• Title/Summary/Keyword: RC Beam

Search Result 936, Processing Time 0.025 seconds

The Performance Improvement of Strengthened RC Beams Using an Inserted Plate (FRP-콘크리트 경계면 삽입플레이트 활용을 통한 휨 보강 철근콘크리트 보의 성능개선)

  • Ahn, Mi-Kyoung;Lee, Sang-Moon;Jung, Woo-Young
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.73-74
    • /
    • 2010
  • The objective of this research is to improve the flexural capacity of RC Beams. To delay prematured tension failure of concrete specimen and to improve flexural capacity of RC beam by increasing the contribution of FRP strengthening plates, a method for inserting a laminate to the interface between concrete and FRP materials. This method makes it possible to increase overall flexural performance of RC beam by FRP plate compared to normal RC beams and RC beam strengthened by bonded FRP plates. The new bonding technique is applicable to all types of reinforcement available FRP laminate, and in principle is also applicable to materials other than FRP.

  • PDF

Weibull distribution based constitutive model for nonlinear analysis of RC beams

  • Murthy, A. Ramachandra;Priya, D. Shanmuga
    • Structural Engineering and Mechanics
    • /
    • v.61 no.4
    • /
    • pp.463-473
    • /
    • 2017
  • Reinforced concrete is a complex material to be modeled in finite element domain. A proper material model is necessary to represent the nonlinear behaviour accurately. Though the nonlinear analysis of RC structures evolved long back, still an accurate and reliable model to predict the realistic behaviour of components are limited. It is observed from literature that there are three well-known models to represent the nonlinear behaviour of concrete. These models include Chu model (1985), Hsu model (1994) and Saenz model (1964).A new stress-strain model based on Weibull distribution has been proposed in the present study. The objective of the present study is to analyze a reinforced concrete beam under flexural loading by employing all the models. Nonlinear behaviour of concrete is considered in terms of stress vs. strain, damage parameter, tension stiffening behaviour etc. The ductility of the RC beams is computed by using deflection based and energy based concepts. Both deflection ductility and energy based ductility is compared and energy based concept is found to be in good correlation with the experiments conducted. The behavior of RC beam predicted using ABAQUS has been compared with the corresponding experimental observations. Comparison between numerical and experimental results confirms that these four constitutive models are reliable in predicting the behaviour of RC structures and any of the models can be employed for analysis.

Performance of RC Beams Strengthened with FRP-Aluminum Composite Hollow Beam Under the Fire (RC보에 대한 FRP-Aluminum 유공복합보의 보강성능에 관한 연구)

  • Lee, Jae-Ik;Choi, Yeol
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.2
    • /
    • pp.153-160
    • /
    • 2010
  • The widespread deterioration of concrete structures has required the development of new and innovative materials and technologies for strengthening and repair. Recently Fiber reinforced polymer(FRP) composites have received widespread attention as materials for the strengthening and repair of the deteriorated concrete structures. This paper presents the results of Fire-performance of RC beams strengthened with FRP-Aluminum composit hollow beams. Test results show that the higher-damaged FRP strengthened RC beams are more vulnerable to the fire and decrease the effect of FRP strenthening.

Mechanical behavior of RC beams bonded with thin porous FGM plates: Case of fiber concretes based on local materials from the mountains of the Tiaret highlands

  • Benferhat Rabia;Tahar Hassaine Daouadji;Rabahi Abderezak
    • Coupled systems mechanics
    • /
    • v.12 no.3
    • /
    • pp.241-260
    • /
    • 2023
  • The objective of this study is to evaluate the effects of adding fibers to concrete and the distribution rate of the porosity on the interfacial stresses of the beams strengthened with various types of functionally graded porous (FGP) plate. Toward this goal, the beams strengthened with FGP plate were considered and subjected to uniform loading. Three types of beams are considered namely RC beam, RC beam reinforced with metal fibers (RCFM) and RC beam reinforced with Alfa fibers (RCFA). From an analytical development, shear and normal interfacial stresses along the length of the FGP plates were obtained. The accuracy and validity of the proposed theoretical formula are confirmed by the others theoretical results. The results showed clearly that adding fibers to concrete and the distribution rate of the porosity have significant influence on the interfacial stresses of the beams strengthened with FGP plates. Finally, parametric studies are carried out to demonstrate the effect of the mechanical properties and thickness variations of FGP plate, concrete and adhesive on interface debonding, we can conclude that, This research is helpful for the understanding on mechanical behavior of the interface and design of the FRP-RC hybrid structures.

Hysteresis Characteristics of RC Exterior Beam-Column Joint Retrofitted with Haunch (헌치를 이용하여 보강된 RC 보-기둥 외부접합부의 반복이력 특성)

  • Lee, Young Wook;Park, Hyeong Kyeon
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.21 no.3
    • /
    • pp.115-123
    • /
    • 2017
  • To investigate the cyclic characteristics of the retrofitted exterior joints of RC frame with haunch, 70% scaled 6 beam-column exterior joint subassemblies were designed according to design guideline according to 1988 and tested with cyclic loading up to 3.5% story drift ratio. During the experiments axial forces are applied to columns to simulate gravity load. Experimental results shows that the strength of retrofitted specimens was increased steadily until 2.5% story drift ratio and their strengths increased more than 1.7 times of the non-retrofitted in case that main bar was bent away from exterior joint. The joint strength and effective stiffness of the retrofitted specimen was increased and results in more deformation capacity compared to the non-retrofitted.

Shear Strength of Hybrid Steel Beam with Reinforced Concrete Ends (단부 RC조와 중앙부 철골조로 이루어진 혼합구조 보의 전단내력에 관한 실험적 연구)

  • 김욱종;최종권;문정호;이리형;이동렬
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.04b
    • /
    • pp.457-462
    • /
    • 1998
  • An experimental study was carried out for hybrid steel beams with reinforced concrete ends. The purpose is to examine the shear strength and to develop the design methodology of the RC-S connection region. Tested were four beams which included a reference beam and three beams with various parameters. The reference beam was used to make a comparison with remaining specimens. The test parameters were focused mostly on the concentrated shear reinforcements. The ratio of concentrated shear reinforcements and their types were investigated in this study.

  • PDF

Experimental study of beam-column joints in axially loaded RC columns strengthened by steel angles and strips

  • Adam, Jose M.;Gimenez, Ester;Calderon, Pedro A.;Pallares, Francisco J.;Ivorra, Salvador
    • Steel and Composite Structures
    • /
    • v.8 no.4
    • /
    • pp.329-342
    • /
    • 2008
  • The strengthening of reinforced concrete (RC) columns by steel angles and strips (steel cage) is one of various techniques available to increase ultimate column load. Different authors have shown the influence of the beam-column joint on the behaviour of columns strengthened by steel cages. This paper presents an experimental study carried out at the Universidad Polit$\acute{e}$cnica de Valencia with the aim of analysing two different techniques to solve the strengthening close to the joint and the influence on the behaviour of RC columns strengthened steel cages. The ultimate loads obtained in the laboratory tests for these two techniques are compared to that specified by Eurocode 4.

Interfacial stresses in porous PFGM-RC hybrid beam

  • Benferhat Rabia;Hassaine Daouadji Tahar;Rabahi Abderezak
    • Advances in materials Research
    • /
    • v.13 no.1
    • /
    • pp.37-53
    • /
    • 2024
  • This paper presents a careful theoretical investigation into interfacial stresses in RC beams strengthened with externally bonded imperfect FGM plate. In this study, an original model is presented to predict and to determine the stresses concentration at the imperfect FGM end, with the new theory analysis approach. Stress distributions, depending on an inhomogeneity constant, were calculated and presented in forms. It is shown that both the shear and normal stresses at the interface are influenced by the material and geometry parameters of the composite beam, and it is shown that the inhomogeneities play an important role in the distribution of interfacial stresses. The theoretical predictions are compared with other existing solutions. The numerical resolution was finalized by taking into account the physical and geometric properties of materials that may play an important role in reducing the stress values. This research is helpful for the understanding on mechanical behaviour of the interface and design of the PFGM-RC hybrid structures.

Evaluation of Load Capacity Reduction in RC Beam with Corroded FRP Hybrid Bar and Steel (철근부식을 고려한 FRP Hybrid Bar 및 일반 철근을 가진 RC 보의 내력저하 평가)

  • Oh, Kyung-Suk;Moon, Jin-Man;Park, Ki-Tae;Kwon, Seung-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.2
    • /
    • pp.10-17
    • /
    • 2016
  • Steel corrosion is a very significant problem both to durability and structural safety since reinforcement has to support loads in tensile region in RC(Reinforced Concrete) member. In the paper, newly invented FRP Hybrid Bar and normal steel are embedded in RC beam member, and ICM (Impressed Current Method) is adopted for corrosion acceleration. Utilizing the previous theory of Faraday's Law, corrosion amount is calculated and flexural tests are performed for RC beam with FRP Hybrid Bar and steel, respectively. Corrosion amount level of 4.9~7.8% is measured in normal RC member and the related reduction of flexural capacity is measured to be -25.4~-50.8%, however there are no significant reduction of flexural capacity and corrosion initiation in RC samples with FRP Hybrid Bar due to high resistance of epoxy-coated steel to corrosion initiation. In the accelerated corrosion test, excellent performance of anti-corrosion and bonding with concrete are evaluated but durability evaluation through long-term submerged test is required for actual utilization.

Fragility curves and loss functions for RC structural components with smooth rebars

  • Cardone, Donatello
    • Earthquakes and Structures
    • /
    • v.10 no.5
    • /
    • pp.1181-1212
    • /
    • 2016
  • Fragility and loss functions are developed to predict damage and economic losses due to earthquake loading in Reinforced Concrete (RC) structural components with smooth rebars. The attention is focused on external/internal beam-column joints and ductile/brittle weak columns, designed for gravity loads only, using low-strength concrete and plain steel reinforcing bars. First, a number of damage states are proposed and linked deterministically with commonly employed methods of repair and related activities. Results from previous experimental studies are used to develop empirical relationships between damage states and engineering demand parameters, such as interstory and column drift ratios. Probability distributions are fit to the empirical data and the associated statistical parameters are evaluated using statistical methods. Repair costs for damaged RC components are then estimated based on detailed quantity survey of a number of pre-70 RC buildings, using Italian costing manuals. Finally, loss functions are derived to predict the level of monetary losses to individual RC components as a function of the experienced response demand.