• Title/Summary/Keyword: R. C. element

Search Result 452, Processing Time 0.035 seconds

Effect on Milking Performance of Vitamin-Trace Element Supplements to Early Lactation Italian Brown Cows Grazing Ryegrass (Lolium multiflorum) Pasture

  • Tufarelli, Vincenzo;Khan, R.U.;Laudadio, V.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.24 no.9
    • /
    • pp.1227-1232
    • /
    • 2011
  • The objective of this study was to examine the effects of concentrates containing different levels of a vitamin-trace elements premix on milk yield and composition of dairy cows. The trial, which lasted 14 weeks, was conducted from January to March and used 45 multiparous Brown cows in the early phase of lactation. Cows (n = 15 per treatment) were randomly allocated to three dietary treatments: the first group (control, C-0) was fed pelleted concentrate containing background vitamins and trace elements that supplied 1.0 times cows' daily requirements; the second group were fed the same concentrate, but containing 2.5 g/kg of vitamin and trace mineral premix per kg of concentrate (C-2.5); the third group were fed the same concentrate, but containing 5 g/kg of vitamin and trace mineral premix per kg of concentrate (C-5). The daily ration included ad libitum chopped oat hay, and the cows also had 8 h/d grazing on a ryegrass (Lolium multiflorum) pasture. During the performance trial, cow milk yield was daily recorded and individual milk samples were analysed for milk composition and to determine milk renneting properties. Cows fed the intermediate premix level (C-2.5) in diet showed the highest fat-corrected milk production (p<0.05) compared to other groups. None of the milk quality parameters studied were influenced by dietary treatment, except for milk rheological parameters (rennet clotting time and curd firmness) that were positively improved in cows fed the C-2.5 diet (p<0.05). The findings from this study show that intermediate level of vitamin-trace elements premix in concentrate can be advantageously used in grazing dairy cows without negative effects on yield and quality of milk produced.

The Practical Method and Experimental Verification of Temperature Estimation in the Permanent Magnet of Electric Machine

  • Kang, Kyongho;Yu, Sukjin;Lee, Geunho;Lee, Byeong-Hwa
    • Journal of Magnetics
    • /
    • v.20 no.4
    • /
    • pp.421-426
    • /
    • 2015
  • This paper presents a practical method for estimation of average temperature in the permanent magnet (PM) of electric machine by using finite element analysis (FEA) and dynamo load experiment. First of all, the temperature effect of PM to the torque has been employed by FEA in order to evaluate the Temperature-Torque characteristic curve. The 1st order polynomial equation which is torque attenuation coefficient is derived by the FEA result of the Temperature-Torque curve. Next, torque saturation test with constant current condition is performed by dynamo load experiment. Then, the temperature trend can be estimated by adding the initial starting temperature using the torque attenuation coefficient and torque saturation curve. Lastly, estimated temperature is validated by infrared thermometer which measures temperature of PM surface. The comparison between the estimated result and experimental result gives a good agreement within a deviation of maximum $8^{\circ}C$.

Comparision of the characteristics of 3-phase squirrel cage induction motor with slit and U-iron bridge type rotor slot (회전자 슬롯에 U자형 Iron bridge와 Slit이 있는 3상 농형 유도전동기의 특성비교)

  • Kim, B.T.;Kwon, B.I.;Park, S.C.;Kim, K.W.;Yoon, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07a
    • /
    • pp.41-43
    • /
    • 1997
  • This paper represents the comparison of harmonic loss characteristics of the inverter-driven 3-phase squirrel cage induction motor with slit and U-iron bridge slots of rotor. Two-dimensional time-stepped finite element method is used for electromagenetic field analysis. And spectrums of bar current, phase current, and torque are compared in each case.

  • PDF

Fatigue fracture of different dental implant system under cyclic loading (반복하중에 따른 수종 임플란트의 피로파절에 관한 연구)

  • Park, Won-Ju;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.4
    • /
    • pp.424-434
    • /
    • 2009
  • Statement of problem: Problems such as loosening and fractures of retained screws and fracture of implant fixture have been frequently reported in implant prosthesis. Purpose: Implant has weak mechanical properties against lateral loading compared to vertical occlusal loading, and therefore, stress analysis of implant fixture depending on its material and geometric features is needed. Material and methods: Total 28 of external hexed implants were divided into 7 of 4 groups; Group A (3i, FULL $OSSEOTITE^{(R)}$Implant), Group B (Nobelbiocare, $Br{\aa}nemark$ $System^{(R)}$Mk III Groovy RP), Group C (Neobiotec, $SinusQuick^{TM}$ EB), Group D (Osstem, US-II). The type III gold alloy prostheses were fabricated using adequate UCLA gold abutments. Fixture, abutment screw, and abutment were connected and cross-sectioned vertically. Hardness test was conducted using MXT-$\alpha$. For fatigue fracture test, with MTS 810, the specimens were loaded to the extent of 60-600 N until fracture occurred. The fracture pattern of abutment screw and fixture was observed under scanning electron microscope. A comparative study of stress distribution and fracture area of abutment screw and fixture was carried out through finite element analysis Results: 1. In Vicker's hardness test of abutment screw, the highest value was measured in group A and lowest value was measured in group D. 2. In all implant groups, implant fixture fractures occurred mainly at the 3-4th fixture thread valley where tensile stress was concentrated. When the fatigue life was compared, significant difference was found between the group A, B, C and D (P<.05). 3. The fracture patterns of group B and group D showed complex failure type, a fracture behavior including transverse and longitudinal failure patterns in both fixture and abutment screw. In Group A and C, however, the transverse failure of fixture was only observed. 4. The finite element analysis infers that a fatigue crack started at the fixture surface. Conclusion: The maximum tensile stress was found in the implant fixture at the level of cortical bone. The fatigue fracture occurred when the dead space of implant fixture coincides with jig surface where the maximum tensile stress was generated. To increase implant durability, prevention of surrounding bone resorption is important. However, if the bone resorption progresses to the level of dead space, the frequency of implant fracture would increase. Thus, proper management is needed.

Mechanical Splicing Characteristic of the Threaded Bar according to the Contact Conditions of the Transverse Rib (마디접촉조건에 따른 나사철근의 기계식 이음 특성)

  • Kim, J.M.;Choi, S.W.;Kim, B.M.
    • Transactions of Materials Processing
    • /
    • v.28 no.3
    • /
    • pp.145-153
    • /
    • 2019
  • The objective of this study is to analyze the mechanical splicing characteristic of the threaded bar according to the contact conditions of the transverse rib. In order to consider the contact conditions of the rib, selection of the main variables including the gap of the core diameter ($l_c$), rib angle (${\theta}$), and the number of contacts ($C_N$) of transverse rib was done. So as to analyze the splicing characteristic of the D51 threaded bar, a finite element (FE) simulation of the tensile test was conducted using the designed D51 threaded bar and coupler. Through FE simulation results, it was verified that the mechanical slicing characteristics varied based on the main design variables ($l_c$, ${\theta}$, and $C_N$). It was further confirmed that it was important to determine the $C_N$ in consideration of $l_c$. Additionally, the tensile test results of the D25 and D51 threaded bar combined with the couplers were similar to FE simulation results. Furthermore, to quantitatively evaluate FE simulation and test results, the calculation equation for the contacted projection area ratio (R) of the transverse rib was proposed. To secure a mechanical splicing joint of the threaded bar, it was established that the R calculated using the proposed equation had to be greater or equal to 40%.

Determination of CPT-based Bearing Capacity of Footings Under Surcharge Using State-dependent Finite Element Analysis (상태의존성 유한요소해석 및 CPT결과를 적용한 상재하중하의 얕은 기초의 지지력 결정)

  • Lee Jun-Hwan;Kim Dae-Ho;Park Dong-Gyu
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.7
    • /
    • pp.55-62
    • /
    • 2005
  • The use of the bearing capacity equation is subjected to several uncertainties. In this study, estimation of the bearing capacity of footings based on the cone resistance q$_{c}$ is investigated. Non-linear finite element analyses based on a state-dependent stress-strain model were performed to obtain the load-settlement responses of axially loaded circular footings. Various soil and footing conditions, including different relative densities, depths of embedment, and footing diameters were considered in the analyses. Based on the finite element results, load-settlement curves were obtained and used to determine the unit limit bearing capacity in terms of the cone resistance q$_{c}$ for footings subjected to surcharge. Values of the unit bearing capacity for different embedment depths were in a narrow range, while considerable variation was observed with relative density D$_{R}$. It was observed that the unit limit bearing capacity normalized with respect to q$_{c}$ decreases as D$_{R}$ increases for a given surcharge.

Analysis on the Behavior of Reticulated Root Piles for Reinforcing Footing using Computer Program (컴퓨터 프로그램을 이용한 기초보강용 그물식 뿌리말뚝의 거동 분석)

  • 박영호;변광욱
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1991.10a
    • /
    • pp.348-361
    • /
    • 1991
  • When reinforcing strip footing on a sand 8round with reticulated root piles, reinforcing effect depends on the length , number, cross sectional area, penetration angle, spacing, and Young's modulus of piles. the mode of action of reinfocement tendons in soil isn't one of carring developed tensile stresses but of anisotropic(uni-directional) reduction or even supression of one normal strain rate. R. H. Bassett and N. C. Last proposed that the reinforcement should be located on the direction of minor strain rate which coincides with the tensile strain rate in the velocity characteristics. Based on this proposal the author carried out a series of 2 - dimentional finite element analysis which varies the parameters mentioned above.

  • PDF

A Study on the Small Isolator Characteristics and Design of Mobile Phones (이동통신 단말기용 소형 아이솔레이터 특성 및 설계에 관한 연구)

  • 이영훈;권원현
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.2
    • /
    • pp.165-175
    • /
    • 2001
  • In this paper, it is analyzed lumped element isolators analytically by the analysis program using scattering matrixes including ferrite saturation magnetization, external direct current magnetic field and strip line length and width, designed and experimented the small isolator of mobile phone. The simulation results show that the characteristics of the isolator are affected by external R, C, length and width of strip line and ferrite width and saturation magnetization sensitivity. We proposed the isolator specification applied cellular and PCS mobile phones, experimented the isolator for cellular mobile phones. From the experimented result, isolation and return loss are measured below 20 dB, insertion loss is below 0.7 dB, bandwidth is about 44 MHz at center frequency 836.5 KHz. The implemented isolator has better performances than the conventional one.

  • PDF

Estimation of daily maximum air temperature using NOAA/AVHRR data (NOAA/AVHRR 자료를 이용한 일 최고기온 추정에 관한 연구)

  • 변민정;한영호;김영섭
    • Proceedings of the Korean Association of Geographic Inforamtion Studies Conference
    • /
    • 2003.04a
    • /
    • pp.291-296
    • /
    • 2003
  • This study estimated surface temperature by using split-window technique and NOAA/AVHRR data was used. For surface monitoring, cloud masking procedure was carried out using threshold algorithm. The daily maximum air temperature is estimated by multiple regression method using independent variables such as satellite-derived surface temperature, EDD, and latitude. When the EDD data added, the highest correlation shown. This indicates that EDD data is the necessary element for estimation of the daily maximum air temperature. We derived correlation and experience equation by three approaching method to estimate daily maximum air temperature. 1) non-considering landcover method as season, 2) considering landcover method as season, and 3) just method as landcover. The last approaching method shows the highest correlation. So cross-validation procedure was used in third method for validation of the estimated value. For all landcover type 5, the results using the cross-validation procedure show reasonable agreement with measured values(slope=0.97, intercept=-0.30, R$^2$=0.84, RMSE=4.24$^{\circ}C$). Also, for all landcover type 7, the results using the cross-validation procedure show reasonable agreement with measured values(slope=0.993, Intercept=0.062, R$^2$=0.84, RMSE=4.43$^{\circ}C$).

  • PDF

Study of Driving and Thermal Stability of Anode-type Ion Beam Source by Charge Repulsion Mechanism

  • Huh, Yunsung;Hwang, Yunseok;Kim, Jeha
    • Applied Science and Convergence Technology
    • /
    • v.27 no.3
    • /
    • pp.47-51
    • /
    • 2018
  • We fabricated an anode-type ion beam source and studied its driving characteristics of the initial extraction of ions using two driving mechanisms: a diffusion phenomenon and a charge repulsion phenomenon. For specimen exposed to the ion beam in two methods, the surface impurity element was investigated by using X-ray photoelectron spectroscopy. Upon Ar gas injection for plasma generation the ion beam source was operated for 48 hours. We found a Fe 2p peak 5.4 at. % in the initial ions by the diffusion mechanism while no indication of Fe in the ions released in the charge repulsion mechanism. As for a long operation of 200 min, the temperature of ion beam sources was measured to increase at the rate of ${\sim}0.1^{\circ}C/min$ and kept at the initial value of $27^{\circ}C$ for driving by diffusion and charge repulsion mechanism, respectively. In this study, we confirmed that the ion beam source driven by the charge repulsion mechanism was very efficient for a long operation as proved by little electrode damage and thermal stability.