• Title/Summary/Keyword: R-Mode

Search Result 1,578, Processing Time 0.038 seconds

Evaluation of Radiation Doses of Dental Portable Equipment (치과용 이동형 방사선장치의 선량평가)

  • Park, Hoon-Hee;Kang, Byung-Sam
    • Journal of radiological science and technology
    • /
    • v.41 no.5
    • /
    • pp.445-450
    • /
    • 2018
  • We aim to evaluate safety of radiation by measuring leakage dose and patient(phantom) incident dose of ZEN-PX II dental portable equipment developed by G company. Measurement for leakage dose of equipment is conducted on the top, at the bottom, on the left, on the right and at the back. Dose measurement incident on the subject with the area dosimeter when using the phantom and measurement the leakage dose of equipment when using the phantom are evaluated. Comparing the right with the highest leakage dose as a 0 cm, 25 cm, 50 cm, 75 cm and 100 cm dose measurement at the measurement height of 100 cm, 64.2 uR was reduced to 47.3 uR in the senser mode 0.32sec. Even in film mode it was measured at 414.4 uR and about 27% lower at 162.6 uR. As the result of this study, when the irradiation time is 2 sec the right side dose is 290.5 uR and sensor mode is 0.32 sec the right side dose is 64.2 uR.

Viewing angle improvement of TN mode by HD layer inside LC cell and a compensation film

  • Hong, Hyung-Ki;Lee, Jong-Hwae;Yoon, Sung-Whe
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.311-314
    • /
    • 2003
  • Holographic diffuser(HD) layer was demonstrated to be located inside LC cell for a transmissive LCD of TFT-array on Color Filter structure. Master pattern of this layer was generated by holographic method and this pattern was replicated by the stamping of the master pattern on UV resin. Combined with a compensation film, TN-mode LCD with this layer showed improved viewing angle characteristics, especially along the up-down direction.

  • PDF

Measurement of Subcutaneous Fat Thickness of the Korean by A-Mode Type Ultrasonic Instrument (A-mode 식 초음파기를 이용한 한국인의 피하지방 측정)

  • Hwang, Eun-Hee
    • Journal of Nutrition and Health
    • /
    • v.24 no.4
    • /
    • pp.308-313
    • /
    • 1991
  • This study attempted to measure subcutaneous fat thickness by the use of ultrasonic wave in age and sex matched Korean subjects, and to observe correlation between fat thick-ness and physical indices. In male, fat thickness of suprailiac area showed the highest value of $9.40{\sim}9.51mm$ and then subscapular was $6.60{\sim}6.84mm$, femoral was $6.48{\sim}7.04mm$ and triceps regions was $3.48{\sim}3.69mm$. In female, femoral subcutaneous fat thickness was the higher. $11.85{\sim}12.15mm$and then suprailiac was $8.79{\sim}9.87mm$ subscapular was $6.20{\sim}6.91mm$ and triceps fat thickness was $4.80{\sim}4.93mm$. In male, fat thickness of triceps and relative body weight(RBW). body mass index(BMI), triceps or $R\ddot{o}hrer$ index were positively correlated. Correlations between suprailiac and weight, relative body weight(RBW). body mass index(BMT), $R\ddot{o}hrer$ index or subscapular were positively significant. In female. there were positive correlations between fat thickness of femoral and RBW, BMI, or $R\ddot{o}hrer$ index. And there were no positive correlations in other parts of the body.

  • PDF

The Analysis of Yellowish Gravity-Mura in FFS Mode

  • Park, J.B.;Park, E.J.;Park, S.H.;Park, I.C.;Kim, H.Y.;Lee, K.H.;Lee, J.Y.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.780-783
    • /
    • 2006
  • In this paper, we confirmed the yellowish gravity-mura phenomenon in Fringe-Field Switching (FFS) mode using 2-D simulation. As the cell gap increases, while the LC efficiency of blue wavelength remains almost same, that of red and green wavelength increases continuously. As a result, yellowish phenomenon occurs.

  • PDF

Ductile Fracture Behaviour of SPS Specimen Under Pure Mode II Loading (순수 모드 II하중 하에서의 SPS 시험편의 연성파괴 특성에 관한 연구)

  • O, Dong-Jun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.2
    • /
    • pp.289-295
    • /
    • 2001
  • The aim of this study is to investigate the ductile fracture behaviour under pure Mode II loading using A533B pressure vessel steel. Single punch shear(SPS) test was performed to obtain the J-R curve under pure Mode II loading which was compared with that of the Model I loading. Simulation using Rousellier Ductile Damage Theory(RDDT) was carried out with 4-node quadrilateral element(L(sub)c=0.25mm). For the crack advance, the failed element removal technique was adopted with a $\beta$ criterion. Through the $\beta$ value tuning-up procedures, $\beta$(sub)crit(sup)II was determined as 1.5 in contrast with $\beta$(sub)crit(sup)I=5.5. In conclusion, it was found that the J-R curve under Mode II loading was located at lower part than that under Mode I loading obtained from the previous study and that the $\beta$ values strongly depended on the loading type. In addition, the predicted result using RDDT showed a good agreement with the SPS experimental one under pure Mode II loading.

Magnetic Properties of SmCo Thin Films Grown by Using a Nd-YAG Pulsed Laser Ablation Method (Nd-YAG Pulsed Laser Ablation법으로 제작한 SmCo계 박막의 자기특성)

  • 김상원;양충진
    • Journal of the Korean Magnetics Society
    • /
    • v.10 no.1
    • /
    • pp.30-36
    • /
    • 2000
  • SmCo films were deposited on Si(100) substrate by a Nd-YAG pulsed laser ablation of the targets of Sm$\_$100-x/Co$\_$x/ (73$\leq$x$\leq$93) at the substrate temperature of 600∼700$\^{C}$ and the laser beam energy density of Q switching mode or fixed Q mode. The magnetic properties of the films obtained from the Q switching mode exhibited a 4 $\pi$ Ms of 5200∼7700 Gauss, iHc of 190-250 Oe, and 4$\pi$M$\_$r//4$\pi$M$\_$s/ of 0.4∼0.74, respectively, while the fixed Q mode gave the magnetic properties of corresponding films of a 4$\pi$M$\_$r//4$\pi$M$\_$s/ = 0.32∼0.91 and iHc of 430-6290 Oe, respectively. The fixed Q mode gave the better magnetic properties of the SmCo films which seems to be due to a formation of magnetically hard minor phases in droplet of Sm-rich intermetallics. However, the resultant rough surface of the SmCo films is a problem to be solved by a continued study.

  • PDF

Compact Triple-Mode Bandpass Filter Using a Cylindrical Dielectric Resonator (원통형 삼중모드 유전체 공진기를 이용한 대역 통과 여파기의 설계)

  • Jang, Geon-Ho;Park, Nam-Shin;Kim, Byung-Chul;Lee, Don-Yong;Won, Jung-Hee;Wang, Xu-Guang
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.1
    • /
    • pp.30-38
    • /
    • 2015
  • In this paper, the design of a compact triple-mode bandpass filter using a high-Q cylindrical dielectric resonator is proposed. In detail, the triple $TE_{01{\delta}}$ modes along three orthogonal axes are used and novel coupling structure in the metallic enclosure is adopted to introduce the coupling between the resonant modes. Due to the cross coupling, the proposed bandpass filter has an asymmetric frequency response with flexible three transmission zeros, one of which can be located very close to the passband edge to provide an extremely sharp skirt characteristic with low insertion loss. The proposed filter is about 60 % miniaturized compared with conventional single-mode dielectric resonator filter. The proposed bandpass filter design is validated by the circuit and 3D EM simulations and measurements compared to the target specifications.

Sensorless speed control of Permanent Magnet Synchronous Motor by an Improved Sliding Mode Observer (개선된 슬라이딩 모드 관측기에 의한 영구자석 동기전동기의 센서리스 제어)

  • Ryu Sung-Lay;Kim Ji-Hyun;Lee In-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.485-487
    • /
    • 2006
  • Speed and torque controls of permanent magnet synchronous motors are usually attained by the application of position and speed sensors. However, speed and position sensors require the additional mounting space, reduce the reliability in harsh environments and increase the cost of a motor. Therefore, many studies have been performed for the elimination of speed and position sensors. This paper investigates an Improved sliding mode observer for the speed sensorless control of a permanent magnet synchronous motor. The proposed control strategy is the sliding mode observer with a variable boundary layer for a low-chattering and fast-reponse control. The proposed algorithm is verified through the simulation and experimentation.

  • PDF

Design of a Wide-Viewing-Angle OCB Mode with Wide-Band Wide-Viewing-Angle Quarter-Wave Plates

  • Lee, Seong-Ryong;Jhun, Chul-Gyu;Yoon, Tae-Hoon;Kim, Jae-Chang;Noh, Jeong-Dong;Suh, Dong-Hae;Lee, Jung-Yeal
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.345-348
    • /
    • 2005
  • In this paper we propose a configuration for an optically compensated bend (OCB) mode using circular polarizers with wide-band wide-viewing-angle (WBWA) quarter-wave plates (QWPs). Parameters of LC material and compensation films are optimized for wide viewing angle characteristics and excellent spectral properties of the OCB mode.

  • PDF

a-Si TFT Integrated Gate Driver Using Multi-thread Driving

  • Jang, Yong-Ho;Yoon, Soo-Young;Park, Kwon-Shik;Kim, Hae-Yeol;Kim, Binn;Chun, Min-Doo;Cho, Hyung-Nyuck;Choi, Seung-Chan;Moon, Tae-Woong;Ryoo, Chang-Il;Cho, Nam-Wook;Jo, Sung-Hak;Kim, Chang-Dong;Chung, In-Jae
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.1251-1254
    • /
    • 2006
  • A novel a-Si TFT integrated gate driver circuit using multi-thread driving has been developed. The circuit consists of two independent shift registers alternating between the two mode, "wake" and "sleep". The degradation of the circuit is retarded since the bias stress is removed during the sleep mode. It has been successfully integrated in 14.1-in. XGA LCD Panel, showing enhanced stability.

  • PDF