• Title/Summary/Keyword: R.M.R

Search Result 16,600, Processing Time 0.043 seconds

EVERY DEFINABLE Cr MANIFOLD IS AFFINE

  • KAWAKAMI, TOMOHIRO
    • Bulletin of the Korean Mathematical Society
    • /
    • v.42 no.1
    • /
    • pp.165-167
    • /
    • 2005
  • Let M = (R, +, $\cdot$, <, ... ) be an o-minimal expansion of the standard structure R = (R, +, $\cdot$, >) of the field of real numbers. We prove that if 2 $\le$ r < $\infty$, then every n-dimensional definable $C^r$ manifold is definably $C^r$ imbeddable into $R^{2n+l}$. Moreover we prove that if 1 < s < r < $\infty$, then every definable $C^s$ manifold admits a unique definable $C^r$ manifold structure up to definable $C^r$ diffeomorphism.

Drop-In Evaluation of Thermodynamic Performance of R-22 Alternative Refrigerant Mixtures (R-22 대체용 혼합냉매의 Drop-In 열역학적 성능 계산)

  • Ju, J.M.;Kim, C.N.;Park, Y.M.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.3
    • /
    • pp.423-436
    • /
    • 1996
  • Thermodynamic performance of eight zeotropic R-22 alternative refrigerant mixtures selected by AREP(R-22 Alternative Refrigerants Evaluation Program) and R-32/R-125/R-134a(23%/25%/52%), namely R-407C were evaluated by the "drop-in" simulation method. An existing air conditioner was selected and its design data were used for the simulation. "ARI Test A" air conditions were applied. The degree of vapor superheat at the compressor inlet fixed at $5^{\circ}C$ for all the mixtures. The results of the simulation were compared with those of R-22. COPs of all mixtures except for R-32/R-227ea(35%/65%) and R-32/R-125/R-134a(10%/70%/20%), were higher than that of R-22 by 2%~8%, while the capacities were all lower than that of R-22 by 13%~27%. COP of R-32/R-134a(40%/60%) was 2.4% higher but the capacity was 15% lower than those of R-22. In the case of R-32/R-134a(30%/70%), COP and capacity were 5.5% higher and 15% lower than those of R-22, respectively. Among the ternary mixtures, R-407C and R-32/R-125/R-134a(30%/10%/60%) showed the best performance. COP of R-407C was 2.4% higher than those of R-22 but the capacity was 15% lower.

  • PDF

Two More Radicals for Right Near-Rings: The Right Jacobson Radicals of Type-1 and 2

  • Rao, Ravi Srinivasa;Prasad, K. Siva
    • Kyungpook Mathematical Journal
    • /
    • v.46 no.4
    • /
    • pp.603-613
    • /
    • 2006
  • Near-rings considered are right near-rings and R is a near-ring. $J_0^r(R)$, the right Jacobson radical of R of type-0, was introduced and studied by the present authors. In this paper $J_1^r(R)$ and $J_2^r(R)$, the right Jacobson radicals of R of type-1 and type-2 are introduced. It is proved that both $J_1^r$ and $J_2^r$ are radicals for near-rings and $J_0^r(R){\subseteq}J_1^r(R){\subseteq}J_2^r(R)$. Unlike the left Jacobson radical classes, the right Jacobson radical class of type-2 contains $M_0(G)$ for many of the finite groups G. Depending on the structure of G, $M_0(G)$ belongs to different right Jacobson radical classes of near-rings. Also unlike left Jacobson-type radicals, the constant part of R is contained in every right 1-modular (2-modular) right ideal of R. For any family of near-rings $R_i$, $i{\in}I$, $J_{\nu}^r({\oplus}_{i{\in}I}R_i)={\oplus}_{i{\in}I}J_{\nu}^r(R_i)$, ${\nu}{\in}\{1,2\}$. Moreover, under certain conditions, for an invariant subnear-ring S of a d.g. near-ring R it is shown that $J_2^r(S)=S{\cap}J_2^r(R)$.

  • PDF

Contribution of Root Respiration to Soil Respiration for Quercus acutissima Forest (상수리나무림의 토양호흡에 대한 뿌리호흡의 기여)

  • Lee, Kyu-Jin;Won, Ho-Yeon;Mun, Hyeong-Tae
    • Korean Journal of Environment and Ecology
    • /
    • v.26 no.5
    • /
    • pp.780-786
    • /
    • 2012
  • A trenching method was used to determine the contribution of root respiration to soil respiration in Quercus acutissima forest in the vicinity of Gongju, Chungnam Province, Korea. $CO_2$ efflux in soil respiration plot($R_{control}$, $R_c$) and microblal respiration plot($R_{trenched}$, $R_t$) in Q. acutissima forest were measured from June 2011 to May 2012 by using IRGA soil respiration analyzer. Seasonal $CO_2$ efflux in $R_c$ and $R_t$ were higher in summer season than in winter season. In August, maximun $CO_2$ efflux in $R_c$ and $R_t$ was 1.345 and 0.897 g $CO_2\;m^{-2}\;hr^{-1}$, respectively. $CO_2$ efflux in $R_t$ was lower by 33.31% than that in $R_c$(P<0.05). In January, $CO_2$ efflux in $R_c$ and $R_t$ was 0.097 and 0.032g $CO_2\;m^{-2}\;hr^{-1}$, respectively. $CO_2$ efflux in $R_t$ was lower by 67.01% than that in $R_c$(P<0.01). The amount of annual $CO_2$ efflux from $R_c$ and $R_t$ was 4.320, 2.834kg $CO_2\;m^{-2}\;yr^{-1}$, respectively. There was a significant correlations between soil temperatures and soil respiration. Contribution of root respiration to total soil respiration in this Q. acutissima forest was 34.40%.

Differences of Rare Earth Element Concentrations of Plants in Top Soils of Gapyeong Serpentine Area: Based on the M. sinensis, A. vulgaris and R. crataegitolius (가평 사문암 지역의 토양 별 식물체내 희토류 원소 함량 차이: 억세, 쑥, 산딸기를 근거로)

  • Song, Suck-Hwan;Shin, Byung-Cheol
    • Journal of Environmental Science International
    • /
    • v.18 no.6
    • /
    • pp.621-632
    • /
    • 2009
  • Rare earth contents(REE) were analysed for the plants, M. sinensis. A. vulgaris and R. crataegitolius, from two different soils serpentine area consisting of serpentinite(SP) and non-serpentine area, containing amphibole schist(AS) of Gapyeong area, and were compared with soils and host rocks. The AS were high with the differences of several times in the top soils, and with the differences of several to ten times in the host rocks relative to the SP. In the same area, the SP were high in the soil, but the rocks for the AS. In the plants, the A. vulgaris were high, but low in the R. crataegitolius. Root parts were higher than the upper parts. Differences between the upper and root parts were big in the SP rather than the AS, and were big in the R. crataegitolius, but small in the M. sinensis. Among the parts of the plants, high elements were shown in the R. crataegitolius of the SP, and the A. vulgaris and M. sinensis of the AS. In the correlation coefficients, most of the REE showed positive relationships among the element pairs, especially high positive correlation coefficients in the upper parts of the SP.Differences of the soils and plants(average) were smalle in the M. sinensis and big in the R. crataegitolius. In the upper parts. contents of the A. vulgaris were close to the soils while the R. crataegitolius showed large discrepancies with the soils. In the root parts, contents of the A. vulgaris showed discrepancies with the soils regardless of soil types, but close in the R. crataegitolius of the SP and M. sinensis of the AS.

ON THE MATCHING NUMBER AND THE INDEPENDENCE NUMBER OF A RANDOM INDUCED SUBHYPERGRAPH OF A HYPERGRAPH

  • Lee, Sang June
    • Bulletin of the Korean Mathematical Society
    • /
    • v.55 no.5
    • /
    • pp.1523-1528
    • /
    • 2018
  • For $r{\geq}2$, let ${\mathcal{H}}$ be an r-uniform hypergraph with n vertices and m hyperedges. Let R be a random vertex set obtained by choosing each vertex of ${\mathcal{H}}$ independently with probability p. Let ${\mathcal{H}}[R]$ be the subhypergraph of ${\mathcal{H}}$ induced on R. We obtain an upper bound on the matching number ${\nu}({\mathcal{H}}[R])$ and a lower bound on the independence number ${\alpha}({\mathcal{H}}[R])$ of ${\mathcal{H}}[R]$. First, we show that if $mp^r{\geq}{\log}\;n$, then ${\nu}(H[R]){\leq}2e^{\ell}mp^r$ with probability at least $1-1/n^{\ell}$ for each positive integer ${\ell}$. It is best possible up to a constant factor depending only on ${\ell}$ if $m{\leq}n/r$. Next, we show that if $mp^r{\geq}{\log}\;n$, then ${\alpha}({\mathcal{H}}[R]){\geq}np-{\sqrt{3{\ell}np\;{\log}\;n}-2re^{\ell}mp^r$ with probability at least $1-3/n^{\ell}$.

Condensation heat transfer characteristics of hydrocarbon refrigerants R-290 and R-600a inside horizontal tubes (탄화수소계 냉매 R-290, R-600a의 수평관내 응축 열전달 특성에 관한 연구)

  • 박승준;박기원;노건상;정재천;오후규
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.1
    • /
    • pp.20-25
    • /
    • 2000
  • An experimental study on the condensation heat transfer coefficients of R-22, R-290 and R-600a inside horizontal tube was performed. Heat transfer measurements were performed for smooth tube with inside diameter of 10.07 mm and outside diameter of 12.07 mm and inner grooved tube having 75 fins whose height is 0.25 mm. This study was performed for condensation temperatures were from 308 K to 323 K, and mass velocity of $51 kg/m^2s - 250kg/m^2s$. The test results showed that the local condensation heat transfer coefficients increased as the mass flux increased, and also the effect of mass flow rate on heat transfer coefficients of R-290 was less than R-22. In addition, heat transfer coefficient of R-22 increased to a larger extent than R-290 and R-600a as the mass flow rate increased. Average condensation heat transfer coefficients of natural refrigerants were superior to that of R-22. The present results had a good agreement with Cavallini-Zecchin's correlation for smooth and inner grooved tubes.

  • PDF

Flow Boiling Heat Transfer Characteristics of R22 Alternative Refrigerants in a Horizontal Smooth Tube (R22 대체냉매의 수평원관내 흐름비등 열전달 특성)

  • 한재웅;김신종;정동수;김영일
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.4
    • /
    • pp.242-251
    • /
    • 2001
  • Flow boiling heat transfer coefficients (HTCs) of R22, R134a, R407C, and R410A were measured for a horizontal plain tube. The test section was made of a copper tube of 8.8mm inner diameter and 1000mm length respectively. The refrigerant was heated by passing hot water through an annulus surrounding the test section. All tests were performed at a fixed refrigerant saturation temperature of $5^{\circ}C$ with mass fluxes of 100~300 kg/$m^2$,/TEX>s. HTCs were measured by two methods: the direct wall temperature measurement method and the indirect Wilson plot method. Experimental results showed that the Wilson plot method was affected greatly by the external test conditions and yielded inconsistent results. For the mass flux of 100kg/$m^2$,/TEX>s, HTCs were almost constant regardless of the quality for a given refrigerant HTCs of R134a and R407C were similar to those of R22 while those of R410A were 60% higher than those of R22. For the mass fluxes of 200 and 300kg/$m^2$,/TEX>s, HTCs of R407C were almost the same as those of R22, while HTCs of R134a and R410A were 12-13% and 20~23% higher than those of R22 respectively. For pure refrigerant, Shah\`s correlation yielded a good agreement with the measured data both qualitatively and quantitatively.

  • PDF