HFC32/HFC125 혼합냉매의 히트펌프 성능 평가 (Performance of HFC32/HFC125 Mixtures for Heat Pumps)

  • 김욱진;강동규;이요한;정동수
    • 설비공학논문집
    • /
    • 제23권12호
    • /
    • pp.791-798
    • /
    • 2011
  • In this study, performance of R410A(50%R32/50%R125) and HFC32/HFC125 mixture is measured to examine the effect of composition shift of R410A used for various air-conditioners and heat pumps. The composition of HFC32/HFC125 mixture varies from the reference composition of R410A ${\pm}10%$ with 5% interval. Tests carried out in a heat pump bench tester at the evaporation and condensation temperatures of $7/45^{\circ}C$ and $-7/41^{\circ}C$ for summer and winter conditions, respectively. Test results show that both the coefficient of performance (COP) and compressor power of the HFC32/HFC125 mixture have the maximum difference of 2.0% as compared to those of R410A. Compressor discharge temperatures of HFC32/HFC125 mixture are increased up to $6.7^{\circ}C$ as compared to that of R410A. The amount of charge for HFC32/HFC125 mixture vary within 5.6% as compared to that of R410A. Overall, performance of R410A is not appreciably affected by the composition shift of ${\pm}10%$ of R32 under both air-conditioning and heat pumping conditions.

가정용 냉방기의 대체 냉매 성능 분석을 위한 전산 해석 연구 (Computer Simulation Study for Analyzing Alternative Refrigerants in Residential Air-conditioners)

  • 유환규;정동수
    • 태양에너지
    • /
    • 제15권3호
    • /
    • pp.75-90
    • /
    • 1995
  • 본 논문은 가정용 냉방기에 널리 사용되고 있는 HCFC22를 대체할 수 있는 혼합냉매의 개발 및 이들의 성능 연구에 관한 것이다. 현재까지 HCFC22를 대체할 수 있는 순수냉매가 없으므로, 혼합냉매 개발에 본 연구의 초점이 맞추어졌고, 이를 위해 가정용 냉방기를 모사 하는 컴퓨터 프로그램이 개발되었다. 연구에서 개발된 혼합냉매를 구성하는 순수냉매들은 다음과 같다: R32, R124, R125, R134, R134a, R143a, R152a. 컴퓨터 모사 결과들은 다음의 혼합냉매들에 대해서 발표되었다: R32/R134a, R32/R152a, R32/R134, R32/R124, R143a/R134a, R143a/R152a, R143a/R124, R125/R134a, R125/R152a, R125/R124, R32/R152a/R134a, R32/R152a/R134, R32/R152a/R124. 가장 좋은 에너지 효율을 보인 것은 삼원 혼합냉매인 R32/R152a/R124로서, HCFC22에 비해 이것의 성적 계수는 13.7% 높고 냉동 능력은 23% 낮은 것으로 판명되었다. 한편 이원 혼합냉매 중 가장 성능이 좋은 것은 R32/R124로서 이것의 성적 계수는 HCFC22에 비해 13.4% 높고 냉동 체적 용량은 9.6% 낮은 것으로 판명되었다.

  • PDF

R22의 대체냉매를 사용한 공기조화기의 성능 시뮬레이션 (Cycle Simulation of the Air-Conditioner Using Alternatives to R22)

  • 장세동;노승탁
    • 설비공학논문집
    • /
    • 제6권1호
    • /
    • pp.47-53
    • /
    • 1994
  • Cycle simulation of the air-conditioner was carried out using a number of candidate alternatives to R22;R32/R125/R134a(30/10/60, by mass percent), R32/R125/R134a(10/70/20), R32/R134a(25/75), R32/R134a(30/70), R32/R125(60/40), R290(propane) and R134a. In this study, we considered only the basic parts of the air-conditioner such as the compressor, the evaporator, the condenser and the capillary tube, for the purpose of analysis. The performance characteristics of alternatives considered here were examined by comparing with the case using R22 at the constant volumetric flow rate condition. The results of our analysis revealed that the use of refrigerant mixtures, R32/R134a(30/70) and R32/R125/R134a(30/10/60), was appropriate for the alternatives to R22 in view of the cooling capacity and the COP. For the case of using R134a and R290, the COP was observed to increase under the same volumetric flow rate condition, but the cooling capacity was substantially decreased. Therefore the use of R134a and R290 should be accompanied with increasing considerably the size of compressor in order to maintain the same cooling capacity of R22.

  • PDF

Regulation of IL-6 signaling by miR-125a and let-7e in endothelial cells controls vasculogenic mimicry formation of breast cancer cells

  • Park, Youngsook;Kim, Jongmin
    • BMB Reports
    • /
    • 제52권3호
    • /
    • pp.214-219
    • /
    • 2019
  • The role of tumor-proximal factors in tumor plasticity during chemoresistance and metastasis following chemotherapy is well studied. However, the role of endothelial cell (EC) derived paracrine factors in tumor plasticity, their effect on chemotherapeutic outcome, and the mechanism by which these paracrine factors modulate the tumor microenvironment are not well understood. In this study, we report a novel mechanism by which endothelial miR-125a and let-7e-mediated regulation of interleukin-6 (IL-6) signaling can manipulate vasculogenic mimicry (VM) formation of MDA-MB-231 breast cancer cells. We found that endothelial IL-6 levels were significantly higher in response to cisplatin treatment, whereas levels of IL-6 upon cisplatin exposure remained unchanged in MDA-MB-231 breast cancer cells. We additionally found an inverse correlation between IL-6 and miR-125a/let-7e expression levels in cisplatin treated ECs. Interestingly, IL-6, IL-6 receptor (IL-6R), and signal transducer and activator of transcription 3 (STAT3) genes in the IL-6 pathway are closely regulated by miR-125a and let-7e, which directly target its 3' untranslated region. Functional analyses revealed that endothelial miR-125a and let-7e inhibit IL-6-induced adhesion of monocytes to ECs. Furthermore, conditioned medium from cisplatin treated ECs induced a significantly higher formation of VM in MDA-MB-231 breast cancer cells as compared to that from intact ECs; this effect of cisplatin treatment was abrogated by concurrent overexpression of miR-125a and let-7e. Overall, this study reveals a novel EC-tumor cell crosstalk mediated by the endothelial miR-125a/let-7e-IL-6 signaling axis, which might improve chemosensitivity and provide potential therapeutic targets for the treatment of cancer.

HFC 순수냉매 및 혼합냉매의 모세관내에서 마찰에 의한 압력강하 (Frictional Pressure Drop of a Capillary Tube Flow of Pure HFC Refrigerants and Their Mixtures)

  • 장세동;노승탁
    • 설비공학논문집
    • /
    • 제7권4호
    • /
    • pp.589-599
    • /
    • 1995
  • The frictional pressure drop of a capillary tube flow is experimentally investigated for pure refrigerants such as R32, R125, and R134a and refrigerant mixtures such as R32/R134a(30/70 by mass percent), R32/R125(60/40), R125/R134a(30/70), and R32/R125/R134a(23/25/52). The binary interaction parameters for the calculation of viscosities of refrigerant mixtures are found based upon the data in the open literature. Several homogeneous flow models predicting the viscosity of two-phase region are compared to select the best model. Cicchitti's equation is known to be the most adequate for the prediction of the viscosity for refrigerant mixtures, which is used in the analysis of adiabatic capillary flows. A model for the prediction of the frictional pressure drop of single and two-phase flow is developed for refrigerant mixtures in this study. This model may be used to design and analyze the performance of a capillary tube in the refrigerating system.

  • PDF

일부 농촌지역 주민에서 혈청 CA19-9 및 CA125 농도에 영향을 미치는 인자에 관한 연구 (Factors Related to Serum Level of Carbohydrate Antigen 19-9 and Cancer Antigen 125 in Healthy Rural Populations in Korea)

  • 이수근;유근영;박수경;강대희;김진규;정준기;이명철
    • 대한핵의학회지
    • /
    • 제32권1호
    • /
    • pp.71-80
    • /
    • 1998
  • 우리 나라의 일부 지역 주민에서 혈청 CA19-9과 CA125 농도의 분포를 관찰함으로써 경계치 설정 이전에 미리 예비적 자료를 확보하고, 두 종양표지자의 측정치에 영향을 미치는 인자들, 특히 음주와 흡연 습관에 대한 통계적 유의성을 평가하기 위해 단시적 조사연구를 시도하였다. 1995년에 일부 농촌지역 성인 171명(남자 76명, 여자 95명)을 대상으로 하여 설문조사와 혈청 검사를 통해 개개인의 음주, 흡연습관 및 생식요인에 관한 정보 및 혈청 CA19-9 및 CA125 농도를 분석한 결과는 다음과 같다. 1) 혈청 CA19-9 농도의 평균 및 표준편차는 남녀 각각 $10.4{\pm}11.1{\mu}/ml$, $10.1{\pm}10.0{\mu}/ml$로 남녀간의 차이가 없었으나, 혈청 CA125 농도의 평균 및 표준편차는 각각 $2.5{\pm}12.2{\mu}/ml$, $11.2{\pm}7.4{\mu}/ml$로 여자에서 높았다. 한편 현재 임상적으로 적용되고 있는 양성판정치를 근거로 하여 판정한 혈청 CA19-9 및 CA125 양성률은 각각 2.9%, 1.8%이었으며, 각각 남녀간에 통계적으로 유의한 차이는 없었다. 2) 혈청 CA19-9 농도는 일일 흡연량(r=0.23, p=0.054) 및 총 흡연량(r=0.28, p=0.017)과 양의 상관관계를 보였으며, 성별로는 여자에서만 유의한 상관관계를 나타내었다(일일흡연량 r=0.59, p=.0.026 ; 총흡연량 r=0.74, p=0.003). 3) 혈청 CA125 농도는 흡연시작연령(r=0.51, p=0.000) 과는 양의 상관관계를, 총흡연기간(r=-0.23, p=0.051) 및 총흡연량(r=-0.23, p=0.057)과는 음의 상관관계를 보였는데, 성별로는 남자에서만 흡연시작연령(r=0.28, p=0.031)과 유의한 상관관계를 나타내었다. 4) 혈청 CA125 농도는 여자에서 연령(r=-0.20, p=0.058), 생리중단 연령(r=-0.28, p=0.030), 총수유기간(r=-0.29, p=0.014)과 음의 상관관계를 보였다. 5) 혈청 CA19-9 및 CA125 농도는 비만, 학력, 그리고 음주와 유의한 상관관계가 없었으며, 여자에서는 혈청 CA19-9 및 CA125 농도간에 양의 상관관계를 보였다(r=0.20, p=0.047). 6) 연령 및 비만의 교란효과를 통제하기 위한 중회귀분석 결과, 혈청 CA19-9 농도와 유의한 회귀관계를 보이는 변수는 없었다. 이에 비해 혈청 CA125 농도는 전체대상례에선 흡연시작연령이 빠르거나(p=0.000), 총 흡연기간이 길거나(p=0.001), 총흡연량이 많거나(p=0.020), 생리중단연령이 늦거나(p=0.035), 수유를 오래 할수록(p=0.050) 감소하는 것으로 나타났으나, 성별로 분석하였을 때 여자에서 흡연인자들의 유의한 회귀관계가 모두 소실되었다. 결론적으로, 혈청 CA19-9 농도는 흡연, 음주, 월경-출산관련 변수들에 의해 영향을 받는 않는 것으로 보여 실제 임상에 적용할 때 이들 변수를 고려하지 않고도 이용될 수 있는 비교적 안정된 종양표지자로 생각된다. 이에 비해 혈청 CA125 농도는 흡연량이 증가할수록 감소하는 경향을 보였으나 연령과 비만지수에 따라 흡연량이 교란영향을 받고 있는 지표임을 알 수 있었다. 한편, 여성에서는 폐경연령과 총수유기간이 유의한 관계를 보여 향후 정상치역 결정시 생리, 수유 등의 변수를 고려해야 할 것으로 사료된다.

  • PDF

R22 대체냉매의 성능 평가 (Performance evaluation of R22 alternative refrigerants)

  • 송용재;박봉진;정동수;김종보
    • 설비공학논문집
    • /
    • 제10권3호
    • /
    • pp.292-302
    • /
    • 1998
  • In this study, 14 refrigerant mixtures composed of R32, R125, R134a, R143a, R152a, and R1270(Propylene) were tested in a breadboard heat pump in an attempt to replace R22 used in most of the residential air conditioners and heat pumps. The heat pump was of 1 ton capacity and water was employed as the secondary heat transfer fluids. All tests were conducted under ARI test A condition. Ternary mixtures composed of R32, R125, and R134a were shown to have 4∼5% higher COP and capacity than R22 and hence they seem to be very promising candidates to replace R22. On the other hand, ternary mixtures containing R125, R134a, and R152a have lower COP and capacity than R22. R32/R134a binary mixtures show a 7% increase in COP and have the similar capacity to that of R22 and hence they are also good candidates to replace R22. Special care must be exercised when a suction line heat exchanger is used with these mixtures in air conditioners. Finally, the compressor discharge temperatures of all mixtures tested were lower than those of R22 by 15.g∼34.7t, which indicates that these mixtures would offer better system reliability and longer life time than R22.

  • PDF

재조합 인간 상피세포성장인자(DWP401)의 흰쥐에서의 in vivo와 in vitro 대사 (In vivo and In vitro Metabolism of Recombinant Human Epidermal Growth Factor (DWP401) in Rats)

  • 고여욱;남권호;정주영;박승국;유영효;김재환;한건;박명환;심창구
    • 약학회지
    • /
    • 제41권3호
    • /
    • pp.381-388
    • /
    • 1997
  • Metabolism of DWP401, recombinant juman epidermal growth factor, was examined in vivo and in vitro in rats. When $^{125}I$-labeled DWP401 was administered at a dose of 50 ${\mu}g$/kg by i.v. injection. $^{125}I$-labeled DWP401 was rapidly degraded within 30 minytes above 93%. Thin layer chromatography analysis of urine collected for 24 hr after i.v. administration of $^{125}I$-labeled DWP401 showed ohly one spot on a X-ray film which was considered as diiodo-tyrosine. This result suggests tha $^{125}I$-labeled DWP401 was completely digested into free amino acids without any specific intermediate polypeptides. About 42.1% of the administered iodine was recovered in 24 hr. For in vitro degradation study, $^{125}I$-labeled DWP401 was added to plama and tissue homogenates of rats and incubated at $37^{\circ}C$. Almost 98% of the added radioactivity recovered from the protein fraction of the liver, kidey, small intestine, stomach and spleen decreased rapidly. For examplem the recovery rates of $^{125}I$-labeled DWP401 were 58.6, 63.2, 39.9, 52.9 and 66.8% after 4hrs of incubation in respective organ homogenates.

  • PDF

삼중 혼합 냉매 R407C의 핵비등 열전달 특성에 관한 실험적 연구 (An experimental study on nucleate boiling of ternary refrigerant R407C)

  • 김성훈;곽경민;배철호;정모
    • 설비공학논문집
    • /
    • 제9권3호
    • /
    • pp.276-283
    • /
    • 1997
  • The nucleate boiling heat transfer experiments are performed using a ternary refrigerant R407C which is a candidate of alternatives of HCFC 22. The boiling phenomena for R-32, R-125, and R-134a which are the constituent refrigerants of R407C are also investigated to give the foundation of theoretical research for the mixture component boiling. The nucleate boiling heat transfer coefficients of R407C is less than those of HCFC 22 which has the similar physical and transport properties. Since the experimental results show the deterioration of boiling heat transfer coefficients of ternary mixture refrigerants R407C, the boiling heat transfer coefficients of R407C cannot be obtained by the linear combination of boiling heat transfer coefficients from its constituent components R-32, R125, and R134a.

  • PDF