• Title/Summary/Keyword: RIA

Search Result 391, Processing Time 0.023 seconds

How Destination Image Factors Affect Domestic Tourists Revisit Intention to Ba Ria-Vung Tau Province, Vietnam

  • GIAO, Ha Nam Khanh;NGAN, Nguyen Thi Kim;PHUC, Nguyen Pham Hanh;TUAN, Huynh Quoc;HONG, Ha Kim;ANH, Huynh Diep Tram;NHU, Duong Thi Huynh;LAN, NgoThi
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.7 no.6
    • /
    • pp.209-220
    • /
    • 2020
  • This research examines the affect of destination image factors on revisit intention of domestic tourists at Ba Ria Vung-Tau (BRVT), by questioning directly 510 domestic tourists. The convenient sampling method is used in dividing the crowds into four groups; the four main surveyed areas in BRVT are: Vung Tau, Long Hai-Phuoc Hai, Xuyen Moc and Con Dao. A combination of qualitative and quantitative methodologies were utilized.A focus group of 10 domestic tourists wasset up to review and explore the variousfactors as well as the conceptual model. An in-depth interview with 12 participants was developed to fine-tune measurement items. The questionnaire applied a 5-point Likert scale. Checking the reliability by Cronbach's Alpha, exploratory factor analyzing and linear multiple regression were used with the SPSS program. The results show that there are eight main destination image factors affecting domestic tourists revisit intention to BRVT using linear regression and arranged by decreasing importance: Infrastructure, Variety Seeking, Accessibility, Local food, Atmosphere, Environment, Price Value, Leisure and Entertainment. From that, the research offers some suggestions and policy recommendations for the tourism business and provincial policy-makers to identify the main issues and develop better customer services to increase domestic tourists'revisit intention.

An Implementation of Mobile Medical Reservation System using Geographic Information Service (지리정보 서비스를 이용한 모바일 진료예약 시스템의 구현)

  • Rho, Kyung-Taeg;Kim, Young-Hoon
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.10 no.2
    • /
    • pp.173-178
    • /
    • 2010
  • Recently, Technical innovation has been implemented in a broad variety of industry fields to reach an ubiquitous society, with the object of popularizing u-Hospital, the mobile technology with no restriction to the place tends to be used positively in Health care fields. The existing mobile medical reservation system has the problem of not making good use of location information of users due to the interface based on text in the existing web pages. This paper proposes an mobile medical reservation system using geographic information service to solve the problems of current reservation system by using RIA(Rich Internet Application) technology applicable to Web 2.0 environment. Our proposed system also does the all required processes in a few page view, gets the differentiated service from the existing system by allowing efficient data exchange using XML, and expects the improvement of user friendliness by flexible user interface.

Studies on the Rapid and Competitive Enzyme-linked Immunosorbent Assay for the Detection of Thyroxine (T$_4$) in Human Sera (경쟁적 효소면역측정법을 이용한 환자 혈청 내 Thyroxine (T$_4$)의 검출)

  • Sang-Wook Park;Jong-Bae Kim
    • Biomedical Science Letters
    • /
    • v.5 no.1
    • /
    • pp.11-15
    • /
    • 1999
  • Thyroxine (3,5,3',5'-L-tetraiodothyronine; T$_4$) is the most commonly measured thyroid hermono for the diagnosis of various thyroid disorders. Although radioimmunoassay (RIA) is still considered as the reference technique for the measurement of T$_4$, it is generally regarded that RIA has its primary disadventages in handling the wastes and controling the human and material resources. Therefore, establishment of enzyme-linked immunosorbent assay (ELISA) has of great significance. To verify the usefulness of our enzyme immunoassay, we have obtained the standard dose response curve of T$_4$ in patient's sera which is inversely proportional to the amount of herseradish peroxidase (HRP) conjugated monoclonal antibody of T$_4$ bound to the wells. The correlation coefficient (r) between the ELISA and chemiluminescent assay was 0.444 (n=38). Thus we have investigated the establishment of rapid and sensitive competitive ELISA assay method for detection of T$_4$ in patient's sera.

  • PDF

Implementation of an Expert System for COTS Fault Diagnosis (COTS 고장진단을 위한 전문가 시스템 구현)

  • Kim, A-Ram;Roh, Jin-Song;Rhee, Sang-Yong
    • Journal of Digital Convergence
    • /
    • v.11 no.1
    • /
    • pp.275-281
    • /
    • 2013
  • This space is for the of your study in English. If simple menu item changes or the addition of check items are necessary on GUI menu of existing test equipments for military facilities that are programmed by using RAD tools such as Visual C++, they should go through complex steps, such as numerous conducting steps, coding, flash design modification, recompiling and distribution. It is cumbersome process and waste much time. Also, on implementing them, it was worried about leaking secrets because a number of military security considerations were included. To solve such as the above problem, we proposed commercial RIA technologies and a COTS fault diagnostic knowledge-based system that implemented by the XML data design technique in this research. The proposed approach solves the problem of existing methods, reduced inspection time, and improved performance, usability, and maintainability.

Ultrasensitive Enzymeimmunoassay for Testosterone in Human Saliva (사람 타액내 Testosterone의 초감도 효소면역측정법)

  • 윤용달;전은현;이창주;도병록;이준영
    • Development and Reproduction
    • /
    • v.4 no.1
    • /
    • pp.115-123
    • /
    • 2000
  • A few enzymeimmunoassay (EfA) for testosterone (T) have been reported but was not suitable for all biological samples. The present study was designed to develop a rapid, ultrasensitive EIA and to apply this technique for study the physiological changes of T in biological samples. Saliva samples were collected at 06:00~09:00 hour during one menstrual cycle from 18 normally menstruating women and on 09:00~10:00 hour from 20 normal men. The present study shows an established EIA for testosterone, using horseradish peroxidase (HRP), which was covalently bonded to testosterone-3-carboxymethyloxime (T-3-CMO). One batch of T-antisera was also covalently linked to microcrystalline cellulose particles by a mixed anhydride method in order to facilitate separation of bound and free steroids. The established EIA was validated in terms of sensitivity, accuracy, specificity, precisions etc., comparing with conventional radioimmunoassay. The sensitivity of the established EIA was less than 25 pg/tube. The correlation coefficients between the expected T-values and observed T-values measured by EIA or RIA were r=0.985 and r=0.941 respectively. The cross reactivity of antiserum in EIA was a little higher than that of RIA, especially by 5 ${\alpha}$-DHT. The intra- and inter-assay precisions of the present EIA were similar to those of RIA. The present study also demonstrates that the normal T-values in saliva of Korean male & female samples are 265.65${\pm}$15.80 pmol/l and 109.74${\pm}$ 12.01 pmol/l, respectively. The present EIA seems to be established and suitable for use in the endocrinological studies. The advantages of this EIA system also might make the present T-EIA an ideal procedure for use in a routine assay of ordinary laboratory with a conventional spectrophotometer.

  • PDF

Evaluation of Reliability about Short TAT (Turn-Around Time) of Domestic Automation Equipment (Gamma Pro) (국산 자동화 장비(Gamma Pro)의 결과보고시간 단축에 대한 유용성 평가)

  • Oh, Yun-Jeong;Kim, Ji-Young;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.197-202
    • /
    • 2010
  • Purpose: Recently, many hospitals have been tried to increase the satisfaction of the outpatients through blood-gathering, exam, result notice and process in a day. Each laboratory has been used the automatic equipment for the rapid requests of the result notice and the increase of the reliability and efficiency. Current automatic equipments that have been limited short TAT(Turn-Around Time)because of the restricted batch lists and 1 tip-5 detectors. The Gamma Pro which is made in Korea to improve the shortcomings of existing automation equipment, complemented with capacity to perform a wide range of domestic automation equipment. In this study, we evaluated the usefulness and reliability of short TAT by comparing Gamma Pro with current automatic equipment. Materials and Methods: We studied the correlation between Gamma Pro and RIA-mat 280 using the respective 100 specimens of low or high density to the patients who were requested the thyroid hormone test (Total T3, TSH and Free T4) in Samsung Medical Center Sep. 2009. To evaluate the split-level Gamma Pro, First, we measured accuracy and carry over on the tips. Second, the condition of optimal incubation was measured by the RPM (Revolution Per Minute) and revolution axis diameter on the incubator. For the analysis for the speed of the specimen-processing, TAT was investigated with the results in a certain time. Result: The correlation coefficients (R2) between the Gamma Pro and RIA-mat 280 showed a good correlation as T3 (0.98), TSH (0.99), FT4 (0.92). The coefficient of variation (C.V) and accuracy was 0.38 % and 98.3 % at tip 1 and 0.39 % and 98.6 % at tip 2. Carry over showed 0.80 % and 1.04% at tip 1 and tip 2, respectively. These results indicate that tips had no effect on carry over contamination. At the incubator condition, we found that the optimal condition was 1.0mm of diameter at 600RPM in 1.0mm and 1.5mm of at 500RPM or 1.0mm and 1.5 mm of diameter at 600 RPM. the Gamma Pro showed that the number of exam times were increased as maximum 20 times/day comparing to 6 times/day by current automatic equipment. These results also led to the short TAT from 4.20 hour to 2.19 hours in whole processing. Conclusion: The correlation of between the Gamma Pro and RIA-mat 280 was good and has not carry over contamination in tips. The domestic automation equipment (Gamma Pro) decreases the TAT in whole test comparing to RIA-280. These results demonstrate that Gamma Pro has a good efficiency, reliability and practical usefulness, which may contribute to the excellent skill to process the large scale specimens.

  • PDF

The Study of RIA Development Direction using Suggestion System (제안제도를 활용한 RIA 발전 방향에 관한 연구)

  • Shin, Young-Kyun;Chun, Jun-Hong;Kim, Yeon-Ok;Lee, Seon-Ho;Kim, Seong-Ho;Yoo, Seon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.106-112
    • /
    • 2011
  • Purpose: Until now, the process was improved by the needs of experimenters personally. But recently, suggestion system in hospital has been activated in various ways. So the department of nuclear medicine laboratory is also aware of the need of operation improvement using suggestion system. It is intend to assist in the development by sharing excellent suggestion cases with other hospitals. Material & Method: A total of 124 suggestion cases from January 2007 to March 2010 were analyzed. Suggestion cases were divided into customer satisfaction, cost reduction, improved testing methods, equipment, environmental improvement, and computational system. Result: Suggestion cases of environmental improvement and computational system were accounted for 26.6% as 33 cases, respectively. Suggestion for customer satisfaction is 25.8% as 32 in a total of 124 cases. Conclusion: Activation of the awareness of operation improvement is induced by suggestion system. By securing system of operation improvement, employees' ideas can lead to the production and systematization. Furthermore, it enhances hospital competitiveness and promotes the development of the hospital.

  • PDF

An Improved Reliability-Based Design Optimization using Moving Least Squares Approximation (이동최소자승근사법을 이용한 개선된 신뢰도 기반 최적설계)

  • Kang, Soo-Chang;Koh, Hyun-Moo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.1A
    • /
    • pp.45-52
    • /
    • 2009
  • In conventional structural design, deterministic optimization which satisfies codified constraints is performed to ensure safety and maximize economical efficiency. However, uncertainties are inevitable due to the stochastic nature of structural materials and applied loads. Thus, deterministic optimization without considering these uncertainties could lead to unreliable design. Recently, there has been much research in reliability-based design optimization (RBDO) taking into consideration both the reliability and optimization. RBDO involves the evaluation of probabilistic constraint that can be estimated using the RIA (Reliability Index Approach) and the PMA(Performance Measure Approach). It is generally known that PMA is more stable and efficient than RIA. Despite the significant advancement in PMA, RBDO still requires large computation time for large-scale applications. In this paper, A new reliability-based design optimization (RBDO) method is presented to achieve the more stable and efficient algorithm. The idea of the new method is to integrate a response surface method (RSM) with PMA. For the approximation of a limit state equation, the moving least squares (MLS) method is used. Through a mathematical example and ten-bar truss problem, the proposed method shows better convergence and efficiency than other approaches.