• Title/Summary/Keyword: R-C circuit

Search Result 288, Processing Time 0.033 seconds

Electrochemical Behavior of AZ31 Mg Alloy in Neutral Aqueous Solutions Containing Various Anions

  • Duyoung Kwon;Hien Van Pham;Pungkeun Song;Sungmo Moon
    • Journal of Electrochemical Science and Technology
    • /
    • v.14 no.4
    • /
    • pp.311-319
    • /
    • 2023
  • This work was performed to characterize the electrochemical behavior of AZ31 Mg alloy in neutral aqueous solutions where Cl-, SO42-, PO43-, and F- ions were present and pH was adjusted to 6 to exclude the contribution of H+ and OH- ions. Open-circuit potential (OCP) transient, electrochemical impedance spectroscopy (EIS) and potnetiodynamic polarization curves were employed. The OCP value appeared to decrease in the order of F- > Cl- > SO42- > PO43- ions while corrosion current density increased in the same order. Electrochemical impedance spectroscopy (EIS) data showed two capacitive arcs in all the solutions and one more inductive arc appeared in PO43--containing solution. By fitting of two capacitive arcs, capacitance of dense film (Cdf), resistance of porous film (Rpf) and double layer capacitance (Cdl) and charge transfer resistance (Rct) beneath the porous films were obtained. A simplified model in which various thicknesses and coverages of dense and porous films are assumed to be present on the AZ31 Mg alloy surface, is suggested to explain the effects of four different anions on the electrochemical behavior of AZ31 Mg alloy.

Development of a New Refrigerant Mixture (RM-1) to improve the performance of Heat Pump System for Heating and Cooling of the Living Space (생활공간 냉난방용 열펌프의 성능개선을 위한 새로운 혼합냉매(RM-1) 개발)

  • Song, Heon;Ro, Jeong-Geun
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.5
    • /
    • pp.67-76
    • /
    • 2011
  • 생활공간 냉난방용 열펌프의 성능향상을 위해 R22의 대체 냉매로서 새로운 혼합냉매R22/R23/R152a(RM-1)을 개발하고 U. S. A.의 NIST사의 REFPRO Pprogram을 이용해 이 혼합냉매의 P-h diagram을 구성하여 실용화에 이용할 수 있도록 하였다. 본 연구는 실험을 통해 R22와 RM-1의 열펌프 성능효과를 분석하였다. 입 출구 물의 온도와 제2의 전열매체로서 물의 질량유량, 압축기의 소요 에너지 그리고 열펌프의 기타 열적 특성을 다양한 조건하에서 측정하였다. 이 실험 데이터를 통해 공기-물 열펌프 시스템에서의 RM-1과 R22의 성능계수(COP)를 비교하였다. 이를 통해, 혼합냉매 RM-1을 사용하는 열펌프 시스템은 외기온 $-17^{\circ}C$에서도 2.2의 성능계수로 작동하는 결과를 본 연구에서 보여주었다.

A Low-Power 2.4 GHz CMOS RF Front-End with Temperature Compensation

  • Kwon, Yong-Il;Jung, Sang-Woon;Lee, Hai-Young
    • Journal of electromagnetic engineering and science
    • /
    • v.7 no.3
    • /
    • pp.103-108
    • /
    • 2007
  • In this paper, a low-power 2.4 GHz front-end for sensor network application (IEEE 802.15.4 LR-WPAN) is designed in a 0.18 um CMOS process. A power supply circuit with a novel temperature-compensation scheme is presented. The simulation and measurement results show that the front-end (LNA, Mixer) can achieve a voltage gain of 35.3 dB and a noise figure(NF) of 3.1 dB while consuming 5.04 mW (LNA: 2.16 mW, Mixer: 2.88 mW) of power at $27^{\circ}C$. The NF includes the loss of BALUN and BPF. The low-IF architecture is used. The voltage gain, noise figure and third-order intercept point (IIP3) variations over -45$^{\circ}C$ to 85$^{\circ}C$ are less than 0.2 dB, 0.25 dB and 1.5 dB, respectively.

Printed Active-Matrix Displays

  • Burns, S.E.;Kuhn, C.;Jacobs, K.;Ramsdale, C.;Arias, A.C.;Watts, J.;Etchells, M.;Chalmers, K.;Devine, P.;Murton, N.;Norval, S.;King, J.;Mills, J.;Sirringhaus, H.;Friend, R.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.227-229
    • /
    • 2003
  • We present a process for printing active matrix displays. In this process, transistors are fabricated using soluble semi-conducting and conducting materials. Accurate definition of the transistor channel and other circuit components is achieved by direct inkjet printing combined with surface energy patterning. We present results on our 4,800 pixel, 50 dpi, active matrix displays.

  • PDF

Modeling and Simulation of the Cardiovascular System Using Baroreflex Control Model (압반사 제어모델을 이용한 심혈관 시스템의 모델링 및 시뮬레이션)

  • Choi, B.C.;Eom, S.H.;Nam, G.K.;Son, K.S.;Lee, Y.W.;Jun, K.R.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.165-170
    • /
    • 1997
  • In this paper, we consider the aortic sinus baroreceptor, which is the most representative baroreceptors sensing the variance of pressure in the cardiovascular system(CVS), and propose heart activity control model to observe the effect of delay time in heart period and stroke volume under the regulation of baroreflex in arotic sinus. The proposed heart activity baroreflex regulation model contains CVS electric circuit sub-model, baroreflex regulation sub-model and time delay sub-model. In these models, applied electric circuit sub-model is researched by B.C.Choi and the baroreflex regulation sub-model transforms the input, the arotic pressure of CVS electric circuit sub-model, to outputs, heart period and stroke volume by mathematical nonlinear feedback. We constituted the time delay sub-model to observe sensitivity of heart activity baroreflex regulation model by using the variable value to represent the control signal transmission time from the output of baroreflex regulation model to efferent nerve through central nervous system. The simulation object of this model is to observe variability of the CVS by variable value in time delay sub-model. As simulation results, we observe three patterns of CVS variability by the time delay. First, if the time delay is over 2.5 sec, arotic pressure, stroke volume and heart rate is observed nonperiodically and irregularly. Second, if the time delay is from between 0.1 sec and 0.25 sec, the regular oscillation is observed. Finally, if time delay is under 0.1 sec, then heart rate and arotic pressure-heart rate trajectory is maintained in stable state.

  • PDF

A Study of Over Voltage Ground Relay Operation Status at Opening of No-load Charged Cable (무부하 충전케이블 개방시 잔류전압에의한 과전압계전기 동작현상 연구)

  • Kim, Yeong-Han;Choi, Jong-Hyuck;Yoon, Ki-Seob
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.185-187
    • /
    • 2000
  • Fault current is flowed into 154/23kV M. Tr when line-to-ground fault occurs in power system. NGR(Neutral Grounded Reactor) is set up in order to prevent M.Tr fault by limiting magnitude of fault currents. Here, disconnection of NGR causes voltage increase by L-C resonance and line-to-ground fault in an unearthed system results in voltage increase at healthy phases. So Over Voltage Ground Relay(OVGR) is used for tripping M.Tr. Also, buses at second phases of M.Trs are all connected with section circuit breakers closed for the purpose of parallel operation and load shedding. In case of speciality buses are comprised of power cable in part for GIS connection. When no-load charged cable or bus is open by a section CB, unbalanced voltage charged on the bus is induced. Also discrepant opening time for circuit breakers on different phases gives rise to unbalanced zero sequence voltage. It was observed that this zero sequence voltage detected in the 22.9kV P.T (Potential Transformer for bus) mal-operated 59GT and tripped M.Tr. The zero sequence voltage of which vanishing time is longer than relay operating time came out by EMTDC simulation. Also, it was shown that the voltage waves of actual test are similar to those of simulation. On the basis of above results, R-C circuit complement on the relay without any effect on a power system made operating time of the relay longer than vanishing time of distorted waves. Consequently, operating time of the relay was delayed and magnitude of distorted waves was decreased by increasing time constant of the relay.

  • PDF

Interfacial Adhesion and Reliability between Epoxy Resin and Polyimide for Flexible Printed Circuit Board (연성인쇄회로기판의 에폭시수지와 폴리이미드 사이의 계면접착력 및 신뢰성 평가)

  • Kim, Jeong-Kyu;Son, Kirak;Park, Young-Bae
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.24 no.1
    • /
    • pp.75-81
    • /
    • 2017
  • The effects of KOH pretreatment and annealing conditions on the interfacial adhesion and the reliability between epoxy resin and polyimide substrate in the flexible printed circuit board were quantitatively evaluated using $180^{\circ}$ peel test. The initial peel strength of the polyimide without the KOH treatment was 29.4 g/mm and decreased to 10.5 g/mm after 100hrs at $85^{\circ}C/85%$ R.H. temperature/humidity treatment. In case of the polyimide with annealing after KOH treatment, initial peel strength was 29.6 g/mm and then maintained around 27.5 g/mm after $85^{\circ}C/85%$ R.H. temperature/humidity treatment. Systematic X-ray photoelectron spectroscopy analysis results showed that the peel strength after optimum annealing after KOH treatment was maintained high not only due to effective recovery of the polyimide damage by the polyimide surface treatment process, but also effective removal of metallic ions and impurities during various wet process.

Study on Circuit Analysis of FHF-32W Electronic Ballast (FHF-32W 전자식 안정기의 회로해석에 관한 연구)

  • Oh, C.R.;Baek, S.H.;Kim, Y.;Kim, I.N.;Jung, I.R.;Ryu, J.S.;Choi, B.I.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07f
    • /
    • pp.2168-2170
    • /
    • 1997
  • A paralled-loaded electronic ballast operating slighty above its resonant frequency is selected because of the high voltage gains. It is shown that the ballast can be designed to operate under Zero Voltage Switching(ZVS) conditions. Pspice simulation is useful in predicting the waveformes and rms of lamp voltage and current.

  • PDF

Interrupting Performance of 7.2kV $SF_6$ Gas Electromagnetic Contactor Using Rotary Arc Principle (7.2kV급 로타리아크 소호방식을 이용한 $SF_6$가스 전자접촉기의 차단특성)

  • Chang, K.C.;Chong, J.K.;Shin, Y.J.;Kim, J.K.;Kim, G.S.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.77-79
    • /
    • 1996
  • The model interrupters of $SF_6$ gas electromagnetic contactor whose ratings are 7.2kV, 4.0kA have been designed and manufactured on the basis of theoretical and computational analysis for its development. The eddy current analysis, the magnetic field analysis and the calculation of the rotational force on arcs have been conducted using FLUX2D package. The short circuit current interrupting tests have been conducted for the model interrupters using the simplified synthetic testing facility in KERI. The results show that the model interrupters have sufficient interrupting capability and the new design concept is prefer for good interrupting performance.

  • PDF

A Study on the Degradation Characteristics of ZnO Ceramic Devices by the Valence Controls (원자가 제어에 의한 ZnO 세라믹 소자의 열화특성 연구)

  • 소순진;김영진;소병문;박춘배
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.157-160
    • /
    • 2001
  • Three sets of ZnO ceramic devices (reference samples with Matsuoka\`s composition; added 7o MgO, A1$_2$O$_3$, SiO$_2$) have been prepared by the conventional mixed oxide route. These additives were determined by the factors of valences and ionic radiuses. DC accelerated degradation test was performed for analysis of degradation characteristics versus the various additives. The conditions of DC degradation test were 115${\pm}$2$^{\circ}C$ for 12h. Using XRD and SEM, the Phase and microstructure of samples were analyzed respectively. E-J analysis was used to determine ${\alpha}$. Frequency analysis was accomplished to understand the relationship between R$\sub$g/ and $R_{b}$ with the electric stress at the equivalent circuit.

  • PDF