• Title/Summary/Keyword: RAW data

Search Result 2,582, Processing Time 0.029 seconds

Software-based Simple Lock-in Amplifier and Built-in Sound Card for Compact and Cost-effective Terahertz Time-domain Spectroscopy System

  • Yu-Jin Nam;Jisoo Kyoung
    • Current Optics and Photonics
    • /
    • v.7 no.6
    • /
    • pp.683-691
    • /
    • 2023
  • A typical terahertz time-domain spectroscopy system requires large, expensive, and heavy hardware such as a lock-in amplifier and a function generator. In this study, we replaced the lock-in amplifier and the function generator with a single sound card built into a typical desktop computer to significantly reduce the system size, weight, and cost. The sound card serves two purposes: 1 kHz chopping signal generation and raw data acquisition. A unique software lock-in (Python coding program to eliminate noise from raw data) method was developed and successfully extracted THz time-domain signals with a signal-to-noise ratio of ~40,000 (the intensity ratio between the peak and average noise levels). The built-in sound card with the software lock-in method exhibited sufficiently good performance compared with the hardware-based method.

Microbiological Evaluation of Chilled Freshes Raw-fish Manufacturers before and after HACCP System Establishment (싱싱회류 생산업체의 HACCP 시스템 구축 전 후의 미생물학적 평가)

  • 박완희;이성학;정덕화
    • Journal of Food Hygiene and Safety
    • /
    • v.19 no.2
    • /
    • pp.74-83
    • /
    • 2004
  • Raw-fish food contains a lot of moisture and is a high-protein food. It is a first-stage processed food taking a lot of manual work. Therefore, it is classified as a PHF food, very liable to cause a bacterial food-poisoning. But its manufacturers are usually small-sized and a systematic sanitation management is difficult to expect. But the manufacturer participating in this study produces chilled fresh raw-fish food. Fish are sliced into two fillets, which are packaged under vacuum, kept and distributed in refrigerators, and sold within a day. It is a newly-developed kind of raw-fish food, and a more improved kind of raw-fish food making possible a systematic sanitation management. The HACCP (Hazard Analysis and Critical Control Point) is a systematic and continuous process-control method which is very efficient for controling food sanitation and reducing the expenses. A new HACCP model has been developed to be applied to a large-sized chilled fresh raw-fish food manufacturer. To ascertain its efficiency, the baterial examination was done to its workplace and products. The significance test was done on its data by "SPSS 12.0 for Window" and "Mann-Whitney U Test". The numbers of bacteria on its final products were significantly different in flatfish and porgy. The number of bacteria tended to decrease in each time-differential sampling (P<.00l). The final food products showed no food-poisoning bacteria in all the time-differential tests and in all the samplings, which proves that the CCP of the HACCP system is under control. After the SSOP program was applied, no pathogenic bacteria were found in the work-place, and the kinds and numbers of bacteria decreased. The numbers of general bacteria and colon bacilli also showed a significant difference from those before the SSOP program in the filleting board (P<.05), in the skinning board (P<.0l), in the neck-removing knife (P<.05), and in the filleting knife (P<.01). The working equipments, periodically disinfected, also showed a significant difference in sanitary conditions (in the dehydrator, P<.05). The number of bacteria found on the food-touching surface was within the standard (below 500/l00 cm$^2$) After the SSOP program was applied, the general bacteria and colon bacilli were not found. The quality of water used in the food processing was also within the standard. The numbers of bacteria falling from the air in the work-place were negligible in all the samplings (<30CFU/l000ι). The staphylococci and fungi were not found.

Composition of effective monitoring system using an interpolation (보간법을 이용한 효율적인 모니터링 시스템 구성)

  • Lee, Sang-Hyeok;Kang, Feel-Soon;Jung, Da-Hun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.10a
    • /
    • pp.235-238
    • /
    • 2007
  • This paper presents an efficient data storage and reconstruction method in data acquisition and processing of monitoring system. The proposed method extracts minimum data using an interpolation from raw data which are acquired from a target system. The algorithm for data acquisition and reconstruction is based on Cubic Hermite interpolation. To verify the validity of the proposed scheme, we presents simulation results and it is applied to a monitoring system for grid-connected photovoltaic power generation system to prove the high-performance of the proposed method.

  • PDF

Evaluation of Recent Data Processing Strategies on Q-TOF LC/MS Based Untargeted Metabolomics

  • Kaplan, Ozan;Celebier, Mustafa
    • Mass Spectrometry Letters
    • /
    • v.11 no.1
    • /
    • pp.1-5
    • /
    • 2020
  • In this study, some of the recently reported data processing strategies were evaluated and modified based on their capabilities and a brief workflow for data mining was redefined for Q-TOF LC-MS based untargeted metabolomics. Commercial pooled human plasma samples were used for this purpose. An ultrafiltration procedure was applied on sample preparation. Sample set was analyzed through Q-TOF LC/MS. A C18 column (Agilent Zorbax 1.8 µM, 50 × 2.1 mm) was used for chromatographic separation. Raw chromatograms were processed using XCMS - R programming language edition and Isotopologue Parameter Optimization (IPO) was used to optimize XCMS parameters. The raw XCMS table was processed using MS Excel to find reliable and reproducible peaks. Totally 1650 reliable and reproducible potential metabolite peaks were found based on the data processing procedures given in this paper. The redefined dataset was upload into MetaboAnalyst platform and the identified metabolites were matched with 86 metabolic pathways. Thus, two list were obtained and presented in this study as supplement files. The first list is to present the retention times and m/z values of detected metabolite peaks. The second list is the metabolic pathways related with the identified metabolites. The briefly described data processing strategies and dataset presented in this study could be beneficial for the researchers working on untargeted metabolomics for processing their data and validating their results.

System Phase Noise Spectrum of the Transmission and Receiving System for COMS Sensor Data (통신해양기상위성 센서 데이터 송수신 시스템의 시스템 위상 잡음 스펙트럼)

  • Kim, Young-Wan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.7
    • /
    • pp.1247-1253
    • /
    • 2007
  • The system phase noise spectrum distribution for COMS sensor data transmitter and receiver system was proposed in this paper. On the basis of the analyzed design parameter to reduce the phase noise effect in a receiver, the optimal system phase noise were proposed for raw, IRIT and HRIT data transmission that are sensor data, respectively. The proposed system phase noise provides the qualified transmission performance of sensor data and reduces the performance degradation due to phase noise generating in the transmission channel. Also the system phase noise spectrums are utilized in the design of frequency generation source for sensor data transmission and receiver system.

Design and Implementation of Real-Time Mobile Remicon Quality Management Program for Field Response of Remicon mixer (레미콘 배합의 현장 즉시 대응을 위한 실시간 모바일 레미콘 품질 관리 프로그램 설계 및 구현)

  • Kim, Suyeon
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.2
    • /
    • pp.111-117
    • /
    • 2019
  • In this paper, we propose a mobile remicon quality management system to enable inspection and correspondence with a smart phone in the field check of remicon. We also proposed a real-time slump data processing part to digitize field inspection and XML formats for data exchange with the server. We used the smart phone to transmit real-time image about field inspection of remicon and judged the error at the same time. By doing this, we shared the situation of the remicon products in the field and the head office. Based on the actual results, the development technology is used to determine whether the product is abnormal or not, and to provide appropriate information to the company and the site. Based on the analysis of raw material quality data, it is possible to present real time optimal blending ratio according to raw material import with raw material management data, which is the biggest problem of the ready mixed concrete industry.

Continued image Sending in DICOM of usefulness Cosideration in Angiography (혈관조영술에서 동영상 전송의 유용성 고찰)

  • Park, Young-Sung;Lee, Jong-Woong;Jung, Hee-Dong;Kim, Jae-Yeul;Hwang, Sun-Gwang
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.9 no.2
    • /
    • pp.39-43
    • /
    • 2007
  • In angiography, the global standard agreements of DICOM is lossless. But it brings on overload and takes too much store space in DICOM sever. Because of all those things we transmit images which is classified in subjective way. But this cause data loss and would be lead doctors to make wrong reading. As a result of that we try to transmit continued image (raw data) to reduce those mistakes. We got angiography images from the equipment(Allura FD20-Philips). And compressed it in two different methods(lossless & lossy fair). and then transmitted them to PACS system. We compared the quality of QC phantom images that are compressed by different compress method and compared spatial resolution of each images after CD copy. Then compared each Image's data volume(lossless & lossy fair). We measured spatial resolution of each image. All of them had indicated 401p/mm. We measured spatial resolution of each image after CD copy. We got also same conclusion (401p/mm). The volume of continued image (raw data) was 127.8MB(360.5 sheets on average) compressed in lossless and 29.5MB(360.5 sheets) compressed in lossy fair. In case of classified image, it was 47.35MB(133.7 sheets) in lossless and 4.5MB(133.7 sheets) in lossy fair. In case of angiography the diagnosis is based on continued image(raw data). But we transmit classified image. Because transmitting continued image causes some problems in PACS system especially transmission and store field. We transmit classified image compressed in lossless But it is subjective and would be different depend on radiologist. therefore it would make doctors do wrong reading when patients transfer another hospital. So we suggest that transmit continued image(raw data) compressed in lossy fair. It reduces about 60% of data volume compared with classified image. And the image quality is same after CD copy.

  • PDF

A Study on freedom of information in the Government 2.0 era (거버먼트 2.0 기반의 정보공개제도 개선방안에 대한 연구)

  • Kim, You-seung
    • The Korean Journal of Archival Studies
    • /
    • no.25
    • /
    • pp.197-231
    • /
    • 2010
  • The concept of Government 2.0 is spreading rapidly in many countries and is fundamentally changing existing freedom of information system which has passively responded to information demands. This study aims at discussing possible strategies for a new freedom of information system that is based on the Government 2.0 notion which presents revolutional approaches to public sector information's creation, management, and usage. For the purpose of the study, precedence studies and researches about both freedom of information system and Government 2.0 are analyzed. Furthermore, mutual relationships between them are discussed. Through this discussion, social and economic benefits from freedom of information systems which are based on Government 2.0 are explored. As a case study, Data.gov services in the US, the UK, and Australia which are recognised as a feasible plan to set up Government 2.0 are analyzed. Their three common characteristics- revaluating public sector information's reuse, establishing exclusive agencies, and providing raw data-are discussed. Then, various mashup services which use Data.gov services' raw data are also studied. Issues related to the freedom of information system in South Korea are examined. As a result, a policy framework for establishing Government 2.0 based freedom of Information system is discussed in terms of three aspects, law, technology and organization.

The Study about Accuracy Kinematic GPS Survey (정확한 동적 GPS 측량에 관한 연구)

  • 박운용;이종출;이인수;나종기
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2004.04a
    • /
    • pp.45-49
    • /
    • 2004
  • The Navstar Global Positioning System(GPS) is an advanced navigation satelite system for determination of position, velocity and time. It can provide three-dimensional positioning on a global basis, independent of weather, 24 hours per day. Test results show that the carrier phase and pseudorange corrections are suitable for a kinematic GPS system. Using these corrections are more effective than using raw GPS data, since fewer bits are required for transmission Additionally, the number of computation required at the rover is reduced when corrections, rather than raw measurement are transmitted

  • PDF

Activated Clay Maunfacturing Studies(II) Studies on the Estimation of Acid Clay Structure (活性白土에 關한 硏究(제II報) 酸性白土의 構造 推定에 關하여)

  • Son, Sun-Kwan;Ko, Myoung-Won
    • Journal of the Korean Chemical Society
    • /
    • v.14 no.4
    • /
    • pp.309-319
    • /
    • 1970
  • Composition of Acid Clay, the raw material for activated clay manufacturing, was investigated to develop useful data in deciding activation condition. Speculations on components and structure of activated clay were also made in order to see how included components of raw materials change during activation process. And a study was made on relations between structure of activated its adsorptivity. For this research, theremogravimetric analysis, X-ray differaction analysis and calculation of adsorptive index were carried out.

  • PDF