Experimental study on innovative tubular web RBS connections in steel MRFs with typical shallow beams

  • Saleh, Aboozar;Zahrai, Seyed M.;Mirghaderi, Seyed R.
    • Structural Engineering and Mechanics
    • /
    • 제57권5호
    • /
    • pp.785-808
    • /
    • 2016
  • An innovative Reduced Beam Section (RBS) connection, called Tubular Web RBS connection (TW-RBS), has been recently introduced and its performance has been numerically investigated in some earlier studies. The TW-RBS connection is a kind of accordion-web RBS connection in which part of the flat web of the beam is replaced by a steel tube at the expected region of the plastic hinge. This paper presents experimental results of three TW-RBS connections under cyclic loading. Obtained results indicated that TW-RBS reduces contribution of the beam web to the whole moment strength and creates a ductile fuse far from components of the beam-to-column connection. Besides, TW-RBS connection can increase story drift capacity up to 9% in the case of shallow beams which is much more than those stipulated by the current seismic codes. Based on the experimental results, the tubular web in the plastic hinge region improves lateral-torsional buckling stability of the beam such that only local buckling of the beam flange at the center of the reduced section was observed during the tests. In order to achieve a better understanding, behavior of all TW-RBS specimens are also numerically investigated and compared with those of experimental results.

A new replaceable fuse for moment resisting frames: Replaceable bolted reduced beam section connections

  • Ozkilic, Yasin O.
    • Steel and Composite Structures
    • /
    • 제35권3호
    • /
    • pp.353-370
    • /
    • 2020
  • This paper describes a new type of replaceable fuse for moment resisting frames. Column-tree connections with beam splice connections are frequently preferred in the moment resisting frames since they eliminate field welding and provide good quality. In the column-tree connections, a part of the beam is welded to the column in the shop and the rest of the beam is bolted with the splice connection in the field. In this study, a replaceable reduced beam section (R-RBS) connection is proposed in order to eliminate welding process and facilitate assembly at the site. In the proposed R-RBS connection, one end is connected by a beam splice connection to the beam and the other end is connected by a bolted end-plate connection to the column. More importantly is that the proposed R-RBS connection allows the replacement of the damaged R-RBS easily right after an earthquake. Pursuant to this goal, experimental and numerical studies have been undertaken to investigate the performance of the R-RBS connection. An experimental study on the RBS connection was used to substantiate the numerical model using ABAQUS, a commercially available finite element software. Additionally, five different finite element models were developed to conduct a parametric study. The results of the analysis were compared in terms of the moment and energy absorption capacities, PEEQ, rupture and tri-axiality indexes. The design process as well as the optimum dimensions of the R-RBS connections are presented. It was also demonstrated that the proposed R-RBS connection satisfies AISC criteria based on the nonlinear finite element analysis results.

Investigation of major parameters affecting instablility of steel beams with RBS moment connections

  • Tabar, A.Moslehi;Deylami, A.
    • Steel and Composite Structures
    • /
    • 제6권3호
    • /
    • pp.203-219
    • /
    • 2006
  • One of the most promising ways through which a steel moment frame may attain high energy dissipating capability is to trim off a portion of the beam flanges near the column face. This type of moment connection, known as Reduced Beam Section (RBS) connection, has notable superiority in comparison with other moment connection types. As the result of the advantages of RBS moment connection, it has widely being used in practice. In spite of the good hysteretic behaviour, an RBS beam suffers from an undesirable drawback, which is local and lateral instability of the beam. The instability in the RBS beam reduces beam load-carrying capacity. This paper aims to investigate key issues influencing cyclic behaviour of RBS beams. To this end, a numerical analysis was conducted on a series of steel subassemblies with various geometric properties. The obtained results together with the existing experimental data are used to study the instability of RBS beams. A new slenderness concept is presented to control an RBS beam for combined local and lateral instability. This concept is in good agreement with the numerical and experimental results. Finally, a model is developed for the prediction of the magnitude of moment degradation owing to the instability of an RBS beam.

Increasing plastic hinge length using two pipes in a proposed web reduced beam section, an experimental and numerical study

  • Zahrai, Seyed M.;Mirghaderi, Seyed R.;Saleh, Aboozar
    • Steel and Composite Structures
    • /
    • 제23권4호
    • /
    • pp.421-433
    • /
    • 2017
  • Experimental and numerical studies of a newly developed Reduced Beam Section (RBS) connection, called Tubular Web RBS connection (TW-RBS) have been recently conducted. This paper presents experimental and numerical results of extending the plastic hinge length on the beam flange to increase energy dissipation of a proposed version of the TW-RBS connection with two pipes, (TW-RBS(II)), made by replacing a part of flat web with two steel tubular web at the desirable location of the beam plastic hinge. Two deep-beam specimens with two pipes are prepared and tested under cyclic loads. Obtained results reveal that the TW-RBS(II) like its type I, increases story drift capacity up to 6% in deep beam much more than that stipulated by the current seismic codes. Based on test results, the proposed TW-RBS(II) helps to dissipate imposed energy up to 30% more than that of the TW-RBS(I) specimens at the same story drift and also reduces demands at the beam-to-column connection up to 30% by increasing plastic hinge length on the beam flange. The TW-RBS(II) specimens are finally simulated using finite element method showing good agreement with experimental results.

Numerical cyclic behavior of T-RBS: A new steel moment connection

  • Ataollahi, Saeed;Banan, Mohammad-Reza;Banan, Mahmoud-Reza
    • Steel and Composite Structures
    • /
    • 제21권6호
    • /
    • pp.1251-1264
    • /
    • 2016
  • After observing relatively poor performance of bolted web-welded flange beam-to-column connections during 1994 Northridge earthquake, various types of connections based on two concepts of: (i) strengthening the connection; and (ii) weakening the beam ends were proposed. Among these modified or newly proposed connections, bolted T-stub connection follows the concept of strengthening. One of the connections with the idea of weakening the beam ends is reduced beam section (RBS). In this paper, finite element simulation is used to study the cyclic behavior of a new proposed connection developed by using a combination of both mentioned concepts. Investigated connections are exterior beam-to-column connections designed to comply with AISC provisions. The results show that moment capacity and dissipated energy of the new proposed connection is almost the same as those computed for a T-stub connection and higher than corresponding values for an RBS connection.

RBS 연결부를 갖는 보에 대한 부등 단면 보 요소 (Non-Prismatic Beam Element for Beams with RBS Connection)

  • 김기동;고만기;황병국;배창규
    • 한국강구조학회 논문집
    • /
    • 제16권6호통권73호
    • /
    • pp.833-846
    • /
    • 2004
  • 포스트-노스리지 연결부를 사용하는 강재 보의 탄성거동을 모델하기 위한 부등 단면 보 요소가 제안된다. 감소 단면 (RBS) 연결부를 갖는 부등단면 부재에 대한 탄성 강성 매트릭스는 수치적분이 필요치 않는 수식으로 표현되고 전단 효과를 포함하고 있다. 또한 균일 단면 보 요소를 사용하여 RBS 연결부를 갖는 보를 모델 하는 간략 방법이 제안된다. 이 방법의 장점은 기존의 보 요소를 사용하여 RBS 연결부를 사용하는 강재 모멘트 골조의 최대 층간 상대 변위 비를 상당히 정확하게 예측할 수 있다는데 있다. 강재 모멘트 골조의 탄성 강성에 감소 단면 연결부가 미치는 영향이 조사되었고, 절점에서의 변형을 고려하기 위한 적절한 모델 선정이 골조의 최대 층간 상대변위 비를 정확히 예측하는데 감소 단면 연결부보다 중요한 역할을 하였다.

Tubular Web Reduced Beam Section (TW-RBS) connection, a numerical and experimental study and result comparison

  • Zahrai, Seyed M.;Mirghaderi, Seyed R.;Saleh, Aboozar
    • Steel and Composite Structures
    • /
    • 제23권5호
    • /
    • pp.571-583
    • /
    • 2017
  • A kind of accordion-web RBS connection, "Tubular Web RBS (TW-RBS)" connection is proposed in this research. TW-RBS is made by replacing a part of web with a tube at the desirable location of the beam plastic hinge. This paper presents first a numerical study under cyclic load using ABAQUS finite element software. A test specimen is used for calibration and comparison of numerical results. Obtained results indicated that TW-RBS would reduce contribution of the beam web to the whole moment strength and creates a ductile fuse far from components of the beam-to-column connection. Besides, TW-RBS connection can increase story drift capacity up to 9% in the case of shallow beams which is much more than those stipulated by the current seismic codes. Furthermore, the tubular web like corrugated sheet can improve both the out-of-plane stiffness of the beam longitudinal axis and the flange stability condition due to the smaller width to thickness ratio of the beam flange in the plastic hinge region. Thus, the tubular web in the plastic hinge region improves lateral-torsional buckling stability of the beam as just local buckling of the beam flange at the center of the reduced section was observed during the tests. Also change of direction of strain in arc shape of the tubular web section is smaller than the accordion webs with sharp corners therefore the tubular web provides a better condition in terms of low-cycle fatigue than other accordion web with sharp corners.

The effect of RBS connection on energy absorption in tall buildings with braced tube frame system

  • Shariati, Mahdi;Ghorbani, Mostafa;Naghipour, Morteza;Alinejad, Nasrollah;Toghroli, Ali
    • Steel and Composite Structures
    • /
    • 제34권3호
    • /
    • pp.393-407
    • /
    • 2020
  • The braced tube frame system, a combination of perimeter frame and bracing frame, is one of the systems used in tall buildings. Due to the implementation of this system in tall buildings and the high rigidity resulting from the use of general bracing, providing proper ductility while maintaining the strength of the structure when exposing to lateral forces is essential. Also, the high stress at the connection of the beam to the column may cause a sudden failure in the region before reaching the required ductility. The use of Reduced Beam Section connection (RBS connection) by focusing stress in a region away from beam to column connection is a suitable solution to the problem. Because of the fact that RBS connections are usually used in moment frames and not tested in tall buildings with braced tube frames, they should be investigated. Therefore, in this research, three tall buildings in height ranges of 20, 25 and 30 floors were modeled and designed by SAP2000 software, and then a frame in each building was modeled in PERFORM-3D software under two RBS-free system and RBS-based system. Nonlinear time history dynamic analysis is used for each frame under Manjil, Tabas and Northridge excitations. The results of the Comparison between RBS-free and RBS-based systems show that the RBS connections increased the absorbed energy level by reducing the stiffness and increasing the ductility in the beams and structural system. Also, by increasing the involvement of the beams in absorbing energy, the columns and braces absorb less energy.

Welded Flange-Bolted Web 강접합부의 파괴모드 추정을 위한 유한요소해석 (Finite Element Analysis for the Failure Mode of Welded Flange-Bolted Web Connection)

  • 조창빈
    • 한국지진공학회논문집
    • /
    • 제3권4호
    • /
    • pp.33-46
    • /
    • 1999
  • 캘리포니아의 강구조 모멘트프레임은 1994년 노스리지 지진시 6.8의 규모와 진앙지에서 근접한 지리적인 악조건에도 불구하고 붕괴나 인명피해 없이 잘 견뎌냈다. 그러나 이후 시행된 조사에서 경제적으로 지진시 안전하다고 믿어져 널리 쓰인 welded flange-bolted web(WFBW) 강접합부(moment connection)의 기둥과 용접의 경계면에서 취성 파괴가 다수 발견되었다. 이논문은 선형파괴역학과 노스리지진이후의 WFBW 강접합부 실험을 이용하여 WFBW 강접합부와 노스리지지진이후 기존 강접합부의 대안으로 추천되고 있는 reduced beam section (RBS) 강접합부의 취성 파괴강도를 결정하는 수치적인 방법을 제안하고 이를 이용하여 이들 강접합부의 취성 파괴모드를 추정하였다.

  • PDF

RBS 철골모멘트접합부의 내진거동평가를 위한 반복재하 실물대(實物大) 시험 (Cycllic Seismic Testing of Full-Scale RBS (Reduced Beam Section) Steel Moment Connections)

  • 이철호;전상우;김진호
    • 한국강구조학회 논문집
    • /
    • 제14권4호
    • /
    • pp.557-566
    • /
    • 2002
  • 본 논문은 4개의 철골모멘트 접합부에 대한 반복재하 실물대(實物大) 실험결과를 요약한 것이다. 주요 실험변수는 기둥과 보의 접합방식 (볼트접합 대 용접) 및 패널존의 강도 (강한 패널존 대 중간강도 패널존)이다. 중간 패널존 강도를 갖는 시험체는 패널존과 RBS 영역 모두에서 균형잡힌 방식으로 에너지가 소산되도록 고려하여 설계된 것으로 패널존 보강비용을 줄이고자 시도한 경우이다. 보웨브가 용접으로 접합된 경우의 시험체들은 특별연성모멘트골조에 요구되는 충분한 접합부 회전성능을 보여 주었지만, 웨브를 볼트로 접합한 시험체들은 스캘럽을 가로지르는 보플랜지의 조기 취성파괴로 인해 열등한 내진성능을 노출하였다. 보웨브를 볼트로 접합하면 비용을 줄일 수 있으나 원래 보단면의 전소성모멘트를 기둥에 전달하기 어려운 것으로 나타났다. 본 연구에서 적용된 것과 같이 양질의 용접시공에 의해 일단 그루브 용접부 자체의 취성파괴 문제가 해결되고 나면, 용접접근공내에 위한 보플랜지 모재의 파단이 다음의 문제로 대두됨을 알 수 있다. 용접접근공 내의 보 플랜지 파단문제를 역학적인 측면에서 이해하는데 도움이 되는 해석적 연구도 수행되었다.