• 제목/요약/키워드: RELAP5 code

검색결과 110건 처리시간 0.022초

Electric power frequency and nuclear safety - Subsynchronous resonance case study

  • Volkanovski, Andrija;Prosek, Andrej
    • Nuclear Engineering and Technology
    • /
    • 제51권4호
    • /
    • pp.1017-1023
    • /
    • 2019
  • The increase of the alternate current frequency results in increased rotational speed of the electrical motors and connected pumps. The consequence for the reactor coolant pumps is increased flow in primary coolant system. Increase of the current frequency can be initiated by the subsynchronous resonance phenomenon (SSR). This paper analyses the implications of the SSR and consequential increase of the frequency on the nuclear power plant safety. The Simulink $MATLAB^{(R)}$ model of the steam turbine and governor system and RELAP5 computer code of the pressurized water reactor are used in the analysis. The SSR results in fast increase of reactor coolant pumps speed and flow in the primary coolant system. The turbine trip value is reached in short time following SSR. The increase of flow of reactor coolant pumps results in increase of heat removal from reactor core. This results in positive reactivity insertion with reactor power increase of 0.5% before reactor trip is initiated by the turbine trip. The main parameters of the plant did not exceed the values of reactor trip set points. The pressure drop over reactor core is small discarding the possibility of core barrel lift.

A Loss-of-RHR Event under the Various Plant Configurations in Low Power or Shutdown Conditions

  • Seul, Kwang-Won;Bang, Young-Seok;Lee, Sukho;Kim, Hho-Jung
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1997년도 춘계학술발표회논문집(1)
    • /
    • pp.551-556
    • /
    • 1997
  • A present study addresses a loss-of-RHR event as an initiating event under specific low power or shutdown conditions. Two typical plant configurations, cold leg opening case with water-filled steam generators and pressurizer opening case with emptied steam generators, were evaluated using the RELAP5/ MOD3.2 code. The calculation was compared with the experiment conducted at ROSA-IV/LSTF in Japan. As a result, the code was capable of simulating the system transient behavior following the event. Especially, thermal hydraulic transport processes including non-condensable gas behavior were reasonably predicted with an appropriate time step and CPU time. However, there were some code deficiencies such as too large system mass errors and severe flow oscillations in core region.

  • PDF

Incorporation of Henry-Fauske Critical Flow Model into TRAC-PF1

  • Hwang, Tae-Suk;Lee, Jae-Hoon;Yoo, Byung-Tae;Cho, Chang-Sok
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1998년도 춘계학술발표회논문집(1)
    • /
    • pp.713-718
    • /
    • 1998
  • Henry-Fauske critical flow model was incorporated into TRAC-PF1 to correct some errors in the original TRAC-PFI critical flow model. Henry-Fouske mode1 was numerically implemented and tested against steady-state steam-water experimental data. The model was incorporated into TRAC-PFI and code assessment against Marviken Critical Flow Tests 15 and 24 was carried out. Calculations using RELAP5/MOD3 were also made for comparison. Ten cases were calculated each test and sensitivity study on nodalization as well as critical flow or model was performed Stand-alone numerical model test and code assessment were done for verification and validation of code modification. Calculation results show that the modified version of TRAC-PF1 has a capability to model critical flow correctly in various conditions.

  • PDF

Development of TREND dynamics code for molten salt reactors

  • Yu, Wen;Ruan, Jian;He, Long;Kendrick, James;Zou, Yang;Xu, Hongjie
    • Nuclear Engineering and Technology
    • /
    • 제53권2호
    • /
    • pp.455-465
    • /
    • 2021
  • The Molten Salt Reactor (MSR), one of the six advanced reactor types of the 4th generation nuclear energy systems, has many impressive features including economic advantages, inherent safety and nuclear non-proliferation. This paper introduces a system analysis code named TREND, which is developed and used for the steady and transient simulation of MSRs. The TREND code calculates the distributions of pressure, velocity and temperature of single-phase flows by solving the conservation equations of mass, momentum and energy, along with a fluid state equation. Heat structures coupled with the fluid dynamics model is sufficient to meet the demands of modeling MSR system-level thermal-hydraulics. The core power is based on the point reactor neutron kinetics model calculated by the typical Runge-Kutta method. An incremental PID controller is inserted to adjust the operation behaviors. The verification and validation of the TREND code have been carried out in two aspects: detailed code-to-code comparison with established thermal-hydraulic system codes such as RELAP5, and validation with the experimental data from MSRE and the CIET facility (the University of California, Berkeley's Compact Integral Effects Test facility).The results indicate that TREND can be used in analyzing the transient behaviors of MSRs and will be improved by validating with more experimental results with the support of SINAP.

Gravity-Injection Core Cooling After a Loss-of-SDC Event n the YGN Units 3 & 4

  • Seul, Kwang-Woo;Bang, Young-Seok;Kim, Hho-Jung
    • Nuclear Engineering and Technology
    • /
    • 제31권5호
    • /
    • pp.476-485
    • /
    • 1999
  • In order to evaluate the gravity-injection capability to maintain core cooling after a loss-of-shutdown-cooling event during shutdown operation, the plant conditions of the Yong Gwang Units 3&4 were reviewed. The six cases of possible gravity-injection paths from the refueling water tank (RWT) were identified and the thermal-hydraulic analyses were performed using the RELAP5/MOD3.2 code. The core cooling capability was significantly dependent on the gravity-injection path, the RCS opening, and the injection rate. In the cases with the pressurizer manway opening higher than the RWT water level, the coolant was held up in the pressurizer and the system pressure continued increasing after gravity-injection. The gravity injection eventually stopped due to the high system pressure and the core was uncovered. In the cases with the injection path and opening on the same leg side, the core cooling was dependent on whether the water injected from the RWT passed the core region or not. However, in the cases with the injection path and opening on the different leg side, the system was well depressurized after gravity-injection and the core boiling was successfully prevented for a long-term transient. In addition, from the sensitivity study on the gravity-injection flow rate, it was found that about 54 kg/s of injection rate was required to maintain the core cooling and the core cooling could be provided for about 10.6 hours after event with that injection rate from the RWT. Those analysis results would provide useful information to operators coping with the event.

  • PDF

공기와 물의 이상 자연순환 유동의 1 차원 해석 (One-Dimensional Analysis of Air-Water Two Phase Natural Circulation Flow)

  • 박래준;하광순;김재철;홍성완;김상백
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2626-2631
    • /
    • 2007
  • Air-water two phase natural circulation flow in the T-HERMES (Thermo-Hydraulic Evaluation of Reactor cooling Mechanism by External Self-induced flow)-1D experiment has been evaluated to verify and evaluate the experimental results by using the RELAP5/MOD3 computer code. The RELAP5 results have shown that an increase in the coolant inlet area leads to an increase in the water circulation mass flow rate. However, the water outlet area does not effective on the water circulation mass flow rate. As the coolant outlet moves to a lower position, the water circulation mass flow rate decreases. The water level is not effective on the water circulation mass flow rate. As the height increases in the air injection part, the void fraction increases. However, the void fraction in the upper part of the air injector maintains a constant value. An increase in the air injection mass flow rate leads to an increase in the local void fraction, but it is not effective on the local pressure.

  • PDF

Loss of Coolant Accident Analysis During Shutdown Operation of YGN Units 3/4

  • Bang, Young-Seok;Kim, Kap;Seul, Kwang-Won;Kim, Hho-Jung
    • Nuclear Engineering and Technology
    • /
    • 제31권1호
    • /
    • pp.17-28
    • /
    • 1999
  • A thermal-hydraulic analysis is conducted on the loss-of-coolant-accident (LOCA) during shutdown operation of YGN Units 3/4. Based on the review of plant-specific characteristics of YGN Units 3/4 in design and operation, a set of analysis cases is determined, and predicted by the RELAP5/MOD3.2 code during LOCA in the hot-standby mode. The evaluated thermal-hydraulic phenomena are blowdown, break flow, inventory distribution, natural circulation, and core thermal response. The difference in thermal-hydraulic behavior of LOCA at shutolown condition from that of LOCA at full power is identified as depressurization rate, the delay in peak natural circulation timing and the loop seal clearing (LSC) timing. In addition, the effect of high pressure safety injection (HPSI) on plant response is also evaluated. The break spectrum analysis shows that the critical break size can be between 1% to 2% of cold leg area, and that the available operator action time for the Sl actuation and the margin in the peak clad temperature (PCT) could be reduced when considering uncertainties of the present RELAP5 calculation.

  • PDF

원자로용기 외벽냉각시 원자로공동에서 이상유동 자연순환 해석 (Analysis of Two Phase Natural Circulation Flow in the Reactor Cavity under External Vessel Cooling)

  • 박래준;하광순;김상백;김희동
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.2141-2145
    • /
    • 2004
  • As part of study on thermal hydraulic behavior in the reactor cavity under external vessel cooling in the APR (Advanced Power Reactor) 1400, one dimensional two phase flow of steady state in the reactor cavity have been analyzed to investigate a coolant circulation mass flow rate in the annulus region between the reactor vessel and the insulation material using the RELAP5/MOD3 computer code. The RELAP5/MOD3 results have shown that a two phase natural circulation flow of 300 - 600 kg/s is generated in the annulus region between the reactor vessel and the insulation material when the external vessel cooling has been applied in the APR 1400. An increase in the heat flux of the inner vessel leads to an increase of the coolant mass flow rate. An increase in the coolant outlet area leads to an increase in the coolant circulation mass flow rate, but the coolant inlet area does not effective on the coolant circulation mass flow rate. The change of the lower coolant outlet to a lower position affects the coolant circulation mass flow rate, but the variation trend is not consistent.

  • PDF

피동형 경수로 자동감압계통의 개선에 관한 연구 (Design Enhancements of Automatic Depressurization System in a Passive PWR)

  • Yu, Sung-Sik;Seong, Poong-Hyun
    • Nuclear Engineering and Technology
    • /
    • 제25권4호
    • /
    • pp.515-528
    • /
    • 1993
  • 피동형 원자력 발전소의 설계 특성상 소형 냉각재상실사고시 노심손상이 발생되지 않기 위해서는 자동감압계통의 성공적인 작동이 필수적으로 요구된다. 그러나 기수행된 연구들에서 자동감압계통의 비신뢰도가 소형 냉각재상실사고로부터 기인되는 노심손상빈도에 상당 부분을 기여하고 있음을 알 수 있다. 본 연구에서는 자동감압계통의 불능도에 기여하는 계통의 취약점을 파악함과 함께 계통의 신뢰도를 증대시키기 위한 설계개선 방안들을 제시하고 각 방안에 대한 신뢰도 분석과 함께 열수력학적 타당성 여부를 보기 위한 소형 냉각재상실사고 모의가 RELAP5/MOD3 전산 코드를 사용하여 수행되었다. 신뢰도 분석은 고장수목 기법을 이용하여 수행되어졌다.

  • PDF

안전감압계통의 방출유량을 결정하기 위한 완전급수상실사고 해석 (Analysis of Total Loss of Feedwater Event for the Determination of Safety Depressurization Bleed Capacity)

  • Kwon, Young-Min;Song, Jin-Ho;Ro, Tae-Sun
    • Nuclear Engineering and Technology
    • /
    • 제27권4호
    • /
    • pp.470-482
    • /
    • 1995
  • 2025 MWt 가압경수로인 울진 3, 4호기에는 설계기준초과사고인 완전급수상실사고를 완화하기 위하여 안전감압계통이 채택되었다. 본 논문은 울진 3, 4호기의 안전감압계통의 방출유량을 결정하기 위한 해석방법 및 결과에 대하여 논의하였다. 안전감압계통의 방출용량을 다음과 같은 두가지의 설계요건에 따라 결정하였다 : 1) 두 개의 고압안전주입펌프 중 하나의 펌프만이 작동하고 운전원이 안전감압계통의 한 계열의 감압경로를 가압기안전밸브가 열리자마자 개방하였을 경우 노심노출을 방지하여야 한다 2) 두 개의 고압안전주입펌프가 모두 작동하고 두 계열의 안전감압경로를 가압기안전밸브가 열린 후 30분 뒤에 개방하였을 경우 노심노출을 방지하여야 한다. CEFLASH-4AS/REM 전산코드의 모델 및 해석 결과의 타당성을 검토하기 위하여 REL-AP5/MOD3를 이용한 해석을 수행하였다. 운전원의 복구과정이 없을 경우와 운전원이 충전 및 유출운전에 의해 사고를 완화하는 경우의 완전급수상실사고 경위에 대해 수치모사를 수행하였다. 두 사고 경 위에 대해 CEFLASH-4AS/REM에 의해 예측된 원자로계통의 주요 열수력학적 거동이 RELAP5 /MOD3에 의한 결과와 정성·정량적으로 잘 일치하는 것을 알 수 있었다. 결론적으로 울진 3, 4호기에 대해 완전급수상실사고시 안전감압계통을 이용한 충전 및 유출운전에 의해 잔열제거 및 일차계통냉각재 재고량 유지가 성공적으로 이루어짐을 수치모사를 통해 확인 할 수 있었다.

  • PDF