• Title/Summary/Keyword: R40

Search Result 5,787, Processing Time 0.032 seconds

The effect of the revolution and forwarding speed of the rotary blade on the tilling power requirement (로우터리 경운(耕耘)날의 회전속도(回轉速度) 및 작업속도(作業速度)가 경운소요동력(耕耘所要動力)에 미치는 영향(影響))

  • Kwon, Soon Goo;Kim, Soung Rai
    • Korean Journal of Agricultural Science
    • /
    • v.11 no.1
    • /
    • pp.160-175
    • /
    • 1984
  • This study was carried out to analyze the effects of the revolution and forwarding speed of the rotary blade and the edge curves which were $30^{\circ}$ and $40^{\circ}$, on the power requirement of rotary tillage. In this study, the revolutions of the rotary blade considered were 204, 243, 285, 360 rpm, and the forwarding speeds of the rotary system considered were 29.40cm/sec, 46.93em/sec. The power requirements of rotary blade were measured by a dynamic strain gage systems at the soil bin which was filled with artificial soil. The results of the study were summarized as follows: 1. The response surface analysis showed that the revolution and forwarding speed of the rotary shaft had an interacting influence on the torque requirement of the rotary blade. The mathematical model developed by the above was repersented as follow. $$T=a_0+a_1V+a_2R +a_3VR+a_4VR^2$$ where, $a_0=constant$ $a_1,\;a_2,\;a_3,\;a_4=coefficients$ V=forwarding speed of the rotary system. (em/sec) R=revolution of the rotary shaft. (rpm) T=tilling torque requirement. (kg-m) 2. When the maximum tilling torque requirement was analyzed, ${\partial}T/{\partial}R$ was decreased with the increasing revolution of rotary shaft, while ${\partial}T/{\partial}V$ was increased, which was minimum at 200~220 rpm. When the forwarding speeds were increased, ${\partial}T/{\partial}R$ was decreased with increasing rate. 3. When the mean tilling torque requirement was analyzed, ${\partial}T/{\partial}V$ was constant at 320~360 rpm and ${\partial}T/{\partial}R$ was decreased with increasing rate along with the increasing revolution of rotary shaft. 4. When the mean tilling torgue requirement per unit volume of soil was analyzed, ${\partial}T/{\partial}V$ was minimum at 270~300 rpm. ${\partial}T/{\partial}R$ for the forwarding speeds of 29.40cm/sec and 46.93cm/sec was same as that for 280~290 rpm. 5. Increasing the edge curves of the rotary blades, the tilling torque requirement was increased. But other studies showed that the smaller the edge curve, the more straw could be wrapped on blades which resulted in increasing torque requirements. Therefore, the edge curve of rotary blade should be considered for the future study.

  • PDF

Comparative Evaluation of Erythrocyte Sedimentation Rate by the Test 1 Analyzer and Westergren method in Patients with Anemia (빈혈환자에서 자동 ESR 기기인 Test 1과 Westergren법의 비교)

  • Kim, Il Taek;Kim, Jong Seok;Park, Yeon Bo;Lim, Jae Sil
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.36 no.2
    • /
    • pp.137-143
    • /
    • 2004
  • Erythrocyte sedimentation rate(ESR) measurements were performed in a total of 191 blood samples from patients below a hematocrit of 35% by both the Test-1(SIRE Analytical Systems, Udine, Italy) and the Westergren method, endorsed as the reference method for ESR by the International Council for Standardization in Hematology(ICSH). The corrected Westergren ESR values were also obtained applying the formula of Fabry (corrected ESR = ESR measured x 15/55-Hct). Linear regression analysis showed a close correlation (r=0.85) between the two methods both before and after ESR correction in total samples. There was no significant correlation difference between two methods in both two groups with hemoglobin $${\geq_-}9g/dl$$ and <9g/dl before and after ESR correction (r=0.873, r=0.827 respectively before correction and r=0.867, r=0.830 respectively after correction). Also, for two groups with hematocrit $${\geq_-}24%$$ and <24%, no significant difference was observed (r=0.859, r=0.792 respectively before correction and r=0.782, r=0.842 respectively after correction). However, for samples with <60mm of Westergren ESR before correction, a better correlation coefficient was obtained than samples with $${\geq_-}60mm$$(r=0.701, r=0.541 respectively). In corrected Westergren ESR, also samples that were obtained with <40mm showed better correlation than samples with $${\geq_-}40mm$$ (r=0.690, r=0.347 respectively). In conclusion, we found a good correlation between Test-1 and Westergren measurements in patients with anemia but an expert group discussion is required to solve discrepancy between two methods in blood samples with very high ESR.

  • PDF

Study on the Ideal Adapted Body Weight of Korean Adults Men with reference to 30-39, 40-49 and 50-59 Age-group (한국성인남자(韓國成人男子)의 정상적응체중치(正常適應體重値)에 관(關)한 연구(硏究) -30대(代), 40대(代), 50대군(代群)을 중심(中心)으로-)

  • Park, Soon-Young
    • Journal of Preventive Medicine and Public Health
    • /
    • v.10 no.1
    • /
    • pp.44-51
    • /
    • 1977
  • In order to determine values for the body weight by height groups for Korean adults men who are fully grown up 4,028 (30-39 age-group ; 2,318, 40-49 age-group 1,340, and 50-59 age group : 370) apparently healthy males subjects were randomly selected for the measurement of body weight by height groups. 1) The avergae body height and weight of Korean adult men were $168.3{\pm}4.6cm$ and $63.4{\pm}7.1kg$ in 30-39 age group, $167.7{\pm}4.7cm$ and $63.4{\pm}7.4kg$ in 40-49 age group, and $167.3{\pm}5.2cm$ and $63.3{\pm}8.0kg$ in 50-59 age group. 2) A correlation coefficient of r=+0.52(P<0.001) between body height and weight was found in 30-39 age group of 2,318 subject, r=+0.48(P<0.001) in 40-49 of 1,340 and r=+0.53(P<0.001) in 50-59 of 370 with the aid of there coefficients of linear regression equation body weight and height were established for male as follow; for 30-39 age group, Y(weight in kg)=0.81X(height in cm)-73.02, 40-49 age group, Y(weight in kg)=0.74X(height in cm)-61.82, 50-59g age-group, Y(weight in kg)=0.82X(height in cm)-73.83. 3) With the aid of above listed various equation standard values for body weight by height group, with over weighing and under weighing values were established. 4) Standard bodyweight of Korean was lower than those of American, Japanese and several other formulas for ideal body weight.

  • PDF

IZO/Ag/IZO Multilayers Prepared by Magnetron Sputtering for Flexible Transparent Film Heaters (마그네트론 스퍼터링 법을 이용한 IZO/Ag/IZO 다층 박막 투명 면상 발열체)

  • Park, So-Won;Gang, Dong-Ryeong;Kim, Na-Yeong;Hwang, Seong-Hun;Jeon, Seung-Hun;ZhaoPin, ZhaoPin;Kim, Tae-Hun;Kim, Seo-Han;Park, Cheol-U;Song, Pung-Geun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2017.05a
    • /
    • pp.114.2-114.2
    • /
    • 2017
  • Transparent film heaters (TFHs) based on Joule heating are currently an active research area. However, TFHs based on an indium tin oxide (ITO) monolayer have a number of problems. For example, heating is concentrated in part of the device. Also, heating efficiency is low because it has high sheet resistance ($R_S$). Resistance of indium zinc oxide (IZO) is similar to ITO and it can be used to flexible applications due to its amorphous structure. To solve these problems, our study introduced hybrid layers of IZO/Ag/IZO deposited by magnetron sputtering, and the electrical, optical, and thermal properties were estimated for various thickness of the metal interlayer. It was found that the sheet resistance of the multilayer was mainly dependent on the thickness of the Ag layers. The $R_S$ of IZO(40)/Ag/IZO(40nm) multilayer was 5.33, 3.29, $2.15{\Omega}/{\Box}$ for Ag thickness of 10, 15, and 20nm, respectively, while the $R_S$ of an IZO monolayer(95nm) was $59.58{\Omega}/{\Box}$. The optical transmittance at 550nm for the IZO(95nm) monolayer is 81.6%, and for the IZO(40)/Ag/IZO(40nm) multilayers with Ag thickness 10, 15 and 20nm, is for 72.8, 78.6, and 63.9%, respectively. The defrost test showed that the film with the lowest RS had the highest heat generation rate (HGR) for the same applied voltage. The results indicated that IZO(40)/Ag(15)/IZO(40nm) multilayer has the best suitable property, which is a promising thin film heater for the application in vehicle windshield.

  • PDF

Formulation of Multivitamin Solutions for Infants (유아용 종합비타민 액제의 제제 설계)

  • Hong, Ji-Woong;Park, Eun-Seok;Chi, Sang-Cheol
    • YAKHAK HOEJI
    • /
    • v.40 no.3
    • /
    • pp.243-250
    • /
    • 1996
  • In order to formulate aqueous multivitamin solutions containing both oil-soluble (A, D, E) and water-soluble vitmains ($B_1,\;B_2,\;B_6,\;B_{12}$, C and niacinamide) in 1ml-dose, the effects of various additives such as cosolvents (propylene glycol, polyethylene glycol, glycerin), a sweetener (sorbitol) and a surfactant (Cremophor$^{\circledR}$ RH40) on the solubility of oil-soluble vitamins in water were evaluated. Cremophor$^{\circledR}$ RH40 showed the excellent capacity on the solubilization of oil-soluble vitamins, and the simultaneous addition of cosolvents and surfactant resulted in synergetic effects on the solubilization of oil-soluble vitamins. The effects of the combination of the cosolvents and sweetener on the stability of multivitamin solutions were also evaluated by determining the amount of vitmain A and $B_1$ remained in the solutions after storing at $40^{\circ}C$ for 9 weeks. The formulation consisting of Cremophor$^{\circledR}$ RH40 15%, PG 20%, and sorbitol 20% resulted in the best stability of vitamin A and $B_1$. The stability of vitamin A and $B_1$ in this formulation was evaluated at 50, 60, and $70^{\circ}C$ up to 40 days. The shelf-lives of vitamin A and $B_1$ in the formulation, calculated using the Arrhenius equation, were 1,521 days and 475 days at $20^{\circ}C$, respectively.

  • PDF

Histochemical study on the endochondral ossification of the native Korean cattle femur (한우 대퇴골의 연골내골화에 관한 조직화학적 연구)

  • Kim, Soo-myung;Yang, Hong-hyun;Paik, Young-ki
    • Korean Journal of Veterinary Research
    • /
    • v.31 no.2
    • /
    • pp.143-154
    • /
    • 1991
  • The present study was undertaken to provide basic data on fetal endochondral ossification for the native Korean cattle femur. This study was determined to the both earliest stages of chondrification and ossification by histochemical methods. The forty-five pairs of femur, from a series of embryos and fetuses ranging from 11 to 100mm in crown-rump(C-R) length, were used. These samples were divided into 9 groups. The groupings were based on C-R length, as the first grouping being 11~20mm, the second grouping being 21~30mm and so on. The results were as follows: 1. Alcianophility and PAS reaction were markedly increased in the perichondrium and interterritorial matrix in the 3rd group(C-R length 31~40mm). These reactions were decreased in the territorial matrix and in the adjacent area to the cartilage canal in the 5th group(C-R length 51~60mm). 2. Calcium deposits and collagen substances were observed initially in the 3rd group(C-R length 31~40mm). The calcium deposits and calcified cores were observed in the trabeculae of the proximal epiphyseal plate of the femur in the 8th group(C-R length 81~90mm).

  • PDF

The Empirical Study on Relation between R&D Innovation Capability and Performance in Knowledge-Based Service Firms (R&D 혁신역량과 기업성과 간의 관계 연구)

  • Kim, Moon Sun;Kim, Soo Jung;Nam, Kyung H.
    • Journal of Korean Society for Quality Management
    • /
    • v.40 no.4
    • /
    • pp.631-640
    • /
    • 2012
  • Purpose: This empirical study is focused on the relationship between innovation capability (R&D and Human Resource innovation) and performance in knowledge-based service firms. Methods: We build research model to test how each of innovation capability on technology and human resource is influenced on their financial and non-financial performance in the knowledge-based service industries. Based on the previous research, we hypothesized the factors are regarded innovation capabilities of the firms as the scale of R&D and human resources. Because this study is especially targeted to the performance of knowledge-based service firms. With the survey on 424 main knowledge-based service firms, the multi-regression analysis was performed. Results: The result showed that the scale of R&D and human resources capabilities are main factors for knowledge-based service firms' performance, which reflects the current industrial structure. Conclusion: This study empirically demonstrated that human resources are most important to the growth of knowledge-based service firms.

Rain Attenuation Analysis for Designing UAV Data Link on Ku-Band (Ku대역 무인항공기 데이터 링크 설계를 위한 강우감쇠 분석)

  • Lee, Jaeyoon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.7
    • /
    • pp.1248-1256
    • /
    • 2015
  • It is necessary to apply an exact data and a precise prediction model for a rain attenuation to design the link margin for a data link using Ku-band with the serious effect by rain. In this paper, we investigate the regional rainfall-rate distribution of Korea proposed in TTAK.KO-06.0122/R1 and compare it with the distribution provided by Rec. ITU-R PN.837-1 and Crane. And, the rain rate climate regions similar with the rainfall-rate distribution of Korea in Rec. ITU-R PN.837-1 and Crane model are selected. Finally, using Rec. ITU-R P.618-8 and Crane rain attenuation prediction model, we derive and analyze the rain attenuation for Ku-band frequency according to the time percentage of an average year and the distance of wireless communication link between unmanned aerial vehicle (UAV) and ground data terminal (GDT).