• 제목/요약/키워드: RF Heating

검색결과 142건 처리시간 0.028초

다양한 MRI 시스템에서 사용가능한 의료용 리드선 (A New Medical Lead for Various MRI Systems)

  • 김홍준;유형석
    • 전기학회논문지
    • /
    • 제64권3호
    • /
    • pp.429-432
    • /
    • 2015
  • Radio Frequency (RF) coils in Magnetic Resonance Imaging (MRI) systems interact with a patient's tissues, resulting in the absorption of RF energy by the tissues. The presence of an electrically conducting medical implant may concentrate the RF energy and causes tissue heating near the implant devices. Here we present a novel design for a medical lead to reduce this undesired heating. Specific Absorption Rate (SAR), an indicator of heating, was calculated. Remcom XFdtd software was used to calculate the peak SAR distribution (1g and 10 g) in a realistic model of the human body. The model contained a medical lead that was exposed to RF magnetic fields at 64 MHz (1.5 T MRI), 128 MHz (3 T MRI) and 300 MHz (7 T MRI) using a model of an MR birdcage body coil. Our results demonstrate that, our proposed design of adding nails to the medical lead can significantly reduce the SAR for different MRI systems.

Development of Liquid Stub and Phase Shifter

  • Wang, Son-Jong;Yoon, Jae-Sung;Hong, Bong-Guen
    • Nuclear Engineering and Technology
    • /
    • 제33권2호
    • /
    • pp.201-208
    • /
    • 2001
  • The high power RF transmission line components are required for transmitting MW level RF power continuously in RF heating and current drive system which heat the plasma and produce plasma current in fusion reactor The liquid stub and phase shifter is proposed as the superior to the conventional stub and phase shifter. Experimental results show that they are reliable and easy to operate compared to the conventional stub and phase shifter. There is no distortion of reflected power during the raising of the liquid level. RF breakdown voltage is over 40kV. Temperature increment of the liquid is expected not to be severe. These results verify that the liquid stub and phase shifter can be used reliably in the high power continuous RF facilities.

  • PDF

Effects of heat-moisture treatment of rice flour on the properties in tofu

  • An, Shu;Lee, Kwang Yeon;Lee, Hyeon Gyu
    • 한국식품과학회지
    • /
    • 제53권1호
    • /
    • pp.92-98
    • /
    • 2021
  • The effects of heat-moisture treatment (HMT) on rice flour (RF) have been investigated for possibility of texture modifier in protein-based foods matrix, tofu. The optimum condition for preparation of tofu with maximum textural parameters was investigated by using response surface methodology (RSM). Rice flour was subjected to moisture content (10-30%) and heating temperature (100-140℃). Based on the response surface and superimposed plots, the optimized conditions of hydrothermally treated rice flour was as followed: moisture content, 22%; temperature, 130℃, which showed lower swelling power as compared to native RF and became more stable during continuous heating and agitation than native one. Tofu, prepared with HMT-RF, showed a denser network structure than that with RF, thereby inducing an increase in textural parameters. From the above results, the addition of HMT-RF could preserve the quality of tofu and be useful for developing an acceptable protein-based food product.

저자장 자기공명영상 시스템 내에서 초상자성 나노입자 온열치료를 위한 발열 평가 (Feasibility Study on Magnetic Nanoparticle Hyperthermia in Low Field MRI)

  • 김기수;조민형;이수열
    • 대한의용생체공학회:의공학회지
    • /
    • 제35권4호
    • /
    • pp.105-110
    • /
    • 2014
  • For the combination of MRI and magnetic particle hyperthermia(MPH), we investigated the relative heating efficiency with respect to the strength of the static magnetic field under which the magnetic nanoparticles are to be heated by RF magnetic field. We performed nanoparticle heating experiments at the fringe field of 3T MRI magnet with applying the RF magnetic field perpendicularly to the static magnetic field. The static field strengths were 0T, 0.1T, 0.2T, and 0.3T. To prevent the coil heat from conducting to the nanoparticle suspension, we cooled the heating solenoid coil with temperature-controlled water with applying heat insulators between the solenoid coil and the nanoparticle container. We observed significant decrease of heat generation, up to 6% at 0.3T(100% at 0T), due to the magnetic saturation of the nanoparticles of 15 nm diameter under the static field. We think MPH is still feasible at low magnetic field lower than 0.3T if stronger RF magnetic field generation is permitted.

온열료법을 이용한 고주파 및 마이크로웨이브 암치료기에 관한 연구 (A Study on the RF and Microwave Hyperthermia System for Cancer Therapy)

  • 유재병;박덕규;양성화;박민용;추성실;이상배
    • 대한전자공학회논문지
    • /
    • 제24권3호
    • /
    • pp.486-492
    • /
    • 1987
  • This study is an attempt to review the theories about the RF and microwave hyperthermia and to get the practical implementation of hyperthermia system on the basic clinical experiments with agar phantoms and four patients. The frequencies of RF power are 8 MHz and 16 MHz, which are effective for the heating of deep-seated and superficial tumors, and microwave is 2.45 GHz, also suitable for the heating of superficial tumors. Even if the long-term effect of clinical applications were not investigated for human living body, it was observee that the RF and microwave hyperthermias are effective for many kinds of cancers in the fixed frequency ranges.

  • PDF

Discharge Characteristics of Large-Area High-Power RF Ion Source for Neutral Beam Injector on Fusion Devices

  • Chang, Doo-Hee;Park, Min;Jeong, Seung Ho;Kim, Tae-Seong;Lee, Kwang Won;In, Sang Ryul
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.241.1-241.1
    • /
    • 2014
  • The large-area high-power radio-frequency (RF) driven ion sources based on the negative hydrogen (deuterium) ion beam extraction are the major components of neutral beam injection (NBI) systems in future large-scale fusion devices such as an ITER and DEMO. Positive hydrogen (deuterium) RF ion sources were the major components of the second NBI system on ASDEX-U tokamak. A test large-area high-power RF ion source (LAHP-RaFIS) has been developed for steady-state operation at the Korea Atomic Energy Research Institute (KAERI) to extract the positive ions, which can be used for the NBI heating and current drive systems in the present fusion devices, and to extract the negative ions for negative ion-based plasma heating and for future fusion devices such as a Fusion Neutron Source and Korea-DEMO. The test RF ion source consists of a driver region, including a helical antenna and a discharge chamber, and an expansion region. RF power can be transferred at up to 10 kW with a fixed frequency of 2 MHz through an optimized RF matching system. An actively water-cooled Faraday shield is located inside the driver region of the ion source for the stable and steady-state operations of RF discharge. The characteristics and uniformities of the plasma parameter in the RF ion source were measured at the lowest area of the expansion bucket using two RF-compensated electrostatic probes along the direction of the short- and long-dimensions of the expansion region. The plasma parameters in the expansion region were characterized by the variation of loaded RF power (voltage) and filling gas pressure.

  • PDF

심재성 암치료를 위한 RF hyperthermia system의 설계 및 제작 (Design and implementation of RF hyperthermia system for deep-seated cancer therapy.)

  • 유재형;박민용
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1985년도 춘계학술대회
    • /
    • pp.9-12
    • /
    • 1985
  • This paper covers the design and implementation process of RF hypertermia system for cancer therapy. Among many hyperthermic methods, RF capacitive heating method is discussed because it can heat the deep-seated tumors selectively. The RF power oscillator and its applicators were designed and implemented. And the experiments were performed with agar phantom and dog to prove that the system can heat any depth selectively. And the electrical safety and appropriateness of clinical application was proved through the human living-body test.

  • PDF

Development of Large-Area RF Ion Source for Neutral Beam Injector in Fusion Devices

  • Chang, Doo-Hee;Jeong, Seung Ho;Kim, Tae-Seong;Park, Min;Lee, Kwang Won;In, Sang Ryul
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제45회 하계 정기학술대회 초록집
    • /
    • pp.179.2-179.2
    • /
    • 2013
  • A large-area RF-driven ion source is being developed at Germany for the heating and current drive of ITER device. Negative hydrogen ion sources are major components of neutral beam injection (NBI) systems in future large-scale fusion experiments such as ITER and DEMO. The RF sources for the production of positive hydrogen ions have been successfully developed at IPP (Max-Planck-Institute for Plasma Physics), Garching, for the ASDEX-U and W7-AS neutral beam heating systems. Ion sources of the first NBI system (NBI-1) for the KSTAR tokamak have been developed successfully with a bucket plasma generator based on the filament arc discharge, which have contributed to achieve a good plasma performance such as 15 sec H-mode operation with an injection of 3.5 MW NB power. There is a development plan of RF ion source at the KAERI to extract the positive ions, which can be used for the second NBI system (NBI-2) of the KSTAR and to extract the negative ions for future fusion devices such as Fusion Neutron Source and Korea-DEMO. The development progresses of RF ion source at the KAERI are described in this presentation.

  • PDF

스컬용융법에 의한 루틸 단결정 성장메커니즘과 RE generator 조건에 관한 연구 (A study on the growth mechanism of rutile single crystal by skull melting method and conditions of RF generator)

  • 석정원;최종건
    • 한국결정성장학회지
    • /
    • 제15권5호
    • /
    • pp.175-181
    • /
    • 2005
  • 스컬용융법에 의해 루틸 단결정들을 성장시켰으며, 서로 다른 융액의 유지시간에 따른 ingot의 특성을 비교하였다. 스컬용융법은 교류전자기장(RF)에 의해 전기가 흐르는 융액의 직접유도가열에 근거하며, 가열은 RF 에너지의 흡수로 실행된다. $TiO_2$는 상온에서는 부도체이지만 온도가 올라갈수록 전기 전도성이 증가한다. 따라서, 초기 RF 유도가열을 위해 티타늄 금속 링(외경 : 6cm, 내경 : 4cm, 두께 : 0.2cm)을 $TiO_2$ 분말(아나타제상, CERAC, 3N)내부에 묻었다. 스컬용융법에 의한 산화물 용융에서 매우 중요한 것은 융점에서의 전기 저항 값, RF generator의 주파수 그리고 냉각도가니 크기이다. 본 연구에서는, $TiO_2$의 융점에서의 전기저항$(10^{-2}\~10^{-1}\;{\Omega}{\cdot}m)$은 알루미나$(10^{-1}\;{\Omega}{\cdot}m)$의 지르코니아$(10^{-3}\;{\Omega}{\cdot}m)$의 전기저항 데이터를 바탕으로 추정하였다. 냉각도가니의 내부직경은 11cm, 높이는 14cm였으며, 이것은 침투깊이$(0.36\~1.13cm)$와 RF generator 주파수를 고려하여 결정하였다

Development of RF Ion Source for Neutral Beam Injector in Fusion Devices

  • 장두희;박민;김선호;정승호
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.550-551
    • /
    • 2013
  • Large-area RF-driven ion source is being developed at Germany for the heating and current drive of ITER plasmas. Negative hydrogen (deuterium) ion sources are major components of neutral beam injection systems in future large-scale fusion experiments such as ITER and DEMO. RF ion sources for the production of positive hydrogen ions have been successfully developed at IPP (Max-Planck- Institute for Plasma Physics, Garching) for ASDEX-U and W7-AS neutral beam injection (NBI) systems. In recent, the first NBI system (NBI-1) has been developed successfully for the KSTAR. The first and second long-pulse ion sources (LPIS-1 and LPIS-2) of NBI-1 system consist of a magnetic bucket plasma generator with multi-pole cusp fields, filament heating structure, and a set of tetrode accelerators with circular apertures. There is a development plan of large-area RF ion source at KAERI to extract the positive ions, which can be used for the second NBI (NBI-2) system of KSTAR, and to extract the negative ions for future fusion devices such as ITER and K-DEMO. The large-area RF ion source consists of a driver region, including a helical antenna (6-turn copper tube with an outer diameter of 6 mm) and a discharge chamber (ceramic and/or quartz tubes with an inner diameter of 200 mm, a height of 150 mm, and a thickness of 8 mm), and an expansion region (magnetic bucket of prototype LPIS in the KAERI). RF power can be transferred up to 10 kW with a fixed frequency of 2 MHz through a matching circuit (auto- and manual-matching apparatus). Argon gas is commonly injected to the initial ignition of RF plasma discharge, and then hydrogen gas instead of argon gas is finally injected for the RF plasma sustainment. The uniformities of plasma density and electron temperature at the lowest area of expansion region (a distance of 300 mm from the driver region) are measured by using two electrostatic probes in the directions of short- and long-dimension of expansion region.

  • PDF