• Title/Summary/Keyword: R-square

Search Result 1,555, Processing Time 0.034 seconds

Dielectric Waveguide Filters Design Embedded in PCB Substrates using Via Fence at Millimeter-Wave (밀리미터파 대역에서 Via Fence를 이용한 PCB 기판용 유전체 도파관 필터 설계)

  • 김봉수;이재욱;김광선;강민수;송명선
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.1
    • /
    • pp.73-80
    • /
    • 2004
  • In this paper, the implementation and embedding method of the existing air-filled waveguide-filters at millimeter-wave on general PCB substrate is introduced by systematically inserting the vias inside waveguide and mathematically manipulating the simple equations obtained ken the classical circular-post waveguide filter design. All the metal structures placed vertically such as side wall fur perfect ground plane and circular-post for signal control in the air-filled WR-22 waveguide are replaced with several types of via for constructing the bandpass-filter. Side wall and poles inside waveguide are realized by placing a series array of via and tuning the via diameter. The lengths of x, y, z axis are reduced in proportion to root square of employed substrate dielectric constant and especially the length of z axis can be more reduced due to the characteristics of the wave propagation. Because the mass production on PCB is possible without fabricating a large-scaled metal waveguide of WR-22 as input/output ports at millimeter-wave regime, the manufacturing cost is reduced considerably. Finally, when using multilayer process like LTCC for small-sized module, it is one of advantages to use only one layer f3r the filter fabrication. To evaluate the validity of this novel technique, order-3 Chebyshev BPF(Bandpass-Filter) centered at 40 GHz-band with a 2.5 % FBW (Fractional Bandwidth) were used. The employed substrate has relative dielectric constant of 2.2 and thickness of 10 mil of Rogers RT/Duroid 5880. Accroding to design and measurement results, a good performance of insertion loss of 2 ㏈ and return loss of -30 ㏈ is achieved at full input/output ports.

A Polarization-Switchable Microstrip Patch Antenna Using Corner Slots on Ground Plane and PIN Diodes (모서리 접지면 슬롯과 PIN 다이오드를 이용한 편파 변환 마이크로스트립 안테나)

  • Park, Chul-Woo;Lee, Tae-Hak;Choi, Jun-Ho;Yoon, Won-Sang;Pyo, Seong-Min;Kim, Young-Sik
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.7
    • /
    • pp.769-777
    • /
    • 2010
  • In this paper, a switchable circularly polarized microstrip patch antenna using PIN diodes and corner slots on ground plane is proposed at 2.4 GHz. The proposed antenna has a square microstrip patch and ground plane that consists of two pair of slots and PIN diodes. The electrical lengths of the slots are adjusted by using the switching characteristic of the PIN diode, so the polarization of the proposed antenna can be switchable between linear, left-handed(LH) and right-handed(RH). By separating the ground plane for the DC bias, the size reduction effect is also obtained. When the proposed antenna is operated as linear polarization, the return loss and impedance bandwidth are 15 dB, 59 MHz, and when operated as LH and RH polarization, the minimum axial ratio and 3-dB axial ratio bandwidth are 1.17 dB, 1.67 dB, 28 MHz, and 32 MHz, respectively.

A Study on the Post Occupancy Evaluation of Urban Grand Park with Reference to the Perception of Residents -Focused on Ulsan Grand Park's Efficiency and User's Satisfaction- (주민의식에 기초한 도시 대공원의 이용후 평가 -울산 대공원의 공원효율성 및 이용 만족도를 중심으로-)

  • 성백진;최종희;이재근;권오복
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.32 no.2
    • /
    • pp.11-24
    • /
    • 2004
  • The purpose of this study is to present data on the human activities responding to the physical environment of ‘Ulsan’s Grand Parks by evaluating user behavior and activity, visiting motivations, and user satisfaction. This study was conducted using multi-methods such as interviews and questionnaires surveys. The main findings of this study can be summarized in six parts as follows: \circled1 Behavior patterns showed that the users visited the park left within 30 minutes and the frequency of visits was 1 or 2 times per week. They spent their time mostly on ‘walking’ and ‘picnicking’. The users visited regardless of the seasons or the day of the week. \circled2 The priorities for improvements were analyzed as follows: the users expressed their demands for ‘shadowing facilities’ like shelters and pergolas because they used these facilities frequently. Also, the users would like an ‘event program’, ‘sign system’ and ‘guide program’. \circled3 Analysis of the the user’s perception of the park showed that they perceive the park as ‘representative source of the landscape and open space in Ulsan and place for making contact with nature. \circled4 In examining the visiting motivations of the users of Ulsan Grand Park, it was revealed that people use the park for ‘time with family and friends’, ‘to escape from city life’, ‘to relieve fatigue. As a result of factor analysis, 4 factors were identified such as ‘physical motive(MF1)’, ‘exploratory motive(MF2)’, ‘social motive(MF3)’ and ‘emotional motive(MF4). \circled5 Park users’ evaluation for park facilities showed that people are satisfied with most of the facilities and especially, they have high level of satisfaction for ‘footpaths’, ‘squares’ and ‘picnicspace’. The evaluation of the park user’s of activity reveals that they are content with nearly all the variables. Especially, they have high level of satisfaction for the variables of ‘convenience for dynamic activities’, ‘making of a beautiful atmosphere, ‘accessibility from the outside’ and, ‘convenience in group activitie. Factor analysis of the park user’s of activity revealed 5 factors such as ‘convenience and interest factor (AF1)’, ‘park maintenance, management and use program(AF2)’, ‘visual beauty(AF3)’, ‘safety and accessibility(AF4)’ and ‘crowding(AF5)’. \circled6 Regression analysis was employed to get the predictor factors of overall satisfaction with a result of 60.0%($R^2$). The variance was explained as ‘quality of the picnic space’, ‘convenience and interest factor while using the park’, ‘park program for maintain and management in the park’, ‘visually beauty while using the park’, ‘safety and accessibility of the parks’, ‘quality of the pond’, ‘crowding’, ‘quality of the square’.

Muscle Fatigue Assessment using Hilbert-Huang Transform and an Autoregressive Model during Repetitive Maximum Isokinetic Knee Extensions (슬관절의 등속성 최대 반복 신전시 Hilbert-Huang 변환과 AR 모델을 이용한 근피로 평가)

  • Kim, H.S.;Choi, S.W.;Yun, A.R.;Lee, S.E.;Shin, K.Y.;Choi, J.I.;Mun, J.H.
    • Journal of Biosystems Engineering
    • /
    • v.34 no.2
    • /
    • pp.127-132
    • /
    • 2009
  • In the working population, muscle fatigue and musculoskeletal discomfort are common, which, in the case of insufficient recovery may lead to musculoskeletal pain. Workers suffering from musculoskeletal pains need to be rehabilitated for recovery. Isokinetic testing has been used in physical strengthening, rehabilitation and post-operative orthopedic surgery. Frequency analysis of electromyography (EMG) signals using the mean frequency (MNF) has been widely used to characterize muscle fatigue. During isokinetic contractions, EMG signals present strong nonstationarities. Hilbert-Haung transform (HHT) and autoregressive (AR) model have been known more suitable than Fourier or wavelet transform for nonstationary signals. Moreover, several analyses have been performed within each active phase during isokinetic contractions. Thus, the aims of this study were i) to determine which one was better suitable for the analysis of MNF between HHT and AR model during repetitive maximum isokinetic extensions and ii) to investigate whether the analysis could be repeated for sequential fixed epoch lengths. Seven healthy volunteers (five males and two females) performed isokinetic knee extensions at $60^{\circ}/s$ and $240^{\circ}/s$ until 50% of the maximum peak torque was reached. Surface EMG signals were recorded from the rectus femoris of the right thigh. An algorithm detecting the onset and offset of EMG signals was applied to extract each active phase of the muscle. Following the results, slopes from the least-square error linear regression of MNF values showed that muscle fatigue of all subjects occurred. The AR model is better suited than HHT for estimating MNF from nonstationary EMG signals during isokinetic knee extensions. Moreover, the linear regression can be extracted from MNF values calculated by sequential fixed epoch lengths (p> 0.0I).

Effects of Supplemental Vegetable Oils on Ruminal Characteristics, Digestibility and Formation of Fatty Acid Soaps in Sheep (식물성유 첨가가 면양의 반추의 발효특성과 소화율 및 지방산염 형성에 미치는 영향)

  • Kim, D.I.;Choi, J.R.;Cho, S.H.;Lee, D.H.;Chung, T.Y.
    • Journal of Animal Science and Technology
    • /
    • v.46 no.5
    • /
    • pp.783-798
    • /
    • 2004
  • This experiment were conducted to determine the formation of fatty acid soaps, digestibility and ruminal characteristics when vegetable oils were added. Three Corriedale${\times}$ 3 Latin square design. Sheep were fed one of three diets consisting of alfalfa hay and concentrates in a ratio of 70:30. Dietary treatments were 1) no oil, 2) 7% soybean oil and 3) 7% corn oil. At the end of each experimental period, rumen contents from each sheep were collected before feeding and at 1, 3, 6 and 9h after feeding. pH decreased up to the 3 hour after feeding and increased until the end of the collection(p<0.0001). Whereas the concentration of $NH_3$-N showed inverse changes to pH(p<0.0001). Type of oil did not affect the molar concentration of total VFA, acetate, propionate and butyrate. Acetic/propionic acid (A/P) ratio decreased with increasing time(P<0.0001), but the ratio at the end of the experiment became similar to the initial value. No effects were found in the digestibility of dry matter, total-N, crude fiber, ash, NFE, NDF and ADF. The formation of fatty acid soaps(FAS) increased after feeding than 1 hour before feeding(P<0.05) and increased in 7% oils than no oil addition(P<0.05). Long chain fatty acids formed mainly FAS. ince the formation of FAS might decrease negative effects on ruminal haracteristics and total tract digestibility.

Combined 1D/2D Inundation Simulation of Riverside Farmland using HEC-RAS (HEC-RAS를 이용한 하천변 농경지의 1, 2차원 연계 침수 모의)

  • Jun, Sang Min;Song, Jung-Hun;Choi, Soon-Kun;Lee, Kyung-Do;Kang, Moon Seong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.60 no.5
    • /
    • pp.135-147
    • /
    • 2018
  • The objective of this study was to analyze the characteristics of combined 1D/2D inundation simulation of riverside farmland using the Hydrologic Engineering Center - River Analysis System (HEC-RAS). We compared and analyzed inundation simulation results between 1D and combined 1D/2D hydraulic simulation using HEC-RAS. Calibration and validation of stream stage were performed using three rainfall events. The coefficient of determination ($R^2$) and root mean square error (RMSE) between simulated and observed stream stage were 0.935 - 0.957 and 0.250 m - 0.283 m in calibration and validation, respectively. The inundation area showed no significant difference in 1D and combined 1D/2D simulation ($8.48km^2$ in 1D simulation, $8.75km^2$ in combined 1D/2D simulation). The average inundation depth by 1D simulation was 1.4 m deeper than combined 1D/2D simulation. In the lower inundation depth, the inundation area by combined 1D/2D simulation was larger than inundation area by 1D simulation. As the inundation depth increased, the inundation area by 1D simulation became wider. In the case of the 1D/2D combined simulation, low elevation areas along the river bank were inundated widely. Compared to 1D/2D combined simulation, the flood radius in some sections was longer in 1D simulation. In the 1D analysis, because the low altitude riverside farmlands are also assumed to stream, it is calculated that riverside farmlands have the same stage as the mainstream when the stream is overflowed. Therefore, the inundation area seems to be overestimated in those sections. In other regions, the inundation areas tend to be broken depending on overflow by each stream cross-section. In the case of river flooding, the overflow is expected to flow to the lower area depending on the terrain, such as the results of the combined 1D/2D simulation. It is concluded that the results of combined 1D/2D inundation simulation reflected the topographical characteristics of low-lying farmland.

Application of the Theory of Planned Behavior and the Theory of Reasoned Action to Predicting Cervix Cancer Screening Behavior (자궁암 조기검진행태 예측을 위한 계획된 행동이론과 이성적 행동이론의 적용)

  • Kim, Yong-Ik;Kim, Chang-Yup;Shin, Young-Soo;Lee, Kun-Sei
    • Journal of Preventive Medicine and Public Health
    • /
    • v.34 no.4
    • /
    • pp.379-388
    • /
    • 2001
  • Background : Cervix cancer is the most common form of cancer among Korea women. in spite of proof that cervical cancer screening could reduce death rates substantially, the screening rates reported by previous Korean studies remain stubbornly very low. Behavioral studies to increase the cervix cancer screening rate are essential in order to develop the cancer screening program. Objective : To evaluate the factors which are related to the intention and behavior for cervix cancer screening using the Theory of Planned Behavior (TPB) and the Theory of Reasoned Action (TRA). Methods : The survey was conducted from July 21 st to 26th in 1998. Of 3,218 women, 303(12.2%) between 30 and 55 years old, voluntarily participated in the survey in the 3 Myeons in Choongju city. Charge-free cervix cancer screening was provided for the subjects 3 months later. Results : The R-square of both TPB and TRA to the intention (30% and 42%, respectively) was greater than the actual behavior (21% and 13%, respectively. TPB and TRA were found to provide an appropriate framework for the study of cervix cancer screening behavior. However, TRA was more powerful in explaining the intention, not only because the perceived behavioral control component exhibited lower reliability and validity than other components(altitude and subjective norm), but also because there may have been a few limitations in this study design. Consequently, the use of TRA is preferred in attempting to explain intention and actual behavior in this study. Conclusions : This study suggests that a successful intervention program should focus on changing attitudes and reducing psychologic barriers, rather than on just providing information. Physician recommendations, and the support of family members and friends are also very important factors in cervix cancer program participation. Physicians, friends, family members, and opinion leaders in rural areas, all of whom could affect the individual subjective norm, may all have the potential to play great roles as facilitators.

  • PDF

Development and Evaluation of Korean Diagnosis Related Groups: Medical service utilization of inpatients (한국형 진단명기준환자군의 개발과 평가: 입원환자의 의료서비스 이용을 중심으로)

  • Shin, Young-Soo;Lee, Young-Seong;Park, Ha-Young;Yeom, Yong-Kwon
    • Journal of Preventive Medicine and Public Health
    • /
    • v.26 no.2 s.42
    • /
    • pp.293-309
    • /
    • 1993
  • With expanded and extended coverage of the national medical insurance and fast growing health care expenditures, appropriateness of health service utilization and quality of care are concerns of both health care providers and insurers as well as patients. An accurate patient classification system is a basic tool for effective health care policies and efficient health services management. A classification system applicable to Korean medical information-Korean Diagnosis Related Groups (K-DRGs)-was developed based on the U.S. Refined DRGs, and the performance of the developed system was assessed in this study. In the process of the development, first the Korean coding systems for diagnoses and procedures were converted to the systems used in the definition of the U.S. Refined DRGs using the mapping tables formulated by physician panels. Then physician panels reviewed the group definition, and identified medical practice patterns different in two countries. The definition was modified for the differences in K-DRGs. The process resulted in 1,199 groups in the system. Several groups in Refined DRGs could not be differentiated in K-DRGs due to insufficient medical information, and several groups could not be defined due to procedures which were not practiced in Korea. However, the classification structure of Refined DRGs was retained in K-DRGs. The developed system was evaluated fur its performance in explaining variations in resource use as measured by charges and length of stay(LOS), for both all and non-extreme discharges. The data base used in this evaluation included 373,322 discharges which was a random sample of discharges reviewed and payed by the medical insurance during the five-month period from September 1990. The proportion of variance in resource use which was reduced by classifying patients into K-DRGs-r-square-was comparable to the performance of the U.S. Refined DRGs: .39 for charges and .25 for LOS for all discharges, and .53 for charges and .31 for LOS for non-extreme discharges. Another measure analyzed to assess the performance was the coefficient of variation of charges within individual K-DRGs. A total of 966 K-DRGs (87.7%) showed a coefficient below 100%, and the highest coefficient among K-DRGs with more than 30 discharges was 159%.

  • PDF

Establishment of Thermal Infrared Observation System on Ieodo Ocean Research Station for Time-series Sea Surface Temperature Extraction (시계열 해수면온도 산출을 위한 이어도 종합해양과학기지 열적외선 관측 시스템 구축)

  • KANG, KI-MOOK;KIM, DUK-JIN;HWANG, JI-HWAN;CHOI, CHANGHYUN;NAM, SUNGHYUN;KIM, SEONGJUNG;CHO, YANG-KI;BYUN, DO-SEONG;LEE, JOOYOUNG
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.22 no.3
    • /
    • pp.57-68
    • /
    • 2017
  • Continuous monitoring of spatial and temporal changes in key marine environmental parameters such as SST (sea surface temperature) near IORS (Ieodo Ocean Research Station) is demanded to investigate the ocean ecosystem, climate change, and sea-air interaction processes. In this study, we aimed to develop the system for continuously measuring SST using a TIR (thermal infrared) sensor mounted at the IORS. New SST algorithm is developed to provide SST of better quality that includes automatic atmospheric correction and emissivity calculation for different oceanic conditions. Then, the TIR-based SST products were validated against in-situ water temperature measurements during May 17-26, 2015 and July 15-18, 2015 at the IORS, yielding the accuracy of 0.72-0.85 R-square, and $0.37-0.90^{\circ}C$ RMSE. This TIR-based SST observing system can be installed easily at similar Ocean Research Stations such as Sinan Gageocho and Ongjin Socheongcho, which provide a vision to be utilized as calibration site for SST remotely sensed from satellites to be launched in future.

A Study on the Global Co-movement & Spillover Effect of Housing Price (주택가격의 글로벌 동조화와 파급경로에 관한 연구)

  • Chang, Young Gil
    • Korea Real Estate Review
    • /
    • v.24 no.1
    • /
    • pp.39-52
    • /
    • 2014
  • This study examines the degree of global co-movement & spillover effect among the housing price of ten major countries of OECD including Korea, based on the 3 hypothesis. The data used in this study is quarterly house price index of OECD countries from 1975 to 2012. VAR model is used to analyze the co-movement, and Granger causality methodology is used for the analysis of Spillover Effect. It is found that entire period of study is that the global house prices showed the co-movement, but the coefficient was weak. Since 2008 global financial crisis, the co-movement increased significantly and the adjusted R-square of this model increased 78% compared to the entire period (1975-2012). In general, all hypotheses in this study were significant, and the common shock hypothesis were most significant. In case of Korea, the degree of co-movement was weak compared to the other countries and spillover effect was independent since 2008.