• Title/Summary/Keyword: RL

Search Result 438, Processing Time 0.029 seconds

Comparison of the Results of Multistix$^{(R)}$SG and Comber-9-Test$^{(R)}$ RL Urine Dipstick Assay (Multistix$^{(R)}$-SG와 Comgur-9-test$^{(R)}$RL에 의한 요시험지봉검사 성적의 비교)

  • Kim, Dae-Chul;Kim, Kyung-Dong;Jung, Bo-Chan;Kim, Chung-Sook;Cho, Kil-Ho
    • Journal of Yeungnam Medical Science
    • /
    • v.8 no.1
    • /
    • pp.42-52
    • /
    • 1991
  • Two types of urine dipstick assays, Multistix-SG and Combur-9-test RL, were compared for compatibility, accuracy, specificity and predictive values of a positive and negative test in 501 patients urine and artificially prepared specimen. We found that the results of semiquantitative tests of Multistix-SG and Combur-9-Test RL performed were statistically similar in patients specimen. The urinary leukocyte estrase tests of Combur-9-Test RL assays compared with urine sediment microscopy in regard to compatibility, sensitivity, specificity, and predictive values of a positive and negative test 83.7%, 48.1%, 90.3%, 47.4% and 90.1%, respectively. The urinar nitrite tests of Comber-9-Test RL assays compared with urine culture tests, in regard to compatibility, sensitivity, specificity, and predictive values of a positive and negative tests were 90.3%, 19.4%, 84.7%, 53.8% and 94.1%, respectively. For the urinary protein, the sulfosalicylic acid method was the most sensitive test for any kinds of protein, and Multistix-SG appeared more sensitive than Compur-9-Test RL for the albuminuria. For the urinary bilirubin and glusose, two dipstick assays were similar in their diganostic efficiency. Finally in the urinary occult blood tests, Combur-9-Test RL assays was more sensitive than Multistix-SG.

  • PDF

Potential-based Reinforcement Learning Combined with Case-based Decision Theory (사례 기반 결정 이론을 융합한 포텐셜 기반 강화 학습)

  • Kim, Eun-Sun;Chang, Hyeong-Soo
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.15 no.12
    • /
    • pp.978-982
    • /
    • 2009
  • This paper proposes a potential-based reinforcement learning, called "RLs-CBDT", which combines multiple RL agents and case-base decision theory designed for decision making in uncertain environment as an expert knowledge in RL. We empirically show that RLs-CBDT converges to an optimal policy faster than pre-existing RL algorithms through a Tetris experiment.

Comparing English and Korean speakers' word-final /rl/ clusters using dynamic time warping

  • Cho, Hyesun
    • Phonetics and Speech Sciences
    • /
    • v.14 no.1
    • /
    • pp.29-36
    • /
    • 2022
  • The English word-final /rl/ cluster poses a particular problem for Korean learners of English because it is the sequence of two sounds, /r/ and /l/, which are not contrastive in Korean. This study compared the similarity distances between English and Korean speakers' /rl/ productions using the dynamic time warping (DTW) algorithm. The words with /rl/ (pearl, world) and without /rl/ (bird, word) were recorded by four English speakers and four Korean speakers, and compared pairwise. The F2-F1 trajectories, the acoustic correlate of velarized /l/, and F3 trajectories, the acoustic correlate of /r/, were examined. Formant analysis showed that English speakers lowered F2-F1 values toward the end of a word, unlike Korean speakers, suggesting the absence of /l/ in Korean speakers. In contrast, there was no significant difference in F3 values. Mixed-effects regression analyses of the DTW distances revealed that Korean speakers produced /r/ similarly to English speakers but failed to produce the velarized /l/ in /rl/ clusters.

Formal Model of Extended Reinforcement Learning (E-RL) System (확장된 강화학습 시스템의 정형모델)

  • Jeon, Do Yeong;Song, Myeong Ho;Kim, Soo Dong
    • Journal of Internet Computing and Services
    • /
    • v.22 no.4
    • /
    • pp.13-28
    • /
    • 2021
  • Reinforcement Learning (RL) is a machine learning algorithm that repeat the closed-loop process that agents perform actions specified by the policy, the action is evaluated with a reward function, and the policy gets updated accordingly. The key benefit of RL is the ability to optimze the policy with action evaluation. Hence, it can effectively be applied to developing advanced intelligent systems and autonomous systems. Conventional RL incoporates a single policy, a reward function, and relatively simple policy update, and hence its utilization was limited. In this paper, we propose an extended RL model that considers multiple instances of RL elements. We define a formal model of the key elements and their computing model of the extended RL. Then, we propose design methods for applying to system development. As a case stud of applying the proposed formal model and the design methods, we present the design and implementation of an advanced car navigator system that guides multiple cars to reaching their destinations efficiently.

An Integrated System for Radioluminescence, Thermoluminescence and Optically Stimulated Luminescence Measurements

  • Park, Chang-Young;Park, Young-Kook;Chung, Ki-Soo;Lee, Jong-Duk;Lee, Jungil;Kim, Jang-Lyul
    • Journal of Radiation Protection and Research
    • /
    • v.43 no.4
    • /
    • pp.160-169
    • /
    • 2018
  • Background: This study aims to develop an integrated optical system that can simultaneously or selectively measure the signals obtained from radioluminescence (RL), thermoluminescence (TL), and optically stimulated luminescence (OSL), which are luminescence phenomena of materials stimulated by radioactivity, heat, and light, respectively. The luminescence mechanism of various materials could be investigated using the glow curves of the luminescence materials. Materials and Methods: RL/TL/OSL integrated measuring system was equipped with a X-ray tube (50 kV, $200{\mu}A$) as an ionizing radiation source to irradiate the sample. The sample substrate was used as a heating source and was also designed to optically stimulate the sample material using various light sources, such as high luminous blue light emitting diode (LED) or laser. The system measured the luminescence intensity versus the amount of irradiation/stimulation on the sample for the purpose of measuring RL, TL and OSL sequentially or by selectively combining them. Optical filters were combined to minimize the interference of the stimulation light in the OSL signal. A long-pass filter (420 nm) was used for 470 nm LED, an ultraviolet-pass filter (260-390 nm) was used for detecting the luminescence of the sample by PM tube. Results and Discussion: The reliability of the system was evaluated using the RL/OSL characteristics of $Al_2O_3:C$ and the RL/TL characteristics of LiF:Mg,Cu,Si, which were used as dosimetry materials. The RL/OSL characteristics of $Al_2O_3:C$ showed relatively linear dose-response characteristics. The glow curve of LiF:Mg,Cu,Si also showed typical RL/OSL characteristics. Conclusion: The reliability of the proposed system was verified by sequentially measuring the RL characteristics of radiation as well as the TL and OSL characteristics by concurrent thermal and optical stimulations. In this study, we developed an integrated measurement system that measures the glow curves of RL/TL/OSL using universal USB-DAQs and the control program.

Study on the Surface Activity of Rhamnolipid (RL) and Function of RL in Liquid Detergent (람노리피드의 계면특성 및 액체세정제에서의 기능에 대한 연구)

  • Chi, Gyeong-Yup;Lim, JongChoo
    • Applied Chemistry for Engineering
    • /
    • v.29 no.6
    • /
    • pp.753-758
    • /
    • 2018
  • Surface activities including CMC, surface tension, foaming power etc. of the rhamnolipid (RL), a biosurfactant fermented by microorganism were investigated. Both the RL and liquid detergent contained RL showed a good surface activity. For the detergency test, the liquid detergent with RL showed a slightly better performance than that of using an fatty acid. However for the foaming profile, the liquid detergent with RL exhibited a lot of foam volume and the suppression of the rinsing and foaming during rinsing cycles with the RL was not seen. Therefore it can be concluded that RL can be used as a main surfactant or co-surfactant in liquid detergents without functions of foaming suppression or rinse-aid.

Microencapsulation of Nalidixic Acid Using Eudragit RL (Nalidixic Acid의 Eudragit RL Microencapsulation에 관한 연구)

  • Ku, Young-Soon;Choi, Kyung-Joo
    • YAKHAK HOEJI
    • /
    • v.34 no.3
    • /
    • pp.199-205
    • /
    • 1990
  • Microencapsulation of nalidixic acid using Eudragit RL, a methacrylic acid copolymer was investigated. Microcapsules were prepared by dispersing the drug solution in liquid paraffing using aluminium tristearate as dispersing agent. The preparation of the microcapsules showed high reprodulibility in particle size, shape and the drug content. The dissolution rates of Nalidixic acid from the these microcapsules considerably decreased as compared with that from Nalidixic acid powder and Nalidixic acid-Eudragit RL solid dispersions. The release of Nalidixic acid increased with increasing percentage of aluminium tristearate added to the microcapsules.

  • PDF

An Image Segmentation Method for Richardson-Lucy Deconvolution Algorithm Improvement (영상 분할을 통한 Richardson-Lucy 디컨벌루션 개선 알고리듬)

  • Kim, Jeonghwan;Park, Daejun;Jeon, Jechang
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2015.11a
    • /
    • pp.114-117
    • /
    • 2015
  • 본 논문에서는 Non-blind 디컨벌루션 알고리듬 중 하나인 Richardson-Lucy(RL) 디컨벌루션을 영상 분할을 통해 성능을 향상시킨 알고리듬을 제안한다. RL 디컨벌루션은 영상의 크기가 커질수록 연산 양이 크게 증가한다. 따라서 크기가 큰 영상의 RL 디컨벌루션은 계산에 많은 시간을 필요로 한다. 이를 개선하기 위하여 영상을 적절한 크기로 분할하여 각각 RL 디컨벌루션을 계산한다. 또한 분할 시 생기는 왜곡을 줄이기 위해 리플 제거를 위한 알고리듬을 추가한다. 이를 통해 기존의 알고리듬보다 연산 양을 줄여 빠른 RL 디컨벌루션이 가능하도록 개선한다.

  • PDF

Flow Condensation Heat Transfer Coefficients of Pure Refrigerants (순수냉매의 흐름응축 열전달계수)

  • 김신종;송길홍;정동수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.2
    • /
    • pp.175-183
    • /
    • 2002
  • Flow Condensation heat transfer coefficients (HTCs) of Rl2, R22, R32, Rl23, Rl25, R134a, R142b were measured experimentally on a horizontal plain tube. The experi- mental apparatus was composed of three main parts; a refrigerant loop, a water loop and a water-glycol loop. The test section in a refrigerant loop was made of a copper tube of 8.8 mm inner diameter and 1000 mm length respectively. The refrigerant was cooled by passing cold water through an annulus surrounding the test section. All tests were performed at a filed refrigerant saturation temperature of 4$0^{\circ}C$ with mass fluxes of 100, 200, 300 kg/$m^2$s. The experimental result showed that flow condensation HTCs increase as the quality, mass flux, and latent heat of condensation increase. At the same mass flux, the HTCs of R32 and R142b were higher than those of R22 by 35~45% and 7~14% respectively while HTCs of R134a and Rl23 were similar to those of R22. On the other hand, HTCs of Rl25 and Rl2 were lower than those of R22 by 28 ~30% and 15 ~25% respectively Finally, a new correlation for flow condensation HTCs was developed by modifying Dobson and Chato's correlation with the latent heat of condensation considered. The correlaton showed an average deviation of 13.1% for all pure fluids data indicating an excellent agreement.

The Effect of Abutment Inclined Angle on the Marginal Fit of Zirconia All-ceramic Crown (지대주 경사각이 지르코니아 전부도재관의 변연적합도에 미치는 영향)

  • Lee, Seo-Yeon;Chung, In-Sung;Jeon, Byung-Wook
    • Journal of Technologic Dentistry
    • /
    • v.38 no.3
    • /
    • pp.111-117
    • /
    • 2016
  • Purpose: The present study was performed to investigate the effect of abutment inclined angle on the marginal fit of zirconia all-ceramic crown. Methods: The Ti abutments with 3 different inclined angle($2^{\circ}$, $4^{\circ}$ and $6^{\circ}$) were fabricated. The zirconia copings were fabricated for each abutment by using dental CAD/CAM system. The manufactured zirconia copings were duplicated through silicone replica technique, and a replicated specimen was sectioned in the center of bucco-lingual and mesio-distal axial to measure the marginal fit by using a stereo microscope. The results were analyzed using a one-way ANOVA with SPSS 22.0 for Windows(${\alpha}=0.05$). Results: On the bucco-lingual axial, marginal fit was the RL3($41.5{\pm}3.4{\mu}m$), RL2($44.3{\pm}4.3{\mu}m$) and RL1($47.5{\pm}5.7{\mu}m$), respectively. On the mesio-distal axial, marginal fit was the RL3($41.1{\pm}3.7{\mu}m$), RL2($45.7{\pm}5.3{\mu}m$) and RL1($46.2{\pm}4.5{\mu}m$), respectively. One-way ANOVA showed statistically significant difference between groups for marginal fit(p<0.05). Conclusion: For marginal fit of the abutments inclined angle, RL3 specimen was superior. The abutment inclined angle had influence on marginal fit of the zirconia copings. The marginal fit of each group were within clinically acceptable range.