• Title/Summary/Keyword: R-BENCH

Search Result 77, Processing Time 0.022 seconds

The Improvement of China's Nuclear Safety Supervision Technical Support Ability

  • Han Wu;Guoxin Yu;Xiangyang Zheng;Keyan Teng
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.20 no.4
    • /
    • pp.523-531
    • /
    • 2022
  • The International Atomic Energy Agency (IAEA) entails independent decision-making for the safety supervision of civil nuclear facilities. To evaluate and review the safety of nuclear facilities, the national regulatory body usually consults independent institutions or external committees. Technical Support Organizations (TSOs) include national laboratories, research institutions, and consulting organizations. Support from professional organizations in other countries may also be required occasionally. Most of the world's major nuclear power countries adopt an independent nuclear safety supervision model. Accordingly, China has continuously improved upon the construction of such a system by establishing the National Nuclear Safety Administration (NNSA) as the decision-making department for nuclear and radiation safety supervision, six regional safety supervision stations, the Nuclear and Radiation Safety Center (NSC), a nuclear safety expert committee, and the National Nuclear and Radiation Safety Supervision Technology R&D Base, which serves as the test, verification, and R&D platform for providing consultation and technical support. An R&D system, however, remains to be formed. Future endeavors must focus on improving the technical support capacity of these systems. As an enhancement from institutional independence to capability independence is necessary for ensuring the independence of China's nuclear safety regulatory institution, its regulatory capacity must be improved in the future.

A Hardware-Software Co-verification Methodology for cdma2000 1x Compliant Mobile Station Modem (cdma2000 1x 이동국 모뎀을 위한 하드웨어-소프트웨어 동시 검증 방법)

  • Han, Tae-Hee;Han, Sung-Chul;Han, Dong-Ku;Kim, Sung-Ryong;Han, Geum-Goo;Hwang, Suk-Min;Kim, Kyung-Ho
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.39 no.7
    • /
    • pp.46-56
    • /
    • 2002
  • In this paper, we describe a hardware-software co-verification methodology and environment in developing a mobile station modem chip for cdma2000 1x which is one of the 3rd generation mobile communication standards. By constructing an efficient co-verification environment for a register-transfer-level hardware model and a physical-layer software model combining a channel link simulator and a versatile test-bench, we can drastically reduce both time and cost for developing a complex three-million-gate class system integrated circuit.

Performance of HFC32/HFC152a Mixture for Water-source Heat Pumps (수열원 히트펌프 용 HFC32/HFC152a 혼합냉매의 성능평가)

  • Kang, Dong-Gyu;Kim, Wook-Jin;Jung, Dong-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.5
    • /
    • pp.391-400
    • /
    • 2012
  • In this study, performance of HFC32/HFC152a mixture is measured in the composition range of 20 to 50% R32 with an interval of 10% for the comparison with the conventional HCFC22 in water-source heat pumps. Tests are carried out under the same capacity in a heat pump bench tester equipped with a variable speed compressor at the evaporation and condensation temperatures of 7/$45^{\circ}C$ and -7/$41^{\circ}C$ for summer and winter conditions, respectively. Test results show that the compressor power of the HFC32/HFC152a mixture is 13.7% lower than that of HCFC22 while the coefficient of performance(COP) the HFC32/HFC152a mixture is 15.8% higher than that of HCFC22. Hence, from the view point of energy efficiency, the HFC32/HFC152a mixture is excellent as compared to HCFC22. Compressor discharge temperatures of HFC32/HFC152a mixture are increased up to $15.4^{\circ}C$ as compared to that of HCFC22. The amount of charge for HFC32/HFC152 mixture decrease up to 27% as compared to that of HCFC22. Overall, HFC32/ HFC152a mixture is an excellent long term candidate to replace HCFC22 in water-source heat pumps.

Effects of Aeration on Biological Activities During Composting of Dairy Manure in Enclosed BenchScale Reactor (밀폐형 Bench-scale reactor 에서의 우분 퇴비화시 Aeration 이 생물학적 활성에 미치는 영향)

  • Kang, Hang-Won;Zhang, R.H.;Park, Hyang-Mee;Ko, Jee-Yeon;Rhee, In-Koo;Park, Kyeong-Bae
    • Korean Journal of Environmental Agriculture
    • /
    • v.17 no.3
    • /
    • pp.260-267
    • /
    • 1998
  • This experiment used the enclosed bench-scale reactors of 242 liters was conducted to obtain basic data on temporal and spatial variations in temperature, oxygen and moisture content, which were important factors of biological activities, during composting of mixture of dairy manure and rice straw. The reactors with thermocouples, oxygen sensor and datalogger were aerated at four different rates of 0.09, 0.18, 0.90 and 1.79 l $min^{-1}kg$ dry $solids^{-1}$. The higher aeration rates were, the faster the rates of increase and decrease in composting temperature were in both of initial and turnover stage, and the smaller the temperature difference between exhaust air and composting materials. Composting temperature of initial stage increased suddenly in all aeration rates, then stationary phase of temperature in materials and exhaust air showed at $50{\sim}53^{\circ}C$ for 5 hours and at $45^{\circ}C$ between 5 and 15 hours, respectively. In initial stage the maximum temperature was decreased with increasing aeration rates but in the stage after turnover it was the opposite except for 1.79 l $min^{-1}kg^{-1}$. Time arrived at the maximum temperature of composting materials was later in low-aeration rates than high-aeration rates at both stages. Time maintained high-temperature more than $45^{\circ}C$ was rapidly decreased with increasing aeration rates. In initial stage of composting maintaining time of $65^{\circ}C$ or more was the longest in the treatments of 0.09 and 0.18 l $min^{-1}kg{-1}$, while those of $55{\sim}65^{\circ}C$ and $45{\sim}55^{\circ}C$ was in 0.90 and 1.79 l $min^{-1}kg{-1}$, respectively. The minimum oxygen content and the maximum oxygen consumption rate in exhaust air through composting materials showed the increased trends with increasing aeration rates. In initial stage the minimum oxygen content was ranged from 0.9% to 7.4% for 32 to 59.5 hours and the maximum oxygen consumption rate was $1.89{\sim}6.48$ $gh^{-1}kgVS^{-1}$. In the stage after turnover their levels were $2.1{\sim}19.9%$ and $1.76{\sim}3.49 %$g/h-㎏ VS, respectively, for 16 to 49.5 hours.

  • PDF

Analysis of Diesel Nano-particle Characteristics for Different Vehicle Test Mode in Diesel Passenger Vehicle (디젤 승용차량 시험모드별 극미세입자 배출 특성 해석)

  • Lee, Jin-Wook;Jung, Min-Won;Jeong, Young-Il;Cha, Kyong-Ok
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.1
    • /
    • pp.114-120
    • /
    • 2008
  • Recently, the nano-PM's number concentration emitted by diesel internal combustion engine has focused on attention because this particulate matters are suspected being hazardous of human health. In this study, The nano-PM mass and size of diesel passenger vehicles were measured on chassis dynamometer test bench. The particulate matters(PM) emissions of these vehicles were investigated by number concentration too. A condensation particle counter(CPC) system was applied to measure the particle number and size concentration of diesel exhaust particles at the end of dilution tunnel along the NEDC(ECE15+EUDC) and CVS-75 vehicle test mode. As the research result, the characteristic of vehicle test mode on the diesel nano-particle number and size distribution was investigated in this study.

In Situ Estimation of the Constituents of Green Soybean (Edamame) Pod using Near-Infrared Transmission Spectroscopy

  • Suzuki, Michiru;Katahira, Mitsuhiko;Natsuga, Motoyasu
    • Journal of Biosystems Engineering
    • /
    • v.39 no.4
    • /
    • pp.352-356
    • /
    • 2014
  • Purpose: We estimated the dietary qualities of green soybean (edamame) by using a specialized NIR transmission spectrometer to determine the constitutive properties of the soybean, such as the sucrose content and ninhydrine reaction quantity (NRQ; defined by the ninhydrine reaction, which has a high positive correlation with the total free amino acids), with the purpose of establishing a quality assurance system. Methods: We used a newly developed spectrometer probe that enables in situ estimation of the constituents of the soybean. Results: The calibration results obtained using a wavelength range of 760-960 nm were characterized by $R^2$ = 0.57 and standard error of cross-validation (SECV) of 0.78% for sucrose, and $R^2$ = 0.59 and SECV = 0.35% for NRQ. Conclusions: These results are inferior to those of our previous study obtained using a specialized bench-type transmission spectrometer. The poorer results are attributed to several possible reasons, including the effect of direct sunlight and the unstable sample presentation. We plan to conduct further study using improved optical layout and sample presentation.

Performance characteristics of a multi type refrigerator (R600a를 이용한 소형 멀티형 냉장고 시스템의 성능특성에 대한 실험적 연구)

  • Ahn, Ji-Hoon;Jang, Yong-Hee;Kim, Yong-Chan;Jang, Ui-Young;Park, Yong-Jong
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.292-297
    • /
    • 2008
  • Various types of refrigerators become popular in the market such as a common refrigerator, kimchi refrigerator and wine cellar. It is required to develop a multi function refrigerator which has different purposes in each evaporator. In this study, the performance of a multi type refrigerator system, which consists of one machine room and three evaporators, was measured in a bench type multi refrigerator. The multi type refrigerator system was tested by varying the number of refrigerator cabinet, refrigerant charge amount, temperature condition. Based on experimental data, the multi type refrigerator showed better performance than the conventional refrigerator(single type) At the same external load condition, the COP of the multi type refrigerator was $1.22{\sim}1.29$, but the COP of the single type refrigerator was 1.0.

  • PDF

A Study on Performance Evaluation of Container-based Virtualization for Real-Time Data Analysis (실시간 데이터 분석을 위한 컨테이너 기반 가상화 성능에 관한 연구)

  • Choi, BoAh;Han, JaeDeok;Oh, DaSom;Park, HyunKook;Kim, HyeonA;Seo, MinKwan;Lee, JongHyuk
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2020.05a
    • /
    • pp.32-35
    • /
    • 2020
  • 본 논문은 실시간 데이터 분석을 위한 컨테이너 가상화 기술 사용에 대한 효용성을 알아보기 위해 HDP 와 MapR 배포판에 포함된 Spark 를 도커라이징 전과 후 환경에 설치 후 HiBench 벤치마크 프로그램을 이용해 성능을 측정하였다. 그리고 성능 측정치에 대해 대응표본 t 검정을 이용하여 도커라이징 전과 후의 성능 차이가 있는지를 통계적으로 분석하였다. 분석 결과, HDP 는 도커라이징 전과 후에 대한 성능 차이가 있었지만 MapR 은 성능 차이가 없었다.

A Feedback Control of Pump-Controlled Electro-Hydrostatic Actuation System (펌프 가변제어기반 유압시스템의 피드백 제어)

  • Ryu, Jae-Kwan;Seo, Hyung-Tae
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.10
    • /
    • pp.837-843
    • /
    • 2016
  • This paper presents a position control strategy for a pump-controlled electro-hydrostatic actuator (EHA) using feedforward control with disturbance compensation. As the disturbance observer is used to estimate nonlinear dynamics of EHA, which has valve-opening conditionals, as well as external disturbances, an additional feedforward control is adopted to achieve rapid response. The effectiveness of the proposed control strategy is verified through experiment using an EHA test bench. The proposed controller shows better tracking performance compared with a conventional PID controller.

Incineration of Waste Water Sludge and Coal In a Circulating Fluidized Bed Combustor (순환유동층에서 폐수슬러지와 석탄의 혼소 특성)

  • Bae, Dal-Hee;Shun, Do-Won;Park, Jae-Hyeon;Ryu, Ho-Jung;Park, Do-Hyun
    • 한국연소학회:학술대회논문집
    • /
    • 2004.06a
    • /
    • pp.165-172
    • /
    • 2004
  • Co-incineration of coal and wastewater sludge was r;erfonn:rl in a O.lMWth bench scale circulating fluidized bed combustor(CFBC) Sludge was received from a wastewater treatment plant in a dye industrial complex in Busan. Metropolis. Moisture content of received sludge was 80%. Coal and sludge mixture was prepared with weight ratio of 90/10, 85/15 and 80/20. Co-combustion characteristics of the coal and sludge mixture demonstrated stable combustion conditions. Component analysis, incineration characteristics, boiler performance was measured before and after the test and application for commercial 59MWth CFBC boiler. The release of hazardous components such as $SO_2$ and Cl was suppressed by the presence of inherent minerals of Ca, Na, K in coal and sludge mixture. Pre-drying was not essential but it was recommended for the benefits of manageability of sludge.

  • PDF