• Title/Summary/Keyword: R-mode System

Search Result 439, Processing Time 0.027 seconds

Control System of 600kW EBOP for Molten Carbonate Fuel Cell Generation System (600kW급 용융탄산염 연료전지 발전시스템용 EBOP 제어시스템)

  • Hwang, Tai-Sik;Joung, Woo-Taek;Yang, Byung-Hoon;Kim, Kwang-Seob;Kwon, Byung-Ki;Choi, Chang-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.18-20
    • /
    • 2008
  • An electrical balance of plant(EBOP) of a 600kW molten carbonate fuelcell (MCFC) has to transit from grid-connected(GC) mode to grid-independent(GI) mode when a grid is in a fault conditions. A minimum transition time is limited by four cycle for a 600kW MCFC to ride through a grid fault. In this paper, we propose a control algorithm of a 600kW EBOP for a MCFC system. The EBOP has three operation modes, i.e., GC mode, GI mode, and grid-synchronized(GS) mode. The EBOP controls output currents in a GC mode and regulates output voltages in GI or GS mode. GS mode is defined as an interface between GC mode and GI mode to make a mode transition smooth, i.e., limitation of inrush currents, regulation of output voltages within ANSI standard. Simulations and experiments carried out to verify the effectiveness of the proposed control algorithm.

  • PDF

Development of MF R-Mode Transmitting System for Maritime Resilient PNT in the Republic of Korea

  • Han, Younghoon;Son, Pyo-Woong;Seo, Kiyeol;Fang, Tae Hyun
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.11 no.4
    • /
    • pp.239-244
    • /
    • 2022
  • R-Mode is terrestrial based Global Navigation Satellite System (GNSS) backup radio navigation technology which used existing maritime information service infrastructure. It has advantages on reduce the cost and reutilize the frequency resource. In this paper, we propose a method to develop a medium-frequency (MF) band R-Mode transmitting station by utilizing the currently operating Differential GNSS (DGNSS) reference station infrastructure. To this end, the considerations for co-operating the DGNSS reference station and the MF R-Mode transmitting station are analyzed. In this process, we also analyze what is necessary to configure the communication system as a navigation system for range measurement. Based on the analysis result, MF R-Mode transmitting station system is designed and architecture is proposed. The developed system is installed in the field, and the performance evaluation results is presented.

Mark XIIA(Mode 5) IFF System Integration and Certification Test for Surface to Air Missile System (유도무기체계 모드 5 피아식별 체계통합 및 인증시험)

  • Kim, Woo-Hyun;Jung, Se-Young;Lee, Yun-Soo;Chang, Se-Myong
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.25 no.2
    • /
    • pp.160-168
    • /
    • 2022
  • The new IFF mode, Mode-5 replacing Mode-4, has already been established by the US DoD for its allies and NATO forces. A IFF retrofit program for replacing the Mark XII Mode-4 with Mark XIIA Mode-5 is in progress in order to overcome the security limitations of the former in R.O.K. IFF certification test for the new mode, Mode-5, has been performed on medium range surface to air missile platform of the Korean armed forces for the first time in R.O.K and this is regarded as a monumental event in Korean defense industry. The present paper is a discussion on the procedures applied to the IFF system retrofit and integration, lessons learned from AIMS test with the US AIMS PO as observer. The minimum modification from the existing Mark XII Mode-4 to Mark XIIA Mode-5 and evolutional adaption from previous design including interoperability are required for the system retrofit. Letter of Certification was received from the US AIMS PO after the tests. The authors propose that the lessons learned and know-how acquired during the tests are managed by the R.O.K Government as the standard structure of a database. It is expected that the use of the database will reduce the developmental difficulties and risk, also increase efficiency in future developments and other projects.

Analysis of Propagation Environment for Selecting R-Mode Reference and Integrity Station (R-Mode 보정국과 감시국 선정을 위한 전파환경 분석에 관한 연구)

  • Jeon, Joong-Sung;Jeong, Hae-Sang;Gug, Seung-Gi
    • Journal of Navigation and Port Research
    • /
    • v.45 no.1
    • /
    • pp.26-32
    • /
    • 2021
  • In ocean field, the spread of the Fourth Industrial Revolution based on information and communication technology requires high precision and stable PNT&D (Position, Navigation, Timing and Data). As the IMO (International Maritime Organization) and IALA (The International Association of Marine Aids to Navigation and Lighthouse Authorities) are requiring backup systems due to mitigate vulnerabilities and the increase of dependency on GNSS (Global Navigation Satellite System), Korea is conducting a research & development of R-Mode. An DGPS (Differentiate Global Positioning System) reference station that uses MF, an existing maritime infrastructure, and AIS (Automatic Identification System) base stations that use 34 integrity station and VHF will be utilized in this study to avoid redundant investment. Because there are radio shadow areas that display low signal levels in the west sea, the establishment of new R-Mode reference and integrity station will be intended to resolve problems regrading the radio shadow area. Because the frequency has a characteristic in that radio wave transmits well along the ground (water surface) in low frequency band, simulation and measurement were conducted therefore this paper to propose candidate sites for R-Mode reference and integrity station resulted through p wave's propagation characteristics analysis. Using this paper, R-Mode reference and integrity station can be established at appropriate locations to resolve radio shadow areas in other regions.

Experimental Study on the Mutual Influence of Thermal Management System for Hydrogen Fuel Cell Vehicle (수소연료전지 자동차 열관리 시스템의 상호 영향도 분석을 위한 실험적 연구)

  • Lee, Moo-Yeon;Won, Jong-Phil;Cho, Choong-Won;Lee, Ho-Seong
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.22 no.6
    • /
    • pp.852-858
    • /
    • 2011
  • This paper is aiming to estimate the mutual influence of the stack cooling performances with the operation modes of the thermal management system for the hydrogen fuel cell vehicles. The heat capacity of the thermal management system was measured by varying the operating modes such as stack cooling heat exchanger only (Mode 1), stack cooling and electric devices cooling heat exchangers (Mode 2), and stack cooling and electric devices cooling heat exchangers with an operation of the condenser (Mode 3).As the results, Performance of the thermal management system (TMS) at Mode 3 decreased up to 34.0%, compared with the result of the Mode 1. In addition, in order to optimize the performance of TMS, the entropy change of stack cooling heat exchanger using irreversibility analysis technique was analyzed with the relationship between entropy generation and entering air velocity of the thermal management system.

Captive Flight Test System Configuration and Verification for Multi-mode Guidance Missile System (복합유도방식이 적용된 유도탄의 탑재비행시험(CFT) 시스템 구성 및 검증)

  • Park, Inchul;Heo, Wonyoung;Lee, Yongho;Jeong, Seyoung
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.606-612
    • /
    • 2016
  • A Captive Flight Test(CFT) is used to verify the performance of missile component such as seeker and guiding algorithm of missile. Recently most of surface to air missile adapts multi-mode guidance method which include command guidance and active/passive guidance. A CFT system for missile system adapting multi-mode guidance method consists of pod equipment, command transmitting system and measuring system. In this paper, we proposed CFT system and testing method for missile which adapt multi-mode guidance, and system integration procedure by using distributed missile system integration method and procedure. The proposed CFT system and system integration method was applied to CFT of surface to air missile, and brought successful result.

Development of An Accelerated Durability Test Mode for Fuel Cell (연료전지 가속내구모드 개발)

  • LEE, YONGHEE;OH, DONGJO;JEON, UISIK;LEE, JONGHYUN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.26 no.5
    • /
    • pp.493-498
    • /
    • 2015
  • The fuel cell vehicle is a type of hydrogen vehicle which uses a fuel cell to produce electricity, powering its on-board electric motor. The fuel cell vehicle driving principle is completely different from the internal combustion engine vehicle. In order to ensure the durable quality of the fuel cell vehicle, durability test mode considering the characteristics of the fuel cell must be developed. In this study, we derived the durability test mode profile through collecting and analyzing fuel cell vehicle driving data. Then, the accelerated durability test mode is developed by adding degradation conditions and is experimentally validated to have an acceleration factor of 5~6.

지상파 기반 항법을 위한 VDES-TER 활용방안에 대한 연구

  • 김혜진;한재웅;김원용;유진호
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2023.11a
    • /
    • pp.202-204
    • /
    • 2023
  • 제 4차 산업혁명의 도래로 해양 분야에서도 해양산업혁명의 대표 분야인 자율운항선박에 대한 연구개발이 활발히 진행 중이다. 자율운항선박의 원활한 운용을 위해서는 정확한 위치, 항법, 시각 정보가 필수적이다. 현재 해양에서 사용되는 대표적인 항법시스템은 GPS(Global Positioning System)이지만 전파교란, 해킹 등의 취약성이 존재한다. 현재 GPS의 취약점을 보완하기 위한 다양한 항법시스템이 연구되고 있으며, 그 중 다양한 지상파 신호를 동시에 활용하는 지상파 통합항법시스템 R-MODE(Ranging mode)가 있다. 본 논문은 지상파 통합항법시스템 R-Mode 기술 중 지상파 VDES 신호를 활용한 VDES R-Mode에 대한 연구현황 및 향후 계획에 대해 기술하였다.

  • PDF

The Study of Measuring Method for Signal Processing Delay to Dual Mode Signal Transmission for Satellite DMB System (위성 DMB Dual Mode 신호전송에 따른 신호변환 Delay 측정 방법에 관한 연구)

  • Lee Young-Su;Choi Gyeong-Ho;Lee Byung-Suk;Cho Sung-Min;Ihm Tae-Jong
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.31-34
    • /
    • 2004
  • 본 논문에서는 현재 위성 DMB 국내 표준으로 채택되어 있는 System E 방식의 Dual Mode 신호 전송에 따른 신호변환시 Time Delay측정 방법에 대해서 제안을 하였다. 제안된 방식의 경우 아날로그 방식이 아닌 디지털 방식으로 정확한 Time Delay 측정이 가능하다. 그리고 위성 DMB Gap Filler System의 입 출력 단자를 통하여 측정이 가능함으로 측정값에 대한 신뢰성 확보가 가능하며 자동측정 방식임으로 측정시 발생될 수 있는 Human Error를 최소화 할 수 있다는 장점을 가지고 있다.

  • PDF

Common-Mode Current Reduction with Synchronized PWM Strategy in Two-Inverter Air-Conditioning Systems

  • Baek, Youngjin;Park, Gwigeun;Park, Dongmin;Cha, Honnyong;Kim, Heung-Geun
    • Journal of Power Electronics
    • /
    • v.19 no.6
    • /
    • pp.1582-1590
    • /
    • 2019
  • A new method for reducing the common-mode current generated by the voltage variations in a two-inverter air conditioner system by applying a synchronized pulse-width modulation (PWM) strategy is proposed. The PWM signals of the master-mode inverter are generated based on the reference voltage, while those of the slave-mode inverter are output in the opposite direction when the master-mode inverter changes its switching state. However, the slave-mode control results in a mismatch between the reference voltage and the actual output voltage that is modified by synchronized control operation. The proposed method is capable of reducing and controlling this voltage error by performing signal selection in the vector space of the slave-mode inverter, which mitigates the distortion of the phase current. The efficacy of this method in reducing conducted emissions has been validated both theoretically and experimentally.