• Title/Summary/Keyword: RC 보

Search Result 900, Processing Time 0.027 seconds

The Mechanical Properties and Hand of Cotton Fabrics with the Variation of Weft Density (면직물의 위사밀도 변화에 따른 역학특성 및 태)

  • Bae Jin-Hwa;Park Jung-Whan;An Seung-Kook
    • Science of Emotion and Sensibility
    • /
    • v.8 no.4
    • /
    • pp.345-354
    • /
    • 2005
  • In this study, the mechanical properties and hand characteristics have been analyze4 according to fabric structural parameters such as the weft density and weave stricture of cotton fabric. KES-FB system was used to measure hand characteristics and mechanical properties of fabric. The weft density made an effect on bending and shear properties but not on tensile , compression, and surface properties. In case of wearing property, B/w, 2HG/G, 2HB/B, 2HB/W, $\sqrt[3]{B/W}$, $\sqrt{2HB/W}$, W/T, WC/W were affected tv the weft density. The crimp was highly correlated with the tightness, hand, wearing an4 mechanical properties, specially tensile linearity, bending, shear, and compression properties. The weft crimp influenced the bending, shear, compression resilience, surface roughness, hand, and wearing properties. The tightness has an effect on tile bending, shear, compression, surface friction, hand, and wearing properties.

  • PDF

Seismic Retrofit Effect for Column of Subway Tunnel Reinforced by FRP-Ductile Material Layered Composites (FRP-연성재 적층복합체로 보강된 도시철도 개착식 터널 기둥의 내진보강효과)

  • Kim, Doo-Kie;Go, Sung-Hyuk;Kim, Jin-Yeong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.6
    • /
    • pp.85-92
    • /
    • 2010
  • Recently the earthquake occurrences in Korea are likely to increase. Therefore, the facilities such as bridges and tunnels under the unexpected earthquakes need to be enhanced. Especially most of the subways previously built before 1988 have not been seismically designed, so their seismic safety requirements are required to be inspected and/or reinforced. In this study, the seismic reinforcement using FRP-ductile material layered composites was proposed to reinforce for the subway columns. Material properties of FRP-ductile material layered composites were calculated by laboratory tests considering the laminated conditions of the composites. Numerical simulations were performed using the experimental results of the specimens and the calculated properties of the composites. Seismic performance varied according to the types of composites: ductile material, number of layers, fiber orientations.

Improvement of Structural Performance of RC Beams retrofitted Hybrid Fiber using Recycled Coarse Aggregate and Ground Granulated Blast Furnace Slag (순환굵은골재 및 고로슬래그 미분말을 사용한 하이브리드섬유보강 철근콘크리트 보의 구조성능 개선)

  • Yi, Dong-Ryul;Ha, Gee-Joo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.6
    • /
    • pp.1-10
    • /
    • 2014
  • In this study, thirteen reinforced concrete beams, ground granulated blast furnace slag, replacing recycled coarse aggregate with PVA fiber (BSPG series) and recycled coarse aggregate with hybrid fiber ($BSPGR_1$, $BSPGR_2$ series), and standard specimen (BSS) were constructed and tested under monotonic loading. Experimental programs were carried out to improve and evaluate the Structural performance of such test specimens, such as the load-displacement, the failure mode, and the maximum load carrying capacity. All the specimens were modeled in 1/2 scale-down size. Test results showed that test specimens ($BSPGR_1$, $BSPGR_2$ series) was increased the compressive strength by 13%, the maximum load carrying capacity by 4~21% and the ductility capacity by 4~28% in comparison with the standard specimen (BSS). And the specimens ($BSPGR_1$, $BSPGR_2$ series) showed enough ductile behavior and stable flexural failure.

The Prediction of Debonding Strength on the Reinforced Concrete Beams Strengthened with fiber Reinforced Polymer (섬유복합체로 휨보강된 RC보의 박리하중 예측에 관한 연구)

  • Hong Geon-Ho;Shin Yeong-Soo
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.6 s.90
    • /
    • pp.903-910
    • /
    • 2005
  • In recent years, fiber reinforced polymer(FRP) plates have shown a great promise as an alternative to steel plates for reinforced concrete beam rehabilitation. Reinforced concrete beams strengthened with externally bonded FRP sheets to the tension face can exhibit ultimate flexural strengths several times greater than their original strength if their bond strength is enough. Debonding failure, however, may occur before the strengthened beam can achieve its enhanced flexural strength. The purpose of this paper is to investigate the debonding failure strength of FRP-strengthened reinforced concrete beams. An analytical procedure for calculating debonding load between concrete and strengthening FRP is presented. Based on the local bond stress-slip relationship in the previous studies, uniform bond stress is assumed on the effective bond length. The analytical expressions are developed from linear elastic theory and statistical analyses of experimantal results reported in the literature. The proposed method is verified by comparisons with experimental results reported in the previous researches.

Reinforcement Effect of Reinforced Concrete Beams Strengthened with Grid-type Carbon Fiber Plastics (격자형 탄소섬유로 보강한 R/C보의 보강효과)

  • Jo, Byung-Wan;Tae, Ghi-Ho;Kwon, Oh-Hyuk
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.3
    • /
    • pp.377-385
    • /
    • 2003
  • Flexural characteristics of the R.C beams strengthened with newly-developed grid-type carbon fiber plastics(CFRP-GRIDS) were investigated. The tests were conducted under the four-points load to the failure to investigate the strengthening effects of CFRP-GRIDS on the beams. Results showed that initial cracks appeared in the boundary layers of fibers embedded in the newly-placed mortar concrete slowly progressed to the direction of supports and showed fracture of fiber plastics and brittle failure of concrete in compression in sequence after the yielding of steel reinforcement. Accordingly, the appropriate area of Grid-type carbon-fiber plastics in the strengthening design of deteriorated RC structures should be limited and given based on the ultimate strength design method to avoid the brittle failure of concrete structures.

Bond-Slip Model of Interface between CFRP Sheets and Concrete Beams Strengthened with CFRP (탄소섬유시트로 보강된 콘크리트보의 경계면 부착-슬립모델)

  • Kim, Sung-Bae;Kim, Jang-Ho Tay;Nam, Jin-Won;Kang, Suk-Hwa;Byun, Keun-Joo
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.4
    • /
    • pp.477-486
    • /
    • 2008
  • External bonding of carbon fiber reinforced plastic sheets has recently emerged as a popular method for strengthening reinforced concrete structures. The behavior of CFRP-strengthened RC structure is often controlled by the behavior of the interface between CFRP sheets and concrete. In this study, a review of models on bond strength, bond-slip, and interfacial stresses has been first carried out. Then a new bond-slip model is proposed. The proposed bond-slip model has bilinear ascending regions and exponential descending region derived from modifications mode on the conventional bilinear bond-slip model. The comparison of the results with those of existing experiment researches on bond-slip models indicate good agreements.

-An Analysis of Pre-Stressed Concrete Farn Sild by the Finite Element Method- (유한요소법에 의한 PC 농업용 사이로의 해석에 관한 연구 -제2보 탄성지반에 놓인 경우-)

  • 조진구;조현영;박병기
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.24 no.3
    • /
    • pp.73-83
    • /
    • 1982
  • study aims to derive a rational method for the analysis of the farm silo supported on an elastic foundation in which it is assumed that the reaction pressure of the soil at a point is proportional to the deflection at that point. In order to investigate the effects of an elastic foundation on the behaviour of the structures on it, the analysis of the farm silo resting on an elastic foundation was compared with the solution that the ground support may be assumed uniform (which was obtained from part I of this paper). To calculate the deformation of an elastic foundation, Boussinesq's solution which allows an interaction of the various parts of ground was adopted. In this case, the foundation was treated as a superparametric element additionally. In the evaluation of an element stiffness matrix, Gauss quadrature' was used. In above numerical integration, 3-point rule for the farm silo wall and the footing was introduced and 2-point rule for the evaluation of a reaction between the footing and the elastic foundation was adopted. The stresses of a farm silo on an elastic foundation were smaller than those which the distribution of contact pressure between the footing and the soil is assumed uniformly. Since the differences of stresses were remarkable in PS structures than RC structures, it is desirable that designers take into account the effect of an elastic foundation for the case of PS structures. It can be noted that while the effect of an elastic foundation was more conspicuously observed in near of the ground, the value of stresses at far from the soil was little affected by an supported soil.

  • PDF

An Experimental Study on the Deflection Estimation of RC Flexural Member by Corrosion of Reinforcement (철근 부식에 따른 철근콘크리트 휨 부재의 처짐 산정에 대한 실험적 연구)

  • Kim, Jee-Sang;Moon, Hyeong-Gab
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.9 no.2
    • /
    • pp.143-151
    • /
    • 2021
  • Flexural test of reinforced concrete beam with corroded reinforcement were performed to measure the deflection, curvature and cracking moment for various bar diameter and amounts of corrosion. The amounts of corrosion are varied from 0% to 10% by weight and the bar diameters are chosen as 10mm, 13mm, and 19mm. The changes in reinforcement diameter do not affect the flexural behaviors significantly according to this experiment. If the amounts of corrosion is greater than 2%, the deflection and curvature of the beam increased and the cracking moment decreased. It means that the lower amounts of corrosion does not result structural damage in flexural member significantly as in direct tensile test. A modification factor considering an effect of amounts of corrosion is proposed based on the experiment, which can be used to determine the deflection of reinforced concrete beam with corroded reinforcement.

Shear Strengthening Effect by Deviator Location in Externally Post-tensioning Reinforcement (외적 포스트텐셔닝 보강에서 데비에이터의 위치에 따른 전단보강효과)

  • Lee, Swoo-Heon;Shin, Kyung-Jae;Lee, Hee-Du
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.6
    • /
    • pp.3-10
    • /
    • 2018
  • This paper described the shear strengthening effect by deviator location in pre-damaged reinforced concrete (RC) beams strengthened with externally post-tensioning steel rods. Three reinforced concrete beams as control beam and eight post-tensioned beams using external steel rods were tested to fail in shear. The externally post-tensioning material was a steel rod of 22 mm diameter, and it had a 655 MPa yield strength and an 805 MPa tensile strength. Specimens depend on multiple variables, such as the number of deviators, location of deviator, and load pattern. The pre-damaged loads up to about 2/3 of ultimate shear capacities were applied to specimens using displacement control and the diagonal shear crack just occurred at these loading levels. And then, the post-tensioning up to when a strain of steel rod reaches about $2000{\mu}{\varepsilon}$ was continuously applied to beam. A displacement control was changed to a load control during post-tensioning. The post-tensioning resulted in increase of load-carrying capacity and restoration of existing deflection. Also, it prevented the existing diagonal cracks from excessively growing. Two deviators effectively improved the load capacity when compared with in case of test which one deviator at mid-span installed. When deviators were located near region which the diagonal crack occurred on, the strengthening impact by post-tensioning was greater.

Crack Monitoring of RC beam using Surface Conductive Crack Detection Patterns based on Parallel Resistance Network (병렬저항회로에 기반한 표면 전도성 균열감지패턴을 사용한 콘크리트 휨 부재의 균열 감지 )

  • Kyung-Joon Shin;Do-Keun Lee;Jae-Heon Hong;Dong-Chan Shin;Jong-Hyun Chae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.5
    • /
    • pp.67-74
    • /
    • 2023
  • A large number of concrete structures are built and used around the world. To ensure their safe and continuous use, these structures require constant inspection and maintenance. While man-powered inspection and maintenance techniques are efficient, they can only provide intermittent status checks at the time of on-site inspection. Therefore, there is a growing need for a system that can continuously monitor the condition of the structure. A study was conducted to detect cracks and damage by installing a conductive coating on the surface of a concrete structure. A parallel resistance pattern that can monitor the occurrence and progression of cracks was developed by reflecting the structural characteristics of concrete structure. An empirical study was conducted to veryfy the application of the proposed method. The crack detection pattern was installed on the reinforced concrete beams, and the crack monitoring method was verified through applying a load on the beams.