• Title/Summary/Keyword: R22와 R134a

Search Result 14, Processing Time 0.021 seconds

Comparison of Condenser Characteristics using R134a and R22 under the Same Inlet Temperature Condition (동일한 유입온도조건에서 R134a와 R22 적용 응축기의 특성비교)

  • Kang, Shin-Hyung;Byun, Ju-Suk;Kim, Chang-Duk
    • Journal of Energy Engineering
    • /
    • v.15 no.3 s.47
    • /
    • pp.166-173
    • /
    • 2006
  • R134a is considered as an alternative refrigerant to R22 for air conditioners. An experimental investigation was made to study the characteristics of the heat transfer and pressure drop for R134a flowing in a fin-and-tube heat exchanger used for commercial air-conditioning units. Experiments were carried out under the conditions of inlet refrigerant temperature of $60^{\circ}C$ and refrigerant mass fluxes of $150,\;200,\;and\;250\;kg/m^{2}s$. The inlet air has dry bulb temperature or $35^{\circ}C$, relative humidity of 40% and air velocity varying from 0.68 to 1.6 m/s. Experiments show that air velocity decreased by 5.9% is needed for R134a than that of R22 while pressure drop for R134a was $18.1{\sim}20.4%$ higher than that of R22 for the degree of subcooling $5^{\circ}C$. The results are useful in designing more compact and effective condensers for various refrigeration and air conditioning systems using refrigerant R134a.

The Evaporation Flow Patterns and Heat Transfers of R-22 and R-134a in Small Diameter Tubes (세관내 R-22 and R-134a의 증발 유동양식과 열전달)

  • Son, Chang-Hyo
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.18 no.3
    • /
    • pp.275-283
    • /
    • 2007
  • 본 논문은 세관(ID<7 mm) 내 R-22와 R-134a의 증발 열전달과 유동양식에 대한 실험적 연구이다. R-22와 R-134a의 유동양식을 관찰하기 위해 내경 2와 8 mm의 파이렉스 튜브를 사용하였고, 열전달 계수는 내경 1.77, 3.35, 5.35 mm의 수평 평활동관에 대해서 측정하였다. 증발 유동양식에서 내경 2 mm의 환상류 영역이 내경 8 mm에 비해 저건도 영역에서 발생하는 것을 확인할 수 있었고, 내경 2 mm의 유동양식은 Mandhane의 선도와 많은 오차를 보였다. 세관(ID<7 mm) 내 증발 열전달 계수는 종래의 대구경관(ID>7 mm)에 비해 관직경에 대한 영향이 많이 나타나는 것을 알 수 있었다. 내경 1.77 mm의 열전달 계수는 내경 3.36 mm와 5.35 mm에 비해서 20내지 30% 정도 높은 것을 나타났다. 또한 종래의 열전달 상관식(Shah's, Jung's, Kandlikar's and Oh-Katsuda's correlation)과 비교한 결과, 실험 데이터는 상관식과 많은 이탈 정도를 보였다. 따라서 실험데이타를 기초로 세관내 R-22와 R-134a에 적용할 수 있는 증발 열전달 상관식을 새로이 제안하였다.

Prediction and Experiment of Pressure Drop of R22 and R134a on Design Conditions of Condenser (응축기의 설계조건에서 R22와 R134a의 압력강하 예측 및 실험)

  • Kang, Shin-Hyung;Byun, Ju-Suk;Kim, Chang-Duk
    • Journal of Energy Engineering
    • /
    • v.15 no.4 s.48
    • /
    • pp.243-249
    • /
    • 2006
  • An experimental study on the refrigerant-side pressure drop of slit fin an tube heat exchanger has been carried out. A comparison was made between the predictions of previously proposed empirical correlations and experimental data for the pressure drop on design conditions of condenser in micro-fin tube for R22 and Rl34a. Experiments were carried out under the conditions of inlet refrigerant temperature of $60^{\circ}C$ and mass fluxes varying from $150\;to\;250\;kg/m^{2}s$ for R22 and Rl34a. The inlet air conditions are dry bulb temperature of $35^{\circ}C$, relative humidity of 40% and air velocity varying from 0.68 to 1.43 m/s. Experiments show that pressure drop for R134a was $22{\sim}22.6%$ higher than R22 for the degree of subcooling $5^{\circ}C$ For the mass fluxes of $200{\sim}250\;kg/m^{2}s$, the deviation between the experimental and predicted values for the pressure drop was less than ${\pm}20%$ for R22 and Rl34a.

A Comparison of Flow Condensation HTCs of R22 Alternatives in the Multi-Channel Tube (다채널 알루미늄 평판관내 R22와 R134a의 흐름 응축 열전달 성능 비교)

  • 서영호;박기정;정동수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.6
    • /
    • pp.589-598
    • /
    • 2004
  • Flow condensation heat transfer coefficients (HTCs) of R22 and R134a were measured on a horizontal 9 hole aluminum multi-channel tube. The main test section in the refrigerant loop was made of a flat multi-channel aluminum tube of 1.4 mm hydraulic diameter and 0.53 m length. Refrigerant was cooled by passing cold water through an annulus surrounding the test section. Data were obtained in the vapor qualities of 0.1∼0.9 at mass flux of 200∼400 kg/$m^2$s and heat flux of 7.3∼7.7 ㎾/$m^2$ at the saturation temperature of 4$0^{\circ}C$. All popular correlations in single-phase subcooled liquid and flow condensation originally developed for large single tubes predicted the present data of the flat tube within 20% deviation when effective heat transfer area is used in determining experimental data. This suggests that there is little change in flow characteristics and patterns when the tube diameter is reduced down to 1.4 mm diameter range. Thermal insulation for the outer tube section surrounding the test tube for the transport of heat transfer fluid is very important in fluid heat-ing or cooling type heat transfer experimental apparatus.

Condensing Heat Transfer Characteristics of R-22 and R-134a in Small Diameter Tubes (세관내 R-22와 R-134a의 응축 전열 특성에 관한 연구)

  • Hong, Jin-U;No, Geon-Sang;Jeong, Jae-Cheon;O, Hu-Gyu
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.1
    • /
    • pp.54-61
    • /
    • 2001
  • Condensing heat transfer coefficients of R-22 and R-134a were measured in smooth, horizontal copper tubes with inner diameters of 1.77mm, 3.36mm, and 5.35mm, respectively. The experiments were conducted in the closed loop, which was driven by a magnetic gear pump. Data are presented for the following range of variables : mass velocity from 200 to 500kg/$m^2$.s and quality from 0 to 1.0. The heat transfer coefficients in the small diameter tubes (ID < 7mm) were observed to be strongly affected by various diameters and the heat transfer characteristics in the small diameter tubes differed from those in the large diameter tubes. Heat transfer coefficients in the small diameter tubes are higher than those in the large diameter tubes at the same experimental condition. It was found that some well-known previous correlations(Shahs correlation and Cavallini-Zecchins correlation) were not suitable for small diameter tubes.

Experimental study for the pressure drop of R-22 and R-4O7C during the condensation in the micro-fin tubes (마이크로핀관내에서 R-22와 R-4O7C의 응축압력강하 특성에 관한 실험적 연구)

  • Roh, Geon-Sang
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.6
    • /
    • pp.715-722
    • /
    • 2007
  • Experiments were conducted for the investigation of pressure drop inside horizontal micro-fin tubes during the condensation of R-22 and ternary refrigerant. R-407C(HFC-32/125/134a 23/25/62 wt%) as a substitute of R-22. The condenser is a double-tube and counterflow type heat exchanger which is consisted with micro-fin tubes having 60 fins with a length of 4000mm, outer diameter of 9.53mm and fin height of 0.2mm. The mass velocity varied from 102.1 to $301.0kg/(m^2{\cdot}s)$ and inlet quality was fixed as 1.0. From the experimental results. the pressure drop for R-407C was considerably higher than that for R-22. The value of PF(penalty factor) for both of refrigerants was not bigger than the ratio of micro-fin tube area to smooth tube area. Based on the experimental data. correlation was Proposed for the prediction of frictional pressure drop during the condensation of R-22 and R-407C inside horizontal micro-fin tubes.

A Study of Closed OTEC Power Plants (폐쇄형 해양온도차발전 사이클에 관한 연구)

  • Shin, Sang-Ho;Jung, Dong-Soo;Kim, Chong-Bo;Seo, Tae-Beom;Chun, Won-Gee;Auh, P. Chung-Moo
    • Solar Energy
    • /
    • v.17 no.4
    • /
    • pp.23-33
    • /
    • 1997
  • In this paper, performance of various working fluids is evaluated for the closed Ocean Thermal Energy Conversion(OTEC) power plant operating on Rankine cycle. The evaporator and condenser are modeled via UA and LMTD method while turbine and pump are modeled by specifying isentropic efficiencies. R22, Propane, Propylene, R134a, R125, R143a, R32, R410A and Ammonia are used as working fluids. Results show that newly developed fluids such as R410A and R32 that do not cause stratospheric ozone layer depletion perform as well as R22 and ammonia. The superheat at the evaporator exit and subcooling at the condenser exit do not affect the performance of the simple OTEC power cycle. Turbine efficiency and heat exchanger size influence greatly the performance of the Rankine cycle. Finally, it was shown that closed OTEC power plants can practically generate electricity when the difference in warm and cold sea water inlet temperatures is greater than $20^{\circ}C$.

  • PDF

An Experimental Study on Flow Characteristics of R134a in a Small Diameter Tube (세관내 R-134a의 유동특성에 관한 실험적 연구)

  • Son, Chang-Hyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.6
    • /
    • pp.1307-1312
    • /
    • 2007
  • The flow characteristics of R-134a in a small diameter tube was investigated experimentally. An experimental apparatus was consisted of a magnetic gear pump, an evaporator, a sight-glass, a condenser and a measurement instruments. The sight-glass for flow pattern observations was located at the inlet and outlet of the evaporator. The experiment was carried out to show the flow characteristics of R-134a in a small diameter tube. Mass flux of refrigerants was ranged from 100 to 1000 $kg/m^2s$, the saturation temperature was $30^{\circ}C$. In the flow patterns during evaporation, the annular flow in a 2 mm inner diameter tube occurred at a relatively lower quality and mass velocity, compared to that in a 8 mm inner diameter tube. The evaporation flow pattern in a small diameter tube has been shown major deviations with the Baker, Mandhane and Taitel-Dutler's flow pattern maps but it was similar to the Dobson's flow pattern map.

  • PDF

Ice Formation on the Outer Surface of a Vertical Tube with Inside Refrigerant Boiling (관 내부 냉매비등이 있는 수직관 외부 얼음 형성 연구)

  • Nguyen, Minh Phu;Lee, Geun-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.2
    • /
    • pp.129-135
    • /
    • 2011
  • An ice-making model has been developed and analyzed in this study. The effects of the following on the ice formation on the outer surface of a tube in which a refrigerant flows and boils are numerically investigated: thermal resistance of the refrigerant and thermal resistance of the ice formed on the outer surface of the tube. The ice thickness and related variables are analyzed in the case of the refrigerants R22 and R134a by using the expressions for phase-change heat transfer and boiling heat transfer coefficient. Vapor qualities of the refrigerants range from 0 to 0.8. As a result, up to the first 30 min, the internal convection resistance is higher than the thermal resistance of the ice on the external surface of the tube. However, after about 30 min, the thermal resistance of the ice increases remarkably due to the increase in the ice thickness. Thus, the heat flux to the refrigerant decreases, and further, the refrigerant quality and the boiling heat transfer coefficient also decrease. As the heat transfer coefficient of R22 is higher than that of R134a, the mass of the ice formed when R22 is used is higher than that formed when R134a is used.