• 제목/요약/키워드: Quick Detection

검색결과 216건 처리시간 0.023초

The development and validation of a novel liquid chromatography tandem mass spectrometry (LC-MS/MS) procedure for the determination of fluoroquinolones residues in chicken muscle using modified QuEChERS (quick, easy, cheap, effective, rugged and safe) method

  • Park, Sunjin;Kim, Hyobi;Choi, Byungkook;Hong, Chung-Oui;Lee, Seon-Young;Jeon, Inhae;Lee, Su-Young;Kwak, Pilhee;Park, Sung-Won;Kim, Yong-Sang;Lee, Kwang-jick
    • 한국동물위생학회지
    • /
    • 제42권4호
    • /
    • pp.289-296
    • /
    • 2019
  • A novel rapid procedure with liquid chromatography tandem mass spectrometry (LC-MS/MS) detection has been developed by changing various conditions including sample preparation such as QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe) methodology. This work has been involved the optimization and validation of detection method for fluoroquinolones which are widespread used in livestock especially in the chicken. Five grams of homogenized chicken muscle were extracted with QuEChERS EN and acetonitrile containing 5% formic acid and cleaned with anhydrous magnesium sulfate and C18 sorbent. The separation was performed on Acquity UPLC HSS T3 (2.1 mm×100 mm, 1.8 ㎛) column. The mobile phase A and B were composed of water containing 0.1% formic acid and acetonitrile containing 0.1% formic acid, respectively. Flow rate was 0.25 mL/min and column temperate was 40℃. LC-MS/MS with multiple reaction monitoring has been optimized for ten fluoroquinolones (ciprofloxacin, danofloxacin, difloxacin, enrofloxacin, marbofloxacin, norfloxacin, ofloxacin, orbifloxacin, pefloxacin and sarafloxacin). The method developed in this study has been presented good linearity with correlation coefficient (R2) of 0.9971~0.9998. LOD and LOQ values ranged from 0.09 to 0.76 ppb and from 0.26 to 2.29 ppb, respectively. The average recoveries were from 77.46 to 111.83% at spiked levels of 10.0 and 20.0 ㎍/kg. Relative standard deviation (%) ranged 1.28~11.90% on intra-day and 3.10~8.38 % on inter-day, respectively. This analysis method was applicable to the livestock residue laboratories and was expected to be satisfactory for the residue surveillance system.

소형루프 전자탐사법을 이용한 매설물 탐지 및 지하 전기비저항 영상화 (Detection of Buried Objects and Imaging of Subsurface Resistivity Structure using Loop-Loop EM Methods)

  • 설순지;송윤호;조성준;손정술;정승환
    • 지구물리와물리탐사
    • /
    • 제5권4호
    • /
    • pp.309-315
    • /
    • 2002
  • 소형 송수신기를 이용하는 전자탐사 방법은 이제까지 주로 금속탐지기와 같이 지하전도체의 매립위치 탐지 및 전기전도도의 정성적인 변화를 해석하는데 사용되어 왔다. 그러나 최근 들어 토목, 환경분야에서 전기전도도가 비교적 높은 지역에서의 매설물의 탐지 및 전기전도도 분포를 영상화하는 기술의 수요가 늘어남에 따라 이러한 전자탐사의 적용 및 정량적인 해석방법에 대한 연구가 활발해지고 있다. 이 연구에서는 이러한 전자탐사법의 탐사 기초원리를 간략히 소개하고, 실증 시험 지역에서 얻어진 자료를 토대로 전도성 매설물의 탐지 및 지하 전도도 분포 영상화의 실 예를 보여주었다. 이 연구를 통하여 향후 이러한 소형루프를 이용하는 다중주파수 전자탐사 장비가 전도성 매질이 존재하는 탐사 지역에서 신속하고 정확한 탐사 방법으로 활용될 수 있음을 보여주고자 하였다.

RGB Palette를 이용한 보안 로그 시각화 및 보안 위협 인식 (Study on security log visualization and security threat detection using RGB Palette)

  • 이동건;김휘강;김은진
    • 정보보호학회논문지
    • /
    • 제25권1호
    • /
    • pp.61-73
    • /
    • 2015
  • 빠르게 증대되고 있는 다양한 보안 위협에 신속하게 대응하기 위해 기업들은 보안관제 담당자에게 방화벽, IDS 등의 보안장비에서 생성되는 방대한 양의 로그 등을 신속하게 분석하여 보안 위협을 파악하도록 요구하고 있다. 그러나 인간의 정보처리 능력의 한계로 인하여 방대한 양의 보안 관련 로그를 분석하는 데 있어 보안 관제 담당자는 많은 시간을 필요로 하게 되고 결과적으로 보안 위협 탐지와 대응이 늦어진다는 문제점이 존재해 왔다. 시각화 기법은 이러한 문제를 해결할 수 있는 효과적인 방법으로 본 논문은 RGB palette를 이용하여 보안 로그를 시각화, 보안 위협 상황 발생 여부를 보다 빠르고 효과적으로 인지할 수 있는 방법을 제안하고 이를 VAST Challenge 2012 데이터 세트에 실증적으로 적용하였다.

Quick Diagnosis of Short Circuit Faults in Cascaded H-Bridge Multilevel Inverters using FPGA

  • Ouni, Saeed;Zolghadri, Mohammad Reza;Rodriguez, Jose;Shahbazi, Mahmoud;Oraee, Hashem;Lezana, Pablo;Schmeisser, Andres Ulloa
    • Journal of Power Electronics
    • /
    • 제17권1호
    • /
    • pp.56-66
    • /
    • 2017
  • Fast and accurate fault detection is the primary step and one of the most important tasks in fault tolerant converters. In this paper, a fast and simple method is proposed to detect and diagnosis the faulty cell in a cascaded H-bridge multilevel inverter under a short circuit fault. In this method, the reference voltage is calculated using switching control pulses and DC-Link voltages. The comparison result of the output voltage and the reference voltage is used in conjunction with active cell pulses to detect the faulty cell. To achieve this goal, the cell which is active when the Fault signal turns to "0" is detected as the faulty cell. Furthermore, consideration of generating the active cell pulses is completely described. Since the main advantage of this method is its simplicity, it can be easily implemented in a programmable digital device. Experimental results obtained with an 11-level inverter prototype confirm the effectiveness of the proposed fault detection technique. In addition, they show that the diagnosis method is unaffected by variations of the modulation index.

Ribose-induced Maillard Reaction as an Analytical Method for Detection of Adulteration and Differentiation of Chilled and Frozen-thawed Minced Veal

  • Akbarabadi, Masoumeh;Mohsenzadeh, Mohammad;Housaindokht, Mohammad-Reza
    • 한국축산식품학회지
    • /
    • 제40권3호
    • /
    • pp.350-361
    • /
    • 2020
  • Quality control of meat products is one of the main concerns of consumers, governmental control authorities, and retailers. The purpose of this study was to employ ribose-induced Maillard reaction in detection of meat adulteration and differentiation of fresh-chilled from frozen-thawed minced veal. The browning intensity was assessed through measuring the absorbance at 420 nm with a spectrophotometer as well as the direct analysis of the color and pH. The results showed that CIE b*, CIE a*, and A420* values in the extract of fresh-chilled veal were significantly (p<0.05) higher than frozen-thawed samples. The extract of frozen meat samples stored at -18℃ became significantly darker and more yellowish compared to -4℃. The results showed that the A420* value in the frozen-thawed veal stored at -4℃ and -18℃ was reduced by approximately 17.22±3.53% and 11.68±2.49%, respectively, compared with fresh-chilled veal. The findings also showed that the storage temperature of minced veal and the heating time in this reaction had a significant effect on all tested variables (p<0.0001). The proposed method can be considered as an easy, quick, and inexpensive test for differentiating between the fresh-chilled and frozen-thawed minced veal.

스마트폰 센서스트림을 이용한 운전 패턴 인식 시스템 (Driving Pattern Recognition System Using Smartphone sensor stream)

  • 송충원;남광우;이창우
    • 한국산업정보학회논문지
    • /
    • 제17권3호
    • /
    • pp.35-42
    • /
    • 2012
  • 운전자의 도로 주행 데이터를 데이터베이스화한 정보는 다양하게 이용될 수 있다. 이러한 주행 정보를 이용한다면 운전자의 운전 성향을 분석하는데 도움이 될 것이다. 따라서 본 논문에서는 스마트폰을 이용하여 도로 주행 시의 센서 데이터들을 기록하고 주행 패턴을 인식하는 방법을 제안한다. 운전 성향을 분석하기에 앞서 패턴 별 주행 정보를 제공하기 위해 주행 패턴을 인식하는데 중점을 두었다. 좌회전, U턴, 우회전, 급감속, 급출발, 급가속, 과속방지턱에 해당하는 7개의 패턴을 인식하기 위한 과정으로 데이터 전처리를 통해 이벤트가 발생한 구간을 검출 후, DTW(Dynamic Time Warping) 알고리즘을 이용한 결정 방식을 적용하여 패턴을 인식한다. 제안된 방법은 운전자의 정보 제공을 위해 인식된 패턴과 함께 동시에 녹화된 비디오 스트림도 제공되며, 이는 안전운전시스템이나 운전습관분석시스템의 중요한 요소라 할 수 있다.

AQM과 ECN을 사용한 TCP 변종의 성능 분석 (Performance Analysis of TCP Variants using AQM and ECN)

  • 아흐메드 메틴;아드난 안워
    • 한국인터넷방송통신학회논문지
    • /
    • 제16권1호
    • /
    • pp.129-137
    • /
    • 2016
  • 전송계층 프로토콜처럼 전송제어 프로토콜은 안정적인 데이터 전송 서비스를 제공한다. 다양한 네트워크에서 TCP의 성능을 저해하는 일부 심각한 문제가 있다. TCP 네트워크 환경에서 중요한 문제는 빠른 전송 속도로 인해 또는 동시에 네트워크로 접속하는 다수의 새로운 접속으로 인하여 발생하는 혼잡이다. 그러므로 라우터에서 큐의 크기는 패킷 하락에 기인하여 증가한다. 손실된 패킷의 재전송과 감소된 처리량은 많은 비용을 발생시킨다. RED처럼 AQM과 ECN은 패킷 하락 보다는 패킷 마킹에 사용된다. IP 패킷 헤더에서 ECN 비트는 불필요한 패킷 하락을 피하기 위한 혼잡 표시로 추가할 수 있다. 제안하는 ECN과 AQM 메커니즘은 NS2 시뮬레이터의 도움으로 구현할 수 있으며, 그 성능은 다른 TCP 변종에서 테스트할 수 있다.

GPS 위성 시계 이상 검출을 위한 위성 시계 오차 추정 정확도 향상 (Improving Estimation Accuracy of Satellite Clock Error for GPS Satellite Clock Anomaly Detection)

  • 허윤정;조정호;허문범
    • 한국항공우주학회지
    • /
    • 제39권3호
    • /
    • pp.225-231
    • /
    • 2011
  • GPS 위성 이상 신호의 발생 요인 중 위성 시계의 이상 현상은 GPS 측정치에 매우 큰 영향을 미칠 수 있으나, 측정치에는 궤도 오차, 이온층 지연 오차, 대류층 지연 오차, 다중경로 오차, 수신기 시계 오차 등의 성분들이 포함되어 있어 위성 시계의 오차 범위가 다른 요소에 의한 오차보다 커지기 전에는 위성 시계의 이상 현상을 검출하기 어려운 문제가 있다. 위성 시계에 이상 현상이 발생하였을 때 이상 판별의 임계 범위를 최소화 하여 빠르고 정확하게 검출을 수행할 수 있도록, 본 논문에서는 이중 주파수 측정치로부터 반송파 스무딩 필터를 적용하고 수신기 시계 오차 및 다른 여러 가지 요인에 의한 오차를 보정한 후 정확한 위성 시계 오차를 추정하는 방법을 제시하였고 IGS 기관에서 제공하고 있는 위성 시계 정보와 비교를 통해 제시한 방법의 성능을 확인하였다.

소지방 중 잔류농약분석을 위한 액-액분배법과 modified QuEChERS법 비교 (Comparison between the liquid-liquid partition method and modified QuEChERS method for the analysis of pesticide residues in beef fat)

  • 김연주;최윤화;신방우;이정학
    • 한국동물위생학회지
    • /
    • 제34권4호
    • /
    • pp.429-439
    • /
    • 2011
  • This article described the comparison of a quick, easy, cheap, effective, rugged and safe (QuEChERS) sample preparation and the classical method established by National Veterinary Research and Quarantine Service (NVRQS) for the determination of pesticide residues in livestock products using GC-tandem mass spectrometry. The classical method by NVRQS used liquid-liquid partioning followed by evaporizing. The modified QuEChERS entailed extraction of 2 g sample with 15 ml acetonitrile containing 1% acetic acid followed by addition of 6 g anhydrous magnesium sulfate and 1.5 g sodium acetate. After centrifugation, 6 ml of the extract underwent a cleanup step (in a technique known as column-based solid phase extraction) using 400 mg each of $C_{18}$ and primary secondary amine sorbents plus 1,200 mg magnesium sulfate. The quantitation of individual pesticides by both methods was based on tissue standard calibration curves with a correlation coefficient in excess of 0.98 for the 24 pesticides. The detection limits by the classical method were ranged 1.3~5.0 ${\mu}g$/kg, with mean recoveries between 76.2% and 114.3% except aldrin (59.3%) and deltamethrin (63.6%). The detection limits by modified QuEChERS were ranged 0.3~6.2 ${\mu}g$/kg, with mean recoveries between 68.0% and 114.3% except dimethipin (152.6%), chlorfenvinphos (138.1%), 4,4-DDT (61.5%), aldrin (60.4%) and chinomethionate (30.3%).

Simultaneous Analysis of Conazole Fungicides in Garlic by Q-TOF Mass Spectrometer Coupled with a Modified QuEChERS Method

  • Bong, Min-Sun;Yang, Si-Young;Lee, Seung-Ho;Seo, Jung-Mi;Kim, In-Seon
    • 한국환경농학회지
    • /
    • 제30권3호
    • /
    • pp.323-329
    • /
    • 2011
  • BACKGROUND: The conazoles, difenoconazole, diniconazole, hexaconazole, penconazole and tetraconazole are a large class of synthetic fungicides used extensively for foliage and seed treatments in agricultural crops. The extensive use of conazoles has brought concerns on the potentiality of environmental contamination and toxicity. Thus studies on the development of methods for monitoring the conazoles are required. METHODS AND RESULTS: A modified quick, easy, effective, rugged and safe (QuEChERS) method was involved in sample preparation. Quadrapole time of flight mass spectrometer (Q-TOF MS) in electron spray ionization (ESI) mode was employed to determine conazoles in garlic samples. The limit of detection (LOD) and limit of quantification (LOQ) of conazoles by Q-TOF-MS ranged from 0.001 to 0.002 mg/L and 0.002 to 0.005 mg/L, respectively. Q-TOF-MS analysis exhibited less than 2.6 ppm error of accurate mass measurements for the detection of conazoles spiked at 0.05 mg/L in garlic matrix. Recovery values of conazoles fortified in garlic samples at 0.02, 0.05 and 0.1 mg/L were between 79.2 and 106.2% with a maximum 11.8% of standard deviation. No detectable conazoles were found in the domestic market samples by using the Q-TOF-MS method. CONCLUSION(s): High degree of confirmation for conazoles by accurate mass measurements demonstrated that Q-TOF-MS analysis combined with a QuEChERS method may be applicable to simultaneous determination of conazoles in garlic samples.