• Title/Summary/Keyword: R-피크

Search Result 188, Processing Time 0.025 seconds

Premature Ventricular Contraction Classification through R Peak Pattern and RR Interval based on Optimal R Wave Detection (최적 R파 검출 기반의 R피크 패턴과 RR간격을 통한 조기심실수축 분류)

  • Cho, Ik-sung;Kwon, Hyeog-soong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.2
    • /
    • pp.233-242
    • /
    • 2018
  • Previous works for detecting arrhythmia have mostly used nonlinear method such as artificial neural network, fuzzy theory, support vector machine to increase classification accuracy. Most methods require higher computational cost and larger processing time. Therefore it is necessary to design efficient algorithm that classifies PVC(premature ventricular contraction) and decreases computational cost by accurately detecting feature point based on only R peak through optimal R wave. For this purpose, we detected R wave through optimal threshold value and extracted RR interval and R peak pattern from noise-free ECG signal through the preprocessing method. Also, we classified PVC in realtime through RR interval and R peak pattern. The performance of R wave detection and PVC classification is evaluated by using 9 record of MIT-BIH arrhythmia database that included over 30. The achieved scores indicate the average of 99.02% in R wave detection and the rate of 94.85% in PVC classification.

Noise-robust electrocardiogram R-peak detection with adaptive filter and variable threshold (적응형 필터와 가변 임계값을 적용하여 잡음에 강인한 심전도 R-피크 검출)

  • Rahman, MD Saifur;Choi, Chul-Hyung;Kim, Si-Kyung;Park, In-Deok;Kim, Young-Pil
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.12
    • /
    • pp.126-134
    • /
    • 2017
  • There have been numerous studies on extracting the R-peak from electrocardiogram (ECG) signals. However, most of the detection methods are complicated to implement in a real-time portable electrocardiograph device and have the disadvantage of requiring a large amount of calculations. R-peak detection requires pre-processing and post-processing related to baseline drift and the removal of noise from the commercial power supply for ECG data. An adaptive filter technique is widely used for R-peak detection, but the R-peak value cannot be detected when the input is lower than a threshold value. Moreover, there is a problem in detecting the P-peak and T-peak values due to the derivation of an erroneous threshold value as a result of noise. We propose a robust R-peak detection algorithm with low complexity and simple computation to solve these problems. The proposed scheme removes the baseline drift in ECG signals using an adaptive filter to solve the problems involved in threshold extraction. We also propose a technique to extract the appropriate threshold value automatically using the minimum and maximum values of the filtered ECG signal. To detect the R-peak from the ECG signal, we propose a threshold neighborhood search technique. Through experiments, we confirmed the improvement of the R-peak detection accuracy of the proposed method and achieved a detection speed that is suitable for a mobile system by reducing the amount of calculation. The experimental results show that the heart rate detection accuracy and sensitivity were very high (about 100%).

A photoplythsmography starting point detection algorithm for pulse wave velocity (맥파속도 측정을 위한 PPG 기시점 검출알고리즘)

  • Jeong, Seokhoon;Ko, Kuk Won;Lee, Sangjoon
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2015.10a
    • /
    • pp.949-951
    • /
    • 2015
  • 본 연구는 맥파속도를 측정 하는데 간단한 방법으로 1채널 심전도 데이터와 4채널 광전식 용적맥파를 이용하여 취득한 데이터를 분석하는 알고리즘을 제안한다. 심전도의 R 피크점과 좌우 지첨, 족첨에서 발생하는 4 채널 맥파신호간 시간차를 이용하여 맥파 전달시간을 구하고 팔, 다리 길이로 나눠서 맥파전달속도를 구한다. 알고리즘은 심전도 R 피크점 검출, 4 채널 맥파에서의 피크점 검출 이후 검출된 피크정보를 이용하여 맥파의 시작지점인 기시점을 검출하는 간단한 방법을 개발하였고, 4 가지 맥파형태에 검출알고리즘을 적용하여 검증 하였다. 본 연구에서 개발한 방법으로 간단히 맥파속도를 측정하여 동맥경화나 고혈압, 당뇨 등 심혈관 관련 연구의 기반이 될 수 있을 것으로 사료된다.

Detection of ECG Signal Waveform for Arrhythmia Classification (부정맥 분류를 위한 ECG 신호의 파형검출 알고리즘)

  • Min, Chul-Hong;Kim, Tae-Seon
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.453-456
    • /
    • 2005
  • 일반적으로 심전도는 심장계통의 질환을 판단할 때 사용된다. 이러한 심장질환의 이상 유무를 자동으로 진단하기 위해서는 QRS파형 검출을 필요로 하며, 이를 위하여 웨이블렛변환 방법이나 템플릿매칭, 룰 베이스 방법 등 여러 가지 방법들이 쓰이고 있으나, 심전도 신호가 표준화된 형태를 갖지 않는 경우는 검출 능력에 많은 한계를 갖고 있다. 본 논문은 파형의 베이스라인(baseline)을 기준으로 진폭 값에 절대치을 취하는 방법으로 파형의 R피크값을 검출하는 알고리즘을 제안한다. 결과를 검증하기 위해 MIT-BIH 데이타베이스에서 제공하는 데이터와 R피크값을 본 논문의 알고리즘으로 추출된 R피크값과 비교한 결과 96.7%의 검출률을 보였다.

  • PDF

R-peak Detection Algorithm in Wireless Sensor Node for Ubiquitous Healthcare Application (유비쿼터스 헬스케어 시스템을 위한 노드기반의 R피크 검출 알고리즘)

  • Lee, Dae-Seok;Hwang, Gi-Hyun;Cha, Kyoung-Hwan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.1
    • /
    • pp.227-232
    • /
    • 2011
  • The QRS complex in ECG analysis is possible to obtain much information that is helpful for diagnosing different types of cardiovascular disease. This paper presents the preprocessor method to detect R-peak, RR interval, and HRV in wireless sensor node. The derivative of the electrocardiogram is efficiency of preprocessing method for resource hungry wireless sensor node with low computation. We have implemented R-peak and RR interval detection application based on dECG for wireless sensor node. The sensor node only transfers meaning parameter of ECG. Thus, implementation of sensor node can save power, reduce traffic, and eliminate congestion in a WSN.

Growth and Anthocyanins of Lettuce Grown under Red or Blue Light-emitting Diodes with Distinct Peak Wavelength (상이한 피크파장의 적색광 및 청색광 발광다이오드 조사에 따른 상추의 생장 및 안토시아닌)

  • Lee, Jae Su;Kim, Yong Hyeon
    • Horticultural Science & Technology
    • /
    • v.32 no.3
    • /
    • pp.330-339
    • /
    • 2014
  • Growth and anthocyanins of lettuce (Lactuca sativa L., 'Mid-season') grown under LED lamps with blue light in the range of 430-470 nm or with red light in the range of 630-670 nm were analyzed in this study. Cool-white fluorescent light was used a s the control. P hotosynthetic photon flux, p hotoperiod, air temperature, relative humidity, and $CO_2$ concentration in a closed plant production system were $201{\pm}2\;{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$, 16/8 hours (day/night), $22/18^{\circ}C$, 70%, and $400{\mu}mol{\cdot}mol^{-1}$, respectively. At 21 days after light quality treatment, growth characteristics and anthocyanins content of lettuce as affected by the peak wavelength of blue or red LED were significantly different. Among peak wavelengths treated in this stusy, R1 treatment (peak wavelength 634 nm) and R6 treatment (peak wavelength 659 nm) were effective for increasing leaf width, leaf area, shoot fresh weight, and photosynthetic rate of lettuce. B5 treatment (peak wavelength 450 nm) and B4 treatment (peak wavelength 446 nm) increased the anthocyanins concentration and chlorophyll content in lettuce leaves, respectively. Anthocyanins in lettuce leaves increased linearly with decreasing hue value of leaf color and with increasing SPAD value of lettuce leaves. From these results, it was concluded that the red LED with peak wavelengths of 634 nm and 659 nm and the blue LED with peak wavelengths of 450 nm can be used as potential light spectra for increasing the yield and anthocyanins accumulation of leafy vegetable.

A study of R peak signal detection using Wavelet and Threshold (웨이블릿 변환과 문턱치를 이용한 R 피크 검출 연구)

  • seo, jung ick
    • Journal of the Korea society of information convergence
    • /
    • v.6 no.1
    • /
    • pp.1-6
    • /
    • 2013
  • The electrocardiogram(ECG) is widely used for the diagnosis of heart disease recent. In order to correct diagnosis, wavelet and thresholding is studied. In this study, we study hard inverse thresholding that is apply the existing hard thresholding. It apply to hard inverse thresholding on Pan-Tomkins algorism, that was simplified. The results of mit-bih No. 103 ECG signal is detected R peaks was detected unaffected by signal distortion and noise.

  • PDF

Implementation for Gated Peak Detector of CSAM based on One Chip Processor (원 칩 프로세서 기반의 CSAM 의 게이트 피크 검출 구현)

  • Lar, Ki Kong;Ryu, Conan K.R.;Hur, Chang-Wu;Sun, Mingui
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.10a
    • /
    • pp.776-779
    • /
    • 2010
  • Implementation for Gated Peak Detector CSAM (C Scanning Acoustic Microscope) based on One Chip processor is proposed in this paper. GDP (Gated Peak Detector) is implemented with VHDL tool. The proposed method leads to be available for its application and integration in all systems as well as acoustic microscope and the method is compared with the conventional methods. The technique results in efficiency in size and application.

  • PDF

Fabrication of the Noninvasive Tube Voltage Meter of Radiotherapy Simulator and Its Performance Analysis (방사선치료 시뮬레이터의 비접속형관전압계 제작과 성능분석)

  • Kim, Jong-Eon;Yoon, Chun-Sil;Kim, Sung-Hyun;Park, Chang-Hee;Cha, Byung-Youl
    • Progress in Medical Physics
    • /
    • v.17 no.4
    • /
    • pp.201-206
    • /
    • 2006
  • In this study, we have fabricated the noninvasive tube voltage meter which can observe the waveform of tube voltage and measure the tube voltage by using the Intensity of X-ray beam irradiated from radiotherapy simulator and also investigated the feasibility for clinical applications. Two pin photodiodes acting as X-ray detectors were arranged in parallel at the position of ${\pm}1.4cm$ in the y-axis of X-ray field and the aluminum filters with different thickness were placed above them. Using this detector, we could get the ratio ($r_{eff}$) of the relative output voltage which is proportional to the thickness of the filters. And the logarithm of effective peak tube voltage ($InkV_{p,eff}$) was obtained by Victoreen's NERO 6000M used as reference tube voltage meter. From the linear regression analysis of $r_{eff}$ and In $kV_{p,eff}$ the correlation coefficient (r) of linear equation was obtained to be 0.996 for the calibration of the tube voltage meter. Therefore, we suggest that the noninvasive tube voltage meter fabricated in this study can be used for clinical applications due to Its high accuracy.

  • PDF

A readout method using pulse peak-time capture for radiation detectors (펄스의 피크시각 포착을 이용한 방사선 검출기의 신호처리 방법)

  • Kim, Jong-ho;Kwon, Young-mok;Hong, Hyoung-pyo;Che, Gyu-shik
    • Journal of Advanced Navigation Technology
    • /
    • v.21 no.6
    • /
    • pp.651-658
    • /
    • 2017
  • There were many studies on the development of radiation measuring instruments to detect the presence of radiation. In particular, the signal processing method and treatment without loss of the detection signal are very important. The common feature for these studies is the peak-hold method that keeps the peak value of input signal uniform for a short time, readouts its value, discharges electrical value, and then waits for next signal. We propose the new methodology to capture the pulse peak value from the radiation detector and read the value directly other than peak-hold method. This method has merit of accurate reading the input signal pulse peak value without complicate process of holding for a period or initializing of input signal, and then be verified to be adequate through simulation of actual example.