• Title/Summary/Keyword: RIV 기법

Search Result 8, Processing Time 0.022 seconds

A Stochastic Model for the Prediction of Water Quality Variations in a River System (하천 수질변동의 예측을 위한 추계학적 수질해석 모형의 개발)

  • Han, Kun-Yeun;Kim, Sang-Hyun;Park, Jae-Hong
    • Water for future
    • /
    • v.28 no.2
    • /
    • pp.103-114
    • /
    • 1995
  • A stochastic model "STO-RIV" for the prediction of water quality variation in a river system has been developed. Extended Streeter-Phelps equation and Monte Carlo simulation are used in the model. The model is applied to the reach of Waegwan to Mulkeum in the Nakdong River to compute the probability distribution of BOD and DO concentration at Mulkeum site. As the strategies to attain the goal of the water quality, some alternatives considering the treatment effect of the Keumho river are discussed using the stochastic model. Application of stochastic analysis to water quality management is strongly recommended in this country.s country.

  • PDF

An Application of the On Line Partial Discharge Measurement Method in Transformer (온라인 변압기 부분방전 측정기법 적용)

  • Kweon, Dong-Jin
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.8
    • /
    • pp.394-400
    • /
    • 2001
  • This paper describes an application of the on line partial discharge measurement method in operating transformer. In the operating transformer, the partial discharge signal may be superimposed by radio intereference voltage(RIV) and pulse shaped noise signals generated by external corona. The partial discharge quantity showed about 3,800pC due to very high sinusoidal interferences at the measuring impedance terminal of the transformer bushing tap. In order to reject these noises, this paper applied RIV filter, band-pass filters and noise gating method. The resulting measuring sensitivity was improved from 3,800pC to 160pC.

  • PDF

Water Quality Model for the Toxic Pollutant Transport Analysis in the Nakdong River (낙동강 유역에서의 독성오염물 배출에 따른 수질해석 모형의 개발)

  • 한건연;김광섭
    • Water for future
    • /
    • v.28 no.1
    • /
    • pp.57-70
    • /
    • 1995
  • A water quality model RIV-LAGI for the toxic pollutant transport analysis is developed based on varied flow analysis and one-dimensional Lagrangian method. Applying to the prismatic channel, it shows accurate results compared with the analytical solutions. The model is applied to the Nakdong River to analyze the phenol spill accident, which occurred on March, 1991. The computed results have good agreements with the observed data. The travel times in the reach of Gumi to Mulkeum based on the monthly average and minimum flow are computed. The suggested model can be used to study the impact of the chemical spills and clean-up plans in the Nakdong River.

  • PDF

On Line Partial Discharge Measurement Method for Transformer (온라인 변압기 부분방전 측정기법)

  • Kweon, Dong-Jin;Choi, In-Hyuk;Song, Il-Keun;Park, Jae-Jun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05c
    • /
    • pp.38-42
    • /
    • 2001
  • This paper describes an application of the on line partial discharge measurement method in operating transformer. In the operating transformer, the partial discharge signal may be superimposed by radio intereference voltage(RIV) and pulse shaped noise signals generated by external corona. The partial discharge quantity showed about 3,800pC due to very high sinusoidal interferences at the measuring impedance terminal of the transformer bushing tap. In order to reject these noises, this paper applied RIV filter, band-pass filters and noise gating method. The resulting measuring sensitivity was improved from 3,800pC to 160pC.

  • PDF

Temperature Control of Electric Furnaces using Adaptive Time Optimal Control (적응최적시간제어를 사용한 전기로의 온도제어)

  • Jeon, Bong-Keun;Song, Chang-Seop;Keum, Young-Tag
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.5
    • /
    • pp.120-127
    • /
    • 2009
  • An electric furnace, inside which desired temperatures are kept constant by generating heat, is known to be a difficult system to control and model exactly because system parameters and response delay time vary as the temperature and position are changed. In this study the heating system of ceramic drying furnaces with time-varying parameters is mathematically modeled as a second order system and control parameters are estimated by using a RIV (Recursive Instrumental-Variable) method. A modified bang-bang control with magnitude tuning is proposed in the time optimal temperature control of ceramic drying electric furnaces and its performance is experimentally verified. It is proven that temperature tracking of adaptive time optimal control using a second order model is more stable than the GPCEW (Generalized Predictive Control with Exponential Weight) and rapidly settles down by pre-estimation of the system parameters.

Application of the Partial Discharge Measuring Method in Operating Transformer (운전중인 변압기의 부분방전 측정기법 적용)

  • 권동진;최인혁;정길조
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.94-98
    • /
    • 2000
  • This paper describes an application of the partial discharge measuring method in operating transformer. In the operating transformer, the useful PD signal may be superimposed by radio intereference voltage and impulse shaped noise signals generated by external corona or power electronics. In this paper, initial investigations after connecting the PD measuring system to the terminals of the measuring impedance showed a very high noise level of 3,700pC due to sinusoidal interferences. In order to reject these noises, this paper applied RIV and band-pass filters and noise gating method. The resulting measuring sensitivity was improved from 3,700pC to 160pC.

  • PDF

Effect of Areal Mean Rainfall Estimation Technique and Rainfall-Runoff Models on Flood Simulation in Samcheok Osipcheon(Riv.) Basin (면적 강우량 산정 기법과 강우-유출 모형이 삼척오십천 유역의 홍수 모의에 미치는 영향)

  • Lee, Hyeonji;Shin, Youngsub;Kang, Dongho;Kim, Byungsik
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.43 no.6
    • /
    • pp.775-784
    • /
    • 2023
  • In terms of flood management, it is necessary to analyze quantitative rainfall and runoff from a spatial and temporal perspective and to analyze runoff for heavy rainfall events that are concentrated within a short period of time. The simulation and analysis results of rainfall-runoff models vary depending on the type and input data. In particular, rainfall data is an important factor, so calculating areal mean rainfall is very important. In this study, the areal mean rainfall of the Samcheok Osipcheon(Riv.) watersheds located in the mountainous terrain was calculated using the Arithmetic Mean Method, Thiessen's Weighting Method, and the Isohyetal Method, and the rainfall-runoff results were compared by applying the distributional model S-RAT and the lumped model HEC-HMS. The results of the temporal transferability study showed that the combination of the distributional model and the Isohyetal Method had the best statistical performance with MAE of 64.62 m3/s, RMSE of 82.47 m3/s, and R2 and NSE of 0.9383 and 0.8547, respectively. It is considered that this study was properly analyzed because the peak flood volume occurrence time of the observed and simulated flows is within 1 hour. Therefore, the results of this study can be used for frequency analysis in the future, which can be used to improve the accuracy of simulating peak flood volume and peak flood occurrence time in mountainous watersheds with steep slopes.

Development and run time assessment of the GPU accelerated technique of a 2-Dimensional model for high resolution flood simulation in wide area (광역 고해상도 홍수모의를 위한 2차원 모형의 GPU 가속기법 개발 및 실행시간 평가)

  • Choi, Yun Seok;Noh, Hui Seong;Choi, Cheon Kyu
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.12
    • /
    • pp.991-998
    • /
    • 2022
  • The purpose of this study is to develop GPU (Graphics Processing Unit) acceleration technique for 2-dimensional model and to assess the effectiveness for high resolution flood simulation in wide area In this study, GPU acceleration technique was implemented in the G2D (Grid based 2-Dimensional land surface flood model) model, using implicit scheme and uniform square grid, by using CUDA. The technique was applied to flood simulation in Jinju-si. The spatial resolution of the simulation domain is 10 m × 10 m, and the number of cells to calculate is 5,090,611. Flood period by typhoon Mitag, December 2019, was simulated. Rainfall radar data was applied to source term and measured discharge of Namgang-Dam (Ilryu-moon) and measured stream flow of Jinju-si (Oksan-gyo) were applied to boundary conditions. From this study, 2-dimensional flood model could be implemented to reproduce the measured water level in Nam-gang (Riv.). The results of GPU acceleration technique showed more faster flood simulation than the serial and parallel simulation using CPU (Central Processing Unit). This study can contribute to the study of developing GPU acceleration technique for 2-dimensional flood model using implicit scheme and simulating land surface flood in wide area.