• 제목/요약/키워드: R-C compensation

검색결과 73건 처리시간 0.029초

퍼지제어기를 이용한 초음파 모터의 온도특성에 관한 연구-주파수 제어 (A study on the characteristic or temperature for Ultrasonic Motor using Fuzzy Controller - with frequency control)

  • 서기열;차인수;박해암;최장균
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.597-599
    • /
    • 1996
  • This paper describes the bending traveling-wave type ultrasonic motor which generates the traveling wave by combining two standing waves with phase difference time and space. In $+20^{\circ}C{\sim}30^{\circ}C$, the USM motor operation character has represented normal condition. But the other temperature, (that is say, when long time operating condition) USM operation characteristic has abnormal condition, that is driving frequency, drive current and r.p.m is down. The recent USM has controller without temperature compensation. This study aimed at fuzzy controller which must follow the frequency at operation temperature and then r.p.m and torque increase.

  • PDF

퍼지제어기를 이용한 초음파 모터의 온도특성에 관한 연구 - 위상차 제어 (A Study on the characteristic of temperature for Ultrasonic Motor using Fuzzy Controller - with phase angle difference control)

  • 서기열;차인수;윤형상;유권종
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1996년도 창립기념 전력전자학술발표회 논문집
    • /
    • pp.52-55
    • /
    • 1996
  • This paper describes the bending traveling-wave type ultrasonic motor which generates the traveling wave by combining two standing waves with phase difference time and space. In $+20^{\circ}C$~$30^{\circ}C$, the USM motor operation character has represented normal condition. But the other temperature, (that is say, when long time operating condition) USM operation characteristic has abnormal condition, that is driving frequency, drive current and r.p.m is down. The recent USM has controller without temperature compensation. This study aimed at fuzzy controller which must follow the phase angle difference 90$^{\circ}$at operation temperature and them r.p.m and torque increase.

  • PDF

SSSC로 보상된 송전 선로의 거리계전 알고리즘에 관한 연구 (A Study on a Distance Relaying Algorithm for Transmission Line Compensated with SSSC)

  • 양진우;남순열;손진만;박종근;강용철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1401-1403
    • /
    • 1999
  • This paper presents a distance relaying algorithm for transmission line compensated with Static Synchronous Series Compensator (SSSC). The compensation voltage driven by SSSC is calculated from the line current measured at a relaying point Then the compensation voltage is subtracted from the voltage measured by the relay. We can apply conventional distance relaying algorithm with this subtracted voltage to locate a fault. The results of case studies using EMTP (Electro-Magnetic Transient Program) show the proposed algorithm has higher precision.

  • PDF

Cell Signal Distribution Characteristics For High Density FeRAM

  • Kang, Hee-Bok;Park, Young-Jin;Lee, Jae-Jin;Ahn, Jin-Hong;Sung, Man-Young;Sung, Young-Kwon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제4권3호
    • /
    • pp.222-227
    • /
    • 2004
  • The sub-bitline (SBL) sensing voltage of a cell and total cell array can be measured by the method of SBL voltage evaluation method. The MOSAID tester can collect all SBL signals. The hierarchical bitline of unit cell array block is composed of the cell array of 2k rows and 128 columns, which is divided into 32 cell array sections. The unit cell array section is composed of the cell array of 64 rows and 128 columns. The average sensing voltage with 2Pr value of $5{\mu}C/cm^2$ and SBL capacitance of 40fF is about 700mV at 3.0V operation voltage. That is high compensation method for capacitor size degradation effect. Thus allowed minimum 2Pr value for high density Ferroelectric RAM (FeRAM) can move down to about less than $5{\mu}C/cm^2$.

내장형 capacitor를 위한 LCP와 $BaTiO_3-SrTiO_3$ 복합재의 유전특성 (Dielectric Properties of LCP and $BaTiO_3-SrTiO_3$ Composites for Embedded Matching Capacitors)

  • 김진철;윤상준;윤금희;오준록
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.60-60
    • /
    • 2008
  • We manufactured Liquid Crystal Polymer (LCP) and (1-x)$BaTiO_3-xSrTiO_3$(BST) ceramic composites and investigated dielectric properties to use as embedded capacitor in printed circuit boards and replace LTCC substrates. The dielectric properties of these composites are varied with volume fraction of BST and ratios of BT/ST. Dielectric constants are in the range of 3~28. In addition, we could get low TCC and High Q value that could not achieve in other ceramic-polymer composites. Especially, in composite with x=0.4 and 50vol% BST, the dieletric constant and Q-value are 27 and 300, respectively. And more TCC is -116~145ppm/$^{\circ}C$ in the temperature range of -55~$125^{\circ}C$. We think that this composites can be used high-Q substrate material like LTCC and embedded temperature compensation capacitor in printed circuit boards.

  • PDF

사용자와의 협력 플레이를 위한 강화학습 인공지능 프로세스 구축 (Build reinforcement learning AI process for cooperative play with users)

  • 정원조
    • 한국게임학회 논문지
    • /
    • 제20권1호
    • /
    • pp.57-66
    • /
    • 2020
  • 연구는 MOBA 게임에서 선호도가 낮은 Supporter를 대체하는 인공지능을 강화학습을 이용한 구현을 목표하였다. ML_Agent를 이용해 게임의 규칙, 환경, 관측 정보, 보상 처벌을 구성하였다. DPS 에이전트로 구성된 그룹과, Support 에이전트가 있는 그룹으로 나누어 강화학습을 진행하였다. 결과 데이터인 누적 보상 값, 사망 횟수 바탕으로 결론을 도출하였다. 협력 플레이 그룹이 비교 그룹보다 평균 누적 보상 값이 3.3 더 높게 측정되었으며 사망 횟수 총합 평균은 3.15 낮게 되었다. 이를 바탕으로 죽음을 최소화하고 보상을 최대화하는 협력 플레이를 수행하는 강화학습을 확인할 수 있었다.

교류 철도 차량 시스템용 단상 PWM Converter 개발 (Development of Single Phase PWM Converter for AC Traction System)

  • 민성식;차재덕;홍순욱;김송웅;박영춘;김중한
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.505-508
    • /
    • 1994
  • This paper describes an implementation of a single phase PWM ac/dc converter whose control scheme can be directly applied to the rectification of ac traction system. Power circuit using self-commutated switching devices(GTO) provides input power factor correction with dc voltage regulation. Effective compensation of load variations and line disturbance can be accomplished by real time instantaneous control of ac input current and dc link voltage using 32 bit floating point DSP. Parallel operation of two converters reduces the input line current ripple. Experimental results of the two parallel converter system are shown in the 20KW range for the verification of the system.

  • PDF

근적외선을 이용한 신고 배 당도판정에 있어 표면 온도영향의 보정 (Compensation of Surface Temperature Effect in Determination of Sugar Content of Shingo Pears using NIR)

  • 이강진;최규홍;김기영;최동수
    • Journal of Biosystems Engineering
    • /
    • 제27권2호
    • /
    • pp.117-124
    • /
    • 2002
  • This research was conducted to develop a method to remove the effect of surface temperature of Shingo pears for sugar content measurement. Sugar content was measured by a near-infrared spectrum analysis technique. Reflected spectrum and sugar content of a pear were used for developing regression models. For the model development, reflected spectrums having wavelengths in the range of 654 to 1,052nm were used. To remove the effect of surface temperature, special sample preparation techniques and partial least square (PLS) regression models were proposed and tested. 71 Shingo pears stored in a cold storage, which had 2$^{\circ}C$ inside temperature, were taken out and left in a room temperature for a while. Temperature and reflected spectrum of each pear was measured. To increase the temperature distribution of samples, temperature and reflected spectrum of each pear was measured four times with one hour twenty minutes interval. During the experiment, temperature of pears increased up to 17 $^{\circ}C$. The total number of measured spectrum was 284. Three groups of spectrum data were formed according to temperature distribution. First group had surface temperature of 14$^{\circ}C$ and total number of 51. Second group consisted of the first and the fourth experiment data which contained the minimum and the maximum temperatures. Third group consisted of 155 data with normal temperature-distribution. The rest data set were used for model evaluation. Results shelved that PLS model I, which was developed by using the first data group, was inadequate for measuring sugar content of pears which had different surface temperatures from 14$^{\circ}C$. After temperature compensation, sugar content predictions became close to the measured values. Since using many data which had wide range of surface temperatures, PLS model II and III were able to predict sugar content of pears without additional temperature compensation. PLS model IV, which included the surface temperatures as an independent variable. showed slightly improved performance(R$^2$=0.73). Performance of the model could be enhanced by using samples with more wide range of temperatures and sugar contents.

상대습도계의 온도 의존성과 경년변화의 통계적 분석 (Statistical Analysis on the Temperature Dependence and Long-Term Change of Relative Humidity Sensors)

  • 김종철;최병일;우상봉;양인석
    • 센서학회지
    • /
    • 제21권6호
    • /
    • pp.420-424
    • /
    • 2012
  • We have investigated temperature dependence and long-term change of humidity measurement from 32 relative humidity sensors. The readings of the humidity sensors depended not only the reference humidity, but also temperature of the chamber. Approximately, the temperature dependence of the humidity sensor in average was 0.05 %R.H./$^{\circ}C$ in the temperature range from $5^{\circ}C$ to $55^{\circ}C$. For humidity sensors that have an internal temperature compensation circuit, the resulting temperature dependence was weaker by 20%. It should be also noted that for the humidity sensors used in this work underwent ${\pm}3$ %R.H. change per year for level of confidence of 95%. The users of relative humidity sensors may refer this value as a minimum change when they set the calibration interval of the humidity sensors.

목본식물 형성층 전기저항에 영향을 주는 환경 요인 (Effects of Environmental Factors on the Cambial Electrical Resistance of Woody Plants)

  • 김동욱;김민수;이부용
    • 한국조경학회지
    • /
    • 제35권3호
    • /
    • pp.105-113
    • /
    • 2007
  • This study was conducted to analyze the effects of environmental factors such as soil moisture, light intensity, temperature and humidity on changes in cambial electrical resistance. To improve data quality, cambial electrical resistance was continuously measured at fixed points by using a data logger isolated from alternating current. The relationship between environmental factors and changes in cambial electrical resistance was also analyzed. The results are as follows: 1. Cambial electrical resistance is highly correlated to the temperature of the measured area(r=-0.934). Therefore, temperature compensation is needed to analyze the effects of other environmental factors on cambial electrical resistance changes. 2. If temperature is compensated for, the change of cambial electrical resistance is highly correlated to water vapor pressure(r=-0.836). 3. If temperature and humidity are compensated for, the change of cambial electrical resistance is highly correlated to intensity of light(r=-0.738). 4. Diurnal deviation of soil water potential is not more significantly related than the change of cambial electrical resistance. However, in the long-term, soil water potential and cambial electrical resistance are highly correlated(r=-0.831). This indicates that soil moisture significantly influences the long-term change of cambial electrical resistance.