• 제목/요약/키워드: RBM surfaced implant

검색결과 7건 처리시간 0.024초

성견 경골에서 표면처리방법이 다른 4종의 임프란트 골유착에 관한 비교연구 (COMPARATIVE STUDY OF OSSEOINTEGRATION OF 4 DIFFERENT SURFACED IMPLANTS IN THE TIBIA OF DOGS)

  • 홍후석;김태희;류승희;국민석;박홍주;오희균
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제31권1호
    • /
    • pp.46-54
    • /
    • 2005
  • Purpose: This study was performed in order to compare the osseointegration of 4 different surfaced implants in the dog's tibia which has thick dense cortical bone and loose marrow space. Materials & methods: Four mongrel dogs and four different surface types of implants, smooth surfaced AVANA implants, RBM surfaced AVANA implants, HA-coated Steri-Oss implants and SLA Bicon implants, were used in this study. The animals were divided into 4 groups on the basis of implant surface characteristics: Control group, RBM group, HA group, and SLA group. Three implants of each group were installed into the metaphysis of tibia of adult dogs. The animals were sacrificed at 8 weeks after implantation. The undecalcified specimens were prepared for histological examination and histomorphometric analysis of implant-bone contact ratios. Results: Radiographically and histologically good osseointegration of implant was observed in the dense cortical bone, but poor osseointegration was observed in the marrow space. Histologically more bone apposition to implant surface was found in rough surfaced groups than the smooth surfaced, Control group. In histomorphometric findings of cortical bone the average bone-implant contact ratios of HA group (95.4%, p<0.01), RBM group (87.1%, p<0.05), and SLA group (86.0%, p<0.05) were significantly higher than that of Control group (75.9%). In marrow space the average bone-implant contact ratios of HA group (76.1%, p<0.01) and SLA group (45.4%, p<0.05) were significantly higher than that of Control group (29.6%). The ratio of RBM group was higher than that of Control group but there was no significantly difference between RBM group and Control group. Conclusion: These results suggest that the rough surfaced implants can obtain the better osseointegration than the smooth surfaced implant in the cortical and marrow space and that HA-coated implants can obtain the best osseointegration in the marrow space among them.

임플란트 표면에 따른 인공치면세균막 형성에 관한 연구 (THE STUDY OF THE DENTAL PLAQUE FORMATION ON DIFFERENT IMPLANT SURFACES)

  • 김진우;한세진;김경욱
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제34권3호
    • /
    • pp.325-340
    • /
    • 2008
  • The purpose of this study was to evaluate the artificial dental plaque by Streptococcus mutans on 4 different implant surfaces. In this study, the specimens were divided into 4 groups according to implant surface treatment. Uncoated implant group(n=5) which has an uncoated, smooth surfaced implant(Osstem, Korea), SLA implant group(n=5) which has an sandblasted large grit and acid-etched surface implant(Bicon, USA). Oxidized implant group(n=5) which has an oxidized surfaced implant (Osstem, Korea), and RBM implant group(n=5) which has resorbable blasting media(RBM) surfaced implant(Osstem, Korea). Acquired pellicle by human saliva and dental plaque by Streptococcus mutans were made on each implant surface. To analyze the plaque condition on implants surfaces, cell count and optical density were taken as a microbiologic method, and SEM(Scanning Electronic Microscope) findings was also taken for evaluation of surface condition. The following results were obtained. 1. Cell counting results of artificial dental plaque were Uncoated group($658.0{\pm}102.0$), RBM group($878.0{\pm}170.0$), SLA group ($946.0{\pm}42.0$), Oxidized group($992.0{\pm}40.0$), and there was difference between Oxidized group and Uncoated implant group(p<0.05). In case of modified cell counting results by v/w% were RBM group($197.8{\pm}45.2$), Oxidized group($207.04{\pm}8.34$), Uncoated group($261.6{\pm}40.6$), SLA group($315.4{\pm}14.0$), and there was difference between RBM group and SLA group(p<0.05). 2. Optical density results of artificial dental plaque after ultrasonic treatment was that there was difference among groups, and optical density of RBM group was higher than that of Uncoated group(p<0.05). In case of modified optical density results by v/w%, there was difference among groups, and the modified optical density of Uncoated group and SLA group was higher than those of Oxidized group and RBM group(P>0.05). 3. SEM findings of artificial dental plaque on the surfaces of implant as follows; there were artificial dental plaque on the surfaces of all test implants. Streptococcus mutans and by-product were observed at 10,000 times magnified condition on all test implants. Adhesion area of artificial dental plaque was about 1/2 of total surface after 24 hours incubate at $37^{\circ}C$. These results showed that there were differences among implant surfaces on the growth of Streptococcus mutans, and bacteria and by-product were covered about 1/2 area of total implant surfaces at 24 hours incubate at $37^{\circ}C$.

성장 인자가 농축된 Fibrin rich block을 이용한 상악동 거상술에서의 신생골 형성에 관한 연구 (New bone formation using fibrin rich block with concentrated growth factors in maxillary sinus augmentation)

  • 김지민;이주형;박인숙
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제37권4호
    • /
    • pp.278-286
    • /
    • 2011
  • Introduction: This study examined the predictability of new bone formation in the pneumatized maxillary sinus using only fibrin-rich blocks with concentrated growth factors as an alternative to bone grafts. Materials and Methods: Maxillary sinus augmentation was performed in thirty-three patients with a deficient alveolar bone height (mean 3.9 mm). All patients were treated consecutively with sinus membrane elevation via the lateral window approach and panoramic radiograms and cone-beam computed tomograms were taken to evaluate the remaining bone height and the new bone formation in the maxillary sinus, before and after surgery. Four biopsy specimens were taken at the time of implant consolidation (after an average of five months healing) and were stained by H & E and Trichrome staining. Results: None of the patients had postoperative complications during implant consolidation. After an average of 5 months since sinus augmentation, newly formed bone was observed in all cases by a radiographic evaluation. In 4 biopsy samples, newly formed bone was observed along the floor of the replaced bony window. The osteoblast lining and well distinguished Osteocytes in the lacunas were observed in the newly formed bone. Of the 74 implants (4 different surfaced implants - resorbable blast media-surfaced (RBM), Hydroxyapatite (HA) coated, acid-etched, sintered porous-surfaced implant) placed, one RBM implant failed. The success rate was 98.6% after a mean of 15 months. Discussion: These results suggest that maxillary sinus augmentation using fibrin rich block with concentrated growth factors is a successful and predictable technique.

백서에 식립한 치과용 임플란트의 골유착에 흡연이 미치는 영향 (INFLUENCE OF CIGARETTE SMOKE INHALATION ON DENTAL IMPLANT OSSEOINTEGRATION IN THE RAT)

  • 김세호;김성민;김지혁;박영욱;박찬진;정기명;이석근
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제31권4호
    • /
    • pp.291-299
    • /
    • 2005
  • Objectives : It is well known that cigarette smoking is harzardous to the osseointegration of dental implant, due to the impaired wound healing accompanied by reduced alveolar bone density. The aim of this study is to evaluate the influence of cigarette smoke on the implant osseointegration by the time factor consideration. Materials and methods : Twenty-four male Spraque-Dawley rats (8 weeks, weighting 200 to 250g) were used in this study. In the experimental group, 13 rats were exposed to cigarette smoke, 8 minutes per day during 6 weeks, and 12 rats in the control group were not exposed at any time. RBM (Resorbed blasting media) surfaced implant (diameter 3.3mm, length 5.0mm, AVANA Co., Korea) was placed in the right femur of each rat. Each implant with surrounding bone was prepared with microtome (cutting band 0.2mm$^{(R)}$, EXAKT Co., Germany) after 1 day, 2, 4, 8 and 12 weeks and stained with toluidine blue (1%). Another clinical investigation of each implant was also done at each evaluation time. Results : Clinical investigation around implant fixture showed that there were no significant differences between the control and experimental group. Microscopic observation around implant fixture showed that there were significant differences between the control and experimental group at the initial stage after implant fixture installation. Experimental group showed a decreased bone to implant contact within 4 weeks compared to control group, but showed similar characteristics after 4 weeks. Conclusion : Smoking inhalation effect on the dental implant showed the impaired wound healing by vasoconstriction and decreased intramedullary blood flow at initial stage of osseointegration. This experimental results can be clinically useful to the implant surgery of smoking patients.

발치 후 즉시 매식된 서로 다른 두종의 RBM표면 처리된 임플란트에 대한 다기관 후향적 임상연구 (MULTICENTER RETROSPECTIVE STUDY OF IMMEDIATE TWO DIFFERENT RBM SURFACED IMPLANT SYSTEMS AFTER EXTRACTION)

  • 박홍주;국민석;김수관;김영균;조용석;최갑림;오영학;오희균
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제30권3호
    • /
    • pp.258-265
    • /
    • 2008
  • Purpose. This multicenter retrospective study was performed to evaluate the survival and success rates of immediate placement of USII and SSII Osstem implant (Osstem implant Co, Korea) on the maxillary and mandibular anterior and premolar areas. Materials and methods. Dental records were obtained in 37 patients who were treated with immediate implantation on the maxillary and mandibular anterior and premolar areas in 6 different clinics. The 98 implants were evaluated both clinically and radiographically using predefined success criteria. Results. There was no failed implant in all patients. The mean follow up period was 24.7 months (ranged from 12 to 58 months), and 25.1 months (ranged from 16 to 35 months) in USII and SSII implants, respectively. The crestal bone loss was 3 mm in 3 USII implants during 41 months, and in 1 SSII implant during 22 months. The overall success rate was 94.2% and 97.7% in USII and SSII implants, respectively. The age, gender, diameter, or length of implants, and type of surgery were not influenced to the success rate of immediate implantation. Conclusion. These results suggest that USII and SSII Osstem implant can be used successfully in immediate implantation on the maxillary and mandibular anterior and premolar areas.

다양한 양극산화막 처리방법이 임플란트 골유착에 미치는 영향 (EFFECTS OF DIFFERENT OXIDIZED SURFACES OF IMPLANT ON OSSEOINTEGRATION; RESONANCE FREQUENCY AND HISTOMORPHOMETRIC ANALYSIS STUDY IN MINI-PIGS)

  • 권경환;민승기;성대혁;최재영;최성림;차수련;오희균
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제29권5호
    • /
    • pp.383-393
    • /
    • 2007
  • The aim of the present study is to investigate the effect of anodized surface of osseointegration implants by using of resonance frequency analysis (RFA) and histomorphometric analysis. A total of 96 screw-shaped implants were devided into 4 groups. Seventy-two implants were prepared by electrochemical oxidation with 3 different ways; Group 1 (n=24) were prepared at galvanostatic mode in 0.25M sulfuric acid and phosphoric acid, Group 2 (n=24) were prepared at galvanostatic mode in calcium glycerophosphate and calcium acetate, and Group 3 (n=24) were prepared at galvanostatic mode in 0.25M sulfuric acid and phosphoric acid followed by Calcium metaphosphate(CMP) coating. Control group (n=24) were the RBM surfaced implants. The implants were placed in the mandibles of 12 mini pigs. Bone tissue responses were evaluated by resonance frequency analysis(RFA) and histomorphometric analysis that were undertaken at 2, 4 and 6weeks after implant placement. The following result were obtained. 1. Twenty-two of 96 implants (4 in control group, 5 in group 1, 7 in group 2, and 6 in group 3) were failed due to faliure of osseoitegration. The failure rate of osseointegration was 22.9%. 2. The mean values of RFA in control, group 2 and groups 3 showed the similar values, but there was no significant difference among groups. 3. Histomorphometric evaluation demonstrated significantly higher bone-to-implant contact ratio in group 2 at 3 and 4 weeks after implant placement than other groups (p<0.05), but there was no significant difference among groups at 6weeks after implant placement.

상하악 대구치 부위에서 넓은 직경 임플란트의 생존율에 대한 후향적 연구 (Retrospective Study of Wide-Diameter Implants in Maxillary & Mandibular Molar regions)

  • 박경아;정철웅;류경호;박광범;김영준
    • Journal of Periodontal and Implant Science
    • /
    • 제37권4호
    • /
    • pp.825-838
    • /
    • 2007
  • Endosseous implants are used in the treatment of various types of tooth loss, and numerous long-term studies have demonstrated the excellent reliability of this method of treatment. However, the increase of implant failure are associated with inadequate quality and/or height of bone. At the end of the 1980s, Wide(>3.75mm) implants were initially used for managing these difficult bone situations. The recommended indications for its use included poor bone quality, inadequate bone height. immediate placement in fresh extraction sockets, and immediate replacement of failed implants. At the 2000s, wider implants(6.0mm and 6.5mm) were used in a few studies. Although good clinical outcomes have been reported in recent years, there is still a controversy on this topic. Therefore, the purpose of this study was to estimate the survival rate of wide implants($6.0{\sim}8.0mm$) in molar regions, evaluating the clinical outcome. In this study, 1135 RBM surfaced wide implants($Rescue^{TM}$, MEGAZEN Co., Korea/595 maxillary, 540 mandibular) were placed in 650 patients(403 male, 247 female/age mean: $51.2{\pm}11.1$ years, range 20 to 83 years). Of the total, 68.3% were used to treat fully or partially edentulous situations, including single-tooth losses and 31.7% were placed immediately after teeth extraction or removal of failed implants, of which all were in the molar regions. Implant diameter and length ranged from 6.0 to 8.0mm and from 5.0 to 10.0mm respectively. The implants were followed for up to 42 months (mean: $14.6{\pm}9.5$ months). Of 1135 placed implants, 58 implants were lost. Among them, 53 implants were lost within 12 months after implant placement. The survival rate was 93.6% in the maxilla and 96.3% in the mandible, yielding an overall survival rate of 94.9%, for up to 42 months. As the result of Cox regression model, prosthetic type, sinus graft, and patient gender have an statistical significance on the implant survival rate in this study. This study suggests that the use of wide implants($6.0{\sim}8.0mm$) would provide a predictable treatment alternative in posterior areas.