Abstract

In a Passive PWR, the successful actuation of Automatic Depressurization System (ADS) is essentially required so that no core damage is occurred following small LOCA. But it has been shown in the previous studies that Core Damage Frequency (CDF) from small LOCA is significantly caused by unavailability of ADS. In this study, the design vulnerabilities impacting the ADS unavailability have been identified and the design improvement items have been proposed through the system reliability assessment using the fault tree methodology The impacts on CDF according to the change of system unavailability have also been analyzed. In addition, small LOCA simulation using RELAP5/MOD3 code has been performed to show the thermal-hydraulic feasibility of the suggested design enhancements.

피동형 원자력 발전소의 설계 특성상 소형 냉각재상실사고시 노심손상이 발생되지 않기 위해서는 자동감압계통의 성공적인 작동이 필수적으로 요구된다. 그러나 기수행된 연구들에서 자동감압계통의 비신뢰도가 소형 냉각재상실사고로부터 기인되는 노심손상빈도에 상당 부분을 기여하고 있음을 알 수 있다. 본 연구에서는 자동감압계통의 불능도에 기여하는 계통의 취약점을 파악함과 함께 계통의 신뢰도를 증대시키기 위한 설계개선 방안들을 제시하고 각 방안에 대한 신뢰도 분석과 함께 열수력학적 타당성 여부를 보기 위한 소형 냉각재상실사고 모의가 RELAP5/MOD3 전산 코드를 사용하여 수행되었다. 신뢰도 분석은 고장수목 기법을 이용하여 수행되어졌다.