• Title/Summary/Keyword: R-jig

Search Result 41, Processing Time 0.026 seconds

Easy Reproducible Tie-over Dressing using Silastic$^{(R)}$ Drainage (실라스틱(Silastic$^{(R)}$) 배액관을 이용한 간편한 봉합고정 드레싱)

  • Kim, Peter Chan Woo;Park, Sang-Soon;Lee, Yong-Jig;Shim, Jeong-Su;Park, Dae-Hwan
    • Archives of Plastic Surgery
    • /
    • v.37 no.3
    • /
    • pp.313-316
    • /
    • 2010
  • Purpose: Tie-over dressing is widely used to secure skin grafting on face, body, or extremities. It can be a rather complicated task and is not easy to make compressive dressing again if performed in a conventional method. So, we hereby introduce an easy reproducible tie over dressing method. Methods: After completing the skin graft, Cut the silastic drainage longitudinally in half and spread to the grafted skin margin. Drainage is fixed by using the stapes or sutures. A fluffy gauze bolus dressing is placed over a furacin impregnated gauze and wrapped around. After suturing the distal margin of silastics with opposite side using the silk thread either 5 - 0 or 3 - 0, knot of suturing, which is pressed down against the dressing while the threads are tightened, is made into center of each sides. Results: It can make dressing again after observing the grafted skin, and it can also make pressure on the grafted area evenly until the grafted skin is taken. Conclusion: This dressing method makes the surgeons and patients comfortable. To surgeons, it provides more rapid and easier way to do dressing, and to patients, it eliminates pain caused by redressing.

Development of an ACL Anchor: Effects of the Design Parameters on the Performance of a New Anterior Cruciate Ligament Fixation Device

  • Kim, Jong-Dae;Oh, Chae-Youn;Kim, Cheol-Sang
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.2
    • /
    • pp.132-138
    • /
    • 2008
  • We investigated the biomechanical properties of a newly designed self-expansion type anterior cruciate ligament (ACL) anchor. The ACL anchor consists of the ring section giving the elastic force, the wedge for maintaining in contact with the femur tunnel wall and the link suspending hamstring graft or artificial ligament. The main design parameters that determine the performance of this device were the expansion angle (${\theta}$) and the thickness ($t_R$). The Ti6Al4V anchors were heated after inserting in a jig for 1 hour at $800^{\circ}C$ in a protective argon gas atmosphere and allowed to cool to room temperature in the furnace. In order to investigate the influence of the expansion angle and the thickness of the ring on the biomechanical properties of the anchor, the maximum pull-out load, stiffness and slippage of the ACL anchor were measured using the pull-out tester, and statistical analyses were also executed. The present results showed that the design parameters gave a significant effect on the performance of the self- expansion type of anchor. The pull-out load of the ACL anchors significantly increased as the thickness of the ring section was increased, having a similar trend for both expansion angles. The ACL anchor showed about 2.5 times higher values of the pull-out load than that of the minimum load (500N)required for the "accelerated rehabilitation". The optimum ${\theta}$ and $t_R$ values of this ACL anchor were suggested to have sufficient resistance against the pull-out force, high stiffness and relatively low slippage after ACL reconstruction.

A Study on Fault Classification of Machining Center using Acceleration Data Based on 1D CNN Algorithm (1D CNN 알고리즘 기반의 가속도 데이터를 이용한 머시닝 센터의 고장 분류 기법 연구)

  • Kim, Ji-Wook;Jang, Jin-Seok;Yang, Min-Seok;Kang, Ji-Heon;Kim, Kun-Woo;Cho, Young-Jae;Lee, Jae-Wook
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.9
    • /
    • pp.29-35
    • /
    • 2019
  • The structure of the machinery industry due to the 4th industrial revolution is changing from precision and durability to intelligent and smart machinery through sensing and interconnection(IoT). There is a growing need for research on prognostics and health management(PHM) that can prevent abnormalities in processing machines and accurately predict and diagnose conditions. PHM is a technology that monitors the condition of a mechanical system, diagnoses signs of failure, and predicts the remaining life of the object. In this study, the vibration generated during machining is measured and a classification algorithm for normal and fault signals is developed. Arbitrary fault signal is collected by changing the conditions of un stable supply cutting oil and fixing jig. The signal processing is performed to apply the measured signal to the learning model. The sampling rate is changed for high speed operation and performed machine learning using raw signal without FFT. The fault classification algorithm for 1D convolution neural network composed of 2 convolution layers is developed.

Comparison of the replicability of centric relation registration techniques using Arcus Digma (Arcus Digma를 이용한 하악 중심위 유도방법에 따른 하악위의 재현성에 관한 비교 연구)

  • Lim, Hyun-Pil;Cho, Young-Eun;Park, Sang-Won
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.3
    • /
    • pp.201-210
    • /
    • 2009
  • The purpose of this study was to compare the replicability of centric relation made by means of self guided method, bimanual manipulation, chin-point guidance, leaf gauge method, gothic arch tracing. The EPA test of Arcus $Digma^{(R)}$ was employed for examining the reproducibility of centric relation. 10 adults with normal occlusion were participated in this study. In this limitation of study, the following results were obtained; Condyle position was different depending on different methods of guiding centric relation. Left and right temporomandibular joints showed a little different degree of repeatability. Bimanual manipulation using anterior jig was the most replicable. Chin point guidance provided the second most repeatable method, and Gothic arch tracing showed the third, the leaf gauge was the forth, the self-guided method was the worst.

Determination of Exposure Dose Rate and Isotropic Distributions of Substitute High Dose Rate Ir-192 Source for Co-60 Brachytherapy Source (원격강내조사용 Co-60 선원의 대체용 Ir-192 선원의 조사선량결정 및 선량 등방성조사)

  • 최태진;원철호;김옥배;김시운;김금배;조운갑;한현수;박경배
    • Progress in Medical Physics
    • /
    • v.9 no.1
    • /
    • pp.55-64
    • /
    • 1998
  • In recent, the demand of development of the high dose rate brachytherapy source increased for substitute for Co-60 source by iridium source, since the supplying Co-60 source is very depressed and the high dose rate brachytherapy sources are entirely imported from the abroad. This study investigated the exposure rates and isotropic dose distributions for the Ir-192 source produced from $\^$191/Ir(n,r)$\^$192/Ir by nuclear reactor in Korea Atomic Energy Research Institute. The activity of source was obtained an 1.012 Ci (the initial activity without encapsulation was 2,87Ci) by measurement with encapsuled stainless steel. The exposure rate of provided Ir-192 source was determined on 6.36 ${\pm}$ 0.147 Rm$^2$/h-GBq (2.350 ${\pm}$ 0.054 Rcm$^2$/mCi-hr) within ${\pm}$ 2.2% discrepancy with IC-10 ion chamber (0.14 cc) which was mounted on the acrylic jig to 5, 10 and 20 cm from the center of source. The calculated doses with 22 most significant spectrum lines were corrected with intrinsic efficiency of the germanium detector were compared to measured exposure dose rates within ${\pm}$3.8 % discrepancy. The authors confirmed the high dose rate Ir-192 source could be replaced the long decayed Co-60 source via investigation of the isotropic dose distributions in lateral, source axis and diagonal direction of source center are very closed to within 3% uncertainties. Especially, this exposure rate constant and isotropic dose distribution will be fundamental to build the high dose rate source and develop the computed therapy planning system.

  • PDF

Assessment of hazardous substances and workenvironment for cleanrooms of microelectronic industry (전자산업 청정실의 작업환경 및 유해물질농도 평가)

  • Chung, Eun-Kyo;Park, Hyun-Hee;Shin, Jung-Ah;Jang, Jae-Kil
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.19 no.3
    • /
    • pp.280-287
    • /
    • 2009
  • High-tech microelectronics industry is known as one of the most chemical-intensive industries. In Korea, Microelectronics industry occupied 38% of export and 16% of working employees work in microelectronics industry. But, chemical information and health hazards of high-tech microelectronics manufacturing are poorly understood because of rapid development and its penchant for secrecy. We need to investigate on chemical use and exposure control. We Site-visits to 6 high-tech microelectronics manufacturing company which have cleanroom work using over 1,000kg organic solvents (5 semi-conductor chips and its related parts company, 1 liquid crystal display (LCD)). We reviewed their data on chemical use and ventilation system, and measured TVOCs (Total Volatile Organic Compounds) and carbon dioxide concentration. All cleanroom air passed through hepa filters to acheive low particle levels and only 1 cleanroom uses carbon filters to minimize the organic solvents exposures In TVOC screening test, Cleanroom for semi-conductor chips and its related parts company with laminar down flow system (e.g. class 1~100) showed nondetectable level of TVOCs concentration, but Cleanroom for liquid crystal display (LCD) with conventional flow system (e.g. class 1,000~10,000) showed 327 ppm as TVOCs. Acetone concentration in cleanroom for Jig cleaning, LC Injection, Sealing processes were 18.488ppm (n=14), 49.762 ppm (n=15), 8.656 ppm (n=14) as arithmetric mean. Acetone concentration in cleanroom for LCD inspection process was 40ppm (n=55) as geometric mean, where the range was 7.8~128.7ppm and weakly correlated with ventilation rate efficiency(r=0.44, p<0.05). To control organic solvents in cleanrooms, chemical and carbon filters should be installed with hepa filters. Even though their volatile organic compounds concentration was not exceed to occupational exposure limits, considering of entrance limited cleanroom environment, long-term period exposure effects and adverse health effects of cleanroom worker need further reseach.

BLAC speed contol using precision Velocity Estimation through the Rotor Position ObservationR (관측 위치를 지령치로 하는 새로운 속도추정 알고리즘을 이용한 BLAC 속도제어)

  • Lee, Sang-Hun;Song, Hyin-Jig;Park, Chan-Kyu
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.17 no.3
    • /
    • pp.93-102
    • /
    • 2014
  • Recently the interest in permanent magnet alternating motor using for electric compressor become great. Especially the research on Interior Permanent Magnet Motor has been doing actively for its advantages in the energy density and the efficiency. In order to control the output of motor to the desired value, the current control or speed control of motor are required. The accurate detection of rotor position and speed information are necessary for the control of motor. In general, the encoder, hall sensor, and resolver are used to obtain the information of motor position and speed and the speed detection algorithm, M/T method, is applied. However, the M/T method causes the error depending on rotor speed. Therefore, this M/T speed detection method is not perfect. In this paper, it is proposed that the PI control with a 1st transfer function and the integration element between velocity and position are composed in series and this feeds back to the reference value of position angle. The proposed algorithm is a function of the integral elements 2nd term, speed element, is used as an output. Thus, it is possible to detect the correct speed by configuring like the mechanical structure similarly. The proposed algorithm is verified by using PSIM DLL and is applied to the BLAC motor drive. And also it is confirmed that this system estimates the accurate speed regardless of rotor speed changes. As a example, the experimental results and simulations shows that the proposed method is very effective.

Fatigue fracture of different dental implant system under cyclic loading (반복하중에 따른 수종 임플란트의 피로파절에 관한 연구)

  • Park, Won-Ju;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.4
    • /
    • pp.424-434
    • /
    • 2009
  • Statement of problem: Problems such as loosening and fractures of retained screws and fracture of implant fixture have been frequently reported in implant prosthesis. Purpose: Implant has weak mechanical properties against lateral loading compared to vertical occlusal loading, and therefore, stress analysis of implant fixture depending on its material and geometric features is needed. Material and methods: Total 28 of external hexed implants were divided into 7 of 4 groups; Group A (3i, FULL $OSSEOTITE^{(R)}$Implant), Group B (Nobelbiocare, $Br{\aa}nemark$ $System^{(R)}$Mk III Groovy RP), Group C (Neobiotec, $SinusQuick^{TM}$ EB), Group D (Osstem, US-II). The type III gold alloy prostheses were fabricated using adequate UCLA gold abutments. Fixture, abutment screw, and abutment were connected and cross-sectioned vertically. Hardness test was conducted using MXT-$\alpha$. For fatigue fracture test, with MTS 810, the specimens were loaded to the extent of 60-600 N until fracture occurred. The fracture pattern of abutment screw and fixture was observed under scanning electron microscope. A comparative study of stress distribution and fracture area of abutment screw and fixture was carried out through finite element analysis Results: 1. In Vicker's hardness test of abutment screw, the highest value was measured in group A and lowest value was measured in group D. 2. In all implant groups, implant fixture fractures occurred mainly at the 3-4th fixture thread valley where tensile stress was concentrated. When the fatigue life was compared, significant difference was found between the group A, B, C and D (P<.05). 3. The fracture patterns of group B and group D showed complex failure type, a fracture behavior including transverse and longitudinal failure patterns in both fixture and abutment screw. In Group A and C, however, the transverse failure of fixture was only observed. 4. The finite element analysis infers that a fatigue crack started at the fixture surface. Conclusion: The maximum tensile stress was found in the implant fixture at the level of cortical bone. The fatigue fracture occurred when the dead space of implant fixture coincides with jig surface where the maximum tensile stress was generated. To increase implant durability, prevention of surrounding bone resorption is important. However, if the bone resorption progresses to the level of dead space, the frequency of implant fracture would increase. Thus, proper management is needed.

Microbial Desulfurization of a Bituminous Coal by Iron-Oxidizing Bacteria Thiobacillus ferooxidans (철산화 박테리아 Thiobacillus ferrooxidans에 의한 역청탄의 생물학적 탈황)

  • 류희욱
    • KSBB Journal
    • /
    • v.11 no.2
    • /
    • pp.238-245
    • /
    • 1996
  • Microbial desulfurization characterlstics of a bituminous coal have been determined by using Thiobacillus ferrooxidans. The effects of process variables (such as coal pulp density, particle size and addition of surfactants) on pyrite removal have been investigated in both shake and airlift-bioreactor culture experiments. In shake experiments, pyrite could be removed over 78% for pulp densifies below 20% (w/v) and removed below 40% for pulp densities over 30% (w/v) in 8 days. Pyrite removal decreased with increasing pulp densities, and it also decreased sharply with increasing particle sizes. In airlift bioreactor experiments, pyrite at 50% (w/v) pulp density could be removed about 50%. Its value is much higher than 15% at the same pulp density in a shake experiment. With addition of surfactants, pyrite removal was enhanced in shake experiments significantly, whereas it was slightly decreased in an airlift bioreactor experiment.

  • PDF

Wound Healing Effect of Bacterial Synthesized Cellulose on Full Thickness Skin Defect in the Rat (박테리아 유래 셀룰로오스가 백서의 창상치유에 미치는 영향)

  • Park, Sang-Uk;Lee, Byung-Kwon;Kim, Mi-Sun;Park, Kwan-Kyu;Sung, Woo-Jung;Kim, Hyun-Yeon;Kim, Peter Chan-Woo;Shim, Jeong-Su;Lee, Yong-Jig;Kim, Seong-Ho;Kim, In-Ho;Park, Dae-Hwan
    • Archives of Plastic Surgery
    • /
    • v.38 no.6
    • /
    • pp.733-739
    • /
    • 2011
  • Purpose: Cellulose is a natural substance from plants or bacteria. It is known that bacterial synthesized cellulose has an effect of wound healing. The aim of this study is to show the effect of bacterial synthesized cellulose from citrus on wound healing. Methods: Three full-thickness skin defects were made on the back of Sprague-Dawley rats. Three wounds were treated by vaseline gauze (Group V), Algisite $M^{(R)}$ (Group A) and bacterial synthesized cellulose from citrus (Group C) was used for dressing on skin defect on rats. We analyzed the gross, histological and biochemistry finding. Results: Group C showed more decrease of wound size compared to Group V (33% versus 7.2%) after 14 days. The histologic findings revealed Group C and Group A preceed the process of wound healing rather than Group V (More rapid collagen deposition and neovascularization and reduced inflammation). Also, the expressions of vascular endothelial growth factor (VEGF) and transforming growth factor (TGF)-${\beta}1$ were increased in the Group C and Group A compared with the Group V in 7 days. VEGF and TGF-${\beta}1$ expression were decreased in the Group C and Group A in 14 days, however Group V was not decreased at 14 day because of delayed wound healing process. Conclusion: Bacterial synthesized cellulose from citrus affects wound healing by reducing the inflammatory stage. And stimulates wound contracture by the deposition of extracellular matrix, thus preventing the formation of chronic wounds.