• Title/Summary/Keyword: RGP렌즈 제조

Search Result 10, Processing Time 0.046 seconds

The Relationship between Lens Properties and the Lens Wearer's Factors in RGP Lens Manufacturing (RGP렌즈 제조 시 렌즈 물성과 렌즈 착용자 요인과의 관계)

  • Park, Mijung;Park, Ha Young;Park, Jung Ju;Kong, Heejung;Cha, Young Hwa;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.1
    • /
    • pp.27-35
    • /
    • 2013
  • Purpose: The present study was conducted to investigate the changes in the physical properties of RGP lenses induced by the polishing during the process of RGP lens manufacturing, and further evaluate the differences in the actual wearer's comfort and the tear film break-up time caused by these changes. Methods: RGP lenses (fluorosilicone acrylate material) were divided into 4 groups by the different lens-polishing time like 0, 25, 50 and 100 seconds and the thickness, the surface roughness and the wetting angle of those lenses were compared. Furthermore, the comfortability of the lens wear was surveyed after applying these lenses on the subject's eyes with normal tear volume and the non-invasive tear break-up time of the wearers was measured. Results: The central thickness of 4 RGP lenses made of different lens-polishing time was not significantly different however, the lens surface was changed smoother after polishing to be confirmed by scanning electron microscopy. The wetting angle of the RGP lens significantly decreased in accordance with the increase of polishing time. Thus, the difference of approximately $16^{\circ}$ between 0 second and 100 seconds-polishing was statistically significant. The actual wearing feeling of RGP lens was tended to improve in accordance with the increase of the lens wettability however, it was not proportional improvement. The non-invasive tear break-up time of the lens wearers showed different aspect compared with the changes in lens wettability and the actual feeling of RGP lens wear. Conclusions: In this study, better lens wettability, thinner lens thickness, and/or improved lens surface induced by physical stimuli in the process of RGP lens manufacturing was not well-correlated with the increase of actual subjective/objective satisfaction in RGP lens wear. Thus, the consideration of physical properties of the lens as well as the lens wearers' physiological factors in the process of RGP lens manufacturing may be suggested.

Changes in Subjective Symptom, Tear Film Stabilization and Blinking Rates when Wearing RGP Lenses with Different Polishing Conditions for Certain Period of Time (연마상태가 다른 RGP렌즈의 일정기간 착용 시 렌즈착용자의 자각적 증상, 눈물막 안정 및 순목횟수 변화)

  • Park, Mijung;Kim, Hyo Gyum;Bae, Jun Seob;Park, Jung Ju;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.1
    • /
    • pp.31-42
    • /
    • 2014
  • Purpose: The present study was conducted to investigate the effect of the physical properties of RGP lens induced by lens polishing on the actual wearer's subjective comfort, the tear film break-up time and the blinking rate as a follow-up study that revealed the relationship between the lens physical properties during lens manufacturing and lens wearer's factors. Methods: RGP lenses made from the three different polishing conditions (25, 50 and 100 seconds) were applied on 28 eyes of 17 subjects, aged 20 to 29 years, without any known disease and surgical history in the eyes. While the subjects were asked to wear the RGP lenses longer than a week, the questionnaire for the comfortability was administered everyday. Subjective and objective tear break-up time and blinking rate of the wearers were further measured. Results: The wearer's subjective comfortability showed some difference in the type of discomfort and satisfaction score according to the polishing status when wearing RGP lenses made from different polishing conditions longer than a week, and a bigger difference in satisfaction score induced by polishing condition was especially shown in experienced RGP lens wearer rather than un-experienced wearer. In the case of RGP lens wearer compared with the ones without the wearing experience, as the wearing time increased subjective and objective tear break-up time were increased and the blinking rate was decreased. However, subjective and objective tear break-up time were tended to decrease with even longer wearing time when wearing the RGP lens made from the polishment for 100 seconds. Conclusions: These results confirmed that the optimization of physical properties of the lens may not give the same effect on the wearer's subjective and objective symptoms and other factors when actual wearing. From the results, it can suggest that the success rate of RGP lens wear may be changed by physiological factors such as the stabilization of wearer's tear film, comfortability and lens wearing experience when wearing RGP lens based on 'The manufacturing standard for soft contact lens/hard contact lens' provided by Korea Food and Drug Administration.

A Relationship between Corneal Eccentricity and Stable Centration of RGP Lens on Cornea (각막 이심률과 RGP 렌즈의 중심안정위치와의 상관관계)

  • Park, Eun Hye;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.4
    • /
    • pp.373-380
    • /
    • 2012
  • Purpose: The present study was performed to investigate a relationship between the stable centrations of spherical RGP lens and aspherical RGP lens on cornea and corneal eccentricity. Methods: Two RGP lenses with different designs were fitted in alignment, steep or flat on total 84 eyes having corneal eccentricity of 0.28~0.78. The stable centration of lenses on cornea was analyzed by taking photographs with a high-speed digital camera. Results: The stable centrations of spherical and aspherical RGP lenses in horizontal direction were decentrated to temporal side. More centration to median side was shown when corneal eccentricity was larger. The difference between the stable centrations of spherical and aspheric RGP lenses according to corneal eccentricity was bigger when the fitting state was flatter. The difference in the stable centrations of aspherical RGP lens was smaller than that of spherical RGP lens regardless of fitting status. The stable centrations of spherical and aspherical RGP lenses in vertical direction were located below corneal apex regardless of fitting status however, there was no significant difference analyzed by the variation of corneal eccentricity. However, there were many cases that RGP lenses were in upper eyelid with increasing corneal eccentricity. Conclusions: The consideration of corneal eccentricity is required for RGP lens fitting and manufacturing aspherical RGP lens since the stable centration of spherical RGP lens as well as aspherical RPG lens' centration was changed depending on corneal eccentricity.

Comparison of preference and Empirical Fit Success Rates for Spheric and Aspheric RGP Lenses (구면 및 비구면 디자인 RGP 콘택트렌즈의 선호도와 경험적 피팅 성공률 비교)

  • Kim, Jai-Min;Kim, Soo-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.2
    • /
    • pp.9-16
    • /
    • 2008
  • To assess the preference and efficacy of empirical fitting methods with spheric and aspheric RGP lenses. Methods: Healthy 37 subjects were fitted with spheric design (diameter 9.3 mm) on right eye and aspheric design (dia 9.6 mm) on the left eye. Base curves which were fitted empirically (using on-K, Kavg-0.50D (or 1.00D) and manufacturer's recommended fitting guide) were compared with another base curve which obtained the best diagnostic fit with spheric and aspheric RGP lenses. The preference and fitting type (lid attachment or interpalpebral) for two design lenses were investigated 2 weeks after fitting RGP lenses. Results: Of 33 successful RGP lens-wearing subjects, 76% preferred spheric design compared with 24% of aspheric RGP lens wearers. Sixty seven percent were fitted with lid-attachment in spheric lenses, whereas 64% were fitted with lid-attachment in aspheric lenses. The acceptable fit success rates within ${\pm}$0.50D of base curves were 97% for the on-K fit, 100% for the Kavg-0.50D fit and 100% of the manufacturer's guide fit compared with the diagnostic fit in spheric design, whereas 91%, 79% and 94% reported on-K, Kavg-1.00D and manufacturer's guide, respectively, in aspheric design. Conclusions: Although aspheric RGP lenses are more popular in the Korean market, it is still preferable to fit subjects with spheric RGP lenses. Empirical fitting may be best accomplished with the spheric lenses using Kavg-0.50D fit and the manufacturer's fitting guide, whereas aspheric RGP lens designs are unacceptable lens fit based on empirical fitting.

  • PDF

The Study of the Ultrastructure on the Rigid Gas Permeable Contact Lenses (Rigid Gas Permeable Contact Lenses의 미세구조에 대한 연구)

  • Kim, Douk-Hoon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.3 no.1
    • /
    • pp.259-262
    • /
    • 1998
  • The Anterior surface and posterior surface of rigid gas permeable(RGP) contact lenses has been studied by scanning electron microscopy. Results point out that the ultrastructure of contact lenses surface was some different on the anterior and posterior surface of RGP. The Quantitative study of surface roughness suggest that the anterior surface was more smooth than the posterior surface. These results suggest that the materials characters appeared the contact lens surface. The morphology of the anterior and posterior surface have different, Maybe, these result have a manufacture processing of the contact lenses. But some surface appeared a foreign body particles.

  • PDF

Denaturation and Inactivation of Antioxidative Enzymes due to Repeated Exposure to UV-B and Inhibitory Effect of RGP Lens (UV-B 반복노출에 따른 항산화효소의 변성 및 활성저하와 RGP렌즈의 차단효과)

  • Byun, Hyun Young;Lee, Eun Jung;Oh, Dae Hwan;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.2
    • /
    • pp.237-246
    • /
    • 2015
  • Purpose: The present study was conducted to reveal the correlation of structural denaturation and decrease of enzyme activity when the antioxidative enzymes, superoxide dismutase (SOD) and catalase (CAT) were repeatedly exposed to UV-B, and further investigate whether the denaturation and inactivation of those enzymes can be effectively blocked by using UV-inhibitory RGP lens. Methods: Each enzyme solution was prepared from the standardized SOD and CAT, and repeatedly exposed to UV-B of 312 nm for 30 minutes, 1 hour and 2 hours a day over 1, 2, 3, 4 and 5 days. Structural denaturation of SOD and CAT induced by repeat UV-B irradiation was confirmed by the electrophoretic analysis, and their enzyme activity was determined by the colorimetric assay using the proper assay kit. At that time, the change in structure and activity of the antioxidant enzymes directly exposed to UV-B was compared to the case that UV-B was blocked by UV-inhibitory RGP lens. Results: SOD exposed repeatedly to UV-B showed the polymerization pattern in the electrophoretic analysis when it repeatedly exposed for 30 min a day, however, the change of its activity was less than 10%. On the other hand, CAT repeatedly exposed to UV-B reduced size and density of the electrophoretic band which indicated a structure denaturation, and its activity was significantly decreased. In the case that the repeat exposure time was longer, CAT activity was completely lost even though some enzyme band occurred in the electrphoretic analysis. In addition, the degeneration of CAT due to UV-B irradiation was inhibited to some extent by using RGP lens with a UV-B blocking of 63.7%, however, it was not completely inhibited. Conclusions: From these results, it was revealed that the structural denaturation of antioxidative enzymes was not perfectly correlated with the reduction in enzyme activity according to the type of enzyme. It is recommended to minimize the exposure time to UV when wearing contact lens, or wear the contact lenses having UV blocking rate of the FDA Class I blocker or the sunglasses having equivalent UV-blocking rate for reducing the damage of antioxidative enzymes induced by UV.

RGP lens 다목적 용액의 습윤성에 관한 비교 연구

  • Park, Hyeon-Ju;Kim, Jae-Min;Lee, Gi-Yeong
    • 한국생물공학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.428-433
    • /
    • 2003
  • We measured the effect of wettability of six MPSs for RGP(rigid gas permeable) lens. The used MPSs(multipurpose solutions) were OPTI-SOAK(ALCON), SOLO care hard(CIBA Vision), Total care(ALLERGAN), Simplicity(BOSTON), Wetting and Soaking Sol.(Bausch & Lomb) and Aquas-multi(Saehan). These MPSs keeps hydrophilic property of lens surface and increase the effect of cleaning or increase the effect of preservative effect. To compare with the effect of wettability we followed the way of contact angle measurement which was general way to measure wettability and compared lens which was conducted by each MPS made by different companies. As a control, 0.9% NaCl solution and artificial tears were used. The degree of the effect of wettability was decided by contact angle. It is hydrophilic property nearby $0^{\circ}$ of contact angle and it is closed by hydrophobic property as it increases. The results showed that every lens was nearby hydrophilic property within $25\;^{\circ}-36\;^{\circ}$. Also, it was differed by various factors. The surface tension showed various differences between 19.8 and 31.3 mN/m. In the viscosity, MPSs represented the highest viscosity between $4^{\circ}C$ and $20^{\circ}C$. It was much higher than compared with the viscosity of soft lens MPS. This experiment could be used to grasping the interaction between solutions used to MPS and the natural endowments of lens and to considering the relations of different factors effecting the wettability.

  • PDF

The Comparative Study on the wettability of the RGP lens multi-purpose solutions(MPSs) (RGP lens 다목적용액의 습윤성에 관한 비교 연구)

  • Park, Hyun-Ju;Goe, Eun-Kyung;Seo, Eun-Sun;Kim, Jai-Min;Lee, Ki-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.8 no.2
    • /
    • pp.119-127
    • /
    • 2003
  • We measured the effect of wettability of six MPSs for RGP lens. The used MPSs(multipurpose solutions) were OPTI-SOAK(ALCON), SOLO care hard(CIBA Vision), Total care(ALLERGAN), Simplicity(BOSTON). Wetting and Soaking Sol.(Bausch & Lomb) and Aquas-multi(Saehan). These MPSs keeps hydrophilic property of lens surface and increase the effect of cleaning or increase the effect of preservative effect. To compare with the effect of wettability we followed the way of contact angle measurement which was general way to measure wettability and compared lens which was conducted by each MPS made by different companies. As a control, 0.9% NaCl solution and artificial tears were used. The degree of the effect of wettability was decided by contact angle. It is hydrophilic property nearby $0^{\circ}$ of contact angle and it is closed by hydrophobic property as it increases. To compare with the effect of wettability we followed the way of contact angle measurement which was general way to measure wettability and compared lens which was conducted by each MPS made by different companies. As a control, 0.9% NaCl solution and artificial tears were used. The degree of the effect of wettability was decided by contact angle. It is hydrophilic property nearby $0^{\circ}$ of contact angle and it is closed by hydrophobic property as it increases. The results showed that every lens was nearby hydrophilic property within $25^{\circ}{\sim}36^{\circ}$. Also, it was differed by various factors. The surface tension showed various differences between 19.8 and 31.3(mN/m). In the viscosity, MPSs represented the highest viscosity between $4^{\circ}C$ and $20^{\circ}C$. It was much higher than compared with the viscosity of soft lens MPS. This experiment could be used to grasping the interaction between solutions used to MPS and the natural endowments of lens and to considering the relations of different factors effecting the wettability.

  • PDF

Comparison of Corneal Asphericity with Measuring Range (측정 범위에 따른 각막비구면계수의 비교)

  • Jeon, In-Chul;Jeong, Woo-Jae;Kang, Ji-Hun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.4
    • /
    • pp.469-476
    • /
    • 2012
  • Purpose: The purpose of this study is to investigate the changes of asphericity according to diameter and direction of the cornea. Methods: The changes of asphericity according to diameter and direction of cornea is measured by using Pentacam(Oculus Co., Germany), as targeting 57 adults (average $27.0{\pm}4.8$, 20 men, 37 women) without any ophthalmic diseases, which may be effective in eyesight, and refractive surgery. Results: As diameter increases in every direction based on the corneal vertex, asphericity has attentively increased (p<0.05), and the size of asphericity in each direction from every measured diameter showed as superior > nasal > inferior > temporal. In group comparison by nearsightness and astigmatism level, asphericity measured high when nearsightness and astigmatism levels were higher, and this appears to be statistically attentive.(p<0.05). Conclusions: Asphericity of cornea significantly increased according to increase of diameter of cornea, and as measured figure or increased quantity appeared differently in all directions based on corneal vertex, so it helps to understand shape of cornea, and considered that is the part to be considered during manufacturing and fitting of RGP lenses.

The Analysis of Corneal Patterns in Korean 20s by Corneal Topography and Corneal Radii by Astigmatic Degree (각막지형도를 이용한 20대의 각막형상 및 난시도에 따른 각막곡률반경의 분석)

  • Kim, So Ra;Gil, Ji-Yeon;Park, Chang Won;Kim, Ji Hye;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.3
    • /
    • pp.273-281
    • /
    • 2011
  • Purpose: In order to provide the fundamental information for the design development of RGP lenses and its clinical prescription, the corneal types of Korean twenties were analyzed according to corneal shapes, astigmatic degree, and the certain distance from the corneal apex. Methods: Corneal types of total 252 eyes in 20s were firstly classified, then their corneal radii from the certain distance from the corneal apex were measured by corneal topography and further analyzed based on the astigmatic degree. Results: Korean 20s' corneal types were classified as 14.3%(36 eyes) of round, 31.3%(79 eyes) of oval, 28.6%(72 eyes) of symmetric bow tie, 17.5%(44 eyes) of asymmetric bow tie, 8.3%(21 eyes) of irregular shapes. The round and oval typed corneas had mild astigmatic degree whereas the higher astigmatic degree in symmetric and asymmetric bow tie typed corneas were shown. The relative corneal radii of round and oval typed corneas at each distance from corneal apex were shown to consistently increase regardless of astigmatic degrees when they measured at certain distances from the corneal apex. However, the relative corneal radii of symmetric and asymmetric bow tie typed corneas within 1.0-1.5mm from the corneal apex were decreased, which showed steeper slope than it within 1.0 mm and somewhat different based on astigmatic degrees. Bigger change of corneal radii outer 3.5 mm from the corneal apex in symmetric bow tie typed corneas with astigmatism of 1.50-2.00 D and 2.25-2.75 D appeared. Conclusions: The consideration of radial change from the central cornea to peripheral cornea is necessary for manufacturing RGP lens and its prescription since they showed different change in corneal radii by corneal patterns and astigmatic degrees.