• Title/Summary/Keyword: R amplitude

Search Result 491, Processing Time 0.03 seconds

R and T Wave Amplitude as a Parameter to Detect Coronary Artery Disease (관상동맥질환을 진단하기 위한 R파와 T파의 크기에 대한 연구)

  • Lim, Hyun-Kyoon;Yu, Kwon-Kyu;Kim, Jin-Mok;Kim, In-Seon;Kang, Chan-Seok;Park, Yong-Ki
    • Progress in Superconductivity
    • /
    • v.10 no.1
    • /
    • pp.6-11
    • /
    • 2008
  • Multi-channel magnetocardiography (MCG) has been proposed to detect ischemic heart disease because its sensitivity is quite high comparing with other conventional diagnostic tools. Especially, current map and magnetic field map of MCG provide crucial information on whether myocardiac muscles maintain the normal conduction pathway. In addition, MCG parameters derived from repolarization are useful to detect coronary artery disease. Recently, there was a study reporting that R- and T- wave amplitude are highly correlated with ischemic heart disease. In this study, we studied R- and T-wave amplitude and their ratio as well as MCG parameters. MCG data from 20 young, 20 age-matched controls, and 20 myocardial infarction (MI) patients were analyzed. As a result, MCG parameters showed significant change in MI patients comparing to those of controls. R- and T-wave amplitude of MI patients showed a feature of severe ischemic heart disease even though it was difficult to find consistent values. Further study is needed to reveal the relations between small T-wave amplitude and coronary artery disease.

  • PDF

Correlations Among Objective Measurements of Spasticity in Patients With Brain Lesions

  • Kim, Yong-Wook
    • Physical Therapy Korea
    • /
    • v.14 no.4
    • /
    • pp.7-13
    • /
    • 2007
  • The purpose of this study was to investigate correlations among objective measurements of spasticity in patients with brain lesions. Thirty-two stroke and traumatic brain injury subjects participated in the study. Spasticity was quantified using the knee first flexion angle, relaxation index obtained from a pendulum drop test, and the amplitude of a knee tendon reflex test. Pearson's product correlation coefficient was used to examine relationships among these measurements of spasticity. There was a significant positive correlation between the relaxation index and knee first flexion angle in patients with brain lesions (r=.895, p<.01). There was also significant negative correlation between the amplitude of knee tendon reflex and relaxation index (r=-.612, p<.01), and between amplitude and knee first flexion angle (r=-.537, p<.01). Thus, it is possible to use the knee first flexion angle as an objective measure of spasticity, rather than relaxation index, which is more complicated to obtain. Further studies are needed to explore the effects of functional improvement and long-lasting carryover effects of spasticity using a simple objective measure such as the knee first flexion angle from a pendulum test.

  • PDF

A Study on the Performance of Active Anti-Rolling Tank Stabilizer System (능동형 횡동요 감쇠장치의 성능에 관한 연구)

  • Choi, Chan-Moon;Ahn, Jang-Young;Lee, Chang-Heon
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.40 no.2
    • /
    • pp.138-143
    • /
    • 2004
  • This experimental paper deals with the performance of tanks that are turned the active A.R.T(Anti-Rolling Tank) when the fluid transfers from wing tank to the opposite tank by the power developed by the automatic control system (INTERING Stabilizer), which was installed in the fishery training ship T/S. A - RA (G/T:990 tons) of Cheju National University. In this paper, the author has tested the performance of INTERING Stabilizer for the signals obtained by the inclinometer in irregular waves and compared with the results obtained in passive mode operation at stop and at various ship speeds. The performances of the system were confirmed the results as follows through the tests: 1. The average amplitude and significant roll (${\pi}$1/3) of the passive and active mode operations in the condition of stoped engine and underway were obtained 8.30$^{\circ}$, 4.37$^{\circ}$, 8.30$^{\circ}$, 4.37$^{\circ}$, and 5.01$^{\circ}$, 4.36$^{\circ}$, 5.50$^{\circ}$, 5.10$^{\circ}$, respectively. 2. The rates of performance of active mode operations were carried out during a sea trial in the condition of stop engine and underway resulted in 47.5%, 12.7%, respectively, therefore the active mode operation estimated to be improved more than passive mode operation. 3. Active - A.R.T by INTERING Stabilizer didn't affect the amplitude of pitching.

Deep Learning Based Digital Staining Method in Fourier Ptychographic Microscopy Image (Fourier Ptychographic Microscopy 영상에서의 딥러닝 기반 디지털 염색 방법 연구)

  • Seok-Min Hwang;Dong-Bum Kim;Yu-Jeong Kim;Yeo-Rin Kim;Jong-Ha Lee
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.23 no.2
    • /
    • pp.97-106
    • /
    • 2022
  • In this study, H&E staining is necessary to distinguish cells. However, dyeing directly requires a lot of money and time. The purpose is to convert the phase image of unstained cells to the amplitude image of stained cells. Image data taken with FPM was created with Phase image and Amplitude image using Matlab's parameters. Through normalization, a visually identifiable image was obtained. Through normalization, a visually distinguishable image was obtained. Using the GAN algorithm, a Fake Amplitude image similar to the Real Amplitude image was created based on the Phase image, and cells were distinguished by objectification using MASK R-CNN with the Fake Amplitude image As a result of the study, D loss max is 3.3e-1, min is 6.8e-2, G loss max is 6.9e-2, min is 2.9e-2, A loss max is 5.8e-1, min is 1.2e-1, Mask R-CNN max is 1.9e0, and min is 3.2e-1.

The Influence of the Reference Electrode on Compound Muscle Action Potential Onset Latency and Amplitude (복합근육활동전위의 시작잠복기와 진폭에 대한 기준전극의 영향)

  • Lee, Sang-Moo;Choi, Heui-Chul;Son, Jong-Hee
    • Annals of Clinical Neurophysiology
    • /
    • v.12 no.1
    • /
    • pp.11-15
    • /
    • 2010
  • Background: In belly-tendon (bipolar) montage, reference (R2) electrode placed on muscle's tendon has traditionally been considered to be electrically inactive. However, recent studies have revealed that R2 electrode is not simply referential, but actively contributes to compound muscle action potential (CMAP) waveform morphology. These findings suggest that CMAP onset latency and amplitude may also be influenced by the position of R2 electrode. This study was performed in order to evaluate the effect of R2 electrode position on CMAP onset latency and amplitude. Methods: We performed motor nerve conduction studies of median, ulnar, tibial and peroneal nerves on bilateral limbs of 20 normal subjects. We used traditional bipolar and monopolar montage and compared their CMAP onset latencies and amplitudes. In bipolar montage, recording (R1) electrode was placed on mid-belly of muscle with R2 electrode on the tendon of the muscle. In monopolar montage, R1 electrode was placed on the same site of bipolar montage, while R2 electrode was placed on the contralateral limb. Results: The mean CMAP onset latencies of median and peroneal nerves in bipolar montage were significantly different (p<0.05) with those in monopolar montage. And those of ulnar and tibial nerves were not significantly different (p>0.05). The mean CMAP amplitudes of all the tested nerves except ulnar nerve were significantly different (p<0.05). Conclusions: This study shows that change in R2 electrode position can affect the CMAP onset latency and amplitude, and these differences seem to be related to the generation of far field potential by CMAP.

Rheological Properties of Antiphlamine-S® Lotion (안티푸라민-에스® 로션의 레올로지 특성 연구)

  • Kuk, Hoa-Youn;Song, Ki-Won
    • Journal of Pharmaceutical Investigation
    • /
    • v.39 no.3
    • /
    • pp.185-199
    • /
    • 2009
  • Using a strain-controlled rheometer [Advanced Rheometric Expansion System (ARES)], the steady shear flow properties and the dynamic viscoelastic properties of $Antiphlamine-S^{(R)}$ lotion have been measured at $20^{\circ}C$ (storage temperature) and $37^{\circ}C$ (body temperature). In this article, the temperature dependence of the linear viscoelastic behavior was firstly reported from the experimental data obtained from a temperature-sweep test. The steady shear flow behavior was secondly reported and then the effect of shear rate on this behavior was discussed in detail. In addition, several inelastic-viscoplastic flow models including a yield stress parameter were employed to make a quantitative evaluation of the steady shear flow behavior, and then the applicability of these models was examined by calculating the various material parameters. The angular frequency dependence of the linear viscoelastic behavior was nextly explained and quantitatively predicted using a fractional derivative model. Finally, the strain amplitude dependence of the dynamic viscoelastic behavior was discussed in full to elucidate a nonlinear rheological behavior in large amplitude oscillatory shear flow fields. Main findings obtained from this study can be summarized as follows : (1) The linear viscoelastic behavior is almostly independent of temperature over a temperature range of $15{\sim}40^{circ}C$. (2) The steady shear viscosity is sharply decreased as an increase in shear rate, demonstrating a pronounced Non-Newtonian shear-thinning flow behavior. (3) The shear stress tends to approach a limiting constant value as a decrease in shear rate, exhibiting an existence of a yield stress. (4) The Herschel-Bulkley, Mizrahi-Berk and Heinz-Casson models are all applicable and have an equivalent validity to quantitatively describe the steady shear flow behavior of $Antiphlamine-S^{(R)}$ lotion whereas both the Bingham and Casson models do not give a good applicability. (5) In small amplitude oscillatory shear flow fields, the storage modulus is always greater than the loss modulus over an entire range of angular frequencies tested and both moduli show a slight dependence on angular frequency. This means that the linear viscoelastic behavior of $Antiphlamine-S^{(R)}$ lotion is dominated by an elastic nature rather than a viscous feature and that a gel-like structure is present in this system. (6) In large amplitude oscillatory shear flow fields, the storage modulus shows a nonlinear strain-thinning behavior at strain amplitude range larger than 10 % while the loss modulus exhibits a weak strain-overshoot behavior up to a strain amplitude of 50 % beyond which followed by a decrease in loss modulus with an increase in strain amplitude. (7) At sufficiently large strain amplitude range (${\gamma}_0$>100 %), the loss modulus is found to be greater than the storage modulus, indicating that a viscous property becomes superior to an elastic character in large shear deformations.

Lock-on Characteristics of Wake Behind a Rotationally Oscillating Circular Cylinder (주기적으로 회전진동하는 원주 후류의 공진특성에 관한 연구)

  • Lee, Jung-Yeop;Lee, Sang-Joon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.8 s.239
    • /
    • pp.895-902
    • /
    • 2005
  • Lock-on characteristics of flow around a circular cylinder oscillating rotationally with a relatively high forcing frequency have been investigated experimentally. Dominant governing parameters are Reynolds number (Re), angular amplitude of oscillation (${\theta}_A$), and frequency ratio $F_R=f_f/f_n,\;where\;f_f$ is a forcing frequency and $f_n$ is a natural frequency of vortex shedding. Experiments were carried out under the conditions of $Re=4.14{\times}10^3,\;{\pi}/90{\leq}{\theta_A}{\leq}{\pi}/3,\;and\;F_R=1.0$. The effect of this active flow control technique on the lock-on flow characteristics of the cylinder wake was evaluated with wake velocity measurements and spectral analysis of hot-wire signals. The rotational oscillation modifies the flow structure of near wake significantly. The lock-on phenomenon always occurs at $F_R=1.0$, regardless of the angular amplitude ${\theta}_A$. In addition, when the angular amplitude is less than a certain value, the lock-on characteristics appear only at $F_R=1.0$,. The range of lock-on phenomena expands and vortex formation length is decreased, as the angular amplitude increases. The rotational oscillation create a small-scale vortex structure in the region just near the cylinder surface. At ${\theta}_A=60^{\circ}$, the drag coefficient was reduced about $43.7\%$ at maximum.

Accurate Characterization of T/R Modules with Consideration of Amplitude/Phase Cross Effect in AESA Antenna Unit

  • Ahn, Chang-Soo;Chon, Sang-Mi;Kim, Seon-Joo;Kim, Young-Sik;Lee, Juseop
    • ETRI Journal
    • /
    • v.38 no.3
    • /
    • pp.417-424
    • /
    • 2016
  • In this paper, an accurate characterization of a fabricated X-band transmit/receive module is described with the process of generating control data to correct amplitude and phase deviations in an active electronically scanned array antenna unit. In the characterization, quantization errors (from both a digitally controlled attenuator and a phase shifter) are considered using not theoretical values (due to discrete sets of amplitude and phase states) but measured values (of which implementation errors are a part). By using the presented procedure for the characterization, each initial control bit of both the attenuator and the phase shifter is closest to the required value for each array element position. In addition, each compensated control bit for the parasitic cross effect between amplitude and phase control is decided using the same procedure. Reduction of the peak sidelobe level of an array antenna is presented as an example to validate the proposed procedure.

Lock-on Characteristics of wake behind a Rotationally Oscillating Circular Cylinder (주기적으로 회전진동하는 원주 후류의 공진특성)

  • Lee Jung Yeop;Lee Sang Joon
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2004.11a
    • /
    • pp.18-21
    • /
    • 2004
  • Lock-on characteristics of the flow around a circular cylinder performing a rotationally oscillation with a relatively high forcing frequency have been investigated experimentally using flow visualization and hot-wire measurements. Dominant parameters are Reynolds number (Re), amplitude of oscillation $(\theta_A)$, and frequency ratio $F_R=f_f\;/\;f_n$, where $f_f$ is the forcing frequency and if is the natural frequency of vortex shedding. Experiments were carried out under the conditions of $Re=4.14\times10^3,\;\pi/15\leq\theta_A\leq\pi/3$, and $F_R=1.0$. The effects of this active control technique on the lock-on flow regime of the cylinder wake were evaluated through wake velocity measurements and spectral analysis of hot-wire signals. The rotary oscillation modified the flow structure of near wake significantly. The lock-on phenomenon was found to occur in the range of frequency encompassing the natural vortex shedding frequency. In addition, when the amplitude of oscillation is less than a certain value, the lock-on phenomenon was occurred only at $F_R=1.0$. The lock-on range expanded and vortex formation length decreased as the amplitude of oscillation increases. The rotary oscillation generated small-scale vortex structure just near the cylinder surface.

  • PDF

The relationship between nerve conduction studies and neuropathic pain in sciatic nerve injury due to intramuscular injection

  • Fidanci, Halit;Ozturk, Ilker
    • The Korean Journal of Pain
    • /
    • v.34 no.1
    • /
    • pp.124-131
    • /
    • 2021
  • Background: Sciatic nerve injury due to intramuscular injection (SNIII) is still a health problem. This study aimed to determine whether there is a correlation between neuropathic pain and electrodiagnostic findings in SNIII. Methods: Patients whose clinical and electrodiagnostic findings were compatible with SNIII participated in this retrospective cohort study. Compound muscle action potential (CMAP) and sensory nerve action potential (SNAP) amplitudes of the sural, superficial peroneal, peroneal, and tibial nerves were graded from 1 to 4. Leeds assessment of neuropathic symptoms and signs scale (LANSS) was applied to all patients. Results: Forty-eight patients were included in the study, 67% of whom had a LANSS score ≥ 12. Sural SNAP amplitude abnormalities were present in 8 (50%) out of 16 patients with a LANSS score < 12, and 28 (87.5%) out of 32 patients with a LANSS score ≥ 12, with significant differences between the groups (P = 0.011). There was a positive correlation between the LANSS score and the sural SNAP amplitude grading (P = 0.001, r = 0.476). A similar positive correlation was also found in the LANSS score and the tibial nerve CMAP amplitude grading (P = 0.004, r = 0.410). Conclusions: This study showed a positive correlation between the severity of tibial nerve CMAP/sural SNAP amplitude abnormality and LANSS score in SNIII. Neuropathic pain may be more common in SNIII patients with sural nerve SNAP amplitude abnormality.