• Title/Summary/Keyword: RBCs

Search Result 116, Processing Time 0.023 seconds

Micro-imaging techniques for evaluation of plastic microfluidic chip

  • Kim, Jung-Kyung;Hyunwoo Bang;Lee, Yongku;Chanil Chung;Yoo, Jung-Yul;Yang, Sang-Sik;Kim, Jin-Seung;Park, Sekwang;Chang, Jun-Keun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.1 no.4
    • /
    • pp.239-247
    • /
    • 2001
  • The Fluorescence-Activated Cell Sorter (FACS) is a well-established instrument used for identifying, enumerating, classifying and sorting cells by their physical and optical characteristics. For a miniaturized FACS device, a disposable plastic microchip has been developed which has a hydrodynamic focusing chamber using soft lithography. As the characteristics of the spatially confined sample stream have an effect on sample throughput, detection efficiency, and the accuracy of cell sorting, systematic fluid dynamic studies are required. Flow visualization is conducted with a laser scanning confocal microscopy (LSCM), and three-dimensional flow structure of the focused sample stream is reconstructed from 2D slices acquired at $1\mutextrm{m}$ intervals in depth. It was observed that the flow structure in the focusing chamber is skewed by unsymmetrical velocity profile arising from trapezoidal cross section of the microchannel. For a quantitative analysis of a microscopic flow structure, Confocal Micro-PIV system has been developed to evaluate the accelerated flow field in the focusing chamber. This study proposes a method which defines the depth of the measurement volume using a detection pinhole. The trajectories of red blood cells (RBCs) and their interactions with surrounding flow field in the squeezed sample stream are evaluated to find optimal shape of the focusing chamber and fluid manipulation scheme for stable cell transporting, efficient detection, and sorting

  • PDF

Hematological analysis of the Korean native cattle (Hanwoo) according to the period and method of grazing

  • Choe, Changyong;Jung, Young-Hun;Do, Yoon Jung;Kang, Hee-Sung;Yoo, Jae-Gyu;Kim, Chan-Lan;Kim, Ui-Hyung;Song, Ru-hui;Park, Jinho
    • Korean Journal of Veterinary Service
    • /
    • v.41 no.3
    • /
    • pp.191-196
    • /
    • 2018
  • Blood tests have been used to develop treatment plans, such as disease diagnosis, treatment effect, and prognosis determination in livestock. The present study examined changes in the blood count, including RBCs, WBCs, and platelets, before and after grazing among the Korean native cattle grazing from spring to autumn. The study compared the blood count of livestock group (A, n=34) that returned from the rangeland to cowshed every evening and livestock group (B, n=21) that were not returned from the rangeland to cowshed every evening during the grazing period. Hematological parameters such as RBC, hemoglobin, hematocrit, MCV, and WBC, neutrophil, eosinophil, monocyte, and lymphocyte were determined using a blood cell analyzer. Livestock group (A) showed significant differences in the values of RBC, MCV, MCHC, WBC, EOS, and LYM. Livestock group (B) showed significant differences in the values of RBC, Hb, HCT, MCV, MCH, PLT, NEU, and BAS. In particular, the RBC count decreased after grazing when compared with that before grazing. Compared with that before grazing, low RBC count was maintained from the first to fifth month of grazing. The WBC count increased from the fourth month of grazing, whereas the EOS count increased from the second month of grazing. These results suggest that the values of RBC and WBC vary before and after grazing, and also with the grazing period. Furthermore, it is necessary to develop a detailed feeding management based on these values of blood analysis for livestock that are raised continuously in the rangeland.

pH-dependent Cytotoxicity of a Peptide Toxin, Tolaasin (펩티드 독소 Tolaasin에 의한 세포독성의 pH 의존성)

  • Kim, Sung-Tae;Choi, Tae-Keun;Kim, Young-Kee
    • Applied Biological Chemistry
    • /
    • v.50 no.4
    • /
    • pp.257-261
    • /
    • 2007
  • Tolaasin, a peptide toxin produced by Pseudomonas tolaasii, causes a serious disease on the cultivated mushrooms, known as brown blotch disease. Hemolysis using red blood cells was designed to measure the cytotoxicity of tolaasin molecules. Since tolaasin has two amine groups near the C-terminus, its membrane binding will be dependent on the ionic states of the amine groups. When the tolaasin peptide was titrated, its titration curve indicated the presence of titratable amine(s) at pH ranges from 7.0 to 9.6. When the pH-dependence of tolaasin-induced hemolysis was measured at various pHs, hemolysis was more efficient at alkaline pHs. In order to measure the membrane binding activity of tolaasin at different pHs, RBCs were incubated with tolaasin molecules for short time periods and washed out with fresh buffer. Because of the tolaasin binding during the preincubation period, fast hemolyses were observed at pH 8 or higher. These results imply that non-charged or less positively charged states of tolaasin molecules easily bind to membrane and show high hemolytic activity.

Characteristics and Phenol Wastewater Treatment of Aerobic Biofilm Reactor Used Rhodococcus sp. EL-GT and Sludge (Rhodococcus sp. EL-GT와 Sludge를 이응한 호기성 생물막 반응기의 특성 및 페놀 처리)

  • Park, Geun-Tae;Won, Seong-Nae;Cho, Sun-Ja;Son, Hong-Joo;Lee, Geon;Lee, Sang-Joon
    • Journal of Environmental Science International
    • /
    • v.11 no.6
    • /
    • pp.553-560
    • /
    • 2002
  • The research was performed to compare to the biofilm characteristics and phenol removal efficiency in RBCs(Rotating Biological Contactor) using Rhodococcus sp. EL-GT(single population) and activated sludge(mixed population) as inoculum. Both reactors showed similar tendency on variations of dry weight, thickness and dry density of biofilm. However, the growth of biofilm thickness in 3 and 4 stage of single population reactor has sustained longer than that of the mixed population reactor. Unlike the mixed population reactor, the dry density of biofilm in the single population reactor had a difference between 1, 2 stage and 3, 4 stage. The single population reactor was stably operated without the decrease of phenol removal efficiency in the range of pH 6 ~ 9 and 15mM phenol was completely degraded in these pH ranges. But in case of the mixed population reactor, the phenol degradability was dramatically decreased at over 5mM phenol concentration because of the overgrowth and detachment of its biofilm.

Chromium concentration and half-life in rats biological samples after intravenous administration of soluble trivalent and hexavalent chromium compounds (흰쥐에 정맥 주사한 수용성 크롬의 분포 및 배설)

  • Kim, Yong-Lae;Kim, Chy-Nyon;Roh, Jaehoon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.11 no.1
    • /
    • pp.9-16
    • /
    • 2001
  • Chromium exposure can be in the forms of environmental pollution and occupational exposure. The harmful effects of chromium on the body greatly differ depending on its valence or solubility. Accordingly, the recommended permissible exposure limit for each chromium compound is different. This study investigated the increase or decrease of distribution and excretion of total chromium exposed simultaneously the soluble Cr+6 and Cr+3 compounds. There were no difference of total chromium concentration in plasma, red bloods cells, urine, organs between simultaneously injected and individually injected soluble Cr+6 and Cr+3 compound. The chromium clearances in urine also showed that there were two phases in the two groups. In the first phase, biological half lives of the total chromium of the two groups have been similar within 24 hr., but in the second phase, biological half life of the group injected simultaneously was 62.7 hr. and was less than that of the other group's 188.3 hr. The average concentration of total chromium in plasma was same with the control, and that of RBCs was $0.218nmol/m{\ell}$ and was slightly increased in comparison with $0.121nmol/m{\ell}$ of the control, which was not statistically significant. As a result, there were no differences of distribution and excretion of chromium between the group exposed simultaneously and the other group exposed separately the soluble Cr+6 and Cr+3 compounds. The biological half life of chromium of the former group in urine was less than that of the other group.

  • PDF

FAST Reappraisal: Cross-sectional Study (혈역학적으로 안정된 복부둔상환자에서 FAST의 유용성 평가)

  • Ha, Sang Hyun;Hong, Chong Kun;Lee, Jun Ho;Hwang, Seong Youn;Choi, Seong Hee
    • Journal of Trauma and Injury
    • /
    • v.25 no.3
    • /
    • pp.67-71
    • /
    • 2012
  • Purpose: Focused Assessment with Sonography for Trauma (FAST) provides an important initial screening examination in adult trauma patients. However, due to its low sensitivity, FAST is not a replacement for computed tomography (CT) in hemodynamically stable trauma patients. The aim of this study was to determine the test characteristics of FAST in adult, hemodynamically stable, blunt abdominal trauma patients by using a critical action as a reference standard. Methods: The medical records for FAST examination at a single hospital from January 2009 to February 2011 were retrospectively reviewed. The inclusion criterion was isolated, hemodynamically stable, blunt abdominal trauma. Hemodynamically unstable patients or patients with penetrating injuries were excluded. The reference standard was the presence of a critical action, which was defined as one of the following: 1) operative intervention for a finding discovered on CT, 2) interventional radiology for bleeding, 3) transfusion of 2 or more packed RBCs, or 4) death at the emergency department. Results: There were 230 patients who met the inclusion criterion. There were 20 true positive, 206 true negative, 0 false positive, and 4 false negative results. The sensitivity and the specificity were 83% and 100%, respectively. Conclusion: Despite its low sensitivity for detecting any abnormal finding discovered on CT, negative FAST could aid to exclude critical action in hemodynamically stable, blunt abdominal trauma patients.

Fabrication of PDMS microlens for optical detection (광학적 검출을 위한 PDMS 마이크로렌즈의 제작)

  • Park, Se-Wan;Kim, Hyeon-Cheol;Chun, Kuk-Jin
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.4
    • /
    • pp.15-20
    • /
    • 2009
  • In a detection system based on laser light scattering, focusing an excitation laser beam into a focal point of a channel in a microfluidic chip is important for obtaining the highest excitation intensity, and consequently for obtaining a laser light scattering signal using a photodetector with a high efficiency. In this paper, we present a polydimethylsiloxane (PDMS) microfluidic chip consisting of an integrated PDMS microlens for cell detection based on laser light scattering. We fabricated PDMS microlens for optical detection system by simply putting down on PDMS chips. The PDMS microlens was fabricated by photoresist reflow and replica molding. This fabrication technique is simple and has an excellent property in terms of the microlens and a high-dimensional accuracy. The PDMS microlens integrated on the PDMS microfluidic chip has been verified to improve the laser intensity, and accordingly, the signal-to-noise ratio and sensitivity of laser light scattering detection for red blood cells(RBCs)

Role of Arbitrary Intensity Profile Laser Beam in Trapping of RBC for Phase-imaging

  • Kumar, Ranjeet;Srivastava, Vishal;Mehta, Dalip Singh;Shakher, Chandra
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.1
    • /
    • pp.78-87
    • /
    • 2016
  • Red blood cells (RBCs) are customarily adhered to a bio-functionalised substrate to make them stationary in interferometric phase-imaging modalities. This can make them susceptible to receive alterations in innate morphology due to their own weight. Optical tweezers (OTs) often driven by Gaussian profile of a laser beam is an alternative modality to overcome contact-induced perturbation but at the same time a steeply focused laser beam might cause photo-damage. In order to address both the photo-damage and substrate adherence induced perturbations, we were motivated to stabilize the RBC in OTs by utilizing a laser beam of ‘arbitrary intensity profile’ generated by a source having cavity imperfections per se. Thus the immobilized RBC was investigated for phase-imaging with sinusoidal interferograms generated by a compact and robust Michelson interferometer which was designed from a cubic beam splitter having one surface coated with reflective material and another adjacent coplanar surface aligned against a mirror. Reflected interferograms from bilayers membrane of a trapped RBC were recorded and analyzed. Our phase-imaging set-up is limited to work in reflection configuration only because of the availability of an upright microscope. Due to RBC’s membrane being poorly reflective for visible wavelengths, quantitative information in the signal is weak and therefore, the quality of experimental results is limited in comparison to results obtained in transmission mode by various holographic techniques reported elsewhere.

The Impact of Trauma Center Establishment on Laparotomy Patterns and Outcomes in Severe Hemoperitoneum Patients

  • Lee, Min A;Lee, Jungnam;Chung, Min;Lee, Giljae;Park, Jaejeong;Choi, Kangkook;Yoo, Byung Chul
    • Journal of Trauma and Injury
    • /
    • v.30 no.1
    • /
    • pp.6-11
    • /
    • 2017
  • Purpose: The establishment of the trauma system has changed the quality of trauma care in many countries. As one of the first designated level I trauma centers in Korea, we hypothesized that there were changes in laparotomy patterns and subsequent survival rates after the center was established. Methods: This was a 5-year retrospective study of all severe hemoperitoneum patients who were transfused with more than 10 units of packed red blood cells (RBCs) within 24 h of hospitalization. Variables related to trauma were collected throughout the study period, and the patients admitted before (period 1) and after (period 2) the establishment of a trauma center were compared. Results: Forty-five patients were managed from January 2009 to March 2015. The baseline patient characteristics of the two groups, including age, Injury Severity Score, blood pressure, and hemoglobin levels, were similar. The time to the operating room (OR) was $144.3{\pm}51.5$ min (period 1) and $79.9{\pm}44.1$ min (period 2) (p<0.0001). Damage control surgery (DCS) was performed in 17% of patients during period 1 and in 73% during period 2. The number of actual survivors (n=10) was higher than expected (n=8) in period 2. Conclusion: This is the first study analyzing the impact of a trauma center on the management of specific injuries, such as severe hemoperitoneum, in patients in Korea. During the study, the time to OR was shortened and DCS was used to a greater extent as a surgical procedure.

Hemodynamic Analysis of Blood Flows in the Extraembryonic Blood Vessels of Chicken Embryos (유정란 태아외부혈관 내부 혈액유동에 대한 혈류역학적 연구)

  • Lee, Jung-Yeop;Lee, Sang-Joon
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.6-9
    • /
    • 2008
  • Analyzing the characteristics of blood flow in the blood vessels is very important to diagnose the circulatory diseases. In order to investigate the hemodynamic characteristics in vivo, the measurements of blood flows inside the extraembryonic arterial and venous blood vessels of chicken embryos were carried out using an in vivo micro-PIV technique. The circulatory diseases are closely related with the formation of abnormal hemodynamic shear stress regions, thereby it is important to get blood velocity and vessel's morphological information according to the vessel configuration and the flow conditions. In this study, the flow images of RBCs in blood vessels were obtained using a high-speed CMOS camera with a spatial resolution of approximately 14.6${\mu}$m${\times}$14.6${\mu}$m in the whole circulation network of blood vessels. The blood flows in the veins and arteries show steady laminar and unsteady pulsatile flow characteristics, respectively. The mean blood flows merged (in veins) and bifurcated (in arteries) smoothly into the main blood vessel and branches, respectively, without any flow separation or secondary flow which accompanying large variation of shear stress. Vorticity was high in the inner regions for both types of vessels, where the radius of curvature varied greatly. The instantaneous flows in the arterial blood vessels showed noticeable pulsatility due to the heart beat, and the main features of the velocity waveforms, including pulsatile shape, retrograde flow, mean velocity, maximum velocity and pulsatile frequency, were significantly dependent on the pulsatile condition which dominates the arterial blood flow. In near future, these in vivo experimental results of blood flow measured in various extraembryonic blood vessels would be very useful to understand the hemodynamic characteristics of human blood flows and various blood flow researches for clinically useful hemodynamic discoveries as well.

  • PDF