관상동맥질환을 진단하기 위한 R파와 T파의 크기에 대한 연구 (R and T Wave Amplitude as a Parameter to Detect Coronary Artery Disease)

  • 임현균;유권규;김진목;김인선;강찬석;박용기
    • Progress in Superconductivity
    • /
    • 제10권1호
    • /
    • pp.6-11
    • /
    • 2008
  • Multi-channel magnetocardiography (MCG) has been proposed to detect ischemic heart disease because its sensitivity is quite high comparing with other conventional diagnostic tools. Especially, current map and magnetic field map of MCG provide crucial information on whether myocardiac muscles maintain the normal conduction pathway. In addition, MCG parameters derived from repolarization are useful to detect coronary artery disease. Recently, there was a study reporting that R- and T- wave amplitude are highly correlated with ischemic heart disease. In this study, we studied R- and T-wave amplitude and their ratio as well as MCG parameters. MCG data from 20 young, 20 age-matched controls, and 20 myocardial infarction (MI) patients were analyzed. As a result, MCG parameters showed significant change in MI patients comparing to those of controls. R- and T-wave amplitude of MI patients showed a feature of severe ischemic heart disease even though it was difficult to find consistent values. Further study is needed to reveal the relations between small T-wave amplitude and coronary artery disease.

  • PDF

Correlations Among Objective Measurements of Spasticity in Patients With Brain Lesions

  • Kim, Yong-Wook
    • 한국전문물리치료학회지
    • /
    • 제14권4호
    • /
    • pp.7-13
    • /
    • 2007
  • The purpose of this study was to investigate correlations among objective measurements of spasticity in patients with brain lesions. Thirty-two stroke and traumatic brain injury subjects participated in the study. Spasticity was quantified using the knee first flexion angle, relaxation index obtained from a pendulum drop test, and the amplitude of a knee tendon reflex test. Pearson's product correlation coefficient was used to examine relationships among these measurements of spasticity. There was a significant positive correlation between the relaxation index and knee first flexion angle in patients with brain lesions (r=.895, p<.01). There was also significant negative correlation between the amplitude of knee tendon reflex and relaxation index (r=-.612, p<.01), and between amplitude and knee first flexion angle (r=-.537, p<.01). Thus, it is possible to use the knee first flexion angle as an objective measure of spasticity, rather than relaxation index, which is more complicated to obtain. Further studies are needed to explore the effects of functional improvement and long-lasting carryover effects of spasticity using a simple objective measure such as the knee first flexion angle from a pendulum test.

  • PDF

능동형 횡동요 감쇠장치의 성능에 관한 연구 (A Study on the Performance of Active Anti-Rolling Tank Stabilizer System)

  • 최찬문;안장영;이창헌
    • 수산해양기술연구
    • /
    • 제40권2호
    • /
    • pp.138-143
    • /
    • 2004
  • 제주대학교 실습선 아라호에 정착된 능동형 횡동요 감쇠장치의 성능에 관해 연구하기 위하여 33$^{\circ}$00‘.44”N, 125$^{\circ}$59’.88 ”E 위치에서 선박을 정지한 후, 횡동요 감쇠장치를 정지 (Passive A.R.T), 작동 (Active A.R.T)을 했을 때 경사계에 의한 횡동요각 및 종동요각, 풍속계에 의한 풍속의 변화와 그리고 선박이 항해 중에 감쇠장치의 작동을 정지(Passive A.R.T), 작동(Active A.R.T) 했을 때 의 능동형 횡동요 감쇠장치의 성능을 분석한 결과에 대해 요약하면 다음과 같다. 1. 선박이 정지했을 때 횡동요 감쇠장치를 정지, 작동한 경우 횡동요각의 평균진폭 (Average Amplitude of Roll) 은 각각 8.30$^{\circ}$, 4.37$^{\circ}$, 횡동요각의 유의진폭(Significant Amplitude of Roll $_{{\pi}{1/3}}$)은 각각 10.10$^{\circ}$, 5.30$^{\circ}$으로 나타났다. 2. 선박이 항해 중 일 때에는 횡동요각의 평균진폭 (Average Amplitude of Roll)은 각각 5.01$^{\circ}$, 4.36$^{\circ}$, 횡동요각의 유의진폭 (Significant Amplitude of Roll$^{\circ}$) 은 각각 5.50$^{\circ}$, 5.10$^{\circ}$으로 각각 나타났다. 3. 횡동요 감쇠장치는 선박이 정치했을 때에는 47.5%, 선박이 운항 했을 때는 12.7% 정도의 감쇠 효율을 보여서 정지했을 때 그 효율이 높은 것으로 나타났다. 4. 횡동요 감쇠 장치는 종동요(Pitching)에 대해서는 거의 영향을 미치지 않았다.

Fourier Ptychographic Microscopy 영상에서의 딥러닝 기반 디지털 염색 방법 연구 (Deep Learning Based Digital Staining Method in Fourier Ptychographic Microscopy Image)

  • 황석민;김동범;김유정;김여린;이종하
    • 융합신호처리학회논문지
    • /
    • 제23권2호
    • /
    • pp.97-106
    • /
    • 2022
  • 본 연구에서 세포를 분별하기 위해 H&E 염색이 필요하다. 그러나 직접 염색하면 많은 비용과 시간이 필요하다. H&E 염색되지 않은 세포의 Phase image에서 H&E 염색이 된 세포의 Amplitude image로 변환 하는 것이 목적이다. FPM으로 촬영한 Image data를 가지고 Matlab을 이용해 매개변수를 변경해 Phase image와 Amplitude image를 만들었다. 정규화를 통해 육안으로 식별이 가능한 이미지를 얻었다. GAN 알고리즘을 이용해 Phase image를 기반으로 Real Amplitude image와 비슷한 Fake Amplitude image를 만들고 Fake Amplitude image를 가지고 MASK R-CNN을 이용하여 세포를 분별하여 객체화를 통해 구분했다. 연구 결과 D loss의 max는 3.3e-1, min은 6.8e-2, G loss max는 6.9e-2, min은 2.9e-2, A loss는 max 5.8e-1, min은 1.2e-1, Mask R-CNN max는 1.9e0, min은 3.2e-1이다.

복합근육활동전위의 시작잠복기와 진폭에 대한 기준전극의 영향 (The Influence of the Reference Electrode on Compound Muscle Action Potential Onset Latency and Amplitude)

  • 이상무;손종희;최휘철
    • Annals of Clinical Neurophysiology
    • /
    • 제12권1호
    • /
    • pp.11-15
    • /
    • 2010
  • Background: In belly-tendon (bipolar) montage, reference (R2) electrode placed on muscle's tendon has traditionally been considered to be electrically inactive. However, recent studies have revealed that R2 electrode is not simply referential, but actively contributes to compound muscle action potential (CMAP) waveform morphology. These findings suggest that CMAP onset latency and amplitude may also be influenced by the position of R2 electrode. This study was performed in order to evaluate the effect of R2 electrode position on CMAP onset latency and amplitude. Methods: We performed motor nerve conduction studies of median, ulnar, tibial and peroneal nerves on bilateral limbs of 20 normal subjects. We used traditional bipolar and monopolar montage and compared their CMAP onset latencies and amplitudes. In bipolar montage, recording (R1) electrode was placed on mid-belly of muscle with R2 electrode on the tendon of the muscle. In monopolar montage, R1 electrode was placed on the same site of bipolar montage, while R2 electrode was placed on the contralateral limb. Results: The mean CMAP onset latencies of median and peroneal nerves in bipolar montage were significantly different (p<0.05) with those in monopolar montage. And those of ulnar and tibial nerves were not significantly different (p>0.05). The mean CMAP amplitudes of all the tested nerves except ulnar nerve were significantly different (p<0.05). Conclusions: This study shows that change in R2 electrode position can affect the CMAP onset latency and amplitude, and these differences seem to be related to the generation of far field potential by CMAP.

안티푸라민-에스® 로션의 레올로지 특성 연구 (Rheological Properties of Antiphlamine-S® Lotion)

  • 국화윤;송기원
    • Journal of Pharmaceutical Investigation
    • /
    • 제39권3호
    • /
    • pp.185-199
    • /
    • 2009
  • Using a strain-controlled rheometer [Advanced Rheometric Expansion System (ARES)], the steady shear flow properties and the dynamic viscoelastic properties of $Antiphlamine-S^{(R)}$ lotion have been measured at $20^{\circ}C$ (storage temperature) and $37^{\circ}C$ (body temperature). In this article, the temperature dependence of the linear viscoelastic behavior was firstly reported from the experimental data obtained from a temperature-sweep test. The steady shear flow behavior was secondly reported and then the effect of shear rate on this behavior was discussed in detail. In addition, several inelastic-viscoplastic flow models including a yield stress parameter were employed to make a quantitative evaluation of the steady shear flow behavior, and then the applicability of these models was examined by calculating the various material parameters. The angular frequency dependence of the linear viscoelastic behavior was nextly explained and quantitatively predicted using a fractional derivative model. Finally, the strain amplitude dependence of the dynamic viscoelastic behavior was discussed in full to elucidate a nonlinear rheological behavior in large amplitude oscillatory shear flow fields. Main findings obtained from this study can be summarized as follows : (1) The linear viscoelastic behavior is almostly independent of temperature over a temperature range of $15{\sim}40^{circ}C$. (2) The steady shear viscosity is sharply decreased as an increase in shear rate, demonstrating a pronounced Non-Newtonian shear-thinning flow behavior. (3) The shear stress tends to approach a limiting constant value as a decrease in shear rate, exhibiting an existence of a yield stress. (4) The Herschel-Bulkley, Mizrahi-Berk and Heinz-Casson models are all applicable and have an equivalent validity to quantitatively describe the steady shear flow behavior of $Antiphlamine-S^{(R)}$ lotion whereas both the Bingham and Casson models do not give a good applicability. (5) In small amplitude oscillatory shear flow fields, the storage modulus is always greater than the loss modulus over an entire range of angular frequencies tested and both moduli show a slight dependence on angular frequency. This means that the linear viscoelastic behavior of $Antiphlamine-S^{(R)}$ lotion is dominated by an elastic nature rather than a viscous feature and that a gel-like structure is present in this system. (6) In large amplitude oscillatory shear flow fields, the storage modulus shows a nonlinear strain-thinning behavior at strain amplitude range larger than 10 % while the loss modulus exhibits a weak strain-overshoot behavior up to a strain amplitude of 50 % beyond which followed by a decrease in loss modulus with an increase in strain amplitude. (7) At sufficiently large strain amplitude range (${\gamma}_0$>100 %), the loss modulus is found to be greater than the storage modulus, indicating that a viscous property becomes superior to an elastic character in large shear deformations.

주기적으로 회전진동하는 원주 후류의 공진특성에 관한 연구 (Lock-on Characteristics of Wake Behind a Rotationally Oscillating Circular Cylinder)

  • 이정엽;이상준
    • 대한기계학회논문집B
    • /
    • 제29권8호
    • /
    • pp.895-902
    • /
    • 2005
  • Lock-on characteristics of flow around a circular cylinder oscillating rotationally with a relatively high forcing frequency have been investigated experimentally. Dominant governing parameters are Reynolds number (Re), angular amplitude of oscillation (${\theta}_A$), and frequency ratio $F_R=f_f/f_n,\;where\;f_f$ is a forcing frequency and $f_n$ is a natural frequency of vortex shedding. Experiments were carried out under the conditions of $Re=4.14{\times}10^3,\;{\pi}/90{\leq}{\theta_A}{\leq}{\pi}/3,\;and\;F_R=1.0$. The effect of this active flow control technique on the lock-on flow characteristics of the cylinder wake was evaluated with wake velocity measurements and spectral analysis of hot-wire signals. The rotational oscillation modifies the flow structure of near wake significantly. The lock-on phenomenon always occurs at $F_R=1.0$, regardless of the angular amplitude ${\theta}_A$. In addition, when the angular amplitude is less than a certain value, the lock-on characteristics appear only at $F_R=1.0$,. The range of lock-on phenomena expands and vortex formation length is decreased, as the angular amplitude increases. The rotational oscillation create a small-scale vortex structure in the region just near the cylinder surface. At ${\theta}_A=60^{\circ}$, the drag coefficient was reduced about $43.7\%$ at maximum.

Accurate Characterization of T/R Modules with Consideration of Amplitude/Phase Cross Effect in AESA Antenna Unit

  • Ahn, Chang-Soo;Chon, Sang-Mi;Kim, Seon-Joo;Kim, Young-Sik;Lee, Juseop
    • ETRI Journal
    • /
    • 제38권3호
    • /
    • pp.417-424
    • /
    • 2016
  • In this paper, an accurate characterization of a fabricated X-band transmit/receive module is described with the process of generating control data to correct amplitude and phase deviations in an active electronically scanned array antenna unit. In the characterization, quantization errors (from both a digitally controlled attenuator and a phase shifter) are considered using not theoretical values (due to discrete sets of amplitude and phase states) but measured values (of which implementation errors are a part). By using the presented procedure for the characterization, each initial control bit of both the attenuator and the phase shifter is closest to the required value for each array element position. In addition, each compensated control bit for the parasitic cross effect between amplitude and phase control is decided using the same procedure. Reduction of the peak sidelobe level of an array antenna is presented as an example to validate the proposed procedure.

주기적으로 회전진동하는 원주 후류의 공진특성 (Lock-on Characteristics of wake behind a Rotationally Oscillating Circular Cylinder)

  • 이정엽;이상준
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2004년도 추계학술대회 논문집
    • /
    • pp.18-21
    • /
    • 2004
  • Lock-on characteristics of the flow around a circular cylinder performing a rotationally oscillation with a relatively high forcing frequency have been investigated experimentally using flow visualization and hot-wire measurements. Dominant parameters are Reynolds number (Re), amplitude of oscillation $(\theta_A)$, and frequency ratio $F_R=f_f\;/\;f_n$, where $f_f$ is the forcing frequency and if is the natural frequency of vortex shedding. Experiments were carried out under the conditions of $Re=4.14\times10^3,\;\pi/15\leq\theta_A\leq\pi/3$, and $F_R=1.0$. The effects of this active control technique on the lock-on flow regime of the cylinder wake were evaluated through wake velocity measurements and spectral analysis of hot-wire signals. The rotary oscillation modified the flow structure of near wake significantly. The lock-on phenomenon was found to occur in the range of frequency encompassing the natural vortex shedding frequency. In addition, when the amplitude of oscillation is less than a certain value, the lock-on phenomenon was occurred only at $F_R=1.0$. The lock-on range expanded and vortex formation length decreased as the amplitude of oscillation increases. The rotary oscillation generated small-scale vortex structure just near the cylinder surface.

  • PDF

The relationship between nerve conduction studies and neuropathic pain in sciatic nerve injury due to intramuscular injection

  • Fidanci, Halit;Ozturk, Ilker
    • The Korean Journal of Pain
    • /
    • 제34권1호
    • /
    • pp.124-131
    • /
    • 2021
  • Background: Sciatic nerve injury due to intramuscular injection (SNIII) is still a health problem. This study aimed to determine whether there is a correlation between neuropathic pain and electrodiagnostic findings in SNIII. Methods: Patients whose clinical and electrodiagnostic findings were compatible with SNIII participated in this retrospective cohort study. Compound muscle action potential (CMAP) and sensory nerve action potential (SNAP) amplitudes of the sural, superficial peroneal, peroneal, and tibial nerves were graded from 1 to 4. Leeds assessment of neuropathic symptoms and signs scale (LANSS) was applied to all patients. Results: Forty-eight patients were included in the study, 67% of whom had a LANSS score ≥ 12. Sural SNAP amplitude abnormalities were present in 8 (50%) out of 16 patients with a LANSS score < 12, and 28 (87.5%) out of 32 patients with a LANSS score ≥ 12, with significant differences between the groups (P = 0.011). There was a positive correlation between the LANSS score and the sural SNAP amplitude grading (P = 0.001, r = 0.476). A similar positive correlation was also found in the LANSS score and the tibial nerve CMAP amplitude grading (P = 0.004, r = 0.410). Conclusions: This study showed a positive correlation between the severity of tibial nerve CMAP/sural SNAP amplitude abnormality and LANSS score in SNIII. Neuropathic pain may be more common in SNIII patients with sural nerve SNAP amplitude abnormality.