circuit 적용 ZVZCS FB DC/DC 컨버터 (An Improved ZVZCS PWM FB DC/DC Converter Using the Modified Clamp Circuit)

  • 김은수;조기연;김윤호;이진수
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.643-645
    • /
    • 1999
  • The conventional high frequency phase-shifted full bridge dc/dc converter has a disadvantage that a circulating current flows through transformer and switching devices during the freewheeling interval. Due to this circulating current, RMS current stress, conduction losses of transformer and switching devices are increased. To alleviate this problem, this paper provides a circulating current free type high frequency soft switching phase-shifted full bridge (FB) dc/dc converter with the modified energy recovery snubber (ERS) attached at the secondary side of transforemr.

  • PDF