• Title/Summary/Keyword: RAMP4

Search Result 212, Processing Time 0.023 seconds

Evacuation Safety Evaluation According to Slope of the School Ramps

  • Choi, Chang-Jun;Kong, Ha-Sung
    • International journal of advanced smart convergence
    • /
    • v.10 no.1
    • /
    • pp.184-196
    • /
    • 2021
  • This study, in order to evaluate the safety of evacuation by comparing and analyzing the RSET according to the slope change of the ramp, which is a vertical evacuation route in case of fire in a high school building, Evacuation simulation was run the Pathfinder program changed the slope of the ramp to 10°, 15°, and 20° for each male students and female students. In the case of female students, it was analyzed that when the final RSET slope was 15°, 25.7 seconds were shorter than when 10°, and 4.2 seconds were shorter than when 20°. Male students also found that when the final RSET slope was 15°, 23.8 seconds were shorter than when 10°, and 5.4 seconds shorter than when 20°. It was analyzed that even if the number of participants was increased and the evacuation simulation was executed, the safety of evacuation could be improved when the slope of the slope is 15° as the RSET when the slope of the slope is 15° is shorter than that of 10° and 20°.

Tunneling Magnetoresistance of a Ramp-edge Type Junction With Si3N4 Barrier (Si3N4장벽층을 이용한 경사형 모서리 접합의 터널링 자기저항 특성)

  • Kim, Young-Ii;Hwang, Do-Guwn;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.12 no.6
    • /
    • pp.201-205
    • /
    • 2002
  • The tunneling magnetoresistance (TMR) of a ramp-edge type junction has been studied. The samples with a structure of NiO(60)/Co(10)/NiO(60)/Si$_3$N$_4$(2-6)/NiFe(10) (nm) were prepared by the sputtering and etched by the electron cyclotron (ECR) argon ion milling. Nonlinear I-V characteristics was obtained from a ramp-type tunneling junctions having the dominant difference between zero and +90 Oe perpendicular to the junction edge line. The voltage dependence of TMR was stable up to a bias volt of $\pm$10 V with a TMR ratio of about -10%, which may be very peculiar magnetic tunneling properties with asymmetric tunneling process between wedge Co pinned layer and NiFe free layer.

Capacity Analysis in the Ramp Junction of the Urban Freeway Connected with the Busan Port (부산항과 연계된 도시고속도로의 연결로 접속부내 용량특성분석에 관한 연구)

  • Kim, Tae Gon;Jeong, Young Hwan;Park, Jong Man;Ji, Seung Keun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.2D
    • /
    • pp.205-216
    • /
    • 2008
  • Urban freeway is defined as the roadway with 4 lanes or more which requires a high design criteria for handling a large capacity of vehicles rapidly as a high-speed exclusive roadway in the city. However, most of the urban freeways suffer from severe traffic congestion due to the increased traffic exceeding their capacities regardless of the morning and afternoon rushhours or the inbound and outbound directions. The purpose in this study is to collect and investigate the real-time traffic characteristics based on the ramp junction influence areas of the urban freeway connected with the Busan port, compare and analyze the traffic characteristic relationship for each lane within the ramp junction influence areas, and finally assess and suggest the optimal capacity for each lane within the ramp junction influence areas.

Determination of Minimum Spacing between Off-ramp Terminus and Intersection Considering the Influence of Adjacent Signalized Intersections (신호교차로 영향에 따른 도시고속도로 유출연결로 최소이격거리에 관한 연구)

  • Kim, Sang-Gu;Sim, Dae-Yeong;Heo, Du-Wan
    • Journal of Korean Society of Transportation
    • /
    • v.25 no.4
    • /
    • pp.79-87
    • /
    • 2007
  • The interchanges of urban freeways have many problems with traffic operation due to high off-ramp flows and frequent congestion at adjacent intersections. The flow exiting from off-ramps is affected by the operational status and traffic volume conditions of the nearest signalized intersection. As a result, off-ramp flow cannot exit and the queue backs up the freeway mainline when queues from the signalized intersection form up to the junction of the off-ramp and street. The spacing between an off-ramp and an adjacent intersection is likely to determine the traffic conditions at the adjacent intersection. However, the current design guidelines do not consider such a factor. This study is to develop a model calculating the spacing between off-ramps and adjacent intersections considering the signal, traffic, and road conditions. The variables affecting the model in this study are effective green time (g/C), volume-capacity ratio (v/c), the number of lanes, and off-ramp volume. Various scenarios are designed to represent the effects of the variables and the road networks are constructed using VISSIM, which is a common traffic micro-simulation software package. The queue length is derived from VISSIM and this length is considered as the recommended spacing between the off-ramp and the adjacent intersection. Through the simulation analysis, regression models are developed to calculate the queue length reflecting the various conditions such as signals, traffic, and road configurations. The developed model can be used to create road design guidelines to determine the location of off-ramps in the planning stage.

The Effects of Age and Walkway Type on Lower Extremities Kinematics in Elderly Women (보행로 형태가 여성노인들의 하지관절에 미치는 영향)

  • Woo, Byung-Hoon;Park, Yang-Sun
    • Korean Journal of Applied Biomechanics
    • /
    • v.25 no.3
    • /
    • pp.249-256
    • /
    • 2015
  • Objective : The purposes of this study was to perform a kinematical analysis on age and walkway types in elderly women subjects. Method : Forty subjects participated in the experiment (A1 group - age: $67.30{\pm}1.49yrs$, height: $153.81{\pm}4.47cm$, weight: $61.80{\pm}5.24kg$, A2 group - age: $71.70{\pm}1.10yrs$, height: $152.01{\pm}2.84cm$, weight: $59.69{\pm}7.34kg$, A3 group - age: $76.80{\pm}0.98yrs$, height: $150.16{\pm}6.08cm$, weight: $57.27{\pm}6.42kg$, A4 group - age: $81.80{\pm}0.60yrs$, height: $152.18{\pm}4.77cm$, weight: $55.80{\pm}7.78kg$). The study method adopted was the 3D analysis with six cameras. Ground type were classifed as gait pattern on flat, ascent and descent ramp. For the statistical analysis, the SPSS 21.0 was used to perform Repeated measured Two-way ANOVA. Results : In velocity of CM, there was faster movement on flat ground. When it came to the velocity of right toe, there was no significance in early mid-swing of right foot, but A4 was the slowest in late mid-swing of right foot on flat ground. In joint angle in left foot strike, the left hip joint and knee joint were more flexed in descent ramp, In addition left and right ankle joints were more plantarflexed in descent ramp, and left ankle joint was more plantarflexed in the over 75 yrs age groups. Conclusion : The higher age group were more flexed in lower body joints during descent ramp.

Tunneling Magnetoresistance of a Ramp Edge Junction with $SrTiO_3$ Barrier Layer ($SrTiO_3$ 장벽층을 이용한 경사형 모서리 접합의 터널링 자기저항 특성연구)

  • Lee, Sang-Suk;Kim, Young-Il;Hwang, Do-Guwn;Kim, Sun-Wook;Kungwon Rhie;Rhee, Jang-Roh
    • Proceedings of the Korean Magnestics Society Conference
    • /
    • 2002.12a
    • /
    • pp.174-175
    • /
    • 2002
  • A ramp-type tunneling magnetoresistance (TMR) junction having structure NiO(60 nm)/pinned Co(10 nm)MiO(60 nm)/barrier SrTiO$_3$(2-10 nm)/free NiFe(10 nm) with the 15 degree slope was investigated. We obtained nonlinear I(V) characteristics for ramp-type tunneling junctions that have distinctive difference with and without applied magnetic field. In the barrier SrTiO$_3$ thickness of 4 nm, the TMR was about 52% at a bias voltage of 50 mV. (omitted)

  • PDF

Free-strain solutions for two-dimensional consolidation with sand blankets under multi-ramp loading

  • Zan Li;Songyu Liu;Cuiwei Fu
    • Geomechanics and Engineering
    • /
    • v.35 no.4
    • /
    • pp.385-393
    • /
    • 2023
  • To analyze the consolidation with horizontal sand drains, the plane strain consolidation model under multi-ramp loading is established, and its corresponding analytical solution is derived by using the separation of variables method. The proposed solution is verified by the field measurement data and finite element results. Then, the effects of the loading mode and stress distribution on consolidation and dissipation of pore pressure are investigated. At the same time, the influence of hydraulic conductivity and thickness of sand blankets on soil consolidation are also analyzed. The results show that the loading mode has a significant effect on both the soil consolidation rate and generation-dissipation process of pore water pressure. In contrast, the influence of stress distribution on pore pressure dissipation is obvious, while its influence on soil consolidation rate is negligible. To guarantee the fully drained condition of the sand blanket, the ratio of hydraulic conductivity of the sand blanket to that of clay layer kd/kv should range from 1.0×104 to 1.0×106 with soil width varying from 100 m to 1000 m. A larger soil width correspondingly needs a greater value of kd/kv to make sure that the pore water can flow through the sand blanket smoothly with little resistance. When the soil width is relatively small (e.g., less than 100 m), the effect of thickness of the sand blanket on soil consolidation is insignificant. And its influence appears obvious gradually with the increase of the soil width.

Kinematic Analysis of Lower Extremities during Stairs and Ramp Climbing with Older Adults (노인의 계단과 경사로 오르기 동안 하지의 운동학적 분석)

  • Han, Jin-Tae;HwangBo, Gak
    • Korean Journal of Applied Biomechanics
    • /
    • v.19 no.3
    • /
    • pp.435-448
    • /
    • 2009
  • The purpose of this study was to investigate the kinemaitc gait parameter of lower extremities with different gait conditions(level walking, stairs, ramp) in old adults. Fourteen healthy older adults participated in this study and kinematic data were measured using 3D motion analysis system(Vicon, Oxford Metrics, England). Statistical analysis was used one-way ANOVA to know the difference of lower extremities angle at each gait phase with a different gait conditions. In sagittal plane, pelvic anterior tilt increased in stairs and ramp climbing and hip and knee flexion increased in stairs climbing but ankle dorsiflexion increased in ramp climbing. In frontal plane, pelvic was up in stairs and hip abduction and adduction more changed in stairs climbing than level walking. Knee varus and ankle inversion increased in stair climbing. In horizontal plane, pelvic internal rotation increased in stairs and ramp climbing and knee internal rotation increased in stairs climbing but ankle external rotation increased in stairs climbing. This results was shown that the stairs and ramp climbing changed the kinematic gait parameters of lower extremities in healthy old adults.

Nonlinear Kalman filter bias correction for wind ramp event forecasts at wind turbine height

  • Xu, Jing-Jing;Xiao, Zi-Niu;Lin, Zhao-Hui
    • Wind and Structures
    • /
    • v.30 no.4
    • /
    • pp.393-403
    • /
    • 2020
  • One of the growing concerns of the wind energy production is wind ramp events. To improve the wind ramp event forecasts, the nonlinear Kalman filter bias correction method was applied to 24-h wind speed forecasts issued from the WRF model at 70-m height in Zhangbei wind farm, Hebei Province, China for a two-year period. The Kalman filter shows the remarkable ability of improving forecast skill for real-time wind speed forecasts by decreasing RMSE by 32% from 3.26 m s-1 to 2.21 m s-1, reducing BIAS almost to zero, and improving correlation from 0.58 to 0.82. The bias correction improves the forecast skill especially in wind speed intervals sensitive to wind power prediction. The fact shows that the Kalman filter is especially suitable for wind power prediction. Moreover, the bias correction method performs well under abrupt weather transition. As to the overall performance for improving the forecast skill of ramp events, the Kalman filter shows noticeable improvements based on POD and TSS. The bias correction increases the POD score of up-ramps from 0.27 to 0.39 and from 0.26 to 0.38 for down-ramps. After bias correction, the TSS score is significantly promoted from 0.12 to 0.26 for up-ramps and from 0.13 to 0.25 for down-ramps.

The Effects of Inclined Foil Shape on Flow Characteristics in Air Foil Thrust Bearing Using CFD (에어 포일 스러스트 베어링의 탑포일 경사면 형상이 유동특성에 미치는 영향에 대한 수치해석 연구)

  • Baek, GeonWoong;Joo, Won-Gu;Mun, Hyeong Wook;Hwang, Sunghyen;Jeong, Sung-Yun;Park, Jung-Koo
    • Tribology and Lubricants
    • /
    • v.37 no.4
    • /
    • pp.117-124
    • /
    • 2021
  • In this study, we perform a 3D CFD conjugate analysis according to the shape of the foil ramp of the air foil thrust bearing, analyze the flow characteristics inside the bearing, and compare the results corresponding to the two shapes. Air has a lower viscosity than lubricating oil. Therefore, the thrust runner of the bearing must rotate at high speed to support the load. The gap between thrust runner and foil is significantly smaller than that of the oil bearing. Hence, it is crucial to analyze the complex flow characteristics inside the bearing to predict the complex flow inside the bearing and performance of the bearing. In addition, flow characteristics may appear differently depending on the ramp shape of the bearing foil, which may affect bearing performance. In this study, we numerically analyze the main flow path of air flowing into the bearing and the secondary flow path used for cooling the bearing using the commercial CFD software ANSYS CFX and compare the flow characteristics for straight and curved foil ramp shapes. Notably, there is a difference in the speed of the flowing air according to the shape of the ramp, which affects the bearing performance.