• Title/Summary/Keyword: R40

Search Result 5,816, Processing Time 0.033 seconds

Comparison of Condenser Characteristics using R410A and R22 under the Same Inlet Temperature Condition (동일한 유입온도조건에서 R410A와 R22 적용 응축기의 특성비교)

  • 김창덕;이진호
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.12
    • /
    • pp.1049-1059
    • /
    • 2003
  • R410A is considered as an alternative refrigerant to R22 for air conditioners. An experimental investigation was made to study the characteristics of the heat transfer and pressure drop for R410A flowing in a fin-and-tube heat exchanger used for commercial air-conditioning units. Experiments were carried out under the conditions of inlet refrigerant temperature of 6$0^{\circ}C$ and refrigerant mass flux varying from 150 to 250 kg/$m^2$s for refrigerant side. The inlet air has dry bulb temperature of 35$^{\circ}C$, relative humidity of 40% and air velocity varying from 0.68 to 1.6 m/s. Experiments show that air velocity decreased by 16% is needed for R410A than that of R22 for subcooling temperature of 5$^{\circ}C$, which resulted in air-side pressure drop decrease of 15% for R410A as compared to R22. As a consequence, in order to provide the same design condition of a condenser, the fan requires lower electric-power consumption with R410A than that with R22.

Simulation Analysis on Performance Comparison between R744 and R22 Solar Hybrid Heat Pump (R744와 R22를 적용한 태양열 하이브리드 열펌프의 성능 시뮬레이션 비교 분석)

  • Kang, Byun;Cho, Honghyun
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.2
    • /
    • pp.1-10
    • /
    • 2013
  • Simulation study of a solar hybrid heat pump using R744 and R22 for residential applications was carried out according to heat pump operating temperature, outdoor temperature and solar radiation. As a result, when the heat pump operating temperature increases from $40^{\circ}C$ to $48^{\circ}C$, the COP of a R744 and R22 heat pump system decrease from 2.15 to 1.7 and from 3.09 to 2.69, respectively. Besides, as the outdoor temperature rises from $3^{\circ}C$ to $11^{\circ}C$, the COP of R744 and R22 heat pump system increase from 1.73 to 2.12 and from 2.73 to 3.02. When the solar radiation increases from 10 to 20 $MJ/m^2$, the collector operating time and collector efficiency of R744 heat pump increase 10.3 times and 50.7%, respectively. The performance of R744 solar hybird heat pump is more sensitive to operation condition compared to that of R22. Besides, the solar heating system is more effective to the R744 heat pump system.

Anilinolysis of Diphenyl Thiophosphinic Chloride and Theoretical Studies on Various R1R2P(O or S)Cl

  • Dey, Nilay Kumar;Han, In-Suk;Lee, Hai-Whang
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.11
    • /
    • pp.2003-2008
    • /
    • 2007
  • The aminolysis of diphenyl thiophosphinic chloride (2) with substituted anilines in acetonitrile at 55.0 oC is investigated kinetically. Kinetic results yield large Hammett ρX (ρnuc = ?3.97) and Bronsted βX (βnuc = 1.40) values. A concerted mechanism involving a partial frontside nucleophilic attack through a hydrogen-bonded, four-center type transition state is proposed on the basis of the primary normal kinetic isotope effects (kH/kD = 1.0-1.1) with deuterated aniline (XC6H4ND2) nucleophiles. The natural bond order charges on P and the degrees of distortion of 42 compounds: chlorophosphates [(R1O)(R2O)P(=O)Cl], chlorothiophosphates [(R1O)(R2O)P(=S)Cl], phosphonochloridates [(R1O)R2P(=O)Cl], phosphonochlorothioates [(R1O)R2P(=S)Cl], chlorophosphinates [R1R2P(=O)Cl], and chlorothiophosphinates [R1R2P(=S)Cl] are calculated at the B3LYP/ 6-311+G(d,p) level in the gas phase.

Electromagetic Wave Absorbing Properties of $Ni_{0.5}-Zn_{0.4}-X_{0.1}{\cdot}Fe_2O_4$(X=Cu, Mg, Mn)-Rubber Composite ($Ni_{0.5}-Zn_{0.4}-X_{0.1}{\cdot}Fe_2O_4$(X=Cu, Mg, Mn)-Rubber Composite의 전파흡수특성에 관한 연구)

  • Im, Hui-Dae;Yun, Guk-Tae;Lee, Chan-Gyu
    • Korean Journal of Materials Research
    • /
    • v.9 no.12
    • /
    • pp.1234-1239
    • /
    • 1999
  • Electromagnetic wave asorbing properties of the $Ni_{0.5}-Zn_{0.4}-X_{0.1}{\cdot}Fe_2O_4$, where X was replaced by substitution elements Cu, Mg, Mn, have been studied. The structure, shape, size and magnetic properties of the $Ni_{0.5}-Zn_{0.4}-X_{0.1}{\cdot}Fe_2O_4$ were analyzed by XRD, SEM, VSM. The relative complex permittivity, permeability, and electromagnetic wave absorbing properties were measured by Network Analyzer. The structure, shape, size and magnetization value of the $Ni_{0.5}-Zn_{0.4}-X_{0.1}{\cdot}Fe_2O_4$ were found to be similar in spite of substitution elements. The coercive force and hysteresis-loss showed maximum value when Mg was substituted for X. The dielectric loss(${\varepsilon}_r"/{\varepsilon}_r'$) was found to be maximum value when Mn was substituted for X. Also the magnetic loss(${\mu}_r"/{\mu}_r'$} was found to be maximum with Cu substitution. The electromagnetica wave absorbing property of the $Ni_{0.5}-Zn_{0.4}-X_{0.1}{\cdot}Fe_2O_4$-Rubber composite with 4mm thickness was excellent as over - 40dB at 9GHz, and the $Ni_{0.5}-Zn_{0.4}-X_{0.1}{\cdot}Fe_2O_4$-Rubber composite with 8mm thickness was over-40dB at 2GHz. Those composites also showed superior microwave absorbing properties.

  • PDF

Contribution of Root Respiration to Soil Respiration for Quercus acutissima Forest (상수리나무림의 토양호흡에 대한 뿌리호흡의 기여)

  • Lee, Kyu-Jin;Won, Ho-Yeon;Mun, Hyeong-Tae
    • Korean Journal of Environment and Ecology
    • /
    • v.26 no.5
    • /
    • pp.780-786
    • /
    • 2012
  • A trenching method was used to determine the contribution of root respiration to soil respiration in Quercus acutissima forest in the vicinity of Gongju, Chungnam Province, Korea. $CO_2$ efflux in soil respiration plot($R_{control}$, $R_c$) and microblal respiration plot($R_{trenched}$, $R_t$) in Q. acutissima forest were measured from June 2011 to May 2012 by using IRGA soil respiration analyzer. Seasonal $CO_2$ efflux in $R_c$ and $R_t$ were higher in summer season than in winter season. In August, maximun $CO_2$ efflux in $R_c$ and $R_t$ was 1.345 and 0.897 g $CO_2\;m^{-2}\;hr^{-1}$, respectively. $CO_2$ efflux in $R_t$ was lower by 33.31% than that in $R_c$(P<0.05). In January, $CO_2$ efflux in $R_c$ and $R_t$ was 0.097 and 0.032g $CO_2\;m^{-2}\;hr^{-1}$, respectively. $CO_2$ efflux in $R_t$ was lower by 67.01% than that in $R_c$(P<0.01). The amount of annual $CO_2$ efflux from $R_c$ and $R_t$ was 4.320, 2.834kg $CO_2\;m^{-2}\;yr^{-1}$, respectively. There was a significant correlations between soil temperatures and soil respiration. Contribution of root respiration to total soil respiration in this Q. acutissima forest was 34.40%.

Effects of 60 Minutes Cardiopulmonary Resuscitation on Blood Lactic Acid Concentration, Heart Rate, and Rating of Perceived Exertion in Rescuers

  • Han, Seung-Eun;Ahn, Hee-Jeong;Shim, Gyu-Sik;Bang, Sung-Hwan;Song, Hyo-Suk
    • Journal of the Korea Society of Computer and Information
    • /
    • v.27 no.8
    • /
    • pp.195-202
    • /
    • 2022
  • In this study, when cardiopulmonary resuscitation continued for a long time, the rescuer's blood lactic acid concentration, heart rate, and rating of perceived exertion were measured to identify the change in the rescuer's fatigue. Data collection was conducted from July 5 to July 9, 2021, with a total of 24 students, 12 students department of special warfare medical non-commissioned officer, and 12 students department of emergency medical technology at D University, undergoing a two-person alternative chest compression resuscitation for 60 minutes. As a result of the study, the rescuer's blood lactic acid concentration, heart rate, rating of perceived exertion, and chest compression speed were significantly changed according to the duration of CPR (p<.001, p<.001, p<.001, p<.001). blood lactic acid concentrations at every measurement cycle (30 minutes, 40 minutes, 50 minutes, 60 minutes) showed a significant positive correlation with heart rate (r=.696, p<.001, r=.672, p<.001, r=.709, p<.001, r=.782, p<.001), there was also a significant positive correlation with the rating of perceived exertion (r=.476, p<).05, r=.426, p<.05, r=.470, p<.05, r=.470, p<.05). Therefore, monitoring the fatigue of rescuers using heart rate and rating of perceived exertion will be useful for maintaining high-quality chest compression in situations where cardiopulmonary resuscitation is required for a long time.

Foundation Color Image Analysis (파운데이션 색상 이미지 분석)

  • Hee-Kyung Lim
    • Journal of the Korean Applied Science and Technology
    • /
    • v.40 no.6
    • /
    • pp.1580-1588
    • /
    • 2023
  • The desire for clear and clean skin is universal among both men and women. Women, in particular, seek the help of foundation to achieve beautiful and transparent skin. The choice of foundation is not determined by the race of an individual; instead, it varies based on personal skin color and undertone. Therefore, there is a need to surpass the stereotype of using foundation colors based on racial discrimination. The purpose of this study is to randomly select cosmetics brands from Korea, China, Japan, the United States, France, and the United Kingdom, considering the impact of each photo, environment, and equipment. The objective is to understand the differences in skin tones in foundation advertisement model images on websites. Analyzing the RGB values of foundation colors for each brand revealed that in Korea, the colors were 8.75R, 1.25YR, 2.5YR, 3.75YR, 5YR, and 6.25YR. Chinese brands showed similar colors with 2.5YR, 3.75YR, 5YR, 6.25YR, and 10YR. Japanese brands displayed colors such as 7.5R, 8.75R, 10R, 5YR, 6.25YR, and 7.5YR. American brands presented colors like 6.25R, 8.75R, 10R, 2.5YR, 3.75YR, 5YR, 6.25YR, 7.5YR, and 10YR. French brands featured 10R, 1.25YR, 3.75YR, 5YR. Lastly, British brands displayed 2.5YR, 3.75YR, 7.5YR. As a follow-up study, in-depth research on the reshaping and color changes of foundation over time is recommended. It is hoped that this research will serve as fundamental data for makeup companies' marketing and contribute to the development of both domestic and international color cosmetics markets.

Effects of Curing Temperature on the Unconfined Compressive Strength of Lime Soil Mixtures (양생온도(養生溫度)가 석회혼합토(石灰混合土)의 압축강도(壓縮强度)에 미치는 영향(影響))

  • Kim, Jae Young;Kang, Yea Mook;Kim, Sung Wan
    • Korean Journal of Agricultural Science
    • /
    • v.2 no.2
    • /
    • pp.433-444
    • /
    • 1975
  • This study was conducted to investigate the strength of lime soil mixtures for varied' curing temperatures(20, 30, 40, 50, $60^{\circ}C$) and lime content (3, 6, 9, 12%) in four lime-stabilized soils(KY : Sand, MH : Sand, SS: Sandy loam. JJ : Loam). The experimental results obtained from unconfined compressive strength tests are as follows; 1. The optimum moisture content increased and maximum dry density decreased with the increase of the lime content. 2. The lime content for the maximum strength of SS and JJ soils showed at the 9 percent lime content, but KY and MH soils didn't show the tendency of increase and decrease by the lime content and curing period. The rate of decrease of the soaked unconfined compressive strength showed the lower value in accordance with lime content. 3. According to increase in curing temperatures in curing temperatures at 30, 40, 50, $60^{\circ}C$, the unconfined compressive strength of lime soil mixtures increased, the rate of increase initially increased at a rapid rate, and showed that around 120 hours were sufficient curing time to complete hardening. 4. The average maximum temperature of Korea being around $30^{\circ}C$ from July to August, thus these months are ideal construction periods to increase the strehgth of lime soil mixtures. 5. Accelerated curing times equivalent to 28-day normal curing decreased in accordance with the increase of curing temperature, and showed shorter in lime soil mixtures than soil cement. 6. Accelerated curing times versus normal curing times are formed as a linear, its slope decreased in accordance with the increase of curing temperature, it may be expressed as follows: (1). $30^{\circ}C$ : t=2.63d-1.4(r=0.99) (2). $40^{\circ}C$ : t= 1.76d-0.8(r=0.97) (3). $50^{\circ}C$ : t=1.35d-3.2(r=0.94) (4). $60^{\circ}C$ : t=0.49d+1.8(r=0.91) in which t ; Accelerated curing time d ; Normal curing time.

  • PDF

A Study on Service R&D Budgeting and Investment Strategy (서비스 R&D 예산편성 및 투자전략 연구)

  • Kim, Hyunsoo
    • Journal of Information Technology Services
    • /
    • v.12 no.2
    • /
    • pp.373-386
    • /
    • 2013
  • The purpose of this research is to develop a model for efficient service R&D investment in government budgeting process. It is necessary to develop an efficient and effective investment model to improve competitiveness of the service industry and national economy. Various existing types of service R&D classification have been reviewed. And object-oriented service R&D request classification types have been derived. A tentative model for evaluating service R&D requests have been developed through extensive discussions on effective methodologies. The model has been refined and revised by four service budgeting experts. The revised and refined checklists and guidelines have been used for 40 real service R&D requests evaluations. As a result, a full model for service R&D evaluation and budgeting has been proved to be useful. Also, a need for more efficient and concise evaluation model has been raised through this evaluation process. A brief model with only 10 checklists has been developed and its usefulness has been proven by pilot test with 10 real service R&D requests. The results of this study can be used for evaluation of service R&D proposals and effective budgeting of R&D requests for improving global competitiveness. Further research is needed for refining the developed evaluation models.

A Comparison of Imported Medical Compression Stockings by Manufacturing Country (수입 의료용 압박스타킹의 제조국가별 비교)

  • Do, Wol-Hee;Kim, Nam-Soon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.36 no.3
    • /
    • pp.335-345
    • /
    • 2012
  • This study provides product survey data for the development of medical compression stockings. An investigation analyzed imported medical compression stockings of 40 brands from 6 countries sold in the Korean market, such as Jobst$^{(R)}$, Therafirm$^{(R)}$, Rxtar$^{(R)}$, Varicoin$^{(R)}$, and Sheer&Soft (USA), Sigvaris Venosan$^{(R)}$ 4000 (Switzerland), Best$^{(R)}$ and Segreta$^{(R)}$ (Italy), Venex$^{(R)}$, Star cotton, Doktus$^{(R)}$, Maxis$^{(R)}$, Maxis$^{(R)}$ Cotton, Lastofa$^{(R)}$, and Memory Aloe Vera (Germany), and Gunze (Japan), Venos and Yolanda (Taiwan). The main fibers of compression stockings were nylon and spandex; in addition, the fiber content was different by country and brand. The number of compression classes of imported products was USA (5), Italy (5), Germany (4), Switzerland (3), Japan (3), and Taiwan (3). For basic body measurements, USA and Swiss brands used ankle circumference, calf circumference, thigh circumference, calf length, and thigh length. Italian brands used height and weight, and Japanese brands used height and hip circumference. German brands used subdivided circumferences such as ankle circumference, calf circumference, knee circumference, middle thigh circumference, and thigh circumference.