• Title/Summary/Keyword: RMS converter

Search Result 105, Processing Time 0.025 seconds

The RMS Current Stress Reduction Technique in Link Capacitor of Two-stage AC/DC Converter (2단 AC/DC 컨버터의 링크 캐패시터 전류 스트레스 저감 기법)

  • Jang, Doo-Hee;Jung, Young-Jin;Roh, Chung-Wook;Hong, Sung-Soo;Han, Sang-Kyoo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.6
    • /
    • pp.449-456
    • /
    • 2009
  • The RMS(Root Mean Square) current stress reduction technique for the PFC link capacitor is proposed. Although the various parameter is exist for optimizing the link capacitor, the RMS current stress is the most weighty practical parameter. The proposed C-L filter can reduce effectively the RMS current stress by filtering the output current. And with the C-L-L-C filter proposed in this paper, the more RMS current stress can be reduce because it filters not only the output current, like C-L filter, but also the input current of DC/DC stage. The proposed filter is simple to design and have no effect on the control part of the PFC because of the very low crossover frequency. To confirm the validity of proposed filter, theoretical analysis, the design guide, verification of experimental results are presented.

Development of new Multifunction Voltage Recorder (다기능 디지털 전압기록장치 시스템 개발)

  • Shon, Su-Goog;Choi, Sang-Joon
    • Proceedings of the KIEE Conference
    • /
    • 1999.11c
    • /
    • pp.693-696
    • /
    • 1999
  • This paper describes a new voltage recorder for the voltage management of a power distribution line by using a new voltage measurement technique. The RMS(Root Mean Square) voltage measurement for the power line under the assumption of a sinusoidal input voltage is taken by the full-wave rectifier, half-adder utilizing operational amplifier(OP) circuit. A/D converter utilizing a dual slope converter converts an analog voltage signal into a serial pulse. The pulse is counted with a single chip micro-controller, converted with the RMS voltage, and saved into a flash memory. In the last, a new voltage recorder with compact size and multifunction is developed. Also, Voltage Management System that can analyze the stored data via RS-232C cable is developed based on Windows 95 and Visual C++.

  • PDF

A Study on Switching Method to Minimize Inductor Current of Multi-Level Dual Active Bridge DC-DC Converter (Multi-Level Dual Active Bridge DC-DC Converter의 인덕터 전류를 최소화하기 위한 스위칭 방법에 관한 연구)

  • Han, Sang-Hyup;Kim, Heung-Geun;Cha, Honnyong;Chu, Tea-Won;Nho, Eui-Cheol
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.240-241
    • /
    • 2017
  • 멀티레벨 방식의 Dual Active Bridge 컨버터는 기존의 컨버터와 비교하여 높은 자유도의 스위칭 방식을 가진다. 본 논문에서는 멀티 레벨 방식의 DAB 컨버터의 동작원리를 분석하고, 인덕터 전류의 RMS 값과 THD를 최소화하기 위하여 기본파를 제외한 3 고조파와 5 고조파를 감쇄하는 스위칭 방식을 제안한다. 다양한 스위칭 패턴에 따른 인덕터 전류 RMS 값과 THD를 비교하여 제안하는 스위칭 방식의 타당성을 검증하고자 한다.

  • PDF

Indirect Cutting Force Measurement and Cutting Force Regulation Using Spindle Motor Current (주축모터 전류를 통한 절삭력의 간접 측정 및 절삭력 추종제어)

  • Kim, Gi D.;Kwon, Won T.;Chu, Chong N.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.10
    • /
    • pp.15-27
    • /
    • 1997
  • Quasti-static cutting force variations in milling process are measured indirectly using spindle motor current. Quasi-static sensitivity of the spindle motor current is higher than that of the feed motor current. Magnitude of the spindle motor current is independent of cutting direction. The linear relationship between the cutting force and the spimdle motor RMS current at various spindle rotational speed is obtained. Frequency/ Voltage(F/V) converter voltage is measured to identify the spindle speed and to determine the cutting force at various spindle speeds. Overload on the tool during milling process can be detected using the proposed indirect cutting force measurement. Based on these measurements, cutting force is regulated at a constant level by feedrate control.

  • PDF

Development of Remote Diagnosis System to Accumulate Abnormal Signal Data of Transformer (변압기의 이상 신호 데이터를 축적하기 위한 원거리 진단 시스템 개발)

  • Kwak, Seung Soo;Kim, Yong Sin
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2019.07a
    • /
    • pp.161-162
    • /
    • 2019
  • 본 논문에서는 변압기의 이상 신호 데이터를 원거리에서 축적하기 위한 이상 신호 진단 시스템을 제안한다. 이 시스템은 원격으로 변압기의 이상 신호를 수집하여 변압기의 이상을 알아낼 수 있다. 이 시스템은 상용된 통신 모듈의 느린 통신 속도를 고려하여 이상 신호를 RMS-DC 값으로 변환하는 작업을 추가하였다.

  • PDF

A Single-Stage LED Tube Lamp Driver with Input-Current Shaping for Energy-Efficient Indoor Lighting Applications

  • Cheng, Chun-An;Chang, Chien-Hsuan;Cheng, Hung-Liang;Chung, Tsung-Yuan;Tseng, Ching-Hsien;Tseng, Kuo-Ching
    • Journal of Power Electronics
    • /
    • v.16 no.4
    • /
    • pp.1288-1297
    • /
    • 2016
  • This study proposes a single-stage light-emitting diode (LED) tube lamp driver with input-current shaping for T8/T10-type fluorescent lamp replacements. The proposed AC-DC LED driver integrates a dual-boost converter with coupled inductors and a half-bridge series-resonant converter with a bridge rectifier into a single-stage power conversion topology. This paper presents the operational principles and design considerations for one T8-type 18 W-rated LED tube lamp with line input voltages ranging from 100 V rms to 120 V rms. Experimental results for the prototype driver show that the highest power factor (PF = 0.988), lowest input current total harmonic distortion (THD = 7.22%), and highest circuit efficiency (η = 92.42%) are obtained at an input voltage of 120 V. Hence, the proposed driver is feasible for use in energy-efficient indoor lighting applications.

Short-circuit Analysis by the Application of Control Signal of Power Converter to the Inductive Fault Current Limiter

  • Ahn, Min-Cheol;Hyoungku Kang;Bae, Duck-Kweon;Minseok Joo;Park, Dong-Keun;Lee, Sang-Jin;Ko, Tae-Kuk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.6 no.2
    • /
    • pp.25-28
    • /
    • 2004
  • Three-phase inductive superconducting fault current limiter (SFCL) with DC reactor rated on 6.6 $KV_{rms}/200 A_{rms}$ has been developed in Korea. This system consists of one DC reactor, AC/DC power converter, and a three-phase transformer, which is called magnetic core reactor (MCR). This paper deals with the short-circuit analysis of the SFCL. The DC reactor was the HTS solenoid coil whose inductance was 84mH. The power converter was performed as the dual-mode operation for dividing voltage between the rectifying devices. The short-term normal operation (1 see) and short-circuit tests (2∼3 cycles) of this SFCL were performed successfully. In regular short-circuit test, the fault current was limited as 30% of rated short-circuit current at 2 cycles after the fault. The experimental results have a very similar tendency to the simulation results. Using the technique for the fault detection and SCR firing control, the fault current limiting rate of the SFCL was improved. From this research, the parameters for design and manufacture of large-scale SFCL were obtained.

Optimized Operation of Dual-Active-Bridge DC-DC Converters in the Soft-Switching Area with Triple-Phase-Shift Control at Light Loads

  • Jiang, Li;Sun, Yao;Su, Mei;Wang, Hui;Dan, Hanbing
    • Journal of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.45-55
    • /
    • 2018
  • It is usually difficult for dual-active-bridge (DAB) dc-dc converters to operate efficiently at light loads. This paper presents an in-depth analysis of a DAB with triple-phase-shift (TPS) control under the light load condition to overcome this problem. A kind of operating mode which is suitable for light load operation is analyzed in this paper. First, an analysis of the zero-voltage-switching (ZVS) constraints for the DAB converter has been carried out and a reasonable dead-band setting method has been proposed. Secondly, the basic operating characteristics of the converter are analyzed. Third, under the condition of satisfying the ZVS constraints, both the reactive power and the root mean square (RMS) value of the current are simultaneously minimized and a particle swarm optimization (PSO) algorithm is employed to analyze and solve this optimization problem. Lastly, both simulations and experiments are carried out to verify the effectiveness of the proposed method. The experimental results show that the converter can effectively achieve ZVS and improved efficiency.

Dual Utility AC Line Voltage Operated Voltage Source and Soft Switching PWM DC-DC Converter with High Frequency Transformer Link for Arc Welding Equipment

  • Morimoto Keiki;Ahmed NabilA.;Lee Hyun-Woo;Nakaoka Mutsuo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.5B no.4
    • /
    • pp.366-373
    • /
    • 2005
  • This paper presents two new circuit topologies of the dc busline side active resonant snubber assisted voltage source high frequency link soft switching PWM full-bridge dc-dc power converters acceptable for either utility ac 200V-rms or ac 400V-rms input grid. These high frequency switching dc-dc converters proposed in this paper are composed of a typical voltage source-fed full-bridge PWM inverter, high frequency transformer with center tap, high frequency diode rectifier with inductor input filter and dc busline side series switches with the aid of a dc busline parallel capacitive lossless snubber. All the active switches in the full-bridge arms as well as dc busline snubber can achieve ZCS turn-on and ZVS turn-off transition commutation with the aid of a transformer leakage inductive component and consequently the total switching power losses can be effectively reduced. So that, a high switching frequency operation of IGBTs in the voltage source full bridge inverter can be actually designed more than about 20 kHz. It is confirmed that the more the switching frequency of full-bridge soft switching inverter increases, the more soft switching PWM dc-dc converter with a high frequency transformer link has remarkable advantages for its power conversion efficiency and power density implementations as compared with the conventional hard switching PWM inverter type dc-dc power converter. The effectiveness of these new dc-dc power converter topologies can be proved to be more suitable for low voltage and large current dc-dc power supply as arc welding equipment from a practical point of view.

Efficiency analysis of active-clamped current-fed half-bridge converter (능동 클램프형 전류원 하프브리지 컨버터의 효율 특성 분석)

  • Park, Jin-Ju;Lim, Jeong-Gyu;Chung, Se-Kyo;Song, Yujin
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.157-158
    • /
    • 2011
  • An active-clamped current-fed half-bridge converter is used for front-end converter for grid-connection of low voltage energy sources. In this paper, theoretical analysis on the loss and efficiency for an active-clamped current-fed half-bridge converter is presented. To analyze the loss of the presented converter, the RMS current of each device is derived and it's loss is calculated. The comparison between simulation result and computed value is presented to verify the validity of the theoretic results.

  • PDF