• Title/Summary/Keyword: R-mode System

Search Result 439, Processing Time 0.028 seconds

Determination of Minimal Pressure Support Level During Weaning from Pressure Support Ventilation (압력보조 환기법으로 기계호흡 이탈시 최소압력보조(Minimal Pressure Support) 수준의 결정)

  • Jung, Bock-Hyun;Koh, Youn-Suck;Lim, Chae-Man;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.2
    • /
    • pp.380-387
    • /
    • 1998
  • Background: Minimal pressure support(PSmin) is a level of pressure support which offset the imposed work of breathing(WOBimp) developed by endotracheal tube and ventilator circuits in pressure support ventilation While the lower applied level of pressure support compared to PSmin could induce respiratory muscle fatigue, the higher level than PSmin could keep respiratory muscle rest resulting in prolongation of weaning period during weaning from mechanical ventilation PSmin has been usually applied in the level of 5~10 cm$H_2O$, but the accurate level of PSmin is difficult to be determinated in individual cases. PSmin is known to be calculated by using the equation of "PSmin = peak inspiratory flow rate during spontaneus ventilation$\times$total ventilatory system resistance", but correlation of calculated PSmin and measured PSmin has not been known. The objects of this study were firstly to assess whether customarily applied pressure support level of 5~10 cm$H_2O$ would be appropriate to offset the imposed work of breathing among the patients under weaning process, and secondly to estimate the correlation between the measured PSmin and calculated PSmin. Method : 1) Measurement of PSmin : Intratracheal pressure changes were measured through Hi-Lo jet tracheal tube (8mm in diameter, Mallinckroft, USA) by using pulmonary monitor(CP-100 pulmonary monitor, Bicore, USA), and then pressure support level of mechanical ventilator were increased until WOBimp was reached to 0.01 J/L or less. Measured PSmin was defined as the lowest pressure to make WOBimp 0.01 J/L or less. 2) Calculation of PSmin : Peak airway pressure(Ppeak), plateau airway pressure(Pplat) and mean inspiratory flow rate of the subjects were measured on volume control mode of mechanical ventilation after sedation. Spontaneous peak inspiratory flow rates were measured on CPAP mode(O cm$H_2O$). Thereafter PSmin was calculated by using the equation "PSmin = peak inspiratory flow rate$\times$R, R = (Ppeak-Pplat)/mean inspiratory flow rate during volume control mode on mechanical ventilation". Results: Sixteen patients who were considered as the candidate for weaning from mechanical ventilation were included in the study. Mean age was 64(${\pm}14$) years, and the mean of total ventilation times was 9(${\pm}4$) days. All patients except one were males. The measured PSmin of the subjects ranged 4.0~12.5cm$H_2O$ in 14 patients. The mean level of PSmin was 7.6(${\pm}2.5\;cmH_2O$) in measured PSmin, 8.6 (${\pm}3.25\;cmH_2O$) in calculated PSmin Correlation between the measured PSmin and the calculated PSmin is significantly high(n=9, r=0.88, p=0.002). The calculated PSmin show a tendancy to be higher than the corresponding measured PSmin in 8 out of 9 subjects(p=0.09). The ratio of measured PSmin/calculated PSmin was 0.81(${\pm}0.05$). Conclusion: Minimal pressure support levels were different in individual cases in the range from 4 to 12.5 cm$H_2O$. Because the equation-driven calculated PSmin showed a good correlation with measured PSmin, the application of equation-driven PSmin would be then appropriate compared with conventional application of 5~10 cm$H_2O$ in patients under difficult weaning process with pressure support ventilation.

  • PDF

Evaluation of Groundwater Quality Using Factor Aanlyses and Agrochemicals in an Agricultural Area (요인분석과 농약성분 특성에 의한 농업지역의 지하수 수질 평가)

  • Lee, Jeong-Hwan;Hamm, Se-Yeong;Kim, Kwang-Sung;Cheong, Jae-Yeol;Ryu, Sang-Min;Kim, Deuk-Ho;Kim, Hyun-Ji
    • Economic and Environmental Geology
    • /
    • v.42 no.3
    • /
    • pp.217-234
    • /
    • 2009
  • This study characterized groundwater quality and the influence of agrochemicals in a part of Ilgwang-Myeon agricultural area in Gijang-Gun, Busan Metropolitan City, using factor analyses. From the 1st, 2nd, and 3rd analyses of groundwater samples, the mean concentrations of $Ca^{2+}$, $Na^+$, $Mg^{2+}$, $K^+$, $Zn^{2+}$, $Cu^{2+}$, $Fe^{2+}$, $Al^{3+}$, $NO_3\;^-$, $Cl^-$, $SO_4\;^{2-}$, $F^-$, and $SiO_2$ were higher in the 2nd analysis than the other analyses. Pesticide carbofuran and herbicide alachlor were detected at the wells more than a half of all the wells in the 2nd analysis but not in the 4th analysis. This fact may be explained by that a higher precipitation induced higher infiltration rate of contaminants into groundwater during the 2nd survey. According to R- and Q-mode factor analyses, and chemical composition, inorganic constituents excepting $SiO_2$, $HC0_3\;^-$-, and $F^-$ may be influenced by anthropogenic sources (manures, synthetic fertilizers, and domestic wastes), seawater as well as water-mineral interaction. A typical indicator of groundwater contamination, nitrate, exceeds around 4-5 times over the Korean standard for drinking water. Additionally, the influence of seawater diminishes from the seaside to inland.

An Experimental Study of the Soil Nailed Wall Behavior with Front Plate Rigidity (전면벽체 강성에 따른 쏘일네일링 벽체의 거동특성에 관한 실험적 고찰)

  • Kim, Hong-Taek;Kang, In-Kyu;Kwon, Young-Ho;Park, Si-Sam;Cho, Yong-Hoon
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.3
    • /
    • pp.87-94
    • /
    • 2002
  • Recently, there have been numerous attempts to expand the traditional temporary soil nailing system into a permanent wall. Two reasons for this include the soil nailed system's advantage of efficient and economic use of subgrade space and its ability to decrease the total construction cost. However, the systematic and logical design approach has not been proposed yet. The permanent soil nailing wall system, which utilizes precast concrete from soil nailing system, is already used in many countries, but the study of cast-in-place concrete lacing or rigid walls in bottom-up construction of traditional soil nailing walls is imperfect and insufficient. In this paper, various laboratory model tests have been carried out to investigate the influence of parameters, including stiffness of the rigid wall to the soil nailing structure with respect to failure mode, displacement patterns and tensile forces at the nail head in several levels of load. Then, the variation of earth pressure distribution on the soil nailing wall, built with a rigid front plate, is sought through different levels of surcharge load and tensile forces at the nail head.

Study of the possible mode of action of O-ethyl S-methyl ethylphosphonothioate via the formation of S-oxide in chemical and metabolic oxidation systems (화학적, 대사적 산화반응 중 생성되는 S-oxide를 이용한 O-ethyl S-methyl ethylphosphonothioate (1) 의 독성 기작에 관한 연구)

  • Hur, J.H.;Fukuto, T.R.;Han, D.S.
    • Korean Journal of Environmental Agriculture
    • /
    • v.10 no.2
    • /
    • pp.167-177
    • /
    • 1991
  • O-ethyl S-methyl ethylphosphonothioate [$LD_{50}$ (rat, oral) 4.6mg/kg ; $K_i$(bovine erythrocyte acetylcholinesterase) 303 $M^{-1\;min-1}$] was selected as a model compound to study the mode of action of O, S-dialkyl alkylphosphonothioates which have been hypothesized to be toxic via a bioactivation process. Two chemical oxidants, meta-chloroperoxybenzoic acid and monoperoxyphthalic acid, and rat liver microsomal oxidases were used to mimic the action of mixed function oxidases on the model compound. The formation of S-oxide, a very unstable active intermediate, was proposed based on the identification of metabolic products.Furthermore, a trapping experiment with ethanol showed that the unstable intermediate S-oxide had the ability to phosphorylate acetylcholinesterase which is an important enzyme in nerve systems. The S-oxide intermediates are presumed to be responsible for the toxicity of O,S-dialkyl alkylphosphonothioates.

  • PDF

Developing a Dental Unit Waterline Model Using General Laboratory Equipments (실험실 일반 장비를 이용한 치과용 유니트 수관 모델 개발)

  • Yoon, Hye Young;Lee, Si Young
    • Journal of dental hygiene science
    • /
    • v.16 no.4
    • /
    • pp.284-292
    • /
    • 2016
  • Water supplied through dental unit waterlines (DUWLs) has been shown to contain high number of bacteria. To reduce the contamination of DUWLs, it is essential to develop effective disinfectants. It is, however, difficulty to obtain proper DUWL samples for studies. The purpose of this study was to establish a simple laboratory model for reproducing DUWL biofilms. The bacteria obtained from DUWLs were cultured in R2A liquid medium for 10 days, and then stored at $-70^{\circ}C$. This stock was inoculated into R2A liquid medium and incubated in batch mode. After 5 days of culturing, it was inoculated into the biofilm formation model developed in this study. Our biofilm formation model comprised of a beaker containing R2A liquid medium and five glass rods attached to DUWL polyurethane tubing. Biofilm was allowed to form on the stir plate and the medium was replaced every 2 days. After 4 days of biofilm formation in the laboratory model, biofilm thickness, morphological characteristics and distribution of the composing bacteria were examined by confocal laser microscopy and scanning electron microscopy. The mean of biofilm accumulation was $4.68{\times}10^4$ colony forming unit/$cm^2$ and its thickness was $10{\sim}14{\mu}m$. In our laboratory model, thick bacterial lumps were observed in some parts of the tubing. To test the suitability of this biofilm model system, the effectiveness of disinfectants such as sodium hypochlorite, hydrogen peroxide, and chlorhexidine, was examined by their application to the biofilm formed in our model. Lower concentrations of disinfectants were less effective in reducing the count of bacteria constituting the biofilm. These results showed that our DUWL biofilm laboratory model was appropriate for comparison of disinfectant effects. Our laboratory model is expected to be useful for various other purposes in further studies.

MICROTENSILE BOND STRENGTH OF ALL-IN-ONE ADHESIVE TO CARIES-AFFECTED DENTIN (우식이환 상아질에 대한 all-in-one adhesive의 미세인장결합강도)

  • Moon, Ji-Deok;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.1
    • /
    • pp.49-57
    • /
    • 2005
  • The purpose of this study was to evaluate the effect of multiple application of all-in-one dentin adhesive system on microtensile bond strength to caries-affected dentin. Twenty one extracted human molars with occlusal caries extending into mid-dentin were prepared by grinding the occlusal surface flat. The carious lesions were excavated with the aid of caries detector dye. The following adhesives were applied to caries-affected dentin according to manufacturer's directions; $Scotchbond^{TM}$ Multi-Purpose in SM group, Adper Prompt $L-Pop^{TM}$ 1 coat in LP1 group, 2 coats in LP2 group, 3 coats in LP3 group, $Xeno^{(R)}$ III 1 coat in XN1 group, 2 coats in XN2 group. and 3 coats in XN3 group. After application of the adhesives, a cylinder of resin-based composite was built up on the occlusal surface. Each tooth was sectioned vertically to obtain the $1{\times}1\;mm^2$ sticks. The microtensile bond strength was determined. Each specimen was observed under SEM to examine the failure mode. Data were analyzed with one-way ANOVA. The results of this study were as follows; 1. The microtensile bond strength values were; SM ($14.38{\pm}2.01$ MPa), LP1 ($9.15{\pm}1.81$ MPa), LP2(14.08{\pm}1.75$ MPa), LP3 ($14.06{\pm}1.45$ MPa). XN1 (13.65{\pm}1.95$ MPa). XN2 ($13.98{\pm}1.60$) MPa, XN3 ($13.88{\pm}1.66$) MPa, LP1 was significantly lower than the other groups in bond strength (p < 0.05). All groups except LP1 were not significantly different in bond strength (p > 0.05). 2. In LP1, there were a higher number of specimens showing adhesive failure. Most specimens of all groups except LP1 showed mixed failure.

Prediction of a Structural Vibration and Radiated Noise of High-voltage Transformer through Force Identification (가진력 규명을 통한 초고압 변압기의 구조진동 및 방사소음 예측)

  • Yoo, Suk-Jin;Jung, Byung-Kyoo;Jeong, Weui-Bong;Hong, Chinsuk;Kim, Tae-Yong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.6
    • /
    • pp.527-536
    • /
    • 2013
  • In order to predict structural vibration and radiated noise of high-voltage transformer in operation, it is necessary to precisely find the excitation force generated by the coils and core. However, finding the excitation force through experiments of high voltage transformer in operation is not possible. Therefore, this paper deals with identifying the excitation force by using the acceleration data measured through experiments and the transfer function estimated through finite element model. A method to predict structural vibration and radiated noise was also proposed. Three-phase windings and the core are the source of high-voltage transformer. The excitation forces were identified using the acceleration data and the transfer function of the surface of the tank. Structural vibration and radiated noise from the surface of the tank was predicted by using the identified excitation force. As a result of the interpretation of the experimental and computational analysis of structural vibration from the surface of the tank and radiated noise from the field point, the interpretation of the computational analysis showed relatively good accordance with the experiment.

Seismic assessment of transfer plate high rise buildings

  • Su, R.K.L.;Chandler, A.M.;Li, J.H.;Lam, N.T.K.
    • Structural Engineering and Mechanics
    • /
    • v.14 no.3
    • /
    • pp.287-306
    • /
    • 2002
  • The assessment of structural performance of transfer structures under potential seismic actions is presented. Various seismic assessment methodologies are used, with particular emphasis on the accurate modelling of the higher mode effects and the potential development of a soft storey effect in the mega-columns below the transfer plate (TP) level. Those methods include response spectrum analysis (RSA), manual calculation, pushover analysis (POA) and equivalent static load analysis (ESA). The capabilities and limitations of each method are highlighted. The paper aims, firstly, to determine the appropriate seismic assessment methodology for transfer structures using these different approaches, all of which can be undertaken with the resources generally available in a design office. Secondly, the paper highlights and discusses factors influencing the response behaviour of transfer structures, and finally provides a general indication of their seismic vulnerability. The representative Hong Kong building considered in this paper utilises a structural system with coupled shear walls and moment resisting portal-frames, above and below the TP, respectively. By adopting the wind load profile stipulated in the Code of Practice on Wind Effects: Hong Kong-1983, all the structural members are sized and detailed according to the British Standards BS8110 and the current local practices. The seismic displacement demand for the structure, when built on either rock or deep soil sites, was determined in a companion paper. The lateral load-displacement characteristic of the building, determined herein from manual calculation, has indicated that the poor ductility (brittle nature) of the mega-columns, due mainly to the high level of axial pre-compression as found from the analysis, cannot be effectively alleviated solely by increasing the quantity of confinement stirrups. The interstorey drift demands at lower and upper zones caused by seismic actions are found to be substantially higher than those arising from wind loads. The mega-columns supporting the TP and the coupling beams at higher zones are identified to be the most vulnerable components under seismic actions.

Toxicokinetics of 4-tert-octylphenol in rats (Rat에서의 Octylphenol의 독성동태 연구)

  • 손수정;강현구;이선우;서수경;박인숙;안미령;최홍석;조재민;손동환
    • Environmental Mutagens and Carcinogens
    • /
    • v.21 no.2
    • /
    • pp.122-127
    • /
    • 2001
  • 4-tert-octylphenol (OP) is a surfactant additive widely used in the manufacture of a variety of detergents and plastic products. Also, OP is known to have estrogenic activity by interacting with development and functions of endocrine system. This study was carried out to obtain toxicokinetic parameters of OP in male Sprague-Dawley rats. Male rats were administered OP, by either single oral (gavage) applications of 50, 100 or 200 mg/kg body weight. or a single intravenous injections of 1, 5 or 10 mg/kg body weight. Blood samples taken at several time intervals after administration were obtained from the femoral artery. Analysis of blood samples for OP was performed by gas chromatography mass spectrometry (GC/MS). The detection limit of OP was 1.9 ng/$m\ell$ at SIM (selected ion monitoring) mode of GC/MS. Calibration curve for analysis of the concentrations of OP in plasma was (OP/butylphenol peak area ratio) = 0.0294 $\times$ (plasma cone.) + 0.028 ($r^2$= 0.9991). The OP plasma concentration was 3921 ng/$m\ell$ immediately after single intravenous application, decreased rapidly within 45 min, and was detectable at low concentration up to 6 hr after application. When administered orally in rats (50, 100 and 200 mg/kg), OP was detected in the blood early after gavage administration, indicating the rapid initial uptake from gastrointestinal tract, with Tmax obtained from 0.67~0.83 hr. Using the AUC (area under the curve) of plasma concentration vs. time, low oral bioavailabilities of 1.2, 5.0 and 5.3% were calculated for the 50, 100 and 200 mg/kg groups, respectively.

  • PDF

A Study on Tensile Shear Characteristics of Dissimilar Joining Between Pre-coated Automotive Metal Sheets and Galvanized Steels with the Self-Piercing Rivet and Hybrid Joining (Self-Piercing Rivet과 Hybrid Joining을 이용한 자동차용 선도장 칼라강판과 용융아연도금강판의 접합부 기계적 성질 평가)

  • Bae, Jin-Hee;Kim, Jae-Won;Choi, Ildong;Nam, Dae-Geun;Kim, Jun-Ki;Park, Yeong-Do
    • Journal of Welding and Joining
    • /
    • v.34 no.1
    • /
    • pp.59-67
    • /
    • 2016
  • The automotive manufactures increase their use of lightweight materials to improve fuel economy and energy usage has a significant influence on the choice of developing materials. To meet this requirements manufacturers are replacing individual body parts with lightweight metals, for these the process treating and painting surfaces is changing. The pre-coated steels are newly developed to avoid the conventional complex and non-environmental painting process in the body-in-white car manufacturing. The development of new joining techniques is critically needed for pre-coated steel sheets, which are electrically non-conductive materials. In the present study, dissimilar combination of pre-coated steel and galvanized steel sheets were joined by the self-piercing rivet, adhesive bonding and hybrid joining techniques. The tensile shear test and free falling high speed crash test were conducted to evaluate the mechanical properties of the joints. The highest tensile peak load with large deformation was observed for the hybrid joining process which has attained 48% higher than the self-piercing rivet. Moreover, the hybrid and adhesive joints were observed better strain energy compared to self-piercing rivet. The fractography analyses were revealed that the mixed mode of cohesive and interfacial fracture for both the hybrid and adhesive bonding joints.