• Title/Summary/Keyword: RF Detector

Search Result 121, Processing Time 0.029 seconds

Capacitive Parameter Estimation of Passive Telemetry RF Sensor System Using RLS Algorithm (RLS 알고리즘을 이용한 원격 RF 센서 시스템의 정전용량 파라메타 추정)

  • Kim, Kyung-Yup;Lee, John-Tark
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.5
    • /
    • pp.858-865
    • /
    • 2008
  • In this paper, Capacitive Telemetry RF Sensor System using Recursive Least Square (RLS) algorithm was proposed. General Telemetry RF Sensor System means that it should be "wireless", "implantable" and "batterless". Conventional Telemetry RF Sensor System adopts Integrated Circuit type, but there are many defects like complexity of structure and the limitation of large power consumption in some cases. In order to overcome these disadvantages, Telemetry RF Sensor System based on inductive coupling principle was proposed in this paper. Proposed Telemetry RF Sensor System is very simple because it consists of R, L and C and measures the changes of environment like pressure and humidity in the type of capacitive value. This system adopted RLS algorithm for estimation of this capacitive parameter. For the purpose of applying RLS algorithm, proposed system was mathematically modelled with phasor method and was quasi-linearized. As two parameters such as phase and amplitude of output voltage for estimation were needed, Phase Difference Detector and Amplitude Detector were proposed respectively which were implemented using TMS320C2812 made by Texas Instrument. Finally, It is verified that the capacitance of proposed telemetry RF Sensor System using RLS algorithm can be estimated efficiently under noisy environment.

Development and characterization of a ultra-wide bandwidth video detector for the UHF partial discharge monitoring system (UHF 부분방전 감시 장치를 위한 초광대역 검출장치 개발 및 특성조사)

  • Park, Ki-Jun;Goo, Sun-Geun;Yoon, Jin-Yul
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1649-1651
    • /
    • 2002
  • Ultra-wide bandwidth (UWB) detection method has been widely used as a front end detection scheme for the ultra-high frequency (UHF) partial discharge (PD) monitoring systems. A broad-band video detector module was developed and characterized for the UHF UWB PD detection systems. The useable bandwidth of the module is more than 2 GHz and it is optimized for 50-ohm systems. The detection sensitivity and dynamic range of the module were characterized by using a known ns-width RF pulses of GHz range. The dynamic range is more than 6-decades and the module can detect pulsed RF signals down to 1 nW. The detector module can eliminate expensive equipment such as high speed oscilloscopes and radio frequency (RF) spectrum analyzers. Therefore, it enables one to use slow speed data acquisition systems for the PD monitoring at the UHF range. The detector module was used to detect real PDs of about <3 pC. The module converts the UWB PD signals into a low-bandwidth video signal with a high signal-to-noise ratio.

  • PDF

Cryocoolers for cooling of HTS RF Filter and IR detector (초전도필터 및 적외선검지기 냉각용 극저온냉동기)

  • 홍용주
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.11
    • /
    • pp.18-23
    • /
    • 2002
  • 고품질의 극저온 환경의 생성 및 유지는 고품질 대용량 정보통신, 의료진단, 초전도 및 고집적반도체 제조공정 등의 차세대 유망 산업 분야에서 필수적인 요소로 자리 잡고 있으며, cryopump, 민수용 및 군수용의 적외선 검지기 및 초전도 RF 필터의 효과적 냉각을 위해 보다 높은 신뢰성과 수명, 고효율의 극저온 냉동기에 대한 수요는 점차 증대될 것으로 기대된다. 스터링 냉동기 및 맥동관 냉동기는 짧은 역사에도 불구하고, 다양한 분야에서 기존의 한제 및 극저온 냉동기를 대치하여 활용될 수 있을 것으로 전망된다.

Design and Implementation of Broadband Power Detector for Six-port Direct Conversion Receiver (Six-port 직접 변환 수신을 위한 광대역 Power detector 설계 제작)

  • Lee, Yong-Ju;Kim, Yeong-Wan;Park, Dong-Cheol
    • Journal of Satellite, Information and Communications
    • /
    • v.1 no.1
    • /
    • pp.59-64
    • /
    • 2006
  • The broadband power detector for power amplitude envelope detection of the direct-conversion Six-port output signal was designed and implemented in this paper. The power detector should be linearly operated to produce the linear amplitude and phase signal for input RF signals in required broadband frequency range. The power detector should be designed under conditions of matching circuit with low VSWR, which protect unbalanced phase signal from reflection signal due to mismatch between the output port of a six-port and the input port of a power detector. The designed power detectors, which were implemented in L-band with 50 ohm matching and Ku-band with multiple LC matching circuits and isolator, respectively, were analyzed in viewpoints of the utilization as a power detector of direct conversion Six-port. The dynamic range of designed power detectors were also measured and rvaluated as a power detector of Six-port circuit.

  • PDF

Study on NMR Measurment of Flowing Water by a Separated Detector (분리형 감지기를 이용한 흐르는 물의 핵자기공명 측정연구)

  • ;;;;V. Ya. Shifrin
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.3
    • /
    • pp.165-170
    • /
    • 1995
  • NMR measurement has been studied for protons in pre-polarized flowing water by a separated detector working at high field far away from the measured field region where the transition of protons is occurred by the pertur-bation of RF energy. The conditions for NMR signal were optimized on the amplitude and frequency of modulation field, the RF field of detector, water speed, and RF field at the measured field region. The NMR signal with the full width of 320 nT at the half maximum in Lorentzian curve and with signal to noise ratio of 10.5 was measured in the range from a few ${\mu}T$ to mT, and its shape and amplitude were independent of the measured field intensity and its uniformity.

  • PDF

Design of n Miniaturized LTCC Power Detector for the Tx Power Control in Wireless Communication System (무선통신시스템 송신측 제어를 위한 초소형 LTCC 전력검출부의 설계)

  • Hwang, Mun-Su;Lim, Jong-Sik;Yang, Gyu-Ryeol;Ahn, Dal
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.3
    • /
    • pp.621-627
    • /
    • 2008
  • This paper presents a compact and miniaturized power detector utilizing low temperature co-fired ceramics(LTCC) technology for the application in wireless handset system to monitor the transmitting power at the frequency of 824-849MHz. The proposed power detector is composed of detector diode, lumped components for matching network, and LTCC stripline coupler based on LTCC substrate technology. A 20dB LTCC stripline direction coupler is designed and implemented with many bending section in order to reduce the practically occupied area for miniaturization. A zero bias schottky diode is adopted for detector design because of its high speed operation with minimized loss. The measured performances of fabricated detector agree well with the predicted results with a good linearity within the effective input RF power range.

Fabrication of Uncooled Pyroelectric Infrared Detector using Surface M Micromachining Technology (표면 마이크로 가공기술을 이용한 비냉각 초전형 적외선 검출소자 제작)

  • 장철영;고성용;이석헌;김동진;김진섭;이재신;이정희;한석룡;이용현
    • Proceedings of the IEEK Conference
    • /
    • 2000.06b
    • /
    • pp.115-118
    • /
    • 2000
  • Uncooled pyroelectric infrared detectors based on BST(B $a_{-x}$S $r_{x}$Ti $O_3$) thin films have been fabricated by RF magnetron sputtering and surface Micromachining technology. The detectors form BST thin film ferroelectric capacitors grown by RF magnetron sputtering on N/O/N(S $i_3$ $N_4$/ $SiO_2$/S $i_3$ $N_4$) membrane. The sputtered BST thin film exhibits highly c-axis oriented crystal structure that no poling treatment for sensing applications is required. This is an essential factor to increase the yield for realization of an infrared image sensor. surface-Micromachining technology is used to lower the thermal mass of the detector by giving maximum sensor efficiency Gold-black is evaporated on top of the sensing elements used the thermal evaporator. fabricated uncooled pyroelectric infrared detectors is highly output voltage at the low temperature(1$^{\circ}C$).).).

  • PDF

A Design of Non-Coherent CMOS IR-UWB Receiver (비동기식 CMOS IR-UWB 수신기의 설계 및 제작)

  • Ha, Min-Cheol;Park, Young-Jin;Eo, Yun-Seong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.9
    • /
    • pp.1045-1050
    • /
    • 2008
  • In this paper presents a CMOS RF receiver for IR-UWB wireless communications is presented. The impulse radio based UWB receiver adopts the non-coherent demodulation that simplifies the receiver architecture and reduces power consumption. The IR-UWB receiver consists of LNA, envelop detector, VGA, and comparator and the receiver including envelope detector, VGA, and comparator is fabricated on a single chip using $0.18{\mu}m$ CMOS technology. The measured sensitivity of IR-UWB receiver is down to -70 dBm and the BER $10^{-3}$, respectively at data rate 1 Mbps. The current consumption of IR-UWB receiver except external LNA is 5 mA at 1.8 V.

Design of Wireless Lock-in Amplifier using RF Transmission System (RF 통신을 이용한 무선 Lock-in Amplifier 제작)

  • Park, Hyun-Soo;Lee, Hyang-Beom
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2008.08a
    • /
    • pp.131-136
    • /
    • 2008
  • System을 통해 출력되는 신호를 측정할 때 정확한 측정을 방해하는 요소로 잡음이 있다. 이런 신호 측정의 방해 요소인 잡음을 제거 하는 방법 중의 하나로 Lock-in Amp(LIA)가 사용되고 있다. 본 논문에서는 잡음 신호의 제거를 위해 사용 하는 LIA를 제작 하고 특성을 파악 하였으며 RF통신을 이용하여 무선 형태로 제작 하였다. 현재 상용화된 LIA는 프로브를 통한 유선으로 측정신호의 입력을 받게 되지만 본 논문에서 제작된 LIA는 무선신호 형태로 입력 하게 된다. RF통신의 케리어 주파수는 447.9[MHz]로 Digital GMSK 변복조방식을 이용하였다. LIA의 제작은 Dual Phase Sensitive Detecter을 사용하였으며, 주요 구성 요소인 Phase Locked Loop, Phase Shifter, Phase Sensitive Detector, Low Pass Filter등의 구조와 특성을 조사하였다.

  • PDF

A Study on IR Spectrum Characteristics of $PbTiO_3$ Thin Film and Pyroelectric Detector Modeling. ($PbTiO_3$ 박막의 적외선 스펙트럼특성과 초전감지소자의 모델링에 관한 연구)

  • Kim, Sung-Min;Lee, Moon-Key;Kim, Bong-Ryul
    • Proceedings of the KIEE Conference
    • /
    • 1987.07a
    • /
    • pp.439-443
    • /
    • 1987
  • $PbTiO_3$ thin film is prepared by rf sputtering method to implement the pyroelectric infrared detector at room temperature. Annealing of $PbTiO_3$ thin film is done from $400^{\circ}C$ to $550^{\circ}C$ each for 2 hours in furnace. The spectral response to recrystallization process of $PbTiO_3$ thin film is measured by IR photospectro meter. Pyroelectric detector Modeling is studied for implementing device using electrical equivalent circuit model. It is found that $PbTiO_3$ thin film has two IR absorption band within $1000-400\;cm^{-1}$ (10um-25um) and it's spectral response is improved as annealing temperature increase. As a result of pyroelectric detector modeling, we find the possibility of implementing optimum device structure.

  • PDF