• 제목/요약/키워드: RBM (resorbable blasting media)

검색결과 23건 처리시간 0.025초

Effect of implant surface microtopography by hydroxyapatite grit-blasting on adhesion, proliferation, and differentiation of osteoblast-like cell line, MG-63

  • Park, Sung-Jae;Bae, Sang-Bum;Kim, Su-Kyoung;Eom, Tae-Gwan;Song, Seung-Il
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제37권3호
    • /
    • pp.214-224
    • /
    • 2011
  • Objective: This study examined the potential of the in vitro osteogenesis of microtopographically modified surfaces, RBM (resorbable blasting media) surfaces, which generate hydroxyapatite grit-blasting. Methods: RBM surfaces were modified hydroxyapatite grit-blasting to produce microtopographically modified surfaces and the surface morphology, roughness or elements were examined. To investigate the potential of the in vitro osteogenesis, the osteoblastic cell adhesion, proliferation, and differentiation were examined using the human osteoblast-like cell line, MG-63 cells. Osteoblastic cell proliferation was examined as a function of time. In addition, osteoblastic cell differentiation was verified using four different methods of an ALP activity assay, a mineralization assay using alizarin red-s staining, and gene expression of osteoblastic differentiation marker using RT-PCR or ELISA. Results: Osteoblastic cell adhesion, proliferation and ALP activity was elevated on the RBM surfaces compared to the machined group. The cells exhibited a high level of gene expression of the osteoblastic differentiation makers (osteonectin, type I collagen, Runx-2, osterix). imilar data was represented in the ELISA produced similar results in that the RBM surface increased the level of osteocalcin, osteopontin, TGF-beta1 and PGE2 secretion, which was known to stimulate the osteogenesis. Moreover, alizarin red-s staining revealed significantly more mineralized nodules on the RBM surfaces than the machined discs. Conclusion: RBM surfaces modified with hydroxyapatite grit-blasting stimulate the in vitro osteogenesis of MG-63 cells and may accelerate bone formation and increase bone-implant contact.

Resorbable blasting media 및 산처리한 임플란트의 제거회전력에 생리식염수를 적시는 것이 미치는 영향 (On the effect of saline immersion to the removal torque for resorbable blasting media and acid treated implants)

  • 권재욱;조성암
    • 구강회복응용과학지
    • /
    • 제34권1호
    • /
    • pp.1-9
    • /
    • 2018
  • 목적: Resorbable blasting media (RBM) 표면처리 후 산처리한 티타늄 임플란트와 동일한 표면처리 후 생리식염수에 적신 티타늄 임플란트에서 생리식염수에 적신 경우 초기 골유착에 미치는 영향을 제거회전력 및 표면분석을 통해서 알아보고자 하였다. 연구 재료 및 방법: 대조군은 RBM 표면처리 후 산처리된 임플란트(RBM + HCl)이고, 실험군은 대조군과 동일한 표면처리 후 생리식염수에 2주간 적신 임플란트(RBM + HCl + Sal)이다. 토끼 10마리의 좌우측 경골에 각각 대조군 및 실험군 임플란트를 식립하고, 동시에 식립회전력(ITQ)을 측정하였다. 10일 후 임플란트 식립부위를 노출시켜 제거회전력(RTQ)을 측정하였다. 실험에 사용된 임플란트 시편의 표면분석을 위해 field emission-scanning electron microscopy (FESEM), energy dispersive X-ray Spectroscopy (EDS), 표면거칠기 측정 및 Raman 분광분석을 시행하였다. 결과: RBM 표면처리 및 산처리하여 생리식염수에 적신 티타늄 임플란트에서 대조군에 비해 높은 제거회전력을 나타냈으며, 통계적으로 유의미한 값을 보였다(P = 0.014 < 0.05). 표면거칠기는 실험군에서 더 높은 거칠기를 나타냈다. 결론: 티타늄 임플란트에 RBM 표면처리 및 산처리 후 생리식염수에 적신 것이 생리식염수를 적시지 않은 것 보다 초기 골유착을 향상시키는 것으로 생각된다.

Histologic analysis of resorbable blasting media surface implants retrieved from humans: a report of two cases

  • Jeong, Kyung-In;Kim, Young-Kyun;Moon, Sang-Woon;Kim, Su-Gwan;Lim, Sung-Chul;Yun, Pil-Young
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제42권1호
    • /
    • pp.38-42
    • /
    • 2016
  • The purpose of this study is to evaluate the degree of osseointegration of resorbable blasting media (RBM) surface implants retrieved from humans. Three implants in the mandibular molar region that were surface-treated with RBM were retrieved from two patients. The implants were used to manufacture specimens in order to measure the bone-implant contact (BIC) ratio. The BIC ratios of the three implants were found to be an average of $69.0%{\pm}9.1%$. In conclusion, that RBM surface implants are integrated into the host environment with histological significance and the BIC ratio of the RBM surface-treated implant was not significantly different from that of other surface-treated implants.

Comparative Study of the Early Loading of Resorbable Blasting Media and Sandblasting with Large-grit and Acid-etching Surface Implants: A Retrospective Cohort Study

  • Kim, Sung-Beom;Kim, Young-Kyun;Kim, Su-Gwan;Oh, Ji-Su;Kim, Byung-Hoon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제36권6호
    • /
    • pp.247-252
    • /
    • 2014
  • Purpose: This study compares the prognosis (the survival rate and marginal bone loss) of resorbable blasting media (RBM) surface implants and sandblasting with large-grit and acid-etching (SLA) surface implants in the early loading. Methods: This study targeted 123 patients treated by implants installation from January 2008 to March 2010. The loading was initiated in the maxilla within three to four months and in the mandible within one to two months. The types of restoration were single crown and fixed partial prosthesis. Those functioned over one year. The implants were classified by the surface of implants as Group 1: RBM surface (GS III; OSSTEM, Busan, Korea) and, Group 2: SLA surface (Superline; Dentium, Seoul, Korea). The groups were categorized by maxilla and mandible and compared by survival rate, marginal bone loss through clinical records evaluation, and radiographic measurements. Results: The marginal bone loss in the maxilla was $0.14{\pm}0.34mm$ (Group 1) and $0.30{\pm}0.37mm$ (Group 2), a statistically significant difference (P<0.05). In the mandible those were $0.28{\pm}0.54mm$ (Group 1) and $0.20{\pm}0.33mm$ (Group 2), not significant (P>0.05). There was no significant difference of marginal bone loss between maxilla and mandible by groups. During observation there was no implant failure, a survival rate of 100%. Conclusion: Both surfaces showed an excellent survival rate, and the marginal bone loss was not substantial.

RBM 표면 테이퍼형태 임프란트의 단기간 후향적 임상 평가 (Short-Term Retrospective Clinical Study of Resorbable Blasting Media Surface Tapered Implants)

  • 김수연;김영균
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제33권2호
    • /
    • pp.149-153
    • /
    • 2011
  • Purpose: The aim of the present study was to evaluate the clinical outcome of resorbable blasting media surface tapered implant. Methods: 169 Osstem$^{(R)}$ GS III dental implants in 73 patients who received implant treatments at Seoul National University Bundang Hospital, were included in this study. The incidence of biological and prosthetical complications has been carefully analysed for each implant. Results: The short-term implant survival rate was 97.63%, success rate 94.7%. The prevalence of biological complications was 15.38% and the prevalence of prosthetic complications was 13.04%. The mean value of crestal bone loss was $0.28{\pm}0.57$ mm. The relationship between loading periods and marginal bone loss was small and not statistically significant. In mandible, marginal bone loss was larger than in maxilla, no statistically significant. Also, length and diameter of implant had no relationship with marginal bone loss. Conclusion: We suggest that this implant system could achieve successful and stable results.

표면처리가 교정용 미니 임플랜트의 식립수직력과 토크에 미치는 영향 (Influence of surface treatment on the insertion pattern of self-drilling orthodontic mini-implants)

  • 김상철;김호영;이상재;김철문
    • 대한치과교정학회지
    • /
    • 제41권4호
    • /
    • pp.268-279
    • /
    • 2011
  • 본 연구의 목적은 유지력을 높이기 위하여 교정용 미니 임플랜트에 표면처리를 시행하되 식립 과정의 용이성에 영향을 주지 않는 표면처리 방법을 찾기 위함이다. 교정용 미니 임플랜트를 etching, resorbable blasting media (RBM), 상부 나사산 부위만 RBM 처리를 한 hybrid 등의 3가지 방법으로 표면처리한 후 machined (표면 미처리)군과 비교하였다. 주사전자현미경과 표면 거칠기 측정기로 표면 거칠기를 비교하였으며, driving torque tester를 이용해 실험용 인공골에 교정용 미니 임플랜트를 식립하여, 식립 토크(rotational torque)와 수직력(vertical loading)의 식립 패턴을 비교하였다. Machined surface군과 비교하여 acid etching군에서는 표면 거칠기(Ra 값)가 크지 않았으나 ($p$ > 0.05), RBM군이나 hybrid군에서 표면 거칠기(Ra 값)가 유의하게 컸다 ($p$ < 0.05). 최종 식립 토크는 모든 표면처리군에서 machined군보다 컸다 ($p$ < 0.05). 최대 식립수직력은 hybrid군이 machined군이나 etched군보다 유의하게 작았으며 ($p$ < 0.05), RBM군이 가장 컸다 ($p$ < 0.05). 교정용 미니 임플랜트의 유지력을 높이기 위하여 보철용 임플랜트와 같은 방법으로 전면 표면처리를 하면 self drilling type 고유의 골 삭제기능이 저하될 수 있다. 그러나 cutting edge 일정 부위를 제외하며 적절하게 조절된 표면처리를 하면 골 삭제 능력의 큰 저하 없이 용이한 식립이 가능할 것으로 보인다.

마그네슘 이온주입 임플란트의 뒤틀림 제거력에 관한 연구 (Removal Torque of Mg-ion Implanted Clinical Implants with Plasma Source Ion Implantation Method)

  • 김보현;김대곤;박찬진;조리라
    • 구강회복응용과학지
    • /
    • 제25권1호
    • /
    • pp.41-52
    • /
    • 2009
  • 골과 임플란트의 기계적인 결합을 증진시키기 위한 다양한 시도가 이루어졌으며, 최근에는 불소 부식법, 양극산화법, 이온주입법 등 생화학적인 골유착을 유도할 수 있는 임플란트의 표면개질이 관심의 대상이 되고 있다. 본 연구는 플라즈마 상태의 이온을 임플란트 표면에 주입하여 이온 피막을 형성하는 방법(plasma source ion implantion, PSII)으로 표면을 개질한 임플란트에 대한 골반응을 흡수성 재료로 블라스팅 처리(resorbable blasting media, RBM)된 임플란트를 대조군으로 하여 평가하고 이온 주입량을 달리하여 비교한 결과를 알아보고자 하였다. 12마리의 뉴질랜드 가토의 경골에 대조군인 RBM 임플란트와 Mg이온 주입량을 달리한 Mg이온주입 임플란트 3개씩을 식립하고 공진주파수를 측정하였으며 6주 후 48개 임플란트의 뒤틀림 제거력과 공진주파수를 측정하였다. 반복측정이 있는 분산분석을 이용하여 95% 유의수준으로 통계적 유의성을 확인하여 다음과 같은 결과를 얻었다. 1. 각 임플란트간 공진주파수의 차이는 없었으나 군에 관계없이 식립 시에 비해 6주 후의 공진주파수는 증가하였다. 2. 초기 낮은 공진주파수를 나타낸 임플란트군의 공진주파수 증가량이 큰 경향을 나타내었다. 3. 이온잔존량 9.4%인 Mg 1 임플란트가 다른 임플란트 보다 통계적으로 유의하게 큰 뒤틀림제거력을 보였다. 이상의 결과를 종합하여 가장 우수한 골반응을 나타내는 이온주입량을 알 수 있었으며 이러한 이온주입 임플란트가 임상적으로 뛰어난 효능을 보이는 RBM 표면에 비해서도 생물학적 골반응이 더 우수하다는 것을 입증하는 결과라 할 수 있다.

RBM 표면 임플란트와 산부식 표면 임플란트의 3년 생존율에 대한 비교 연구 (3-Year Survival Analysis of RBM and Acid-Etched Surface Implants)

  • 윤대웅;김문섭;장한성;진수영;마득현;정경달;박현춘;김희중;김학균
    • 구강회복응용과학지
    • /
    • 제27권4호
    • /
    • pp.393-403
    • /
    • 2011
  • 이 연구의 목적은 임상적으로 사용되는 RBM과 산부식 임플란트의 3년 생존율을 비교, 분석하기 위한 것이다. 총 152개의 RBM 임플란트를 식립하였고, 이 중 1개의 임플란트에서 실패가 발생하였는데, 원인은 식립체의 파절이었다. 또한 총 152개의 산부식 표면 임플란트를 식립하였는데, 이 중 7개의 임플란트에서 실패를 하였으며, 원인으로는 과열, 감염, 초기고정 불량 등이었다. RBM 임플란트의 생존율은 99.34%, 산부식 임플란트의 생존율은 95.39%로 두 가지 임플란트 모두 양호한 생존율을 보였으나, RBM 임플란트에서 다소 높은 생존율을 나타내었다.

Bone cutting capacity and osseointegration of surface-treated orthodontic mini-implants

  • Kim, Ho-Young;Kim, Sang-Cheol
    • 대한치과교정학회지
    • /
    • 제46권6호
    • /
    • pp.386-394
    • /
    • 2016
  • Objective: The objective of the study was to evaluate the practicality and the validity of different surface treatments of self-drilling orthodontic mini-implants (OMIs) by comparing bone cutting capacity and osseointegration. Methods: Self-drilling OMIs were surface-treated in three ways: Acid etched (Etched), resorbable blasting media (RBM), partially resorbabla balsting media (Hybrid). We compared the bone cutting capacity by measuring insertion depths into artificial bone (polyurethane foam). To compare osseointegration, OMIs were placed in the tibia of 25 rabbits and the removal torque value was measured at 1, 2, 4, and 8 weeks after placement. The specimens were analyzed by optical microscopy, scanning electron microscopy (SEM), and energy dispersive X-ray spectroscopy (EDS). Results: The bone cutting capacity of the etched and hybrid group was lower than the machined (control) group, and was most inhibited in the RBM group (p < 0.05). At 4 weeks, the removal torque in the machined group was significantly decreased (p < 0.05), but was increased in the etched group (p < 0.05). In the hybrid group, the removal torque significantly increased at 2 weeks, and was the highest among all measured values at 8 weeks (p < 0.05). The infiltration of bone-like tissue surface was evaluated by SEM, and calcium and phosphorus were detected via EDS only in the hybrid group. Conclusions: Partial RBM surface treatment (hybrid type in this study) produced the most stable self-drilling OMIs, without a corresponding reduction in bone cutting capacity.

Prospective Clinical Trial of Survival Rate for Two Different Implant Surfaces Using the Osstem(R) SS II Non-submerged Implant System in Partially Edentulous Patients

  • Kim, Su-Gwan;Lim, Chae-Su;Oh, Min-Seok;Park, Jin-Sung;Kim, Seo-Yoon;Seol, Ka-Young
    • Journal of Korean Dental Science
    • /
    • 제2권2호
    • /
    • pp.35-41
    • /
    • 2009
  • Objective : This study sought to investigate the clinical survival rate of two implants with different surfaces: resorbable blasting media (RBM)-treated and calcium metaphosphate (CMP)-coated implant. Study design : SSII non-submerged implants (Osstem, Seoul, Korea) were placed in a total of 48 patients with mean age of 38.8. At least 31 patients in the experimental group had a CMP-coated implant, and 1 patient in the control group received a, RBM surface implant. The evaluation period was between April 2006 and December 2007. Radiographs, periotest, clinical periodontal examination, and prosthetic adjustment and occlusion were used. Results : The survival rate of the experimental and control groups after 1 year was 97.2% and 100%, respectively. The Wald confidence interval reported for the experimental group was not inferior to the control group. Conclusion : No significant differences were found between the RBM and CMP groups. The observed data suggest that CMP-coated methods can provide favorable clinical results for the functioning and healing of dental implants.

  • PDF